You are on page 1of 66

Information for installers

Daikin Altherma
low temperature
heat pump

Air to water heat pumps with the highest efficiency for new build
Why choose Daikin?
So can you meet all your objectives. As an industry leader, Daikin supports you with
a combination of broad experience, technical innovation and responsive customer service.

 Comfort   Energy Efficiency


Your customers demand optimal comfort levels at By using free, renewable energy combined with
all times for their space heating and domestic our highly efficient inverter heat pump technology,
hot water needs. The Daikin Altherma heat pump the Daikin Altherma gives your customers
guarantees this as only Daikin can. the ultimate in seasonal energy efficiency.

 Reliability
 Control
Reliability is a prerequisite for any new heating
Our specially developed and proven control system system – for installers and end users.
with its new user interface makes the Daikin Daikin technology, designed and manufactured to
Altherma heat pump intuitive and easy to control. the highest standards, has proved to be the ultimate
This means easy commissioning for you, while users in reliability. Based on years of development and
can be totally in charge of their comfort and costs. experience, and manufactured to exact tolerances,
our technology will give years of trouble-free
operation.

2
Daikin quality
Daikin has a worldwide reputation based on 90 years of experience in
the successful manufacturer of high-quality air conditioning equipment
for residential, commercial and industrial use. It has been a leader in heat pump
technology for 56 years. Daikin’s much envied quality quite simply stems from
the close attention we pay to design, production and testing, as well as aftersales
support. To this end, every component is carefully selected and rigorously tested
to verify its contribution to product quality and reliability.
This ensures that every Daikin installation is a successful one for you.

Seasonal efficiency,
smart use of energy The seasonal efficiency (also called SCOP) of a heat
pump is the average efficiency over a whole year.
The total heating output per year is defined by
The EU wants to inform people about the climatic conditions and house specifications
the amount of energy that products consume, (heat load, required water temperatures, etc.), and is
and will ban inefficient products from the independent of the type of heating system.
The total electricity input per year is the critical
market. Seasonally-efficient units are optimised parameter, as this is what the customer pays for.
to be energy efficient for the average conditions This means the SCOP value can be seen as the real
users can expect over an entire heating and operating efficiency of a heat pump system.
cooling season.

From September 2015, all heating systems, Heat pump efficiency


including those using heat pumps, will receive
an energy label to help customers make
=
the most energy-efficient choice. SCOP
System efficiency*:
=

A ++ heating output / year


A electricity input / year
* EHVH04S18CB3V + ERLQ004CV3

3
Why choose

Daikin Altherma low


temperature heat pump?
3 systems in 1: heating, Why heat pump?
cooling and hot water The Daikin Altherma heat pump uses a sustainable
energy source: extracting heat from the outside air.
Daikin Altherma is a total heating and domestic hot In a closed loop containing a liquid refrigerant,
water system with an option for cooling. Based on a thermodynamic cycle is created through
heat pump technology, it represents a flexible and evaporation, condensation, compression and
cost-effective alternative to a fossil fuel boiler. The expansion. This “pumps” heat from a lower to a higher
inherent energy efficiency of Daikin Altherma makes temperature level. Via a heat exchanger
it an ideal solution for your customers looking for the heat gained is transferred to the home’s warm
reduced energy consumption and low CO2 emissions. water distribution system. This can be under-floor
heating, low temperature radiators and/or fan coil
Depending on the model and conditions,
units. For cooling, the system operates in reverse.
a Daikin Altherma heat pump delivers about 5kWh of
usable heat for every kWh of electricity it consumes.
This means approximately 80% of the heat is free!
Talk about a good investment.

The high efficiency system


By making use of the heat in the outside air,
the system uses much less energy while occupants
enjoy a stable and pleasant level of comfort.
Also, maintenance requirements are minimal, keeping
running costs low. Thanks to advanced compressor
technology, the energy savings are even greater.

80%
ambient air

100%
energy
25%
electricity

4
The complete solution
Solar collector Convector Hot water
With the integrated solar unit or in Heating and cooling Hot water is always available
option with the wall mounted unit with convector integration. with Daikin’s air-to-water heat pump
system, along with outstanding
energy savings.

Outdoor unit

Integrated floor standing indoor unit Under floor heating


Heating and domestic hot water in one unit. Interior spaces are warmed using the hot water
generated by the heat pump.

5
An innovative product 1. Floor-standing unit with integrated
Solutions

range, designed to deliver domestic hot water tank

only the best in


climate control:

offered in Different
technologies

4 solutions
Specifications p 22

Best seasonal efficiencies


for highest savings on The benefits
›› All components and connections
factory-mounted
running costs  p 08 with the low
temperature
heat pump
›› Very small installation footprint required
›› Minimum electrical input with
constantly available hot water
›› Excellent SCOP ratings up to 4.52 for incentive
and certification schemes
›› No (or very limited) use of electrical assistance
for back-up heating
›› Best efficiencies achieved within the most relevant
temperature range

Different
heating
Perfect fit for new builds applications

and low-energy houses  p 14


›› Custom-made product for very low heat loads
›› Built to withstand the most severe winter conditions
›› Heating, cooling and domestic hot water in one system
Functionalities

Servicing made easy for long


and trouble-free operation  p 44 Installation

Specifications p 47
Different
heat emitters

6
2. Integrated solar unit and
3. Wall mounted unit 4. Monobloc outdoor unit
domestic hot water tank

p 28 p32 p 38

›› Compact unit with


small installation space, almost
›› Compact monobloc for space
›› Solar support for domestic hot water no side clearances required
heating & cooling with optional
with solar system ›› Can be combined with a separate
domestic hot water
›› Lightweight plastic tank domestic hot water tank
›› Fuss-free installation: only water
›› App control possible (up to 500 litres) with or without
connections required
solar support

›› Ideal for new houses, low energy houses


or together with an existing boiler (bivalent)
›› Bivalent option: combinable with a secondary heat source
›› Reliable operation even when -25°C outside, thanks to frost
protection features such as free hanging coil

›› Space heating
›› Domestic hot water
›› Cooling
›› Solar connection for hot water production

›› 1 indoor unit
›› 1 outdoor unit
›› 1 outdoor unit

›› Under floor heating


›› Low temperature radiators
›› Fan coil units
›› Heat pump convector

7
Best seasonal efficiencies,

providing
the highest
savings
on running
costs
With many years of air-to-water
heat pump experience and over
175,000 units installed throughout
Europe, we continuously strive
to optimise Daikin Altherma’s
performance. We do this by
maximising energy output and
limiting electrical inputs.
As an installer, this means you are ready
to meet the growing demand for more
energy efficient systems.

8
Integrated floor standing unit

Domestic hot water

Combine system with


solar energy

Integrated solar unit

Under floor heating

Wall mounted unit Cooling

9
Best seasonal efficiencies

a. Low running costs: high heat pump efficiencies at all


outdoor and water temperatures

Daikin Altherma low temperature provides excellent


ratings that comply with European legislation
and certification schemes, and/or local incentive Swing Scroll
programs. Each capacity class has an individually
sized compressor, dimensioned for optimal
efficiencies per capacity range. This avoids having an
over-dimensioned compressor with lower seasonal
efficiencies.
For example, the compressor of the 4kW class is
designed to work at optimal frequencies, delivering
the low capacities needed by houses with low heat
loads. In addition, the Daikin Altherma optimises
efficiency at all outside and water temperatures
through: ›› Low-capacity 4-8kW range is equipped
with swing compressor: integration of main
›› a pressure sensor for detailed measurement of moving parts in one component, assuring
condensing pressure level to evaluate the optimal no abrasion and no refrigerant leakages,
amount of subcool guaranteeing optimal reliability and efficiency.
›› an individual dimensioned plate heat exchanger ›› High-capacity 11-16kW range is equipped
per capacity class, to offer optimal efficiencies per with scroll compressors: quiet, compact
capacity range and robust, guaranteeing optimal operational
reliability (no valves and built-in swing-link
coupling) and efficiency (through a low initial
flow and a constant compression ratio).

10
Best seasonal efficiencies

b. Guaranteed performance: high heating capacities


down to low outside temperature

Daikin Altherma low temperature maintains its ›› Optimised controls to achieve higher frequency of
high heating capacities even in the lowest outdoor use at low outdoor temperatures
temperatures. Electrical back-up heater assistance ›› Liquid injection to avoid too-high discharge
is required never or rarely. These high heating temperatures when high water temperatures are
capacities, available across the whole required at low outdoor temperatures
Daikin Altherma low temperature 4kW-16kW ›› Perfectly-dimensioned plate heat exchangers to
range, are achieved thanks to the combination of maximise the heat exchange surface
technologies:

Heating capacities of a standard air-to-water heat pump


compared to the Daikin Altherma units (ERLQ-C range - 11-16 kW)
Heating capacity (kW)
›› Location: Munich 18
›› Design temperature: -15°C 16
Heat load ERLQ016C
›› Heat load: 14kW
14 Standard HP system
›› Heating off temperature: 16°C
12

10
›› + 40% capacity at -15°C
8
›› No need for back up heater from -10°C
6
onwards (compared to -5°C for standard
Less BUH
heat pump) 4
required
2

0 Outside temperature (°C)


-15 -10 -5 0 5

c. Minimum energy consumption: Daikin inverter


compressors with high modulating range
When the heat load is lower than the maximum Daikin Altherma low temperature has a high
capacity of the heat pump system, the compressor modulating range, meaning the compressor can
can turn in partial load operation. This reduced modulate down to low frequencies to offer
compressor frequency results in: the highest efficiencies over the relevant temperature
range. Each inverter compressor has a certain
›› Higher compressor efficiency in partial load maximum and minimum frequency, and works
operation inside the optimal operation area with the highest
›› Delivered capacities exactly matching the actual operating efficiencies. This is illustrated by the graph
heating demand of the building bellow.
›› Obtaining the capacities needed with minimum
energy consumption
›› Less on/off operation, increasing the operation life
cycle of the compressor

1 Heat load > max capacity: full load


Heating capacity (kW) Compressor will operate at 100% frequency, with

8 additional electrical assistance if required


Heat load line
7 1
Max frequency
2 Max capacity > heat load > min capacity:
Optimal
6 ERLQ006CAV3 max capacity partial load compressor will reduce its frequency operation
5 delivering the capacities required by the house, with area
Wide optimal operation
4
2 area at relevant outside high operating efficiencies
temperature (-2°C to 10°C)
Min frequency
3 3 Min capacity > heat load: partial load with on/off
ERLQ006CAV3 min capacity
2 Compressor will work at its minimum frequency with high
3 operating efficiencies, but switching on/off to deliver
1
the capacities required
0
-6 -4 -2 -0 2 4 6 8 10 12 14
Outdoor temperature (°C)

11
Best seasonal efficiencies

The partial load operation and optimal operation area can be illustrated
by a typical application in Paris

Typical application: Efficient partial-load operation is especially ›› Largest part of heat output
important for the temperature range where delivered at optimal efficiencies
›› Location: Paris the highest heat output is required. Typically, 80% ›› Less on/off operation when heat
›› Design temperature: -7°C of the total heat output is required in an outdoor load becomes lower than the
›› Heat load: 7kW temperature range of -2°C to 10°C. Achieving high minimum capacity the heat pump
›› Heating off temperature: 16°C efficiencies in this temperature range contributes can deliver, optimising efficiency
strongly to high seasonal efficiencies. and comfort

Operation hours (h) Heat output (kWh)

1600 1000

800
1200 High efficiency crucial in
Ta range -2C° to 10°C
600
Heat load 7kW
800
400

400
200

Operation hours
  kWh heat output
Ta switch off 0 0
-10 -2 0 10 20 30
Outdoor temperature (°C)

›› Modulating range doubled vs standard


air-to-water heat pumps
›› New range delivers around 1kW additional in
full-load condition at -7°C (+25%)

Standard heat pump Daikin Altherma


Capacity (kW) Capacity (kW)
Heat load line
8 8 Heat load line
standard heat pump max capacity
7 7
ERLQ006CAV3 max capacity
6 6
Optimal operation area too small
Wide optimal operation area at relevant
5 5
standard heat pump min capacity Ta (-2°C to 10°C)
4 4
3 3 ERLQ006CAV3 min capacity
2 2
1 1
Resulting in the best
0 0 possible effficiencies
-6 -4 -2 0 2 4 6 8 10 12 14 -6 -4 -2 0 2 4 6 8 10 12 14

Outdoor temperature (°C) Outdoor temperature (°C)

12
Best seasonal efficiencies

d. Smart heating control


The combined effect of the Daikin Altherma weather-
dependent set-point control and the Daikin Altherma The example shown is for a typical application
inverter compressors maximises the efficiency at using under-floor heating:
each outdoor temperature, assuring stable room
temperatures. ›› A water temperature of 38°C is required
at a design temperature of -10°C (1)
1 Weather-dependent set-point control: ›› A water temperature of only 25°C is required
Daikin Altherma maximises efficiency at every at a space heating off temperature of 16°C (2)
outdoor temperature through its weather- ›› For temperatures between -10°C and 16°C,
dependent set-point control. This control logic the Daikin Altherma unit calculates
will always keep the water temperatures as low as the required water temperature, to guarantee
possible, to maximise the heat pump efficiency for maximum efficiency, with continuous heating,
each specific outdoor temperature. This results in: at each outdoor temperature.

