Professional Documents
Culture Documents
Daikin Altherma
low temperature
heat pump
Air to water heat pumps with the highest efficiency for new build
Why choose Daikin?
So can you meet all your objectives. As an industry leader, Daikin supports you with
a combination of broad experience, technical innovation and responsive customer service.
Reliability
Control
Reliability is a prerequisite for any new heating
Our specially developed and proven control system system – for installers and end users.
with its new user interface makes the Daikin Daikin technology, designed and manufactured to
Altherma heat pump intuitive and easy to control. the highest standards, has proved to be the ultimate
This means easy commissioning for you, while users in reliability. Based on years of development and
can be totally in charge of their comfort and costs. experience, and manufactured to exact tolerances,
our technology will give years of trouble-free
operation.
2
Daikin quality
Daikin has a worldwide reputation based on 90 years of experience in
the successful manufacturer of high-quality air conditioning equipment
for residential, commercial and industrial use. It has been a leader in heat pump
technology for 56 years. Daikin’s much envied quality quite simply stems from
the close attention we pay to design, production and testing, as well as aftersales
support. To this end, every component is carefully selected and rigorously tested
to verify its contribution to product quality and reliability.
This ensures that every Daikin installation is a successful one for you.
Seasonal efficiency,
smart use of energy The seasonal efficiency (also called SCOP) of a heat
pump is the average efficiency over a whole year.
The total heating output per year is defined by
The EU wants to inform people about the climatic conditions and house specifications
the amount of energy that products consume, (heat load, required water temperatures, etc.), and is
and will ban inefficient products from the independent of the type of heating system.
The total electricity input per year is the critical
market. Seasonally-efficient units are optimised parameter, as this is what the customer pays for.
to be energy efficient for the average conditions This means the SCOP value can be seen as the real
users can expect over an entire heating and operating efficiency of a heat pump system.
cooling season.
3
Why choose
80%
ambient air
100%
energy
25%
electricity
4
The complete solution
Solar collector Convector Hot water
With the integrated solar unit or in Heating and cooling Hot water is always available
option with the wall mounted unit with convector integration. with Daikin’s air-to-water heat pump
system, along with outstanding
energy savings.
Outdoor unit
5
An innovative product 1. Floor-standing unit with integrated
Solutions
offered in Different
technologies
4 solutions
Specifications p 22
Different
heating
Perfect fit for new builds applications
Specifications p 47
Different
heat emitters
6
2. Integrated solar unit and
3. Wall mounted unit 4. Monobloc outdoor unit
domestic hot water tank
p 28 p32 p 38
›› Space heating
›› Domestic hot water
›› Cooling
›› Solar connection for hot water production
›› 1 indoor unit
›› 1 outdoor unit
›› 1 outdoor unit
7
Best seasonal efficiencies,
providing
the highest
savings
on running
costs
With many years of air-to-water
heat pump experience and over
175,000 units installed throughout
Europe, we continuously strive
to optimise Daikin Altherma’s
performance. We do this by
maximising energy output and
limiting electrical inputs.
As an installer, this means you are ready
to meet the growing demand for more
energy efficient systems.
8
Integrated floor standing unit
9
Best seasonal efficiencies
10
Best seasonal efficiencies
Daikin Altherma low temperature maintains its ›› Optimised controls to achieve higher frequency of
high heating capacities even in the lowest outdoor use at low outdoor temperatures
temperatures. Electrical back-up heater assistance ›› Liquid injection to avoid too-high discharge
is required never or rarely. These high heating temperatures when high water temperatures are
capacities, available across the whole required at low outdoor temperatures
Daikin Altherma low temperature 4kW-16kW ›› Perfectly-dimensioned plate heat exchangers to
range, are achieved thanks to the combination of maximise the heat exchange surface
technologies:
10
›› + 40% capacity at -15°C
8
›› No need for back up heater from -10°C
6
onwards (compared to -5°C for standard
Less BUH
heat pump) 4
required
2
11
Best seasonal efficiencies
The partial load operation and optimal operation area can be illustrated
by a typical application in Paris
Typical application: Efficient partial-load operation is especially ›› Largest part of heat output
important for the temperature range where delivered at optimal efficiencies
›› Location: Paris the highest heat output is required. Typically, 80% ›› Less on/off operation when heat
›› Design temperature: -7°C of the total heat output is required in an outdoor load becomes lower than the
›› Heat load: 7kW temperature range of -2°C to 10°C. Achieving high minimum capacity the heat pump
›› Heating off temperature: 16°C efficiencies in this temperature range contributes can deliver, optimising efficiency
strongly to high seasonal efficiencies. and comfort
1600 1000
800
1200 High efficiency crucial in
Ta range -2C° to 10°C
600
Heat load 7kW
800
400
400
200
Operation hours
kWh heat output
Ta switch off 0 0
-10 -2 0 10 20 30
Outdoor temperature (°C)
12
Best seasonal efficiencies
In addition to limiting the electrical input of ›› No bottom plate heater needed on 4-8kW class
the compressor and the electrical back-up heater, ›› Low-capacity bottom plate heater on 11-16kW class
Daikin pays special attention to limiting electrical (ERLQ-C series), only operating during defrost
inputs of auxiliary components. This also contributes cycles, results in 90% less electricity consumption
to the high seasonal efficiencies achieved by when compared with standard thermostatic
the Daikin Altherma range. controlled bottom plate heaters.
