PROJECT
M/S ATC INDIA INFRASTRUCTURE PVT.
CLIENT CHECKED BY AMIT SHARMA
LTD.
DESIGN OF PILE FOUNDATION FOR
JOB NAME DATE 07-02-2020
MONOPOLE TOWER
Pile Capacity Comp./Uplift (As per IS2911 Part I/Sec 2)
109.55
= %
Bearing Resistance = 94.76 T
Friction Bearing Resistance = 109.55 T