›› Higher heat pump efficiency with lower water


temperatures 1
38°C
›› No unnecessary overheating, thereby deliver-
Floating
ing the temperatures required  set-point
›› Continuous heating at lower water tempera- T set-point
tures, providing stable room temperatures (TLWC)

2 Inverter technology: lowering the compressor 2


frequency with increasing outdoor temperatures, 25°C Ta
thus increasing the efficiency
-10°C 16°C

e. Optimal use of energy limiting electrical inputs


of auxiliary components

In addition to limiting the electrical input of ›› No bottom plate heater needed on 4-8kW class
the compressor and the electrical back-up heater, ›› Low-capacity bottom plate heater on 11-16kW class
Daikin pays special attention to limiting electrical (ERLQ-C series), only operating during defrost
inputs of auxiliary components. This also contributes cycles, results in 90% less electricity consumption
to the high seasonal efficiencies achieved by when compared with standard thermostatic
the Daikin Altherma range. controlled bottom plate heaters.

›› Factory-mounted high efficiency circulating pump


›› Thanks to all these improvements,
already qualifying for future regulations (ErP2015)
COP of up to 5.2* is reached
with an A-energy label (EEI ≤ 0.23)
›› No standby losses of inverter drive PCB, lowering * ERLQ004CV3 with EHSX04P30A
electricity consumption during standby mode on (Ta DB/WB 7°C/6°C - LWC 35°C (DT=5°C))
4-8 kW class

Applicable units: 4-8kW Advantage compared Operating hours


Conditions Yearly benefit
Location: Munich (Germany) to tradional HP system per year
High efficiency circulating pump 75W less according to EN14511 5300 hours 398 kWh
No standby losses inverter drive PCB 20W less in standby mode 3400 hours 70 kWh
No bottom plate heater 60W less when Ta below 4°C 2800 hours 170 kWh

Applicable units: 11-16kW Advantage compared Operating hours


Conditions Yearly benefit
Location: Munich (Germany) to tradional HP system per year
High efficiency circulating pump 90W less according to EN14511 5300 hours 477 kWh
No standby losses inverter drive PCB 20W less in standby mode 3400 hours 70 kWh
Low capacity bottom plate heater 60W less + smart logic when Ta below 4°C 2800 hours 160 kWh

13
Perfect fit

for new builds,


as well as
for low-energy
houses
The Daikin Altherma low temperature Outdoor unit
is fully optimised to fulfil the efficiency,
comfort and application needs of
newly built houses. In addition,
the extended product range allows
you to offer your customers the perfect
solution for low-energy houses, even for
very low heat loads.

Domestic hot water tank


with solar support
Provides hot water at any time, in line
with the highest hygiene standards

14
Best seasonal efficiencies

Hot water
Hot water is always
available with Daikin’s air to water heat
pump system along with outstanding
energy savings.
Solar collector
(With integrated solar unit or in option
with the wall mounted unit)

Convector
Cooling and heating with
convector integration

Wall mounted unit Under floor heating


including all hydraulic Interior spaces can be warmed using the hot water
components can generated by a heat pump.
be combined with a separate
domestic hot water tank.

15
Perfect fit for new builds, as well as for low-energy houses

a. Optimised unit for low heat loads

Daikin Altherma low temperature is designed to Example of packaged label:


meet the requirements of newly built and low-energy integrated floor standing unit -
houses characterised by low heat loads. space heating and domestic hot water
The low capacity unit with its high modulating range
offers optimal efficiency in most relevant outdoor
temperature ranges by combining compressors and
plate heat exchangers that have been specifically
designed for smaller heat loads. This is designed to EHVX08S18CB3V /
ERLQ006CAV3
meet the needs of the new-build house market in
Europe, which is moving towards smaller heat loads
due to:
A
The new-build house market in Europe is A+
moving towards smaller heat loads, due to :

1. Growing importance of low-energy houses

2. Stronger legislation on energy consumption in new


residential constructions (e.g. EPBD regulations)

3. Decreasing size of new-build houses 3 kW


5 kW
4. EU Member States planning to reach their 5 kW
42 dB
20-20-20 targets

Daikin Altherma low temperature offers a full product 62 dB


line-up with a specifically dimensioned heat pump
system (compressor, modulating range, plate heat
exchanger, …) to deliver the required capacities
for the house, with the best possible efficiencies.

Daikin Altherma low capacity unit is developed and Example of individual product label:
dimensioned to reach optimal efficiencies at monobloc outdoor unit - space heating
the most relevant temperature range, thanks to its
high modulating range.

A consistent energy label across Europe EBLQ05CAV3

The Ecodesign Directive for heat generators and 55°C 35°C


water heaters requires them to carry energy labels
which are common across all EU member states.
The principle behind this label is already well-known A++ A++
from refrigerators, washing machines and TV sets.
Devices and appliances are currently split into
efficiency classes on a scale from A++ to G. Dark
green represents the highest level of efficiency, dark
red the lowest.

Be on the safe side with Daikin 4 kW 4 kW


4 kW 4 kW
All Daikin units are tested and meet the criteria of 4 kW 5 kW
the Ecodesign Directive. Our energy labels reliably 61 dB
show the precise efficiency class, both for individual
products up to A++ and for packages up to
A+. Perfectly matched in terms of their individual
components, our complete systems provide both 0 dB
maximum comfort and peace of mind – for dealers,
installers and end users.

16
Perfect fit for new builds, as well as for low-energy houses

This is illustrated by the practical example below

Typical application: Low-energy houses have a lower space heating off


temperature (12°C) than normal insulated houses (16°C).
›› Location: Paris This means that the most relevant outdoor temperature-
›› Design temperature: -7°C range for low-energy houses, shifts towards lower
›› Heat load: 4kW temperatures. A typical low-energy house (see details
›› Heating off below) has 80% of its total heat output in the outdoor
temperature: 12°C temperature range of -3°C to 7°C.

Operation hours (h) Heat output (kWh)

800 1000

900
700
800
600 High efficiency crucial in
Ta range -3C° to 7°C 700
500 Heat load 4kW 600

400 500

400
300
300
200
200
100
Operation hours 100
  kWh heat output
Ta switch off 0 0
-10 -5 0 5 10 15 20 25 30
Outdoor temperature (°C)

Standard heat pump Daikin Altherma


Capacity (kW) Capacity (kW)
8 8
standard heat pump max capacity
7 7
6 Heat load line 6
Optimal operation area too small Heat load line
5 and not in relevant Ta (-3°C to 7°C) 5
ERLQ006CAV3 max capacity
4 standard heat pump min capacity 4
Wide optimal operation area
3 3 at relevant Ta (-3°C to 7°C)

2 2 ERLQ006CAV3 min capacity

1 1
Resulting in
0 0
the best possible
-8 -6 -4 -2 0 2 4 6 8 10 12 14 -8 -6 -4 -2 0 2 4 6 8 10 12 14 effficiencies
Outdoor temperature (°C) Outdoor temperature (°C)

17
b. Maximum comfort

One system for optimal year-round comfort


Optimal comfort conditions Stable room temperatures

Keeping the house at the desired The combined effect of the Daikin inverter
temperature the whole year, with both heating and compressors and weather-dependent set-point
cooling possible control guarantees a continuous heating operation.

›› Only one outdoor unit required to provide heating With higher outdoor temperature, the water
and cooling temperature will be lowered and the frequency of
›› Same emitters can be used for heating and the compressor reduced, in order to ensure
cooling (Daikin heat pump convector or under- a continuous heating operation, providing stable
floor system) room temperature.

Connectable heat emitters


The Daikin Altherma low temperature has 1. Under-floor heating 25°C 35°C
an operation range up to 55°C leaving water
temperature, allowing for connection to all types of
low-temperature heat emitters. 2. Heat pump convector 35°C 45°C

The Daikin heat pump convector is specifically


designed to offer optimal efficiencies and comfort
for residential applications.

›› Small dimensions compared to low-temperature


radiators
›› Low sound level, optimal for bedroom applica-
tions (down to 19 dBA) 3. Low temperature 40°C 55°C
›› High-capacity cooling with water temperatures radiators
down to 6° C

18
Perfect fit for new builds, as well as for low-energy houses

Thanks to the multiple set-point function,


a combination of different types of heat emitters
operating at different water temperatures is possible.
When there is no heating request from the higher
temperature zone, the water temperature will be
lowered to the temperature required by the low
temperature zone. This ensures keeping the water
temperatures as low as possible, while always
guaranteeing the highest efficiency.

45°C

Balancing
vessel Low-temperature radiator

45°C
Mixing valve 35°C
Under-floor
heating

Tset Thermo status


Space 1 low-temperature radiator 45°C OFF ON ON OFF
Space 2 under-floor heating 35°C OFF ON OFF ON
Heat pump OFF 45°C 45°C 35°C

19
Perfect fit for new builds, as well as for low-energy houses

c. Guaranteed operation: Daikin Altherma is suitable


for all climates, even withstanding severe winter conditions
Daikin is renowned for its know-how related to frost protection on its heat pump
range. The outdoor units are specifically designed to avoid ice build-up problems,
even in the most severe winter conditions.
Free hanging coil

Outdoor unit 4-8 kW


Daikin Altherma low temperature has a guaranteed This adequate frost
operation down to an outside temperature of -25°C. protection results in
This ensures sufficient heat pump operation for even one product offering
the coldest climates. throughout Europe,
from the south of
The 4-8kW range of Daikin Altherma has Spain to the north of
a specifically designed casing to avoid the risk of ice Finland.
formation on the outdoor unit coil.

›› The outdoor unit has a free hanging coil, ensuring


that no ice accumulates in the lower part of
the outdoor unit. This is key to offering
appropriate frost protection and has
the additional advantage that no electrical
bottom plate heater is required
›› The discharge grille is also specifically designed to
avoid ice accumulation

4-8 kW: High pressure switch Four way valve Outdoor unit fan &
hermetically sealed The HP switch in the discharge line Used to switch the HP from fan motor
swing compressor protects the unit against too high heating (ON) to cooling mode (OFF) Helps control
pressure Reversed cycle for defrost the differential pressure
between high- and
low-pressure side.
Operates according to
ambient temperature
and condensation
temperature.

20
Perfect fit for new builds, as well as for low-energy houses

Outdoor unit 11-16 kW


The 11-16kW range of Daikin Altherma has specific
frost protection to avoid the risk of ice forming on
the outdoor unit coil.

›› Hot gas pass: hot gaseous refrigerant coming


from the compressor runs through the bottom
plate to keep the base free of ice and all the drain
holes open
›› Sub-cool pass: before the refrigerant pipe is split
by the distributor to the hairpins, the refrigerant
passes through the bottom of the coil to keep
this lower part free of ice

Only a small capacity bottom plate heater is installed


(35W), with smart operation logic only operating
during defrost cycles.
This saves around 90% of electricity consumption
compared to a traditional heat pump system with
a thermostatically controlled bottom plate heater.

Subcool pass Hot gas pipe

›› Hot gas pass in bottom plate to keep


the temperature of the bottom plate positive.
All drain holes are open so drain can get out
of the unit

›› Limited operation (only shortly before and


during defrost cycle hot gas will pass through
the hot gas pipe)
Distributor

Sealing More height difference

Bottom plate

Bottom plate heater: 100W reduced to 35 W


Standard operation only during defrost (3 min.) and
max. 3 times per hour.

Reduction of electrical consumption 5 drain holes

21
1.
Floor-standing unit with integrated
domestic hot water tank

saving installation
space and time

22
Best seasonal efficiencies

Daikin Altherma low temperature


floor standing unit with integrated
domestic hot water tank is an all-in-
one heat pump unit that includes
the domestic hot water tank (180l or
260l).
This makes it the easiest and fastest
installation for you when domestic
hot water is required. Compact
and yet 100% comfort guaranteed,
certainly the best solution – for you
and your customer!