13
Perfect fit
14
Best seasonal efficiencies
Hot water
Hot water is always
available with Daikin’s air to water heat
pump system along with outstanding
energy savings.
Solar collector
(With integrated solar unit or in option
with the wall mounted unit)
Convector
Cooling and heating with
convector integration
15
Perfect fit for new builds, as well as for low-energy houses
Daikin Altherma low capacity unit is developed and Example of individual product label:
dimensioned to reach optimal efficiencies at monobloc outdoor unit - space heating
the most relevant temperature range, thanks to its
high modulating range.
16
Perfect fit for new builds, as well as for low-energy houses
800 1000
900
700
800
600 High efficiency crucial in
Ta range -3C° to 7°C 700
500 Heat load 4kW 600
400 500
400
300
300
200
200
100
Operation hours 100
kWh heat output
Ta switch off 0 0
-10 -5 0 5 10 15 20 25 30
Outdoor temperature (°C)
1 1
Resulting in
0 0
the best possible
-8 -6 -4 -2 0 2 4 6 8 10 12 14 -8 -6 -4 -2 0 2 4 6 8 10 12 14 effficiencies
Outdoor temperature (°C) Outdoor temperature (°C)
17
b. Maximum comfort
Keeping the house at the desired The combined effect of the Daikin inverter
temperature the whole year, with both heating and compressors and weather-dependent set-point
cooling possible control guarantees a continuous heating operation.
›› Only one outdoor unit required to provide heating With higher outdoor temperature, the water
and cooling temperature will be lowered and the frequency of
›› Same emitters can be used for heating and the compressor reduced, in order to ensure
cooling (Daikin heat pump convector or under- a continuous heating operation, providing stable
floor system) room temperature.
18
Perfect fit for new builds, as well as for low-energy houses
45°C
Balancing
vessel Low-temperature radiator
45°C
Mixing valve 35°C
Under-floor
heating
19
Perfect fit for new builds, as well as for low-energy houses
4-8 kW: High pressure switch Four way valve Outdoor unit fan &
hermetically sealed The HP switch in the discharge line Used to switch the HP from fan motor
swing compressor protects the unit against too high heating (ON) to cooling mode (OFF) Helps control
pressure Reversed cycle for defrost the differential pressure
between high- and
low-pressure side.
Operates according to
ambient temperature
and condensation
temperature.
20
Perfect fit for new builds, as well as for low-energy houses
Bottom plate
21
1.
Floor-standing unit with integrated
domestic hot water tank
saving installation
space and time
22
Best seasonal efficiencies
23
Integrated floor standing unit
›› The stainless steel domestic hot water tank is ›› The electric PCB board and hydraulic components
included in the unit, with all connections between are accessible from the front. This makes servicing
the heat pump module and tank factory-mounted. easy and avoids the risk of damage to electrical
This permits a fast installation compared to components due to water leakage.
a traditional set-up (wall-mounted with separate ›› All water and refrigerant connections are at
domestic hot water tank) – saving you time. the top of the unit, for easy connection and
You only need to connect the water and accessibility. And with no connections at
refrigerant pipes. the back of the unit, the installation footprint is
›› All hydraulic components are included (circulating even smaller.
pump, expansion vessel, back-up heater, etc.).
No need to look for third-party components.
Connections
from the top
Expansion vessel
Components
are accessible from
the front
water pump
Domestic hot
water tank
PCB board
24
Integrated floor standing unit
Thanks to the all-in-one design, Compared to the traditional split-up version for
the installation space is minimised both in
1 a wall-mounted indoor unit and separate domestic
terms of footprint and height hot water tank, the integrated indoor unit greatly
reduces the installation space required.
Hydrobox
DHW tank
Space
reduced
VS
1732 mm
by more
than
30%
580 mm X 370 mm
72
8m
950 mm + X m
m
600 m
25
Integrated floor standing unit
The domestic hot water tank of the integrated indoor Daikin Altherma uses smart controls to heat
unit is equipped with thick polystyrene insulation, the domestic hot water tank, maximising efficiency
resulting in 50% less heat loss compared to a standard and comfort for the end-user. The combination of
insulated tank. This means high savings on running the schedule and reheat functions guarantees
costs, as less energy is required for the next heat-up minimum electrical input and ensures constant
cycle. availability of hot water.
Heat loss from the 180l tank: only 1.4kWh per 24h ›› Schedule function: heat the tank to a pre-set
(temperature difference of 45°C between tank and room temperature at a specified time. Can be repeated
temperature). four times per day, with the possibility of setting
two different tank temperatures (storage comfort
Maximum efficiency and storage economic).
›› Reheat function: when the tank temperature
Daikin Altherma low temperature can heat goes below a specified minimum reheat
the domestic hot water tank to high temperatures with temperature, Daikin Altherma switches
heat pump operation only, minimising the need for automatically to domestic hot water heating,
electrical assistance, and maximising efficiency. heating the tank to
a specified maximum reheat temperature.
