FEATURE

SCREED DEPTH
This month the Screed Scientist discusses minimum screed thickness on
traditional, fast-drying and anhydrite screed considering different applications.
One of the keys to laying a perfect Underfloor heating
floor is to install a good-quality screed, Tracker insulation panel Screed Floor finish screed construction
which must be solid, level, flat, and Damp proof membrane
thick enough to bring the sub-floor Prepared concrete Edge strip board
to the pre-established height. Whilst
standard screeds are typically laid at a
minimum thickness of 75mm, a number
of polymer modified screeds have been
developed to deliver high performance
at reduced depths.
Polymer modified formulations
incorporate special additives that control
the curing and drying process along with
of just 3 days, in ideal ambient these screeds are incompatible with
screed performance in service, which
conditions, facilitating early installation cementitious adhesives and should not
translates into lower moisture content.
of decorative treatments. Fast-drying be used in areas subject to dampness.
As a result, screeders are able to deliver
screeds are also characterised by a low According to experts, the minimum
thinner yet sound, durable, completely
shrinkage rate and stable performance application thickness for anhydrite
dry sub-floors within tight time frames.
in underfloor heating. To deliver a screeds is between 25mm and 45mm,
durable, efficient construction a with 25mm above heating elements.
TRADITIONAL SCREEDS minimum screed thickness of 25mm is
Traditional sand-cement screeds are Correctly specifying the type and
required over the heating elements in
mixed in a 1:3, 1:4, or 1:5 ratio and thickness of the floor screed during
underfloor heating applications.
installed semi dry, in situ, at a minimum the earliest phase of the architectural
thickness of 75mm for commercial floors. design process is critical for project
Since traditional screeds do not contain ANHYDRITE SCREEDS success. As each floor and flooring
additives, they take approximately 110 Anhydrite screeds have a liquid
finish is different, we recommend that
days to dry thoroughly (one day per mm consistency. Hence, they are easier
you consult a professional screeding
up to 40mm and two days per mm over to install in large areas and can be
company for your specific screed
40mm). Besides levelling sub-floors applied at reduced thicknesses.
depth requirements.
and bringing them to the desired height, Anhydrite formulations also have a
traditional floor screed formulations low shrinkage rate, which makes them For additional information about screeds
can be used to enhance the energy suitable for use in conjunction with and recommended thicknesses, visit
efficiency of underfloor heating systems. underfloor heating systems. Made from the Screed Scientist website or call our
In underfloor heating, standard sand- calcium sulphate, sand, and water, experts on 0845 500 4055.
cement screeds should be laid at a
minimum thickness of 30mm over the A Quick Guide to Minimum Screed Thicknesses**
heating elements. Traditional screeds Fast Dry/Modified
are suitable for a wide variety of Traditional Anhydrite
Screeds
applications, ranging from residential
Bonded 20 mm 15 mm 25 mm
to commercial projects.
Unbonded 50 mm 40 mm 30 mm
FAST-DRYING SCREEDS 65 mm residential
Fast-drying floor screed formulations Floating 65 mm 35 mm
75 mm commercial
contain special additives and
admixtures enable accelerated drying Underfloor 65 mm residential
60 mm 45 mm
and hardening. Laid at a minimum heating 75 mm commercial
depth of 15mm to 65 mm, depending Depth over
on the application, these screeds allow 30 mm 25 mm 25 mm
pipes
light foot traffic to commence as early
** Please note, this is a general guide only and you should seek professional advice. There are many
as 12 hours from the installation.
proprietary products on the market that can have higher or lower thickness requirements depending
Additionally, a 60mm layer of fast- on the application. For example screeds that will take heavy traffic generally require more in thickness.
drying screed can have a drying time Please consult the relevant product data sheets.

twitter.com/TomoFlooring 19