23
Integrated floor standing unit

a. Easiest and fastest installation,


domestic hot water tank included

›› The stainless steel domestic hot water tank is ›› The electric PCB board and hydraulic components
included in the unit, with all connections between are accessible from the front. This makes servicing
the heat pump module and tank factory-mounted. easy and avoids the risk of damage to electrical
This permits a fast installation compared to components due to water leakage.
a traditional set-up (wall-mounted with separate ›› All water and refrigerant connections are at
domestic hot water tank) – saving you time. the top of the unit, for easy connection and
You only need to connect the water and accessibility. And with no connections at
refrigerant pipes. the back of the unit, the installation footprint is
›› All hydraulic components are included (circulating even smaller.
pump, expansion vessel, back-up heater, etc.).
No need to look for third-party components.

Connections
from the top
Expansion vessel

Components
are accessible from
the front
water pump

Plate heat exchanger

Domestic hot
water tank

PCB board

24
Integrated floor standing unit

b. Space saving: compact indoor unit with sleek design


your customers will appreciate

Thanks to the all-in-one design, Compared to the traditional split-up version for
the installation space is minimised both in
1 a wall-mounted indoor unit and separate domestic
terms of footprint and height hot water tank, the integrated indoor unit greatly
reduces the installation space required.

Floor standing unit with integrated


Traditional setup domestic hot water tank

Hydrobox

DHW tank

Space
reduced
VS

1732 mm
by more
than
30%

580 mm X 370 mm
72
8m
950 mm + X m
m
600 m

Smaller footprint: with a width of only 600 mm and


2 a depth of 728 mm, the integrated indoor unit has
a similar footprint compared to other household
appliances. For installation, almost no side clearances
728 mm are required. And no space is needed behind the unit
for piping, as all piping connections are at the top.
This results in an installation footprint of only 0.45 m2.

Low installation height: both the 180l and 260l


3 versions come with a height of 1732 cm. The required
installation height is less than 2 m.

The compactness of the integrated indoor unit is


600 mm + 10 mm clearance 4 emphasised by its sleek design and modern look,
on both sides easily fitting with other household appliances.

25
Integrated floor standing unit

c. Best solution for


domestic hot water heating:
high efficiency –
high comfort
up to 55°C
with heat pump only

Limited heat loss Smart control

The domestic hot water tank of the integrated indoor Daikin Altherma uses smart controls to heat
unit is equipped with thick polystyrene insulation, the domestic hot water tank, maximising efficiency
resulting in 50% less heat loss compared to a standard and comfort for the end-user. The combination of
insulated tank. This means high savings on running the schedule and reheat functions guarantees
costs, as less energy is required for the next heat-up minimum electrical input and ensures constant
cycle. availability of hot water.

Heat loss from the 180l tank: only 1.4kWh per 24h ›› Schedule function: heat the tank to a pre-set
(temperature difference of 45°C between tank and room temperature at a specified time. Can be repeated
temperature). four times per day, with the possibility of setting
two different tank temperatures (storage comfort
Maximum efficiency and storage economic).
›› Reheat function: when the tank temperature
Daikin Altherma low temperature can heat goes below a specified minimum reheat
the domestic hot water tank to high temperatures with temperature, Daikin Altherma switches
heat pump operation only, minimising the need for automatically to domestic hot water heating,
electrical assistance, and maximising efficiency. heating the tank to
a specified maximum reheat temperature.
Tank temperature up to 55°C with heat pump only,
up to 60°C with the standard back-up heater of ›› Both functions can be used individually or in
the heat pump module. combination to provide the best efficiency and
maximum comfort. The schedule function can
High hot water volumes heat the tank during the night, with the low
electricity tariff, up to a relatively low temperature
The following volumes can be achieved with only one (e.g. 50°C without electrical assistance).
heat-up cycle. When higher hot water consumption occurs
during the day (lowering the tank temperature to
›› Hot water volume of 300l available at 40°C the minimum reheat temperature) the heat pump
(sufficient for six showers) without electrical will switch automatically to domestic hot water
assistance (260l tank, tank temperature 50°C, heating with the reheat function to guarantee
cold water temperature 10°C, one heat-up cycle). the constant availability of hot water. Thanks to
›› Hot water volume can be increased to 375l using the large coil surface of the tank (1.56m2) heating
the standard back-up heater (260l tank, tank the tank with the schedule or reheat functions
temperature up to 60°C). occurs very quickly.

26
Integrated floor standing unit

d. Quick and easy commissioning


At the first start-up, a quick configuration wizard Before the actual test-run of the unit, an actuator test
will guide you smoothly through the commissioning mode allows all the wired components to be activated
process. Via a series of short questions, the set-up of one by one. This makes it easy to do a quick and easy
basic parameters will automatically be completed. check of all connections and wiring to ensure correct
Fine-tuning these parameters remains possible using operation. An automatic screed-drying function can
the menu-based navigation. As a result of the quick be activated: it proceeds through a gradual heat-up
configuration wizard, only the parameter settings of an under-floor heating system to avoid cracks in
relevant to the installation are shown in the menus. the floor during first use. Individual and easy-to-
The irrelevant parameters will be hidden and thus programme schedule timers – for heating, cooling,
inaccessible. domestic hot water operation and recirculation,
noise-sensitive operation and electrical booster
You can download the parameters to a PC as heating – adjust operation to match the end-user’s
a back-up or for duplication on similar installations. typical daily schedule. After the commissioning, you
If preferred, you can prepare the parameter settings can restrict access to the installer’s menu (manually
beforehand and upload them to the unit during or automatically after one hour) to avoid wrong
commissioning. manipulation of the unit by the end-user.

e. Easy serviceability Graphical screen


with backlight

In case something goes wrong, full-text error


messages guide the end-user to take appropriate
action to try and resolve the problem. If the problem
persists and a site intervention is necessary,
the service engineer will be able to review the last
20 error occurrences, for simple diagnosis of
the problem. On/Off
Info
Confirm
Detailed information on the operational conditions of
Home Menu back
the unit – such as the running hours of the different
elements, operating temperatures or number of starts
– can easily be read out from the extended end-user’s
menu. Navigational buttons

f. Room temperature control functionality


The user interface itself is equipped with Room thermostat:
a temperature sensor and can be installed remotely
from the Daikin Altherma low temperature indoor unit. The Daikin user interface can be installed in
the living room using the room thermostat function,
›› Installed on the unit: it allows quick and easy which can additionally lower or raise the set-point
access to the unit’s operating information and water temperature depending on the actual room
settings. temperature, to even better match the set-point room
›› Installed remotely (e.g. living room): it also acts temperature.
as a room thermostat – but with advanced
features that provide more stable room
temperatures, increased efficiency and
operation life cycle. A second optional interface
can still be installed on the unit for service
purposes.

27
2.
Integrated solar unit and domestic
hot water tank

maximising
renewable energy
and offering top
comfort for hot
water preparation

28
Best seasonal efficiencies

The integrated solar unit uses free


energy from the sun to provide
domestic hot water and space
heating support. Solar energy and
heat pumps complement each other
ideally in this application. Depending
on your customer’s needs, you can
offer an a pressureless (drain-back)
or pressurised solar system. The
integrated solar unit based on a
lightweight plastic tank and can be
combined with a secondary heat
source. And end users can control the
unit easily via a smartphone app.

29
Integrated solar unit

a. Solar support of domestic hot water and heating with


unpressurised (drain-back) or pressurised solar system
The integrated solar unit uses free energy The graphic shows when and how much
from the sun to produce domestic hot water the solar system supports the hot water and heating
and space heating. generation.

Thanks to the extremely high efficiency of our flat Combined with a heat pump, which also exploits
solar collector up to 80% of solar energy can be regenerative ambient energy, the use of ancillary
converted into usable heat. In this application solar energy is reduced to an absolute minimum – saving
energy and heat pumps complement each other costs for your customer.
ideally: the heat pump adds the required amount of
heat to the system to meet the demand.

kWh

3.000

2.500

2.000

1.500

1.000

500

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Solar energy utilisation for hot water and heating


Heat pump (environmental heat)
Auxiliary energy

Offer a drain-back or pressurised system gradient is not possible, then a pressurised solar
depending on your customers‘ needs. system is a better solution.

Drain-back solar system (with EHSH(X)-A) Pressurised solar system (with EHSH(X)B-A)
If the constructional conditions permit, recommend The pressurised solar system is easy to install and
the direct drain-back system. In this system, the suitable for any application, in any building. It
water in the storage tank is supplied directly and operates efficiently and safely at all pipe lengths
without heat exchanger to the solar collectors, and feed heights. The structure of the solar thermal
heated and then stored. This process considerably storage tank is engineered so that an additional plate
increases the efficiency of the entire system, heat exchanger is not necessary. A bivalent heat
especially the solar collectors. Because the system exchanger for pressurised solar or other heat sources
is not pressurised, there is no need for an expansion is already incorporated, making the system simple
tank, pressure relief valve, pressure gauge or heat and flexible.
exchanger.

A fully-automatic controller independently manages


the solar system to provide optimum use of solar
energy. The solar collectors are only filled if there
is sufficient energy from the sun, and if the thermal
storage tank can absorb the heat. When energy from
the sun is insufficient, or the thermal storage tank can ON ON

not absorb more heat, then the feed pump switches


off, and the entire solar system drains into the
thermal storage tank. Because of this process, this
system does not require antifreeze. The connection
pipes in the building and on the roof must be
installed with a constant gradient. If a constant Unpressurised solar system Pressurised solar system

30
Integrated solar unit

Excellent package label ratings with solar


Hooking up a solar thermal system is the most effective way to reach a higher
overall system efficiency class. The EKHWP-B domestic hot water tank is already
optimised for hooking up with a solar thermal system and in combination with
a solar collector, this system will become your own personal solar heater.

b. Lightweight tank with exceptional hygienic benefits


Using state-of-the-art technology, the integrated hygiene benefits have been confirmed in
domestic hot water tank is water-hygienic. an extensive study by the Hygiene Institute at
Thanks to the flow-through design, legionella the University of Tübingen – ensuring your
bacteria cannot grow, thus eliminating the need for installation is a safe one.
a thermal disinfection cycle. The exceptional water

c. Bivalent option: combinable with


a secondary heat source (EHSH(X)B-A only)
Heat from other sources can also be efficiently stored hot water generation. If you are not installing a solar
in the indoor unit. The solar system can be supported system from the beginning, it can be fitted quickly
by oil-fired and gas-fired boilers, pellet-fired boilers and easily at any time afterwards.
or wood-fired stoves with boilers for heating and

d. Easy app control


1. Control with the app

Simple, consistent handling can be carried out via


a smartphone app. You’ll find it easy to use, thanks to
the intuitive menu navigation and control.

2. Clear display and easy modification

The display shows values and parameters in clear


text. All operating modes, timer programmes and
operating parameters can be set and modified
quickly.

3. Simple controller for easy regulation

The water temperature for heating is regulated


according to the outdoor temperature.
The controller automatically detects winter and
summer, and switches the heating mode on and off
to suit demand. The controller is easy and intuitive
to operate and can be extended with a room
controller, allowing the end user to conveniently
control and monitor the heating system.
31
3.
Wall mounted unit

offering flexibility
for installation and
domestic hot water
connection

32
For some of your customers
the alternative set-up of
the wall-mounted indoor
unit will be the perfect
solution. The indoor unit
– including all hydraulic
components – can be
combined with a separate
domestic hot water tank.

33
Wall mounted unit

Heat exchanger

Water pump PCB board

Expansion vessel

a. Flexible solutions

1. No domestic hot water is required


in combination with the Daikin Altherma
system

›› No need to look for third-party components. All


hydraulic components are included in the heat
pump unit (circulating pump, expansion vessel,
back-up heater, etc.).
›› Easy serviceability: all hydraulic components and
the PCB board are accessible from the front.
›› Very compact: 890 mm (height) x 480 mm (width)
x 344 mm (depth).
›› Only a small installation space needed: almost no
side clearances are required.
›› Modern design: easily fits with other modern
household appliances.

2. W
 hen combined with a separate domestic
hot water tank is needed.

The domestic hot water tank is connectable to

›› EKHWS stainless steel tank: 150l, 200l or 300l.


›› EKHWE enameled tank: 150l, 200l or 300l.

34
Wall mounted unit

Excellent package label ratings with solar


Hooking up a solar thermal system is the most effective way to reach a higher
overall system efficiency class. The EKHWP-B domestic hot water tank is already
optimised for hooking up with a solar thermal system and in combination with
a solar collector, this system will become your own personal solar heater.

3. When a solar connection Pressurised solar system


for hot water is required: ›› System is filled with heat transfer fluid with
the correct amount of antifreeze to avoid freezing
Averaged over an entire year, the sun delivers half in winter.
of the energy we need to bring our domestic hot ›› System is pressurised.
water up to the desired temperature. High efficiency ›› Operates safely and efficiently with any length of
collectors with highly selective coating transform pipe or feed height.
all the short-wave solar radiation into heat. The ›› A bivalent heat exchanger makes the system
collectors can be mounted on virtually any kind of highly flexible.
roof (on roof, in roof, flat roof ).