Tank temperature up to 55°C with heat pump only,
up to 60°C with the standard back-up heater of ›› Both functions can be used individually or in
the heat pump module. combination to provide the best efficiency and
maximum comfort. The schedule function can
High hot water volumes heat the tank during the night, with the low
electricity tariff, up to a relatively low temperature
The following volumes can be achieved with only one (e.g. 50°C without electrical assistance).
heat-up cycle. When higher hot water consumption occurs
during the day (lowering the tank temperature to
›› Hot water volume of 300l available at 40°C the minimum reheat temperature) the heat pump
(sufficient for six showers) without electrical will switch automatically to domestic hot water
assistance (260l tank, tank temperature 50°C, heating with the reheat function to guarantee
cold water temperature 10°C, one heat-up cycle). the constant availability of hot water. Thanks to
›› Hot water volume can be increased to 375l using the large coil surface of the tank (1.56m2) heating
the standard back-up heater (260l tank, tank the tank with the schedule or reheat functions
temperature up to 60°C). occurs very quickly.
26
Integrated floor standing unit
27
2.
Integrated solar unit and domestic
hot water tank
maximising
renewable energy
and offering top
comfort for hot
water preparation
28
Best seasonal efficiencies
29
Integrated solar unit
Thanks to the extremely high efficiency of our flat Combined with a heat pump, which also exploits
solar collector up to 80% of solar energy can be regenerative ambient energy, the use of ancillary
converted into usable heat. In this application solar energy is reduced to an absolute minimum – saving
energy and heat pumps complement each other costs for your customer.
ideally: the heat pump adds the required amount of
heat to the system to meet the demand.
kWh
3.000
2.500
2.000
1.500
1.000
500
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Offer a drain-back or pressurised system gradient is not possible, then a pressurised solar
depending on your customers‘ needs. system is a better solution.
Drain-back solar system (with EHSH(X)-A) Pressurised solar system (with EHSH(X)B-A)
If the constructional conditions permit, recommend The pressurised solar system is easy to install and
the direct drain-back system. In this system, the suitable for any application, in any building. It
water in the storage tank is supplied directly and operates efficiently and safely at all pipe lengths
without heat exchanger to the solar collectors, and feed heights. The structure of the solar thermal
heated and then stored. This process considerably storage tank is engineered so that an additional plate
increases the efficiency of the entire system, heat exchanger is not necessary. A bivalent heat
especially the solar collectors. Because the system exchanger for pressurised solar or other heat sources
is not pressurised, there is no need for an expansion is already incorporated, making the system simple
tank, pressure relief valve, pressure gauge or heat and flexible.
exchanger.
30
Integrated solar unit
offering flexibility
for installation and
domestic hot water
connection
32
For some of your customers
the alternative set-up of
the wall-mounted indoor
unit will be the perfect
solution. The indoor unit
– including all hydraulic
components – can be
combined with a separate
domestic hot water tank.
33
Wall mounted unit
Heat exchanger
Expansion vessel
a. Flexible solutions
2. W
hen combined with a separate domestic
hot water tank is needed.
34
Wall mounted unit
35
Wall mounted unit
At the first start-up, a quick configuration wizard ›› Before the actual test-run of the unit, an actuator
will guide you smoothly through the commissioning test mode allows all the wired components to
process. Through a series of short questions, be activated one by one. This permits a quick and
the set-up of basic parameters will automatically be easy check of all connections and wiring to ensure
completed. You can fine-tune these parameters using correct operation.
the menu-based navigation. The quick configuration ›› You can activate an automatic screed-drying
wizard ensures that only the parameter settings function to proceed through a gradual heat-up of
relevant to the installation will be shown in the menus. an under-floor heating system to avoid cracks in
The irrelevant parameters remain hidden and thus the floor during first use.
inaccessible. ›› Individual and easy-to-programme schedule
timers – for heating, cooling, domestic hot
You can download the parameters to a PC as water operation and recirculation, noise-sensitive
a back-up, or for duplication on similar installations. operation and electrical booster heating – will
If preferred, you can prepare the parameter settings adjust operation to match the end-user’s typical
beforehand and upload them to the unit during daily schedule.
commissioning. ›› After the commissioning, access to the installer’s
menu can be restricted (manually or automatically
after one hour) to avoid wrong manipulation of
the unit by the end-user.
36
Wall mounted unit
c. Easy serviceability
Navigational buttons
37
4.
Monobloc outdoor unit,
designed for
low temperature
applications
38
Daikin Altherma
low temperature monobloc has
been designed with installers
in mind. The result is our most
compact monobloc ever,
all-in-one air-water heat pump
– small, light and easy to handle.
