The DynaSet™ Anchor is a medium duty, displacement setting
expansion anchor. db dh
Benefits, Advantages and Features
Fast installation: LI
~ Shallow embedment and simple setting action.
Convenient:
~ Threaded rod can be cut to equal lengths.
Principal Applications
~ Flanged version sits flush with surface in overdrilled holes. Ideal ~ Suspended services, such as cable tray,
as reusable anchorage point: ventilation ducts or plumbing fixtures.
~ Internal threaded design. ~ Stadium seating.
~ Holding down machinery.
~ No protruding metal parts when bolt or rod is removed.
~ Installing racking.
Superior corrosion resistance:
~ Suspended ceilings.
~ AISI 316(A4) Stainless Steel.
Installation
1. Drill hole at recommended diameter, to at least the anchor
length in depth. Clean hole thoroughly with a brush. Remove
debris by way of a vacuum pump, compressed air, hard
pump etc.
2. Insert anchor and push to required depth. Using the special
setting tool, drive the expander plug down until shoulder of
the setting punch meets top of the anchor.
3. Position fixture then insert the bolt and tighten with torque
wrench. The DynaSet™ anchor remains set in position if
the bolt is removed.
I Anchor Length (mm) db Thread Size dh Anchor Hole hl Hole Depth (mm) Finish Pack Order No.
X Diameter (mm) Quantity
d Anchor Size (mm)
16 138x16 M12 16 125 S/S 10 RSR12SS
138x16 M12 16 125 Gal. 10 RSR12GM
Non-destructive pull-out test of 6kN and sustain for a minimum of 15 seconds is required for each Safety Ring Anchor after installation to
ensure the compliance of BS EN 795 Standard.
112
DYNASET™ DROP-IN ANCHOR
Installation and Working Load Limit performance details
Drill Hole Fixture Hole Anchor Tightening Concrete* Anchor* Shear Tensile Working Load (kN) FOS = 3
Anchor Concrete compressive cube strength fcc (N/mm2)
Diameter, Hole Dia, Depth, Effective Torque, Edge Spacing FOS = 3
Size, db
dh (mm) df (mm) hl (mm) Depth (mm) T (Nm) (mm) (mm) (kN) 25 N/mm2 30 N/mm2 40 N/mm2
∆
M6 8 7 28 23 6 80 69 1.9 2.2 2.5 2.8
∆
M8 10 9 33 28 10 100 84 2.4 3.0 3.3 3.8
M10 12 12 43 38 20 135 114 2.9∆ 4.7 5.2 6.0
M12 16 14 53 48 40 170 144 5.5∆ 6.7 7.4 8.5
M16 20 18 68 63 95 220 189 8.7∆ 10.1 11.2 12.7
M20 25 22 83 78 180 275 234 10.9∆ 13.9 15.4 17.6
This table does not consider edge distance and anchor spacing effects, hence is a guide only and its use should not replace a complete design process.
* For shear loads acting towards an edge or where these dimensions are not achievable, please use the simplified strength limit state design
process to verify capacity.
Note: For recommended test load for single anchor = Working Load (kN) x 1.5
∆
Limited by Steel Strength (Carbon Steel). For Stainless Steel Trubolt, please refer to design tables for respective recommended load.
Engineering Properties
113
DYNASET™ DROP-IN ANCHOR
Strength Limit State Design
30 ~ fcc = 40 N/mm2
~ Bolt capacity to be confirmed separately.
~ Strength limit state design.
20
M20
M16
10
M12
M10
M8
M6
0
0 10 20 30
Design shear action, V* (kN)
Table 1b Absolute minimum edge distance and anchor spacing values, em and am (mm)
Anchor size. db M6 M8 M10 M12 M16 M20
Edge distance, em 80 100 135 170 220 275
Anchor spacing, am 60 70 95 120 160 195
Anchor size determined, absolute minima compliance achieved, effective depth (hef) calculated.