Drain-back solar system


›› The simplest and most efficient system.
›› The solar collectors are only filled with water when
there is enough solar heat.
›› The pump switches on briefly and fills the
collectors with storage tank water.
›› The fully-automatic controller manages the ON ON

solar system independently to provide optimum


utilisation of the solar energy
›› The system drains the water to the storage tank
when not needed.
›› No expansion tank, pressure relief valve,
pressure gauge, heat exchanger and antifreeze Drain-back Pressurised
required. solar system solar system

35
Wall mounted unit

b. Quick and easy commissioning

At the first start-up, a quick configuration wizard ›› Before the actual test-run of the unit, an actuator
will guide you smoothly through the commissioning test mode allows all the wired components to
process. Through a series of short questions, be activated one by one. This permits a quick and
the set-up of basic parameters will automatically be easy check of all connections and wiring to ensure
completed. You can fine-tune these parameters using correct operation.
the menu-based navigation. The quick configuration ›› You can activate an automatic screed-drying
wizard ensures that only the parameter settings function to proceed through a gradual heat-up of
relevant to the installation will be shown in the menus. an under-floor heating system to avoid cracks in
The irrelevant parameters remain hidden and thus the floor during first use.
inaccessible. ›› Individual and easy-to-programme schedule
timers – for heating, cooling, domestic hot
You can download the parameters to a PC as water operation and recirculation, noise-sensitive
a back-up, or for duplication on similar installations. operation and electrical booster heating – will
If preferred, you can prepare the parameter settings adjust operation to match the end-user’s typical
beforehand and upload them to the unit during daily schedule.
commissioning. ›› After the commissioning, access to the installer’s
menu can be restricted (manually or automatically
after one hour) to avoid wrong manipulation of
the unit by the end-user.

36
Wall mounted unit

c. Easy serviceability

If something goes wrong, full-text error messages Graphical screen


will guide the end-user to take appropriate action to with backlight
try and resolve the problem. If the problem persists
and a site intervention is necessary, the service
engineer will be able to review the last 20 error
occurrences – for easy diagnosis of the problem.

Detailed information on the operational


conditions of the unit – such as the running hours
of the different elements, operating temperatures or
number of starts – can easily be read out from
the extended end-user’s menu. On/Off
Info
Confirm

Home Menu back

Navigational buttons

d. Room temperature control functionality

The user interface itself is equipped with


a temperature sensor and can be installed remotely
from the Daikin Altherma low temperature indoor unit.

›› Installed on the unit, it will allow quick and easy


access to the unit’s operating information and
settings.
›› Installed remotely (e.g. in a living room) it will also
act as a room thermostat with more advanced
features than a standard room thermostat,
resulting in more stable room temperatures,
increased efficiency and operation life cycle.
A second optional interface can still be installed
on the unit for service purposes.

37
4.
Monobloc outdoor unit,

designed for
low temperature
applications

38
Daikin Altherma
low temperature monobloc has
been designed with installers
in mind. The result is our most
compact monobloc ever,
all-in-one air-water heat pump
– small, light and easy to handle.

39
Daikin Altherma low temperature monobloc

a. A natural fit

1. All hydraulic components are combined Wiring centre


in the outdoor unit

Available in 5kW and 7kW models, the new Daikin


Altherma LT monobloc requires only a controller
indoors, when space heating is needed For use
of both space heating and domistic hot water, a
wiring centre is added. And the outdoor unit can be
installed almost anywhere, under a window sill, or in
the smallest of gardens. So it’s a natural fit for new
build and renovation projects alike.

2. The space-saving design is ideal for homes


where space is limited

›› The outdoor unit includes all hydraulic

735 mm
components
›› Smallest installed volume in the market:
H735 x W1085 x D360 mm – only 80 kg
›› The separate installation of controller and wiring
centre allows a flexible installation in the house.

3. Everything you need from one source

The Daikin Altherma monobloc works efficiently


1085 mm mm
with Daikin’s range of under-floor heating, radiators 360
and fan convectors and can be combined with solar
thermal systems. So you can count on Daikin for your
entire project.

user interface
Wiring centre Domestic hot water

Hot water
Outdoor tank
unit

3 way valve

Under floor heating

40
Daikin Altherma low temperature monobloc

Hot water tank

Radiators

Outdoor unit

41
Daikin Altherma low temperature monobloc

b. Easy to install, only water connection needed from


the outdoor to the indoor

1. Easy installation out of the box,


with no refrigerant handling

The Daikin Altherma monobloc heat pump can be


installed easily. It has a sealed refrigerant circuit,
so no refrigerant handling or F-gas qualifications are
required. With only water connections to the outdoor
unit, limited wiring, and key hydraulic components
inside the unit, it works right out of the box.
This reduces the risk of installation errors and avoids
the need to buy a separate expansion vessel, pump
or isolation valves. Complete your projects with no
surprises and maximise your profits on the job.

Plate heat exchanger


Transfers the heat from the low temperature
side to the high temperature side.
Heating: Refrigerant side = High temperature
Water side = Low temperature
Flow sensor Cooling: Refrigerant side = Low temperature
Measures the flow in the water circuit. Water side = High temperature
Will stop the unit if no or a too low
flow is detected. Expansion vessel (7l)
Protects the closed water circuit from
Pressure Relief Valve excessive water pressure caused by
Helps in controlling the water pressure thermal expansion.
in the heating system. When calibrated
pressure is reached, the valve will open Manual air purge with flexible
and discharge to atmosphere. Prevents Eliminates residual air in the water circuit.
that the system reaches dangerous
levels of pressure Pump
PWM (pulse width modulation) pump is
Clip-on filter a high efficiency pump as speed is
Protects the plate heat exchanger, according to the temperature difference
pump, etc. against particles that can between the set temperature and actual
cause blockage. indoor temperature rather than fixed
speeds e.g. H/M/L

2. Easy serviceability, thanks to


user-friendly interface putting complete
control at your fingertips

In case something goes wrong, full-text error


messages guide the end-user to take appropriate
action to try and resolve the problem. If the problem
persists and a site intervention is necessary,
the service engineer will be able to review the last
20 error occurrences, for simple diagnosis of
the problem.

Detailed information on the operational conditions of


the unit – such as the running hours of the different
elements, operating temperatures or number of
starts – can easily be read out from the extended
end-user’s menu.

42
Daikin Altherma low temperature monobloc

c. High efficiency in all climates

1. Market leading energy efficiencies Example of monobloc


minimise running costs outdoor unit - space heating

Daikin Altherma monobloc is setting new standards


of efficiency with high SCOPs in all conditions
Its new inverter compressor has a wide modulation
range, giving lower minimum outputs at higher EBLQ05CAV3
ambient temperatures. So the system works in partial
load for most of the year. This reduces the load 55°C 35°C
on the compressor, minimising running costs and
maximising the system’s lifespan.
A++ A++

2. Optimised for all climates


all year round, with operation
guaranteed down to -25°C

With flow temperatures of up to 55°C even during


cold weather, Daikin Altherma monobloc delivers
higher heating capacity than any previous model 4 kW 4 kW
at lower ambient temperatures (less than 10% drop 4 kW 4 kW
off in heating capacity at -2°C), making it easier to 4 kW 5 kW
select the right heat pump. A free hanging coil 61 dB
minimises frost build up and reliable operation is
guaranteed down to -25°C outside. An optional back-
up heater is also available – for total customer peace
of mind. With just a simple annual inspection, 0 dB
you can count on the Daikin Altherma monobloc to
run reliably, year after year.

Free hanging coil

Low voltage

Water inlet High voltage

Water outlet Main power supply

43
Servicing

Servicing made easy

for long and trouble-


free operation
Daikin Altherma low temperature heat pump systems
have an unsurpassed reputation for reliability.
To ensure that your customers benefit from years of
dependable operation, our units are carefully designed
to make any necessary troubleshooting, repair and
maintenance as quick and easy as possible.

a. Troubleshooting
1. A smart system controller facilitates
diagnostics and serviceability

In case something goes wrong, full-text error


messages guide the end-user to take appropriate
action to try and resolve the problem. If the problem
persists and a site intervention is necessary,
the service engineer will be able to review the last
20 error occurrences, for simple diagnosis of
the problem.

Detailed information on the operational conditions


of the unit – such as the running hours of
the different elements, operating temperatures or
number of starts – can easily be read out from
PAS OP beeld LR
the extended end-user’s menu. The 60 different full-
text error codes provide the servicing engineer with
very detailed information about the functioning of
the unit, facilitating a rapid resolution of the problem.

44
Servicing

b. Repair
1. To facilitate repairs, units are carefully
designed for easy accessibility

In designing our indoor and outdoor Daikin Altherma


low temperature heat pump systems we have made
sure you can access all piping and electronics to
make repairs as easily and rapidly as possible.

›› All water and refrigerant connections are


designed in such a manner that they are easy to
connect and accessed.
›› This makes servicing easy and avoids the risk of
damage.

2. Full support from Daikin is offered for


spare parts and assistance

If repair becomes necessary, Daikin backs you up


with full support regarding spare parts and responsive,
expert assistance in accordance to the standard
procedures for refrigerant and pipe work.

Geen HR beeld
gekregen

c. Maintenance
1. State-of-the-art design and exceptional 2. Annual maintenance tasks to keep
build quality ensure that maintenance the system running smoothly
procedures are kept to the minimum
›› To ensure that your customer’s Altherma low
›› The state-of-the-art design and exceptional temperature system operates smoothly and at the
build quality of our indoor and outdoor systems highest possible efficiency levels, here is
ensure that maintenance procedures are kept a list of the key maintenance items that should be
to a minimum – and can be done quickly and checked on an annual basis.
efficiently. The easy-access design will certainly ›› Fluid pressure of space heating circuit
make your job easier. ›› Relief valve hose
›› Pressure relief valve of space heating circuit
›› Pressure relief valve of domestic hot water tank
›› Filters
›› Draining of the domestic hot water tank
›› Anode
›› Descaling and chemical disinfection
›› Switch box
›› Domestic hot water tank booster heater
(in case non-integrated tank)

45
Heat pump

in practice
a. Example of running cost and CO2 comparison
Daikin provides a web-based tool you and your floor area, number of people), a comparison is made
customer can use to get a quick estimation of savings between the Daikin Altherma heat pump system and
on both running costs and CO2 emissions. Based on a traditional heating systems, including space heating
few inputs from your customer (location, house type, and domestic hot water heating. This is available for
both new builds and refurbishment applications.
Energy savings calculator
* Simulation for a new build
detached house (room in roof )
Go to ecocalc.daikin.eu and see how a Daikin Altherma with low temperature emitters,
heat pump saves on both running costs and CO2 for 4 people and a heated surface
emission. of 125m2, taking into account
Belgian climate conditions, an
electricity price of 0.17EUR/kWh
and a gas price of 0.06 EUR/kWh.

b. Simulation software
The Daikin Altherma simulation software can provides detailed information for you and your
evaluate every specific application and appropriate customer, about the expected outcome of
heat pump selection, taking into account the needs of the specified Daikin Altherma unit, for its specific
the building and specific climate data. You simply application and climate:
provide the following data, and the software does
the rest! ›› Seasonal efficiency of the heat pump system
›› Amount of back-up heater operation
›› House application: heat/cool load, ›› Energy consumption and energy cost per month
water temperatures, power supply ›› Savings on running costs compared to traditional
›› Climate conditions: location, design temperature heating systems
›› Domestic hot water requirements: tank volume,
material, solar connection All this information in summarised in a detailed report.
›› Preferences: “heating off“ temperature, night
setback function

Based on the specific house and location details,


the software provides a full dimensioning – assuring
your correct material selection.