39
Daikin Altherma low temperature monobloc
a. A natural fit
735 mm
components
›› Smallest installed volume in the market:
H735 x W1085 x D360 mm – only 80 kg
›› The separate installation of controller and wiring
centre allows a flexible installation in the house.
user interface
Wiring centre Domestic hot water
Hot water
Outdoor tank
unit
3 way valve
40
Daikin Altherma low temperature monobloc
Radiators
Outdoor unit
41
Daikin Altherma low temperature monobloc
42
Daikin Altherma low temperature monobloc
Low voltage
43
Servicing
a. Troubleshooting
1. A smart system controller facilitates
diagnostics and serviceability
44
Servicing
b. Repair
1. To facilitate repairs, units are carefully
designed for easy accessibility
Geen HR beeld
gekregen
c. Maintenance
1. State-of-the-art design and exceptional 2. Annual maintenance tasks to keep
build quality ensure that maintenance the system running smoothly
procedures are kept to the minimum
›› To ensure that your customer’s Altherma low
›› The state-of-the-art design and exceptional temperature system operates smoothly and at the
build quality of our indoor and outdoor systems highest possible efficiency levels, here is
ensure that maintenance procedures are kept a list of the key maintenance items that should be
to a minimum – and can be done quickly and checked on an annual basis.
efficiently. The easy-access design will certainly ›› Fluid pressure of space heating circuit
make your job easier. ›› Relief valve hose
›› Pressure relief valve of space heating circuit
›› Pressure relief valve of domestic hot water tank
›› Filters
›› Draining of the domestic hot water tank
›› Anode
›› Descaling and chemical disinfection
›› Switch box
›› Domestic hot water tank booster heater
(in case non-integrated tank)
45
Heat pump
in practice
a. Example of running cost and CO2 comparison
Daikin provides a web-based tool you and your floor area, number of people), a comparison is made
customer can use to get a quick estimation of savings between the Daikin Altherma heat pump system and
on both running costs and CO2 emissions. Based on a traditional heating systems, including space heating
few inputs from your customer (location, house type, and domestic hot water heating. This is available for
both new builds and refurbishment applications.
Energy savings calculator
* Simulation for a new build
detached house (room in roof )
Go to ecocalc.daikin.eu and see how a Daikin Altherma with low temperature emitters,
heat pump saves on both running costs and CO2 for 4 people and a heated surface
emission. of 125m2, taking into account
Belgian climate conditions, an
electricity price of 0.17EUR/kWh
and a gas price of 0.06 EUR/kWh.
b. Simulation software
The Daikin Altherma simulation software can provides detailed information for you and your
evaluate every specific application and appropriate customer, about the expected outcome of
heat pump selection, taking into account the needs of the specified Daikin Altherma unit, for its specific
the building and specific climate data. You simply application and climate:
provide the following data, and the software does
the rest! ›› Seasonal efficiency of the heat pump system
›› Amount of back-up heater operation
›› House application: heat/cool load, ›› Energy consumption and energy cost per month
water temperatures, power supply ›› Savings on running costs compared to traditional
›› Climate conditions: location, design temperature heating systems
›› Domestic hot water requirements: tank volume,
material, solar connection All this information in summarised in a detailed report.
›› Preferences: “heating off“ temperature, night
setback function
specifications
1. Floor standing unit
EHVH-CB + ERLQ-CV3/CW1
11S18CB3V 11S18CB3V /
Indoor Unit EHVH 04S18CB3V 08S18CB3V /08S26CB9W 16S18CB3V /16S26CB9W 16S18CB3V / 16S26CB9W
11S26CB9W 11S26CB9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728
Weight Unit kg 116 117 127 117 127 117 126 118 128 118 128 117 126 118 128 118 128
Tank Water volume l 180 260 180 260 180 260 180 260 180 260 180 260 180 260 180 260
Maximum water temperature °C 65
Maximum water pressure bar 10
Corrosion protection Anode
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Domestic hot water Water side Min.~Max. °C 25~60 25~60 / 60
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 42 44 42 44
Sound pressure level Nom. dBA 28 30 28 30
Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20
47
Specifications
EHVH-CB + ERHQ-BV3/ERHQ-BW1
