You are on page 1of 3

Report No.

99/2012 Number of pages 3 Page 1 Number of enclosures: 1

VÚD a. s., Testing laboratory for strength measurement of machines parts


Veľký Diel, 010 08 Žilina, phone No.: 041/5686 454

REPORT No. 99/2012


about test result
ACCREDITED TEST

1. Name and address customer:


Tesa tape, s.r.o. – branch Slovakia, Riznerova 5, 811 01 Bratislava.

2. Title, type of the testing object:


Strength test tensile bond. Material: plate FeZn + C-profile.

3. The date of acceptance of the product for performing the test, description of the sampling:
Acceptance of samples on 03. 12. 2012.

4. Date of test realization:


The test was realized on 17. 12. 2012 on the basis of the order No. 41171SK/12, date of the order 03. 12. 2012.

5. Norms and test methodology:


The tests were realized in accordance with „The methodical instructions for executing the basic mechanical tests of
metals, the tension test“ relating to the STN EN ISO 6892-1.

6. Information concerning the test:


For testing there was used the loading machine EU40, number 990.56/6, that is official approved by the Legal
metrology service for the precision class 1, verification document no. 0429/323.04/11 validity until 14. 11. 2013.
Measure 0 - 400 kN.
Samples in the corrosion chamber were tested in compliance with STN EN ISO 9227 at discontinuous cycle. One cycle
was for 22 hours in the salt spray and 2 hours under laboratory conditions. Number of cycles was 10. The test in
corrosion chamber was carried out at temperature of 35 ° and relative humidity of 100%. Salt solution flow rate was
1.9 ml / h, pH of the salt solution was 6.9.
Report No. 99/2012 Number of pages 3 Page 2 Number of enclosures: 1

7. The measured values:

Number Type Fm
of samples of connection [kN]
0 bolted connection 4,1
1 1mm tape 7074, zinc-plated /C profile, prepare cleaning/grinding – strength test 3,0
2 1mm tape , zinc-plated /C profile, prepare cleaning/grinding – strength test after corrosion chamber 1,4
3 2mm tape 7078, zinc-plated /C profile, prepare cleaning/grinding – strength test 2,3
4 2mm tape, zinc-plated /C profile, prepare cleaning/grinding – strength test after corrosion chamber 0,9
5 1mm tape 7074, zinc-plated /C profile, prepare cleaning/promoter – strength test 2,5
6 1mm tape, zinc-plated /C profile, prepare cleaning/promoter – strength test after corrosion chamber 1,9
7 2mm tape, zinc-plated /C profile, prepare cleaning/promoter – strength test 2,0
8 2mm tape, zinc-plated /C profile, prepare cleaning/promoter – strength test after corrosion chamber 1,7
1/1 25mm tape, zinc-plated /C profile, prepare cleaning/grinding – strength test 1,4
1/2 25mm tape, zinc-plated /C profile, prepare cleaning/grinding – strength test after corrosion 0,9
chamber
2/1 19mm tape, zinc-plated /C profile, prepare cleaning/grinding – strength test 1,0
2/2 19mm tape, zinc-plated /C profile, prepare cleaning/grinding – strength test after corrosion 0,7
chamber
3/1 25 mm tape, zinc-plated /C profile, prepare cleaning/grinding – strength test 1,5
3/2 25mm tape, zinc-plated /C profile, prepare cleaning/grinding – strength test after corrosion 1,4
chamber
4/1 25mm tape, zinc-plated /C profile, prepare cleaning/promoter – strength test 1,4
4/2 25mm tape, zinc-plated /C profile, prepare cleaning/promoter – strength test after corrosion 1,2
chamber
5/1 19mm tape, zinc-plated /C profile, prepare cleaning/promoter – strength test 1,1
5/2 19mm tape, zinc-plated /C profile, prepare cleaning/promoter – strength test after corrosion 0,9
chamber
A 25 mm tape TESA, profile/profile set 1,050
B 25 mm páska xx, profile/profile set 1,086

Fm – tensile strength
Report No. 99/2012 Number of pages 3 Page 3 Number of enclosures: 1

Enclosures:
Enclosure No. 1 - photos

Ambient temperature 19°C

Žilina, December 21, 2012

Ing. Juraj Zimen Ing. Juraj Sloboda


signature of technician signature of the head

The results are concerned only the testing object and do not replace other documents, which are demanded by organizations
of state professional supervision according to specific regulations.
The report can be reproduced only as the whole on the understanding that the Testing laboratory brings out a written
consent on its reproduction.