As well as a full material selection, the software

c. Free Access Website


Daikin helps its partners to meet their obligations re- labels. Comprehensive information materials and
garding the Ecodesign Directive and energy labelling. training courses at our Info Centers across Europe pro-
Labels and product fiches for each individual product, vide in-depth expertise and ensure that our specialist
as well as for combined packages, are part of the partners can advise their customers competently on all
standard delivery. As of September 2015, they will be issues around the energy efficiency of heaters.
available as downloads at any time from the Energy
Label Generator at
www.daikineurope.com/energylabel/lot1_2/Daikin.
With our system configurator, individual solutions can
be put together quickly and easily using Daikin system
components – including corresponding package
46
Technical

specifications
1. Floor standing unit

EHVH-CB + ERLQ-CV3/CW1

08S18CB3V / 08S18CB3V / 11S18CB3V / 16S18CB3V / 16S18CB3V / 11S18CB3V / 16S18CB3V / 16S18CB3V /


04S18CB3V
Efficiency data EHVH + ERLQ 08S26CB9W 08S26CB9W 11S26CB9W 16S26CB9W 16S26CB9W 11S26CB9W 16S26CB9W 16S26CB9W
+ 004CV3
+ 006CV3 + 008CV3 + 011CV3 + 014CV3 + 016CV3 + 011CW1 + 014CW1 + 016CW1
Heating capacity Nom. kW 4.40 / 4.03 6.00 / 5.67 7.40 / 6.89 11.20 / 11.00 14.50 / 13.60 16.00 / 15.20 11.20 / 11.00 14.50 / 13.60 16.00 / 15.20
Power input Heating Nom. kW 0.87 / 1.13 1.27 / 1.59 1.66 / 2.01 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66 3.42 / 4.21 3.37 / 4.10 3.76 / 4.66
COP 5.04 / 3.58 4.74 / 3.56 4.45 / 3.42 4.60 / 2.75 / 3.55 / 2.10 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09 4.60 / 2.75 / 3.55 / 2.10 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09
Domestic hot water General Declared load profile L XL L XL L XL L XL L XL L XL L XL L XL
heating Average climate ηwh (water heating efficiency) % 95 86 90 86 90 87 98 87 98 87 98 87 98 87 98 87 98
Water heating energy efficiency class A
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 125 124 126 124 120 122 124 120 122
outlet 55°C SCOP 3.20 3.17 3.23 3.18 3.07 3.13 3.18 3.07 3.13
Seasonal space heating eff. class A++ A+ A++ A+
Average climate water General ηs (Seasonal space heating efficiency) % -
outlet 35°C SCOP 4.52 4.27 4.34 3.95 3.83 3.84 3.95 3.83 3.84
Seasonal space heating eff. class -

11S18CB3V 11S18CB3V /
Indoor Unit EHVH 04S18CB3V 08S18CB3V /08S26CB9W 16S18CB3V /16S26CB9W 16S18CB3V / 16S26CB9W
11S26CB9W 11S26CB9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728
Weight Unit kg 116 117 127 117 127 117 126 118 128 118 128 117 126 118 128 118 128
Tank Water volume l 180 260 180 260 180 260 180 260 180 260 180 260 180 260 180 260
Maximum water temperature °C 65
Maximum water pressure bar 10
Corrosion protection Anode
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Domestic hot water Water side Min.~Max. °C 25~60 25~60 / 60
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 42 44 42 44
Sound pressure level Nom. dBA 28 30 28 30

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20

47
Specifications

EHVH-CB + ERHQ-BV3/ERHQ-BW1

11S26CB9W 11S18CB3V 16S26CB9W + 16S18CB3V 16S26CB9W + 16S18CB3V 11S26CB9W 11S18CB3V 16S26CB9W + 16S18CB3V 16S26CB9W 16S18CB3V
Efficiency data EHVH + ERHQ
+ 011BV3 + 011BV3 014BV3 + 014BV3 016BV3 + 016BV3 + 011BW1 + 011BW1 014BW1 + 014BW1 + 014BV3 + 014BV3
Heating capacity Nom. kW 11.20 / 10.30 14.00 / 13.10 16.00 / 15.20 11.32 / 10.98 14.50 / 13.57 16.05 / 15.11
Power input Heating Nom. kW 2.55 / 3.17 3.26 / 4.04 3.92 / 4.75 2.63 / 3.24 3.42 / 4.21 3.82 / 4.69
COP 4.39 / 3.25 4.29 / 3.24 4.08 / 3.20 4.30 / 3.39 4.24 / 3.22 4.20 / 3.22
Domestic hot water General Declared load profile XL L XL L XL L XL L XL L XL L
heating Average climate ηwh (water heating efficiency) % 95 91 95 91 95 91 87 84 87 84 87 84
Water heating energy efficiency class A
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118
outlet 55°C SCOP 2.93 2.91 2.94 3.00 2.98 3.03
Seasonal space heating eff. class A+
Average climate water General ηs (Seasonal space heating efficiency) % -
outlet 35°C SCOP 3.02 3.32 3.25 3.24 3.14 3.10
Seasonal space heating eff. class -

Indoor Unit EHVH 11S26CB9W 11S18CB3V 16S26CB9W 16S18CB3V 16S26CB9W 16S18CB3V 11S26CB9W 11S18CB3V 16S26CB9W 16S18CB3V 16S26CB9W 16S18CB3V
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728
Weight Unit kg 126 117 127 118 127 118 126 117 127 118 127 118
Tank Water volume l 260 180 260 180 260 180 260 180 260 180 260 180
Maximum water temperature °C 65
Maximum water pressure bar 10
Corrosion protection Anode
Operation range Heating Water side Min.~Max. °C 15~55
Domestic hot water Water side Min.~Max. °C 25~60 / 60
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 42 44 42 44
Sound pressure level Nom. dBA 28 30 28 30

Outdoor Unit ERHQ 011BV3 014BV3 016BV3 011BW1 014BW1 016BW1


Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320
Weight Unit kg 102 108
Compressor Quantity 1
Type Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~46.0
Domestic hot water Min.~Max. °CDB -20~35
Refrigerant Type R-410A
Charge kg 2.7 3.0
TCO₂eq 5.6 6.3
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 64 66 64 66
Cooling Nom. dBA 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 49 51 53 51 52
Cooling Nom. dBA 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 32 20

48
Specifications

EHVX-CB + ERLQ-CV3/ERLQ-CW1

08S18CB3V / 08S18CB3V / 11S18CB3V / 16S18CB3V / 16S18CB3V / 11S18CB3V / 16S18CB3V / 16S18CB3V /


04S18CB3V
Efficiency data EHVX + ERLQ 08S26CB9W 08S26CB9W 11S26CB9W 16S26CB9W 16S26CB9W 11S26CB9W 16S26CB9W 16S26CB9W
+ 004CV3
+ 006CV3 + 008CV3 + 011CV3 + 014CV3 + 016CV3 + 011CW1 + 014CW1 + 016CW1
Heating capacity Nom. kW 4.40 / 4.03 6.00 / 5.67 7.40 / 6.89 11.20 / 11.00 14.50 / 13.60 16.00 / 15.20 11.20 / 11.00 14.50 / 13.60 16.00 / 15.20
Cooling capacity Nom. kW 4.1 / 4.2 5.9 / 4.8 6.2 / 5.4 12.1 / 11.7 12.7 / 12.6 13.8 / 13.1 12.1 / 11.7 12.7 / 12.6 13.8 / 13.1
Power input Heating Nom. kW 0.87 / 1.13 1.27 / 1.59 1.66 / 2.01 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66
Cooling Nom. kW 0.90 / 1.80 1.51 / 2.07 1.64 / 2.34 3.05 / 4.31 3.21 / 5.08 3.74 / 5.73 3.05 / 4.31 3.21 / 5.08 3.74 / 5.73
COP 5.04 / 3.58 4.74 / 3.56 4.45 / 3.42 4.60 / 2.75 / 3.55 / 2.10 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09 4.60 / 2.75 / 3.55 / 2.10 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09
EER 4.55 / 2.32 3.89 / 2.34 3.79 / 2.29 3.98 / 2.72 3.96 / 2.47 3.69 / 2.29 3.98 / 2.72 3.96 / 2.47 3.69 / 2.29
Domestic hot water General Declared load profile L XL L XL L XL L XL L XL L XL L XL L XL
heating Average climate ηwh (water heating efficiency) % 95 86 90 86 90 87 98 87 98 87 98 87 98 87 98 87 98
Water heating energy efficiency class A
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 125 124 126 124 120 122 124 120 122
outlet 55°C SCOP 3.20 3.17 3.23 3.18 3.07 3.13 3.18 3.07 3.13
Seasonal space heating eff. class A++ A+ A++ A+
Average climate water General ηs (Seasonal space heating efficiency) % -
outlet 35°C SCOP 4.52 4.27 4.34 3.95 3.83 3.84 3.95 3.83 3.84
Seasonal space heating eff. class -

11S18CB3V / 11S18CB3V /
Indoor Unit EHVX 04S18CB3V 08S18CB3V / 08S26CB9W 16S18CB3V / 16S26CB9W 16S18CB3V / 16S26CB9W
11S26CB9W 11S26CB9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728
Weight Unit kg 117 119 129 119 129 119 128 120 130 120 130 119 128 120 130 120 130
Tank Water volume l 180 260 180 260 180 260 180 260 180 260 180 260 180 260 180 260
Maximum water temperature °C 65
Maximum water pressure bar 10
Corrosion protection Anode
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Cooling Water side Min.~Max. °C 5~22
Domestic hot water Water side Min.~Max. °C 25~60 25~60 / 60
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 42 44 42 44
Sound pressure level Nom. dBA 28 30 28 30

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20

49
Specifications

EHVX-CB + ERHQ-BV3/ERHQ-BW1

11S18CB3V 11S26CB9W 16S18CB3V 16S26CB9W + 16S18CB3V 16S26CB9W + 11S18CB3V 11S26CB9W 16S18CB3V 16S26CB9W + 16S18CB3V 16S26CB9W
Efficiency data EHVX + ERHQ
+ 011BV3 + 011BV3 + 014BV3 014BV3 + 016BV3 016BV3 + 011BW1 + 011BW1 + 014BW1 014BW1 + 016BW1 + 016BW1
Heating capacity Nom. kW 11.20 / 10.30 14.00 / 13.10 16.00 / 15.20 11.32 / 10.98 14.50 / 13.57 16.05 / 15.11
Cooling capacity Nom. kW 13.9 / 10.0 17.3 / 12.5 17.8 / 13.1 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1
Power input Heating Nom. kW 2.55 / 3.17 3.26 / 4.04 3.92 / 4.75 2.63 / 3.24 3.42 / 4.21 3.82 / 4.69
Cooling Nom. kW 3.86 / 3.69 5.86 / 5.69 6.87 / 5.95 4.53 / 4.31 5.43 / 5.08 6.16 / 5.73
COP 4.39 / 3.25 4.29 / 3.24 4.08 / 3.20 4.30 / 3.39 4.24 / 3.22 4.20 / 3.22
EER 3.60 / 2.71 2.95 / 2.32 2.59 / 2.20 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29
Domestic hot water General Declared load profile L XL L XL L XL L XL L XL L XL
heating Average climate ηwh (water heating efficiency) % 91 95 91 95 91 95 84 87 84 87 84 87
Water heating energy efficiency class A
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118
outlet 55°C SCOP 2.93 2.91 2.94 3.00 2.98 3.03
Seasonal space heating eff. class A+
Average climate water General ηs (Seasonal space heating efficiency) % -
outlet 35°C SCOP 3.02 3.32 3.25 3.24 3.14 3.10
Seasonal space heating eff. class -

Indoor Unit EHVX 11S18CB3V 11S26CB9W 16S18CB3V 16S26CB9W 16S18CB3V 16S26CB9W 11S18CB3V 11S26CB9W 16S18CB3V 16S26CB9W 16S18CB3V 16S26CB9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728
Weight Unit kg 119 128 120 129 120 129 119 128 120 129 120 129
Tank Water volume l 180 260 180 260 180 260 180 260 180 260 180 260
Maximum water temperature °C 65
Maximum water pressure bar 10
Corrosion protection Anode
Operation range Heating Water side Min.~Max. °C 15~55
Cooling Water side Min.~Max. °C 5~22
Domestic hot water Water side Min.~Max. °C 25~60 / 60
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 42 44 42 44
Sound pressure level Nom. dBA 28 30 28 30

Outdoor Unit ERHQ 011BV3 014BV3 016BV3 011BW1 014BW1 016BW1


Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320
Weight Unit kg 102 108
Compressor Quantity 1
Type Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~46.0
Domestic hot water Min.~Max. °CDB -20~35
Refrigerant Type R-410A
Charge kg 2.7 3.0
TCO₂eq 5.6 6.3
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 64 66 64 66
Cooling Nom. dBA 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 49 51 53 51 52
Cooling Nom. dBA 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 32 20

50
Specifications

EHVZ-CB3V + ERLQ-CV3/ERLQ-CW1

04S18CB3V + 08S18CB3V + 08S18CB3V + 16S18CB3V + 16S18CB3V + 16S18CB3V + 16S18CB3V + 16S18CB3V + 16S18CB3V +


Efficiency data EHVZ + ERLQ
004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Heating capacity Nom. kW 4.40 / 4.03 6.00 / 5.67 7.40 / 6.89 11.20 / 11.00 14.40 / 13.50 15.90 / 15.10 11.20 / 11.00 14.40 / 13.50 15.90 / 15.10
Power input Heating Nom. kW 0.87 / 1.13 1.27 / 1.59 1.66 / 2.01 2.43 / 3.10 3.39 / 4.12 3.77 / 4.67 2.43 / 3.10 3.39 / 4.12 3.77 / 4.67
COP 5.04 / 3.58 4.74 / 3.56 4.45 / 3.42 4.60 / 2.75 / 3.55 / 2.10 4.24 / 2.61 / 3.28 / 2.05 4.22 / 2.61 / 3.23 / 2.07 4.60 / 2.75 / 3.55 / 2.10 4.24 / 2.61 / 3.28 / 2.05 4.22 / 2.61 / 3.23 / 2.07
Pump Additional Zone Nominal ESP unit (*RLQ*C*)
Heating kPa 52.3 / 55.4 40.6 / 43.3 28.3 / 32.7 26.2 / 28.3 25.0 26.2 / 28.3 25.0
Pump Main Zone Nominal ESP unit (*RLQ*C*)
Heating kPa 48.6 / 51.9 39.5 / 42.3 26.4 / 31.2 18.2 / 20.7 25.0 18.2 / 20.7 25.0
Domestic hot water General Declared load profile L
heating Average climate ηwh (water heating efficiency) % 95 86 87
Water heating energy efficiency class A
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 125 124 126 124 120 122 124 120 122
outlet 55°C SCOP 3.20 3.17 3.23 3.18 3.07 3.18 3.07
Seasonal space heating eff. class A++ A+ A++ A+
Average climate water General ηs (Seasonal space heating efficiency) % -
outlet 35°C SCOP 4.52 4.27 4.34 3.95 3.83 3.84 3.95 3.83 3.84
Seasonal space heating eff. class -

Indoor Unit EHVZ 04S18CB3V 08S18CB3V 16S18CB3V


Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728
Weight Unit kg 121 122 121
Tank Water volume l 180
Maximum water temperature °C 65
Maximum water pressure bar 10
Corrosion protection Anode
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Domestic hot water Water side Min.~Max. °C 25~60 25~60 / 60
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 42 44
Sound pressure level Nom. dBA 28 30

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20

51
Specifications

EHVZ-CB3V + ERHQ-BV3/BW1

16S18CB3V 16S18CB3V + 16S18CB3V + 16S18CB3V + 16S18CB3V + 16S18CB3V +


Efficiency data EHVZ + ERHQ
+ 011BV3 014BV3 016BV3 011BW1 014BW1 016BW1
Heating capacity Nom. kW 11.20 / 10.30 14.00 / 13.10 16.00 / 15.20 11.32 / 10.98 14.50 / 13.57 16.05 / 15.11
Power input Heating Nom. kW 2.55 / 3.17 3.26 / 4.04 3.92 / 4.75 2.63 / 3.24 3.42 / 4.21 3.82 / 4.69
COP 4.39 / 3.25 4.29 / 3.24 4.08 / 3.20 4.30 / 3.39 4.24 / 3.22 4.20 / 3.22
Pump Additional Zone Nominal ESP unit (*RHQ*B*)
Heating kPa 26.2 / 35.0 25.0 24.8 / 28.3 25.0
Pump Main Zone Nominal ESP unit (*RHQ*B*)
Heating kPa 18.2 / 28.8 25.0 16.4 / 20.7 25.0
Domestic hot water General Declared load profile L
heating Average climate ηwh (water heating efficiency) % 91 84
Water heating energy efficiency class A
Space heating Average climate General ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118
water outlet 55°C SCOP 2.93 2.91 2.94 3.00 2.98 3.03
Seasonal space heating eff. class A+
Average climate General ηs (Seasonal space heating efficiency) % -
water outlet 35°C SCOP 3.02 3.32 3.25 3.24 3.14 3.10
Seasonal space heating eff. class -

Indoor Unit EHVZ 16S18CB3V


Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728
Weight Unit kg 121
Tank Water volume l 180
Maximum water temperature °C 65
Maximum water pressure bar 10
Corrosion protection Anode
Operation range Heating Water side Min.~Max. °C 15~55
Domestic hot water Water side Min.~Max. °C 25~60 / 60
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 44
Sound pressure level Nom. dBA 30

Outdoor Unit ERHQ 011BV3 014BV3 016BV3 011BW1 014BW1 016BW1


Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320
Weight Unit kg 102 108
Compressor Quantity 1
Type Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~46.0
Domestic hot water Min.~Max. °CDB -20~35
Refrigerant Type R-410A
Charge kg 2.7 3.0
TCO₂eq 5.6 6.3
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 64 66 64 66
Cooling Nom. dBA 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 49 51 53 51 52
Cooling Nom. dBA 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 32 20

52
Specifications

2. Integrated solar unit

EHSH-A + ERLQ-CV3/ERLQ-CW1

04P30A + 08P50A + 08P30A + 08P30A + 08P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A +
Efficiency data EHSH + ERLQ
004CV3 006CV3 006CV3 008CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Heating capacity Nom. kW 4.53 / 3.98 / 4.26 / 3.47 6.06 / 5.78 / 5.14 / 4.60 7.78 / 7.27 / 5.53 / 5.51 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05
Power input Heating Nom. kW 0.87 / 1.04 / 1.49 / 0.85 1.30 / 1.58 / 1.88 / 1.26 1.69 / 2.04 / 1.98 / 1.56 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93
COP 5.23 / 3.84 / 2.85 / 4.07 4.65 / 3.66 / 2.73 / 3.64 4.60 / 3.57 / 2.78 / 3.54 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15
Domestic hot water General Declared load profile L XL L XL
heating Average climate ηwh (water heating efficiency) % 103 102 98 90 96 83
Water heating energy efficiency class A
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 130 125 127 125 126 125 126 125
outlet 55°C Seasonal space heating eff. class A++
Average climate water General ηs (Seasonal space heating efficiency) % -
outlet 35°C Seasonal space heating eff. class -

Indoor Unit EHSH 04P30A 08P50A 08P30A 08P50A 16P50A


Casing Colour Traffic white (RAL9016) / Dark grey (RAL7011)
Material Impact resistant polypropylene
Dimensions Unit HeightxWidthxDepth mm 1,945x615x595 1,945x790x790 1,945x615x595 1,945x790x790
Weight Unit kg 87 114 87 114 116
Tank Water volume l 300 500 300 500
Maximum water temperature °C 85
Operation range Heating Ambient Min.~Max. °C -25~25 -25~35
Water side Min.~Max. °C 15~55 15~55 15~55 15~55
Domestic hot water Ambient Min.~Max. °CDB -25~35
Water side Min.~Max. °C 25~55
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq -
Control Electronic expansion valve / Inverter
GWP -
Sound power level Nom. dBA 40
Sound pressure level Nom. dBA 28

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20

53
Specifications

EHSHB-A + ERLQ-CV3/ERLQ-CW1

04P30A + 08P30A + 08P50A + 08P30A + 08P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A +
Efficiency data EHSHB + ERLQ
004CV3 006CV3 006CV3 008CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Heating capacity Nom. kW 4.53 / 3.98 / 4.26 / 3.47 6.06 / 5.78 / 5.14 / 4.60 7.78 / 7.27 / 5.53 / 5.51 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05
Power input Heating Nom. kW 0.87 / 1.04 / 1.49 / 0.85 1.30 / 1.58 / 1.88 / 1.26 1.69 / 2.04 / 1.98 / 1.56 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93
COP 5.23 / 3.84 / 2.85 / 4.07 4.65 / 3.66 / 2.73 / 3.64 4.60 / 3.57 / 2.78 / 3.54 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15
Domestic hot water General Declared load profile L XL L XL - XL -
heating Average climate ηwh (water heating efficiency) % 103 98 108 90 99 - 84 - -
Water heating energy efficiency class A - A - -
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 130 125 127 - 124 - -
outlet 55°C Seasonal space heating eff. class A++ - A+ - -
Average climate water General ηs (Seasonal space heating efficiency) % - -
outlet 35°C Seasonal space heating eff. class - -

Indoor Unit EHSHB 04P30A 08P30A 08P50A 08P30A 08P50A 16P50A


Casing Colour Traffic white (RAL9016) / Dark grey (RAL7011)
Material Impact resistant polypropylene
Dimensions Unit HeightxWidthxDepth mm 1,945x615x595 1,945x790x790 1,945x615x595 1,945x790x790
Weight Unit kg 92 119 92 119 121
Tank Water volume l 300 500 300 500
Maximum water temperature °C 85
Operation range Heating Ambient Min.~Max. °C -25~25 -25~35
Water side Min.~Max. °C 15~55 15~55 15~55 15~55 15~55
Domestic hot water Ambient Min.~Max. °CDB -25~35
Water side Min.~Max. °C 25~55
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq -
Control Electronic expansion valve / Inverter
GWP -
Sound power level Nom. dBA 40
Sound pressure level Nom. dBA 28

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20

54
Specifications

EHSX-A + ERLQ-CV3/ERLQ-CW1

04P30A + 08P30A + 08P50A + 08P30A + 08P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A +
Efficiency data EHSX + ERLQ
004CV3 006CV3 006CV3 008CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Heating capacity Nom. kW 4.53 / 3.98 / 4.26 / 3.47 6.06 / 5.78 / 5.14 / 4.60 7.78 / 7.27 / 5.53 / 5.51 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05
Cooling capacity Nom. kW 4.4 / 4.0 5.2 / 4.6 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1
Power input Heating Nom. kW 0.87 / 1.04 / 1.49 / 0.85 1.30 / 1.58 / 1.88 / 1.26 1.69 / 2.04 / 1.98 / 1.56 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93
Cooling Nom. kW 1.05 / 1.41 1.43 / 1.85 4.55 / 4.30 5.44 / 5.10 6.18 / 5.72 4.55 / 4.30 5.44 / 5.10 6.18 / 5.72
COP 5.23 / 3.84 / 2.85 / 4.07 4.65 / 3.66 / 2.73 / 3.64 4.60 / 3.57 / 2.78 / 3.54 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15
EER 4.21 / 2.85 3.65 / 2.51 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29
Domestic hot water General Declared load profile L XL L XL - XL -
heating Average climate ηwh (water heating efficiency) % 103 98 102 90 96 -
Water heating energy efficiency class A -
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 132 126 128 -
outlet 55°C Seasonal space heating eff. class A++ -
Average climate water General ηs (Seasonal space heating efficiency) % -
outlet 35°C Seasonal space heating eff. class -

Indoor Unit EHSX 04P30A 08P30A 08P50A 08P30A 08P50A 16P50A


Casing Colour Traffic white (RAL9016) / Dark grey (RAL7011)
Material Impact resistant polypropylene
Dimensions Unit HeightxWidthxDepth mm 1,945x615x595 1,945x790x790 1,945x615x595 1,945x790x790
Weight Unit kg 87 114 87 114 116
Tank Water volume l 300 500 300 500
Maximum water temperature °C 85
Operation range Heating Ambient Min.~Max. °C -25~25 -25~35
Water side Min.~Max. °C 15~55 15~55 15~55 15~55 15~55
Cooling Ambient Min.~Max. °CDB 10~43
Water side Min.~Max. °C 5~22 -~-
Domestic hot water Ambient Min.~Max. °CDB -25~35
Water side Min.~Max. °C 25~55
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq -
Control Electronic expansion valve / Inverter
GWP -
Sound power level Nom. dBA 40
Sound pressure level Nom. dBA 28

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20 20

55
Specifications

EHSXB-A + ERLQ-CV3/ERLQ-CW1

04P30A + 08P30A + 08P50A + 08P30A + 08P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A
Efficiency data EHSXB + ERLQ
004CV3 006CV3 006CV3 008CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 +016CW1
Heating capacity Nom. kW 4.53 / 3.98 / 4.26 / 3.47 6.06 / 5.78 / 5.14 / 4.60 7.78 / 7.27 / 5.53 / 5.51 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05
Cooling capacity Nom. kW 4.4 / 4.0 5.2 / 4.6 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1
Power input Heating Nom. kW 0.87 / 1.04 / 1.49 / 0.85 1.30 / 1.58 / 1.88 / 1.26 1.69 / 2.04 / 1.98 / 1.56 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93
Cooling Nom. kW 1.05 / 1.41 1.43 / 1.85 4.55 / 4.30 5.44 / 5.10 6.18 / 5.72 4.55 / 4.30 5.44 / 5.10 6.18 / 5.72
COP 5.23 / 3.84 / 2.85 / 4.07 4.65 / 3.66 / 2.73 / 3.64 4.60 / 3.57 / 2.78 / 3.54 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15
EER 4.21 / 2.85 3.65 / 2.51 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29
Domestic hot water General Declared load profile L XL L XL XL
heating Average climate ηwh (water heating efficiency) % 103 98 108 90 99 84 84
Water heating energy efficiency class A A
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 132 126 128 130 127 128 130 127
outlet 55°C Seasonal space heating eff. class A++ A++
Average climate water General ηs (Seasonal space heating efficiency) % - -
outlet 35°C Seasonal space heating eff. class - -