11S26CB9W 11S18CB3V 16S26CB9W + 16S18CB3V 16S26CB9W + 16S18CB3V 11S26CB9W 11S18CB3V 16S26CB9W + 16S18CB3V 16S26CB9W 16S18CB3V
Efficiency data EHVH + ERHQ
+ 011BV3 + 011BV3 014BV3 + 014BV3 016BV3 + 016BV3 + 011BW1 + 011BW1 014BW1 + 014BW1 + 014BV3 + 014BV3
Heating capacity Nom. kW 11.20 / 10.30 14.00 / 13.10 16.00 / 15.20 11.32 / 10.98 14.50 / 13.57 16.05 / 15.11
Power input Heating Nom. kW 2.55 / 3.17 3.26 / 4.04 3.92 / 4.75 2.63 / 3.24 3.42 / 4.21 3.82 / 4.69
COP 4.39 / 3.25 4.29 / 3.24 4.08 / 3.20 4.30 / 3.39 4.24 / 3.22 4.20 / 3.22
Domestic hot water General Declared load profile XL L XL L XL L XL L XL L XL L
heating Average climate ηwh (water heating efficiency) % 95 91 95 91 95 91 87 84 87 84 87 84
Water heating energy efficiency class A
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118
outlet 55°C SCOP 2.93 2.91 2.94 3.00 2.98 3.03
Seasonal space heating eff. class A+
Average climate water General ηs (Seasonal space heating efficiency) % -
outlet 35°C SCOP 3.02 3.32 3.25 3.24 3.14 3.10
Seasonal space heating eff. class -
Indoor Unit EHVH 11S26CB9W 11S18CB3V 16S26CB9W 16S18CB3V 16S26CB9W 16S18CB3V 11S26CB9W 11S18CB3V 16S26CB9W 16S18CB3V 16S26CB9W 16S18CB3V
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728
Weight Unit kg 126 117 127 118 127 118 126 117 127 118 127 118
Tank Water volume l 260 180 260 180 260 180 260 180 260 180 260 180
Maximum water temperature °C 65
Maximum water pressure bar 10
Corrosion protection Anode
Operation range Heating Water side Min.~Max. °C 15~55
Domestic hot water Water side Min.~Max. °C 25~60 / 60
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 42 44 42 44
Sound pressure level Nom. dBA 28 30 28 30
48
Specifications
EHVX-CB + ERLQ-CV3/ERLQ-CW1
11S18CB3V / 11S18CB3V /
Indoor Unit EHVX 04S18CB3V 08S18CB3V / 08S26CB9W 16S18CB3V / 16S26CB9W 16S18CB3V / 16S26CB9W
11S26CB9W 11S26CB9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728
Weight Unit kg 117 119 129 119 129 119 128 120 130 120 130 119 128 120 130 120 130
Tank Water volume l 180 260 180 260 180 260 180 260 180 260 180 260 180 260 180 260
Maximum water temperature °C 65
Maximum water pressure bar 10
Corrosion protection Anode
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Cooling Water side Min.~Max. °C 5~22
Domestic hot water Water side Min.~Max. °C 25~60 25~60 / 60
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 42 44 42 44
Sound pressure level Nom. dBA 28 30 28 30
Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20
49
Specifications
EHVX-CB + ERHQ-BV3/ERHQ-BW1
11S18CB3V 11S26CB9W 16S18CB3V 16S26CB9W + 16S18CB3V 16S26CB9W + 11S18CB3V 11S26CB9W 16S18CB3V 16S26CB9W + 16S18CB3V 16S26CB9W
Efficiency data EHVX + ERHQ
+ 011BV3 + 011BV3 + 014BV3 014BV3 + 016BV3 016BV3 + 011BW1 + 011BW1 + 014BW1 014BW1 + 016BW1 + 016BW1
Heating capacity Nom. kW 11.20 / 10.30 14.00 / 13.10 16.00 / 15.20 11.32 / 10.98 14.50 / 13.57 16.05 / 15.11
Cooling capacity Nom. kW 13.9 / 10.0 17.3 / 12.5 17.8 / 13.1 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1
Power input Heating Nom. kW 2.55 / 3.17 3.26 / 4.04 3.92 / 4.75 2.63 / 3.24 3.42 / 4.21 3.82 / 4.69
Cooling Nom. kW 3.86 / 3.69 5.86 / 5.69 6.87 / 5.95 4.53 / 4.31 5.43 / 5.08 6.16 / 5.73
COP 4.39 / 3.25 4.29 / 3.24 4.08 / 3.20 4.30 / 3.39 4.24 / 3.22 4.20 / 3.22
EER 3.60 / 2.71 2.95 / 2.32 2.59 / 2.20 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29
Domestic hot water General Declared load profile L XL L XL L XL L XL L XL L XL
heating Average climate ηwh (water heating efficiency) % 91 95 91 95 91 95 84 87 84 87 84 87
Water heating energy efficiency class A
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118
outlet 55°C SCOP 2.93 2.91 2.94 3.00 2.98 3.03
Seasonal space heating eff. class A+
Average climate water General ηs (Seasonal space heating efficiency) % -
outlet 35°C SCOP 3.02 3.32 3.25 3.24 3.14 3.10
Seasonal space heating eff. class -
Indoor Unit EHVX 11S18CB3V 11S26CB9W 16S18CB3V 16S26CB9W 16S18CB3V 16S26CB9W 11S18CB3V 11S26CB9W 16S18CB3V 16S26CB9W 16S18CB3V 16S26CB9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728
Weight Unit kg 119 128 120 129 120 129 119 128 120 129 120 129
Tank Water volume l 180 260 180 260 180 260 180 260 180 260 180 260
Maximum water temperature °C 65
Maximum water pressure bar 10
Corrosion protection Anode
Operation range Heating Water side Min.~Max. °C 15~55
Cooling Water side Min.~Max. °C 5~22
Domestic hot water Water side Min.~Max. °C 25~60 / 60
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 42 44 42 44
Sound pressure level Nom. dBA 28 30 28 30
50
Specifications
EHVZ-CB3V + ERLQ-CV3/ERLQ-CW1
Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20
51
Specifications
EHVZ-CB3V + ERHQ-BV3/BW1
52
Specifications
EHSH-A + ERLQ-CV3/ERLQ-CW1
04P30A + 08P50A + 08P30A + 08P30A + 08P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A +
Efficiency data EHSH + ERLQ
004CV3 006CV3 006CV3 008CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Heating capacity Nom. kW 4.53 / 3.98 / 4.26 / 3.47 6.06 / 5.78 / 5.14 / 4.60 7.78 / 7.27 / 5.53 / 5.51 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05
Power input Heating Nom. kW 0.87 / 1.04 / 1.49 / 0.85 1.30 / 1.58 / 1.88 / 1.26 1.69 / 2.04 / 1.98 / 1.56 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93
COP 5.23 / 3.84 / 2.85 / 4.07 4.65 / 3.66 / 2.73 / 3.64 4.60 / 3.57 / 2.78 / 3.54 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15
Domestic hot water General Declared load profile L XL L XL
heating Average climate ηwh (water heating efficiency) % 103 102 98 90 96 83
Water heating energy efficiency class A
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 130 125 127 125 126 125 126 125
outlet 55°C Seasonal space heating eff. class A++
Average climate water General ηs (Seasonal space heating efficiency) % -
outlet 35°C Seasonal space heating eff. class -
Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20
53
Specifications
EHSHB-A + ERLQ-CV3/ERLQ-CW1
04P30A + 08P30A + 08P50A + 08P30A + 08P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A +
Efficiency data EHSHB + ERLQ
004CV3 006CV3 006CV3 008CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Heating capacity Nom. kW 4.53 / 3.98 / 4.26 / 3.47 6.06 / 5.78 / 5.14 / 4.60 7.78 / 7.27 / 5.53 / 5.51 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05
Power input Heating Nom. kW 0.87 / 1.04 / 1.49 / 0.85 1.30 / 1.58 / 1.88 / 1.26 1.69 / 2.04 / 1.98 / 1.56 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93
COP 5.23 / 3.84 / 2.85 / 4.07 4.65 / 3.66 / 2.73 / 3.64 4.60 / 3.57 / 2.78 / 3.54 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15
Domestic hot water General Declared load profile L XL L XL - XL -
heating Average climate ηwh (water heating efficiency) % 103 98 108 90 99 - 84 - -
Water heating energy efficiency class A - A - -
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 130 125 127 - 124 - -
outlet 55°C Seasonal space heating eff. class A++ - A+ - -
Average climate water General ηs (Seasonal space heating efficiency) % - -
outlet 35°C Seasonal space heating eff. class - -
Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20
54
Specifications
EHSX-A + ERLQ-CV3/ERLQ-CW1
04P30A + 08P30A + 08P50A + 08P30A + 08P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A +
Efficiency data EHSX + ERLQ
004CV3 006CV3 006CV3 008CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Heating capacity Nom. kW 4.53 / 3.98 / 4.26 / 3.47 6.06 / 5.78 / 5.14 / 4.60 7.78 / 7.27 / 5.53 / 5.51 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05
Cooling capacity Nom. kW 4.4 / 4.0 5.2 / 4.6 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1
Power input Heating Nom. kW 0.87 / 1.04 / 1.49 / 0.85 1.30 / 1.58 / 1.88 / 1.26 1.69 / 2.04 / 1.98 / 1.56 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93
Cooling Nom. kW 1.05 / 1.41 1.43 / 1.85 4.55 / 4.30 5.44 / 5.10 6.18 / 5.72 4.55 / 4.30 5.44 / 5.10 6.18 / 5.72
COP 5.23 / 3.84 / 2.85 / 4.07 4.65 / 3.66 / 2.73 / 3.64 4.60 / 3.57 / 2.78 / 3.54 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15
EER 4.21 / 2.85 3.65 / 2.51 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29
Domestic hot water General Declared load profile L XL L XL - XL -
heating Average climate ηwh (water heating efficiency) % 103 98 102 90 96 -
Water heating energy efficiency class A -
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 132 126 128 -
outlet 55°C Seasonal space heating eff. class A++ -
Average climate water General ηs (Seasonal space heating efficiency) % -
outlet 35°C Seasonal space heating eff. class -
Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20 20
55
Specifications
EHSXB-A + ERLQ-CV3/ERLQ-CW1
04P30A + 08P30A + 08P50A + 08P30A + 08P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A + 16P50A
Efficiency data EHSXB + ERLQ
004CV3 006CV3 006CV3 008CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 +016CW1
Heating capacity Nom. kW 4.53 / 3.98 / 4.26 / 3.47 6.06 / 5.78 / 5.14 / 4.60 7.78 / 7.27 / 5.53 / 5.51 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05 11.80 / 10.40 / 5.95 / 7.74 14.81 / 13.73 / 8.28 / 9.57 15.34 / 14.86 / 8.04 / 10.05
Cooling capacity Nom. kW 4.4 / 4.0 5.2 / 4.6 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1 15.1 / 11.7 16.1 / 12.6 16.8 / 13.1
Power input Heating Nom. kW 0.87 / 1.04 / 1.49 / 0.85 1.30 / 1.58 / 1.88 / 1.26 1.69 / 2.04 / 1.98 / 1.56 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 2.57 / 3.13 / 2.43 / 2.35 3.42 / 4.07 / 3.17 / 2.93 3.42 / 4.07 / 3.17 / 2.93
Cooling Nom. kW 1.05 / 1.41 1.43 / 1.85 4.55 / 4.30 5.44 / 5.10 6.18 / 5.72 4.55 / 4.30 5.44 / 5.10 6.18 / 5.72
COP 5.23 / 3.84 / 2.85 / 4.07 4.65 / 3.66 / 2.73 / 3.64 4.60 / 3.57 / 2.78 / 3.54 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15 4.38 / 3.32 / 2.45 / 3.29 4.27 / 3.34 / 2.58 / 3.22 4.10 / 3.22 / 2.44 / 3.15
EER 4.21 / 2.85 3.65 / 2.51 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29 3.32 / 2.72 2.96 / 2.47 2.72 / 2.29
Domestic hot water General Declared load profile L XL L XL XL
heating Average climate ηwh (water heating efficiency) % 103 98 108 90 99 84 84
Water heating energy efficiency class A A
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 132 126 128 130 127 128 130 127
outlet 55°C Seasonal space heating eff. class A++ A++
Average climate water General ηs (Seasonal space heating efficiency) % - -
outlet 35°C Seasonal space heating eff. class - -
Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20
56
Specifications
EHBH-CB + ERLQ-CV3/ERLQ-CW1
08CB3V/9W 08CB3V/9W
Indoor Unit EHBH 04CB3V 11CB3V/9W 16CB3V/9W 16CB3V/9W 11CB3V/9W 16CB3V/9W 16CB3V/9W
08CB9W 08CB9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 890x480x344
Weight Unit kg 41 43 45 43 45 43 44 45 44 45 43 44 45 44 45
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Domestic hot water Water side Min.~Max. °C 25~80 25~80
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 40 41 44 41 44
Sound pressure level Nom. dBA 26 27 30 27 30
Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25 (2.000~35 (2 -20 (2.000~35 (2
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 (3 66 (3 64 (3 66 (3
Cooling Nom. dBA 63 64 (4 66 (4 69 (4 64 (4 66 (4 69 (4
Sound pressure level Heating Nom. dBA 48 (3 49 (3 51 (5 52 (5 51 (5 52 (5
Cooling Nom. dBA 48 (3 49 (3 50 (3 50 (5 52 (5 54 (5 50 (5 52 (5 54 (5
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20
Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
57
Specifications
EHBH-CB + ERHQ-BW1/ERHQ-BV3
16CB9W
11CB3V + 11CB9W 16CB3V + 16CB9W 16CB3V + 16CB9W 11CB3V + 11CB9W 16CB3V + 16CB3V + 16CB9W
Efficiency data EHBH + ERHQ +
011BV3 + 011BV3 014BV3 + 014BV3 016BV3 + 016BV3 011BW1 + 011BW1 014BW1 016BW1 + 016BW1
014BW1
Heating capacity Nom. kW 11.20 / 10.30 14.00 / 13.10 16.00 / 15.20 11.32 / 10.98 14.50 / 13.57 16.05 / 15.11
Power input Heating Nom. kW 2.55 / 3.17 3.26 / 4.04 3.92 / 4.75 2.63 / 3.24 3.42 / 4.21 3.82 / 4.69
COP 4.39 / 3.25 4.29 / 3.24 4.08 / 3.20 4.30 / 3.39 4.24 / 3.22 4.20 / 3.22
Domestic hot water General Declared load profile -
heating Average climate ηwh (water heating efficiency) % -
Water heating energy efficiency class -
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118
outlet 55°C SCOP 2.93 2.91 2.94 3.00 2.98 3.03
Seasonal space heating eff. class A+
Average climate water General ηs (Seasonal space heating efficiency) % 118 130 127 123 118
outlet 35°C SCOP 3.02 3.32 3.25 3.24 3.14 3.10
Seasonal space heating eff. class A A+ A
Indoor Unit EHBH 11CB3V 11CB9W 16CB3V 16CB9W 16CB3V 16CB9W 11CB3V 11CB9W 16CB3V 16CB9W 16CB3V 16CB9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 890x480x344
Weight Unit kg 43 44 45 44 45 43 44 45 44 45
Operation range Heating Water side Min.~Max. °C 15~55
Domestic hot water Water side Min.~Max. °C 25~80
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 41 44 41 44
Sound pressure level Nom. dBA 27 30 27 30
58
Specifications
EHBX-CB + ERLQ-CV3/ERLQ-CW1
Indoor Unit EHBX 04CB3V 08CB3V/9W 08CB3V/9W 11CB3V/9W 16CB3V/9W 16CB3V/9W 11CB3V/9W 16CB3V/9W 16CB3V/9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 890x480x344
Weight Unit kg 42 44 45 44 45 43 45 44 46 44 46 43 45 44 46 44 46
Operation range Heating Water side Min.~Max. °C 15~55 15~55
Cooling Water side Min.~Max. °C 5~22 5~22
Domestic hot water Water side Min.~Max. °C 25~80 25~80
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 40 41 44 41 44
Sound pressure level Nom. dBA 26 27 30 27 30
Outdoor Unit ERLQ 004CV3 006CV3 008CV3 011CV3 014CV3 016CV3 011CW1 014CW1 016CW1
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320
Weight Unit kg 54 56 113 114
Compressor Quantity 1
Type Hermetically sealed swing compressor Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB 10.0~43.0 10.0~46.0
Domestic hot water Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A
Charge kg 1.5 1.6 3.4
TCO₂eq 3.1 3.3 7.1
GWP 2,087.5
Control Expansion valve (electronic type)
Sound power level Heating Nom. dBA 61 62 64 66 64 66
Cooling Nom. dBA 63 64 66 69 64 66 69
Sound pressure level Heating Nom. dBA 48 49 51 52 51 52
Cooling Nom. dBA 48 49 50 50 52 54 50 52 54
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400
Current Recommended fuses A 16 20 40 20
59
Specifications
EHBX-CB + ERHQ-BV3/ERHQ-BW1
11CB3V + 11CB9W + 16CB3V + 16CB9W + 16CB3V + 16CB9W + 11CB3V + 11CB9W + 16CB3V + 16CB9W + 16CB3V + 16CB9W +
Efficiency data EHBX + ERHQ
011BV3 011BV3 014BV3 014BV3 016BV3 016BV3 011BW1 011BW1 014BW1 014BW1 016BW1 016BW1
Heating capacity Nom. kW 11.20 (1 / 10.30 (2 14.00 (1 / 13.10 (2 16.00 (1 / 15.20 (2 11.32 (1 / 10.98 (2 14.50 (1 / 13.57 (2 16.05 (1 / 15.11 (2
Cooling capacity Nom. kW 13.9 (1 / 10.0 (2 17.3 (1 / 12.5 (2 17.8 (1 / 13.1 (2 15.1 (1 / 11.7 (2 16.1 (1 / 12.6 (2 16.8 (1 / 13.1 (2
Power input Heating Nom. kW 2.55 (1 / 3.17 (2 3.26 (1 / 4.04 (2 3.92 (1 / 4.75 (2 2.63 (1 / 3.24 (2 3.42 (1 / 4.21 (2 3.82 (1 / 4.69 (2
Cooling Nom. kW 3.86 (1 / 3.69 (2 5.86 (1 / 5.69 (2 6.87 (1 / 5.95 (2 4.53 (1 / 4.31 (2 5.43 (1 / 5.08 (2 6.16 (1 / 5.73 (2
COP 4.39 (1 / 3.25 (2 4.29 (1 / 3.24 (2 4.08 (1 / 3.20 (2 4.30 (1 / 3.39 (2 4.24 (1 / 3.22 (2 4.20 (1 / 3.22 (2
EER 3.60 (1 / 2.71 (2 2.95 (1 / 2.32 (2 2.59 (1 / 2.20 (2 3.32 (1 / 2.72 (2 2.96 (1 / 2.47 (2 2.72 (1 / 2.29 (2
Domestic hot water General Declared load profile -
heating Average climate ηwh (water heating efficiency) % -
Water heating energy efficiency class -
Space heating Average climate water General ηs (Seasonal space heating efficiency) % 114 113 115 117 116 118
outlet 55°C SCOP 2.93 2.91 2.94 3.00 2.98 3.03
Seasonal space heating eff. class A+
Average climate water General ηs (Seasonal space heating efficiency) % 118 130 127 130
outlet 35°C SCOP 3.02 3.32 3.25 3.24 3.14 3.10
Seasonal space heating eff. class A A+
Indoor Unit EHBX 11CB3V 11CB9W 16CB3V 16CB9W 16CB3V 16CB9W 11CB3V 11CB9W 16CB3V 16CB9W 16CB3V 16CB9W
Casing Colour White
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 890x480x344
Weight Unit kg 43 45 44 46 44 46 43 45 44 46 44 46
Operation range Heating Water side Min.~Max. °C 15~55
Cooling Water side Min.~Max. °C 5~22
Domestic hot water Water side Min.~Max. °C 25~80
Refrigerant Charge TCO₂eq -
GWP -
Sound power level Nom. dBA 41 44 41 44
Sound pressure level Nom. dBA 27 30 27 30
Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
60
Specifications
EDLQ-CV3/EBLQ-CV3
EKCB-CV3/EK2CB-CV3
EKMBUHC3V3/EKMBUHC9W1
61
Specifications
EKHWP-B
EKHWP-PB
62
Specifications
EKHWS-B3V3/EKHWS-B3Z2
EKHWE-A3V3/EKHWE-A3Z2
63
Specifications
6. Solar system
EKSH-P/EKSV-P
EKSRPS
Accessory EKSRPS 4
Mounting On side of tank
Dimensions Unit HeightxWidthxDepth mm 815x142x230
Weight Unit kg 6
Operation range Ambient temperature Min.~Max. °C 5~40
Operating pressure Max. bar 0
Stand still temperature Max. °C 85
Thermal collector efficiency (ηcol) % -
performance Zero loss collector efficiency η0 % -
Control Type Digital temperature difference controller with plain text display
Power consumption W 2
Power supply Phase/Frequency/Voltage Hz/V 1~/50/230
Power supply intake Indoor unit
EKSRDS2
Accessory EKSRDS2
Mounting On wall
Dimensions Unit HeightxWidthxDepth mm 410x314x154
Thermal performance Zero loss collector efficiency η0 % -
Control Type Digital temperature difference controller with plain text display
Power supply Frequency/Voltage V 50/230
64
Specifications
7. Controls
EKRUCBL/EKRUCBS
EKRTW/EKRTR
65
Trust Daikin
Daikin may not be a household name. After all, we don’t make cars, TVs, fridges or washing machines. But we do make world-class heat pumps.
In fact, more than 275,000 Daikin Altherma heat pumps have been fitted across Europe since its initial launch in 2006.Because we focus on doing
only what we’re best at: creating the most efficient heating, ventilation and air conditioning solutions, renowned for design excellence, quality
and reliability. So you can depend on Daikin for the ultimate in comfort, leaving you free to focus on other essentials.
Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)