114
DYNASET™ DROP-IN ANCHOR
Strength Limit State Design
Table 2a Reduced characteristic ultimate concrete tensile capacity, ØNuc (kN), Øc = 0.6
Anchor size, db M6 M8 M10 M12 M16 M20
Effective Depth, hef(mm) 23 28 38 48 63 78
Concrete compressive strength,
fcc (N/mm2)
25 4.0 5.4 8.5 12.0 18.1 25.0
30 4.5 6.0 9.5 13.5 20.3 27.9
40 5.1 6.8 10.7 15.2 22.9 31.6
SO 5.7 7.6 12.0 17.0 25.6 35.3
For working load design per BD requirement, Nas = ØNuc/O.6/3 (BD requires safety factor of structural fixing = 3 minimum)
115
DYNASET™ DROP-IN ANCHOR
Strength Limit State Design
Design reduced ultimate concrete shear capacity, ØNurc Working load concrete tensile capacity, Nar
ØNurc = ØNuc * Xnc * Xne * Xnae Nar = Nac * Xnc * Xne * Xnae
Step 3b Reduced characteristic ultimate bait steel tensile capacity, ØNtf (kN)
Establish the reduced characteristic ultimate bolt steel tensile capacity, ØN tf from literature supplied by the.
specified bolt manufacturer.
For nominal expected capacities of bolt manufactured to ISO standards, refer to section XXX, Page XXX.
116
DYNASET™ DROP-IN ANCHOR
Strength Limit State Design
Load direction effect, Xvd 1.00 1.04 1.16 1.32 1.50 1.66 1.80 1.91 1.98 2.00
conc. edge shear, Xvd
Table 4d Anchor spacing effect, concrete edge shear, Xva
Note: For single anchor designs, Xva = 1.0
Xva = 0.5 (1+a/2.5e) ≤ 1
Edge distance, e (mm) 80 100 125 150 175 200 250 300 350 400 500 650
Anchor spacing, a (mm)
60 0.65 0.62 0.60 0.58 0.57 0.56 0.55
70 0.68 0.64 0.61 0.59 0.58 0.57 0.56 0.55
80 0.70 0.66 0.63 0.61 0.59 0.58 0.56 0.55
100 0.75 0.70 0.66 0.63 0.61 0.60 0.58 0.57 0.56 0.55
120 0.80 0.74 0.69 0.66 0.64 0.62 0.60 0.58 0.57 0.56
160 0.90 0.82 0.76 0.71 0.68 0.66 0.63 0.61 0.59 0.58 0.56
200 1.00 0.90 0.82 0.77 0.73 0.70 0.66 0.63 0.61 0.60 0.58 0.56
250 1.00 0.90 0.83 0.79 0.75 0.70 0.67 0.64 0.63 0.60 0.58
300 0.98 0.90 0.84 0.80 0.74 0.70 0.67 0.65 0.62 0.59
400 1.00 1.00 0.96 0.90 0.82 0.77 0.73 0.70 0.66 0.62
500 1.00 1.00 0.90 0.83 0.79 0.75 0.70 0.65
625 1.00 0.92 0.86 0.81 0.75 0.69
750 1.00 0.93 0.88 0.80 0.73
875 1.00 0.94 0.85 0.77
1000 1.00 0.90 0.81
1250 1.00 0.88
1625 1.00
This table should be read in conjunction with Table 4a, changing the edge distance "e" in this table also change the "e" in table 4a.
117
DYNASET™ DROP-IN ANCHOR
Strength Limit State Design
Design reduced ultimate concrete shear capacity, ØVurc Working load concrete tensile capacity, Var
ØVurc = ØVuc * Xvc * Xvd * Xva * Xvn Var = Vac * Xvc * Xvd * Xva * Xvn
Table 5b Reduced characteristic ultimate bolt steel shear capacity, ØVsf (kN)
Establish the reduced characteristic ultimate bolt steel shear capacity, ØVsf from literature supplied by the. specified
bolt manufacturer.
For nominal expected capacities of bolt manufactured to ISO standards, refer to section XXX, Page XXX.
118
DYNASET™ DROP-IN ANCHOR
Strength Limit State Design
Specify
Ramset™ Dynaset™ Anchor,
(Anchor Size) ((Part Number))
with a (Bolt Grade) bolt.
Example
Ramset™ Dynaset™ Anchor. M16
(DSM16) with a Gr. 4.6 bolt.
To be installed in accordance with
Ramset™ Technical Data Sheet.
119