Indoor Unit EHSXB 04P30A 08P30A 08P50A 08P30A 08P50A 16P50A


Casing Colour Traffic white (RAL9016) / Dark grey (RAL7011)
Material Impact resistant polypropylene
Dimensions Unit HeightxWidthxDepth mm 1,945x615x595 1,945x790x790 1,945x615x595 1,945x790x790
Weight Unit kg 92 119 92 119 121
Tank Water volume l 300 500 300 500
Maximum water temperature °C 85
Operation range Heating Ambient Min.~Max. °C -25~25 -25~35
Water side Min.~Max. °C 15~55 15~55 15~55 15~55 15~55
Cooling Ambient Min.~Max. °CDB 10~43
Water side Min.~Max. °C 5~22 -~-
Domestic hot water Ambient Min.~Max. °CDB -25~35
Water side Min.~Max. °C 25~55
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq -
Control Electronic expansion valve / Inverter
GWP -
Sound power level Nom. dBA 40
Sound pressure level Nom. dBA 28

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20

56
Specifications

3. Wall mounted unit

EHBH-CB + ERLQ-CV3/ERLQ-CW1

04CB3V + 08CB9W + 08CB9W + 11CB3V/9W + 16CB3V/9W+ 16CB3V/9W + 11CB3V/9W + 16CB3V/9W + 16CB3V/9W +


Efficiency data EHBH + ERLQ
004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Heating capacity Nom. kW 4.40 (1 / 4.03 (2 6.00 (1 / 5.67 (2 7.40 (1 / 6.89 (2 11.20 (1 / 11.00 (2 14.50 (1 / 13.60 (2 16.00 (1 / 15.20 (2 11.20 (1 / 11.00 (2 14.50 (1 / 13.60 (2 16.00 (1 / 15.20 (2
Power input Heating Nom. kW 0.87 (1 / 1.13 (2 1.27 (1 / 1.59 (2 1.66 (1 / 2.01 (2 2.43 (1 / 3.10 (2 3.37 (1 / 4.10 (2 3.76 (1 / 4.66 (2 3.42 (1 / 4.21 (2 3.37 (1 / 4.10 (2 3.76 (1 / 4.66 (2
COP 5.04 (1 / 4.74 (1 / 4.45 (1 / 4.60 (1 / 2.75 (3 / 4.30 (1 / 2.65 (3 / 4.25 (1 / 2.64 (3 / 4.60 (1 / 2.75 (3 / 4.30 (1 / 2.65 (3 / 4.25 (1 / 2.64 (3 /
3.58 (2 3.56 (2 3.42 (2 3.55 (2 / 2.10 (4 3.32 (2 / 2.08 (4 3.26 (2 / 2.09 (4 3.55 (2 / 2.10 (4 3.32 (2 / 2.08 (4 3.26 (2 / 2.09 (4
Domestic hot water General Declared load profile -
heating Average climate ηwh (water heating efficiency) % -
Water heating energy efficiency class -
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 125 124 126 124 120 122 124 120 122
outlet 55°C SCOP 3.20 3.17 3.23 3.18 3.07 3.13 3.18 3.07 3.13
Seasonal space heating eff. class A++ A+ A++ A+
Average climate water General ηs (Seasonal space heating efficiency) % 178 168 171 155 150 155 150
outlet 35°C SCOP 4.52 4.27 4.34 3.95 3.83 3.84 3.95 3.83 3.84
Seasonal space heating eff. class A+++ A++

08CB3V/9W 08CB3V/9W
Indoor Unit EHBH 04CB3V 11CB3V/9W 16CB3V/9W 16CB3V/9W 11CB3V/9W 16CB3V/9W 16CB3V/9W
08CB9W 08CB9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 890x480x344
Weight Unit kg 41 43 45 43 45 43 44 45 44 45 43 44 45 44 45
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Domestic hot water Water side Min.~Max. °C 25~80 25~80
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 40 41 44 41 44
Sound pressure level Nom. dBA 26 27 30 27 30

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25 (2.000~35 (2 -20 (2.000~35 (2
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 (3 66 (3 64 (3 66 (3
Cooling Nom. dBA 63 64 (4 66 (4 69 (4 64 (4 66 (4 69 (4
Sound pressure level Heating Nom. dBA 48 (3 49 (3 51 (5 52 (5 51 (5 52 (5
Cooling Nom. dBA 48 (3 49 (3 50 (3 50 (5 52 (5 54 (5 50 (5 52 (5 54 (5
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20

Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

57
Specifications

EHBH-CB + ERHQ-BW1/ERHQ-BV3

16CB9W
11CB3V + 11CB9W 16CB3V + 16CB9W 16CB3V + 16CB9W 11CB3V + 11CB9W 16CB3V + 16CB3V + 16CB9W
Efficiency data EHBH + ERHQ +
011BV3 + 011BV3 014BV3 + 014BV3 016BV3 + 016BV3 011BW1 + 011BW1 014BW1 016BW1 + 016BW1
014BW1
Heating capacity Nom. kW 11.20 / 10.30 14.00 / 13.10 16.00 / 15.20 11.32 / 10.98 14.50 / 13.57 16.05 / 15.11
Power input Heating Nom. kW 2.55 / 3.17 3.26 / 4.04 3.92 / 4.75 2.63 / 3.24 3.42 / 4.21 3.82 / 4.69
COP 4.39 / 3.25 4.29 / 3.24 4.08 / 3.20 4.30 / 3.39 4.24 / 3.22 4.20 / 3.22
Domestic hot water General Declared load profile -
heating Average climate ηwh (water heating efficiency) % -
Water heating energy efficiency class -
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118
outlet 55°C SCOP 2.93 2.91 2.94 3.00 2.98 3.03
Seasonal space heating eff. class A+
Average climate water General ηs (Seasonal space heating efficiency) % 118 130 127 123 118
outlet 35°C SCOP 3.02 3.32 3.25 3.24 3.14 3.10
Seasonal space heating eff. class A A+ A

Indoor Unit EHBH 11CB3V 11CB9W 16CB3V 16CB9W 16CB3V 16CB9W 11CB3V 11CB9W 16CB3V 16CB9W 16CB3V 16CB9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 890x480x344
Weight Unit kg 43 44 45 44 45 43 44 45 44 45
Operation range Heating Water side Min.~Max. °C 15~55
Domestic hot water Water side Min.~Max. °C 25~80
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 41 44 41 44
Sound pressure level Nom. dBA 27 30 27 30

Outdoor Unit ERHQ 011BV3 014BV3 016BV3 011BW1 014BW1 016BW1


Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320
Weight Unit kg 102 108
Compressor Quantity 1
Type Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~46.0
Domestic hot water Min.~Max. °CDB -20~35
Refrigerant Type R-410A
Charge kg 2.7 3.0
TCO₂eq 5.6 6.3
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 64 66 64 66
Cooling Nom. dBA 64 66 69 64 66 69
Sound pressure Heating Nom. dBA 49 51 53 51 52
level Cooling Nom. dBA 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 32 20

58
Specifications

EHBX-CB + ERLQ-CV3/ERLQ-CW1

04CB3V + 08CB3V/9W + 08CB3V/9W + 11CB3V/9W + 16CB3V /9W+ 16CB3V/9W + 11CB3V/9W + 16CB3V/9W +


Efficiency data EHBX + ERLQ 16CB3V/9W + 016CW1
004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1
Heating capacity Nom. kW 4.40 / 4.03 6.00 / 5.67 7.40 / 6.89 11.20 / 11.00 14.50 / 13.60 16.00 / 15.20 11.20 / 11.00 14.50 / 13.60 16.00 / 15.20
Cooling capacity Nom. kW 4.1 / 4.2 5.9 / 4.8 6.2 / 5.4 12.1 / 11.7 12.7 / 12.6 13.8 / 13.1 12.1 / 11.7 12.7 / 12.6 13.8 / 13.1
Power input Heating Nom. kW 0.87 / 1.13 1.27 / 1.59 1.66 / 2.01 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66 2.43 / 3.10 3.37 / 4.10 3.76 / 4.66
Cooling Nom. kW 0.90 / 1.80 1.51 / 2.07 1.64 / 2.34 3.05 / 4.31 3.21 / 5.08 3.74 / 5.73 3.05 / 4.31 3.21 / 5.08 3.74 / 5.73
COP 5.04 / 3.58 4.74 / 3.56 4.45 / 3.42 4.60 / 2.75 / 3.55 / 2.10 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09 4.60 / 2.75 / 3.55 / 2.10 4.30 / 2.65 / 3.32 / 2.08 4.25 / 2.64 / 3.26 / 2.09
EER 4.55 / 2.32 3.89 / 2.34 3.79 / 2.29 3.98 / 2.72 3.96 / 2.47 3.69 / 2.29 3.98 / 2.72 3.96 / 2.47 3.69 / 2.29
Domestic hot water General Declared load profile - L
heating Average climate ηwh (water heating efficiency) % -
Water heating energy efficiency class -
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 125 124 126 124 120 122 124 120 122
outlet 55°C SCOP 3.20 3.17 3.23 3.18 3.07 3.13 3.18 3.07 3.13
Seasonal space heating eff. class A++ A+ A++ A+
Average climate water General ηs (Seasonal space heating efficiency) % 178 168 171 155 150 155 150
outlet 35°C SCOP 4.52 4.27 4.34 3.95 3.83 3.84 3.95 3.83 3.84
Seasonal space heating eff. class A+++ A++

Indoor Unit EHBX 04CB3V 08CB3V/9W 08CB3V/9W 11CB3V/9W 16CB3V/9W 16CB3V/9W 11CB3V/9W 16CB3V/9W 16CB3V/9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 890x480x344
Weight Unit kg 42 44 45 44 45 43 45 44 46 44 46 43 45 44 46 44 46
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Cooling Water side Min.~Max. °C 5~22 5~22
Domestic hot water Water side Min.~Max. °C 25~80 25~80
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 40 41 44 41 44
Sound pressure level Nom. dBA 26 27 30 27 30

Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20

59
Specifications

EHBX-CB + ERHQ-BV3/ERHQ-BW1

11CB3V + 11CB9W + 16CB3V + 16CB9W + 16CB3V + 16CB9W + 11CB3V + 11CB9W + 16CB3V + 16CB9W + 16CB3V + 16CB9W +
Efficiency data EHBX + ERHQ
011BV3 011BV3 014BV3 014BV3 016BV3 016BV3 011BW1 011BW1 014BW1 014BW1 016BW1 016BW1
Heating capacity Nom. kW 11.20 (1 / 10.30 (2 14.00 (1 / 13.10 (2 16.00 (1 / 15.20 (2 11.32 (1 / 10.98 (2 14.50 (1 / 13.57 (2 16.05 (1 / 15.11 (2
Cooling capacity Nom. kW 13.9 (1 / 10.0 (2 17.3 (1 / 12.5 (2 17.8 (1 / 13.1 (2 15.1 (1 / 11.7 (2 16.1 (1 / 12.6 (2 16.8 (1 / 13.1 (2
Power input Heating Nom. kW 2.55 (1 / 3.17 (2 3.26 (1 / 4.04 (2 3.92 (1 / 4.75 (2 2.63 (1 / 3.24 (2 3.42 (1 / 4.21 (2 3.82 (1 / 4.69 (2
Cooling Nom. kW 3.86 (1 / 3.69 (2 5.86 (1 / 5.69 (2 6.87 (1 / 5.95 (2 4.53 (1 / 4.31 (2 5.43 (1 / 5.08 (2 6.16 (1 / 5.73 (2
COP 4.39 (1 / 3.25 (2 4.29 (1 / 3.24 (2 4.08 (1 / 3.20 (2 4.30 (1 / 3.39 (2 4.24 (1 / 3.22 (2 4.20 (1 / 3.22 (2
EER 3.60 (1 / 2.71 (2 2.95 (1 / 2.32 (2 2.59 (1 / 2.20 (2 3.32 (1 / 2.72 (2 2.96 (1 / 2.47 (2 2.72 (1 / 2.29 (2
Domestic hot water General Declared load profile -
heating Average climate ηwh (water heating efficiency) % -
Water heating energy efficiency class -
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118
outlet 55°C SCOP 2.93 2.91 2.94 3.00 2.98 3.03
Seasonal space heating eff. class A+
Average climate water General ηs (Seasonal space heating efficiency) % 118 130 127 130
outlet 35°C SCOP 3.02 3.32 3.25 3.24 3.14 3.10
Seasonal space heating eff. class A A+

Indoor Unit EHBX 11CB3V 11CB9W 16CB3V 16CB9W 16CB3V 16CB9W 11CB3V 11CB9W 16CB3V 16CB9W 16CB3V 16CB9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 890x480x344
Weight Unit kg 43 45 44 46 44 46 43 45 44 46 44 46
Operation range Heating Water side Min.~Max. °C 15~55
Cooling Water side Min.~Max. °C 5~22
Domestic hot water Water side Min.~Max. °C 25~80
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 41 44 41 44
Sound pressure level Nom. dBA 27 30 27 30

Outdoor Unit ERHQ 011BV3 014BV3 016BV3 011BW1 014BW1 016BW1


Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320
Weight Unit kg 102 108
Compressor Quantity 1
Type Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~46.0
Domestic hot water Min.~Max. °CDB -20 (2.000~35 (2
Refrigerant Type R-410A
Charge kg 2.7 3.0
TCO₂eq 5.6 6.3
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 64 (3 66 (3 64 (3 66 (3
Cooling Nom. dBA 64 (4 66 (4 69 (4 64 (4 66 (4 69 (4
Sound pressure level Heating Nom. dBA 49 (5 51 (5 53 (5 51 (5 52 (5
Cooling Nom. dBA 50 (6 52 (6 54 (6 50 (6 52 (6 54 (6
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 32 20

Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

60
Specifications

4. Monobloc outdoor unit

EDLQ-CV3/EBLQ-CV3

Single Unit EDLQ/EBLQ 05CV3 07CV3 05CV3 07CV3


Heating capacity Nom. kW 4.40 / 4.03 7.00 / 6.90 4.40 / 4.03 7.00 / 6.90
Cooling capacity Nom. kW - 3.9 / 4.2 5.2 / 5.4
Power input Cooling Nom. kW - 0.95 / 1.80 1.37 / 2.34
Heating Nom. kW 0.88 / 1.13 1.55 / 2.02 0.88 / 1.13 1.55 / 2.02
COP 5.00 / 3.58 4.52 / 3.42 5.00 / 3.58 4.52 / 3.42
EER - 4.07 / 2.32 3.80 / 2.29
Dimensions Unit Height mm 735
Width mm 1,085
Depth mm 350
Weight Unit kg 76 80 76 80
Operation range Heating Water side Min.~Max. °C 15~55
Cooling Ambient Min.~Max. °CDB -~- 10~43
Water side Min.~Max. °C -~- 5~22
Domestic hot Ambient Min.~Max. °CDB -25~35
water Water side Min.~Max. °C 25~80
Refrigerant Type R-410A
Charge kg 1.30 1.45 1.30 1.45
TCO₂eq 2.7 3.0 2.7 3.0
Control Expansion valve (electronic type)
GWP 2,087.5
Sound power Heating Nom. dBA 61 62 61 62
level Cooling Nom. dBA 63
Sound pressure Heating Nom. dBA 48 49 48 49
level Cooling Nom. dBA 48 50 48 50
Space heating Average climate General ηs (Seasonal space heating efficiency) % 125 126 125 126
water outlet SCOP 3.20 3.22 3.20 3.22
55°C Seasonal space heating eff. class A++
Average climate General ηs (Seasonal space heating efficiency) % 172 163 172 163
water outlet SCOP 4.39 4.14 4.39 4.14
35°C Seasonal space heating eff. class A++

EKCB-CV3/EK2CB-CV3

Single Unit EKCB 07CV3 EK2CB07CV3


Dimensions Unit Height mm 360
Width mm 340
Depth mm 97
Weight Unit kg 4
Operation range Heating Ambient Min.~Max. -
Indoor Ambient Min. °CDB 5
installation Max. °CDB 35
Refrigerant Charge TCO₂eq -
Control -
GWP -

EKMBUHC3V3/EKMBUHC9W1

Single Unit EKMBUHC3V3 EKMBUHC9W1


Dimensions Unit Height mm 560
Width mm 250
Depth mm 210
Weight Unit kg 11 13
Operation range Heating Ambient Min.~Max. -
Indoor Ambient Min. °CDB 5
installation Max. °CDB 30
Refrigerant Charge TCO₂eq -
Control -
GWP -

61
Specifications

5. Domestic hot water tanks

EKHWP-B

Accessory EKHWP 300B 500B


Casing Colour Traffic white (RAL9016) / Dark grey (RAL7011)
Material Impact resistant polypropylene
Dimensions Unit Width mm 595 790
Depth mm 615 790
Weight Unit Empty kg 58 82
Tank Water volume l 300 500
Material Polypropylen
Maximum water temperature °C 85
Insulation Heat loss kWh/24h 1.5 1.7
Energy efficiency class B
Standing heat loss W 64 72
Storage volume l 294 477
Heat exchanger Domestic hot Quantity 1
water Tube material Stainless steel (DIN 1.4404)
Face area m² 5.600 5.800
Internal coil volume l 27.1 29.0
Operating pressure bar 6
Average specifc thermal output W/K 2,790 2,825
Charging Quantity 1
Tube material Stainless steel (DIN 1.4404)
Face area m² 3 4
Internal coil volume l 13 19
Operating pressure bar 3
Average specifc thermal output W/K 1,300 1,800
Auxiliary solar Tube material - Stainless steel (DIN 1.4404)
heating Face area m² - 1
Internal coil volume l - 2
Operating pressure bar - 3
Average specifc thermal output W/K - 280

EKHWP-PB

Accessory EKHWP 300PB 500PB


Casing Colour Traffic white (RAL9016) / Dark grey (RAL7011)
Material Impact resistant polypropylene
Dimensions Unit Width mm - 790
Depth mm 615 790
Weight Unit Empty kg 64 92
Tank Water volume l 294 477
Material Polypropylen
Maximum water temperature °C 85
Insulation Heat loss kWh/24h 1.5 1.7
Energy efficiency class B
Standing heat loss W 64 72
Storage volume l 294 477
Heat exchanger Domestic hot Quantity 1
water Tube material Stainless steel (DIN 1.4404)
Face area m² 5.600 5.800
Internal coil volume l 27.1 29.0
Operating pressure bar 6
Average specifc thermal output W/K 2,790 2,825
Charging Quantity 1
Tube material Stainless steel (DIN 1.4404)
Face area m² 3 4
Internal coil volume l 13 19
Operating pressure bar 3
Average specifc thermal output W/K 1,300 1,800
Auxiliary solar Tube material - Stainless steel (DIN 1.4404)
heating Face area m² - 1
Internal coil volume l - 2
Operating pressure bar - 3
Average specifc thermal output W/K - 280

*Note: blue cells contain preliminary data

62
Specifications

EKHWS-B3V3/EKHWS-B3Z2

Accessory EKHWS 150B3V3 200B3V3 300B3V3 200B3Z2 300B3Z2


Casing Colour Neutral white
Material Epoxy-coated mild steel
Dimensions Unit Width mm 580
Depth mm 580
Weight Unit Empty kg 37 45 59 45 59
Tank Water volume l 150 200 285 200 285
Material Stainless steel (DIN 1.4521)
Maximum water temperature °C 85
Insulation Heat loss kWh/24h 155.0 177.0 219.0 177.0 219.0
Energy efficiency class C
Standing heat loss W 65 74 91 74 91
Storage volume l 150 200 285 200 285
Heat exchanger Quantity 1
Tube material Duplex steel LDX 2101
Booster heater Capacity kW 3
Power supply Phase/Frequency/Voltage Hz/V 1~/50/230 2~/50/400

EKHWE-A3V3/EKHWE-A3Z2

Accessory EKHWE 150A3V3 200A3V3 300A3V3 200A3Z2 300A3Z2


Casing Colour RAL9010
Material Epoxy coated steel
Dimensions Unit Diameter mm 545 660 545 660
Weight Unit Empty kg 80 104 140 104 140
Tank Water volume l 150 200 300 200 300
Material Enamel coated steel acc. DIN4753TL2
Maximum water temperature °C 75
Insulation Heat loss kWh/24h 1.7 1.9 2.5 1.9 2.5
Energy efficiency class C D C D
Standing heat loss W 71 79 104 79 104
Storage volume l 150 200 300 200 300
Heat exchanger Quantity 1
Booster heater Capacity kW 3
Power supply Phase/Frequency/Voltage Hz/V 1~/50/230 2~/50/400

63
Specifications

6. Solar system

EKSH-P/EKSV-P

Accessory EKSV/EKSH EKSH26P EKSV21P EKSV26P


Mounting Horizontal Vertical
Dimensions Unit HeightxWidthxDepth mm 2,000x85x1,300 1,006x85x2,000 1,300x85x2,000
Weight Unit kg 42 33 42
Volume l 21 1.3 1.7
Surface Outer m² 2.6 2.01 2.60
Aperture m² 2.360 1.800 2.360
Absorber m² 2.35 1.79 2.35
Coating Micro-therm (absorption max. 96%, Emission ca. 5% +/-2%)
Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate
Glazing Single pane safety glass, transmission +/- 92%
Allowed roof angle Min.~Max. ° 15~80
Operating pressure Max. bar 6
Stand still temperature Max. °C 192
Thermal Zero loss collector efficiency η0 % -
performance Heat loss coefficient a1 W/m².K 4.250 4.240 4.250
Temperature dependence of the heat loss coefficient a2 W/m².K² 0.007 0.006 0.007
Thermal capacity kJ/K 6.5 4.9 6.5

EKSRPS

Accessory EKSRPS 4
Mounting On side of tank
Dimensions Unit HeightxWidthxDepth mm 815x142x230
Weight Unit kg 6
Operation range Ambient temperature Min.~Max. °C 5~40
Operating pressure Max. bar 0
Stand still temperature Max. °C 85
Thermal collector efficiency (ηcol) % -
performance Zero loss collector efficiency η0 % -
Control Type Digital temperature difference controller with plain text display
Power consumption W 2
Power supply Phase/Frequency/Voltage Hz/V 1~/50/230
Power supply intake Indoor unit

EKSRDS2

Accessory EKSRDS2
Mounting On wall
Dimensions Unit HeightxWidthxDepth mm 410x314x154
Thermal performance Zero loss collector efficiency η0 % -
Control Type Digital temperature difference controller with plain text display
Power supply Frequency/Voltage V 50/230

64
Specifications

7. Controls

EKRUCBL/EKRUCBS

Indoor unit EKRUCBL1-7 EKRUCBS


Control systems Class of temperature control VI
Contribution to seasonal space heating efficiency % 4.0

EKRTW/EKRTR

Accessory EKRTR1 EKRTWA


Dimensions Unit HeightxWidthxDepth mm 87x125x34
Receiver Height/Width/Depth mm 170/50/28 -
Weight Unit g - 215
Thermostat g 210 -
Receiver g 125 -
Ambient Storage Min./Max. °C -20/60
temperature Operation Min./Max. °C 0/50
Temperature Heating Min./Max. °C 4/37
setting range Cooling Min./Max. °C 4/37
Clock Yes
Regulation function Proportional band
Power supply Voltage V - Battery powered 3* AA-LR6 (alkaline)
Thermostat Voltage V Battery powered 3x AA-LRG (alkaline) -
Receiver Voltage V 230 -
Frequency Hz 50 -
Phase 1~ -
Connection Type - Wired
Thermostat Wireless -
Receiver Wired -
Maximum distance Indoor m approx. 30m -
to receiver Outdoor m approx. 100m -
Control systems Class of temperature control IV
Contribution to seasonal space heating efficiency % 2.0

65
Trust Daikin
Daikin may not be a household name. After all, we don’t make cars, TVs, fridges or washing machines. But we do make world-class heat pumps.
In fact, more than 275,000 Daikin Altherma heat pumps have been fitted across Europe since its initial launch in 2006.Because we focus on doing
only what we’re best at: creating the most efficient heating, ventilation and air conditioning solutions, renowned for design excellence, quality
and reliability. So you can depend on Daikin for the ultimate in comfort, leaving you free to focus on other essentials.

Daikin Europe N.V.  Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)

Daikin Europe N.V. participates in the Eurovent Certification


programme for Liquid Chilling Packages (LCP), Air handling
units (AHU) and Fan coil units (FCU), Check ongoing validity
of certificate online: www.eurovent-certification.com or using:
www.certiflash.com
The present publication is drawn up by way of information only and does not constitute an offer binding upon
ECPEN15 - 724 XXX · 07/15 Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge.
No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose
of its content and the products and services presented therein. Specifications are subject to change without prior
notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense,
arising from or related to the use and/or interpretation of this publication. All content is copyrighted by
Daikin Europe N.V.

The present publication supersedes ECPEN14-721. Printed on non-chlorinated paper.


Prepared by La Movida, Belgium.