You are on page 1of 1

ASPL/QC2/03

AXIVA SICHEM PVT. LTD.


STANDARD OPERATING PROCEDURE REV: 00, ISSUE: 01
Thickness of Nylon Membrane Filter Effective Date
1st Nov. 2017

Thickness of Nylon Membrane Filter

1. Objective
To measure the thickness of Nylon Membrane Filter.
2. Scope
To insuring the thickness of Nylon Membrane Filter as per specifications.
3. Responsibility & Accountability
Quality Control (QC), Head is responsible for thickness of the Nylon Membrane Filter.
4. Requirement
Digital Micrometer
5. Procedure
 Take Sheets of Nylon Membrane Filter and measure it at Start, Middle & End of the Membrane
 Take average/mean of both the three different measurements and note it down.
 Match the measurement with Nylon Membrane Specifications.
6. Precautions
 Always reset the value ZERO while taking thickness of Nylon Membrane.

Quality Acceptance Thickness of Nylon Membrane


0.1 µm (P) 0.2 µm (R) 0.45 µm (X) 0.8 µm (N) 1.2 µm (U) 1.5 µm (T) 0.2 µm (HF) 0.45 µm (HF)
140 ± 10 µm 150 ± 10 µm 160 ± 10 µm 160 ± 10 µm 160 ± 10 µm 160 ± 10 µm 150 ± 10 µm 160 ± 10 µm

PREPARED BY: APPROVED BY: