Professional Documents
Culture Documents
vampair
Heating
Cooling
A+++
SCOP = 4,95
Medium climate at 35°C VLT
1.
Place www.topprodukte.at
Stand 08. 2019
2
Energy
is in
the air
The correct selection of the heating sys-
tem is an important decision that will
have an impact for many years. With
an air source heat pump you can heat
cost-effectively, especially in new built
low energy houses and systems with
medium flow temperatures.
3
Compact air source heat pump
Perfect for all seasons
Heating
Cooling
vampair - Energy from the air
Hot
water + Inverter technology adapts to the heat demand
+ Enhanced vapour injection for high flow temperatures
also at low outside temperatures (- 22°C)
+ Compact system with longer life time
4
How it works
The function of a heat pump is similar to that of a refrigerator, but reversed. By using an air heat ex-
changer (evaporator), energy is taken from the ambient air to heat up the heating water and the sani-
tary hot water.
Evaporator(1)
The evaporator is a heat exchanger that takes energy from ambient air and transforms it
to the circulating refrigerant to change its state from liquid to gaseous.
Condenser (3)
The absorbed thermal energy is delivered to the heating system. The gaseous refrigerant cools and
liquefies again.
With Inverter technology the output of the heat pump is constantly adjusted to the permanent temperature
Start
Set temperature
Stop
Cooling in summer
The compact heat pump vampair has
a cooling function as standard. Throu-
gh the weather forecasting function
(SOLARFOCUS Weatherman) an
overheating of the building is avoided
already at the outset and energy sa-
vings are achieved.
7
Low-Noise Technology
Silent isn’t enough?
The decisive factors to minimise
Fan
The radial-axial design combines the
best of two worlds. On the one hand
to achieve a straight air flow and on the
other hand a high efficient pressure
rise.
Thanks to the exceptional blade geo-
metry, there are hardly any air, perfor-
mance and deflection losses.
The EC technology (electronically com-
mutated motor) guarantees the highest
efficiencies.
8
unpleasant air noise are air turbulances
Fin evaporator
The finned evaporator consists of a hi- Your benefit
gh-quality aluminium-copper heat exchan-
ger with hydrophilic coating and generous + Low-Noise Technology
lamella distance of 3 mm. The hydrophilic + Hardly any air, performance and deflection
coating allows water to run faster and im-
losses
proves heat transfer from air to the refrige-
rant. In addition, this means that the evapo- + Optimum efficiency
rator ices up less quickly. + Fins protect against wind driven rain
+ No permanent defrosting of the heat pump
By contrast, the hydrophobic coating would
form large drops, which would then ice up
the evaporator quickly. The spherical wa-
ter drops block two fins and thus block the
path of the air.
The bigger
Fan and
Evaporators are,
the quieter and
more efficient the
heat pump!
9
Intelligent
smart
control
+ Intuitive control unit with 7“ touchscreen display
+ Takes the weather forecast into consideration
+ mySOLARFOCUS app
+ SmartGrid ready
71°C
Módulo solar 1
67 °C
77°C
0 l/h
63°C 0%
Solar
Circ. solar desconectado
SOLARFOCUS
server
Weather server
mySOLARFOCUS-App
10
Heating circuit
5
13:37:37
°C
09:11:31
ecomanager-touch control unit
24
18 6
12 If the heat pump is used in combination with a so-
Buffer tank 64 °C
31 °C Flow temperature
lar system, it only starts when the required heating
37 °C Flow set temperature energy cannot be provided in full by the solar sys-
0 % Mixer position
M
No request on buffer 1 tem. The ecomanager-touch is very easy to use. It ena-
Heating circuit in heating mode bles individual settings and ensures a perfectly tai-
lored heating management.
320 13
l/h PM 27.0 °C
16%
live data from a weather server and uses this to 32°C Preview
27°C 25°C
Tuesday Wednesday
Examp
house
1
le mySOLARFOCUS-App
Solar
circui
Statu
s: loadin t 1
Act. P
ower:
g tank
1 You can control the heating system even more
4300
W
comfortably with the mySOLARFOCUS app. In
Solar
Tempe
yield
combination with the Weatherman, it takes just a
ra ture
Monda Power few seconds to set your heating via your smartpho-
y, 12.
A ugust ne. And you can use it wherever you are: in the offi-
2018
ce, on your sofa or on holiday. App for smartphone
(Android and Apple) with attractive design for intui-
tive operation of the main heating parameters. Pos-
sibility to visualise the solar yield with the installed
heat meters and control unit via ecomanager-touch.
Day
We e k
Month
Year
11
Simple hydraulic integration
Air source heat pump vampair with a heating circuit and sanitary hot water tank
Air source heat pump vampair with a heating circuit, stratified buffer tank and fresh water module
FRESH WATER
FRISCHWASSER
SYSTEM
SYSTEM
FWMkonvent
Air source heat pump vampair with a heating circuit, stratified buffer tank with solar coil, fresh water
module, and solar installation
FRESH WATER
FRISCHWASSER
SYSTEM
SYSTEM
FWMkonvent
12
Technical data
Air source heat pump vampair
K 08 / K 10: 1090 mm
K 12 / K 15: 1325 mm
thermi natorthermi
II nator IItherminatorthermi
II nator IItherminatorthermi
II nator IItherminatortherm
II
I KII 08 / K nator
10:
III II866 mm
K 08 / K 10: 1580 mm I III thermi I II IItherminator
nator III thermi I II IItherminator
nator III thermi I II IItherminator
nator II therm
I I II thermi
Biomasseheizungen Solaranlagen
I II
Biomasseheizungen Solaranlagen
III II I II
Biomasseheizungen Solaranlagen
III II I II II II
Biomasseheizungen Solaranlagen Biomasseheizungen Solaranlagen
Biomasseheizungen Solaranlagen Biomasseheizungen Solaranlagen
Biomasseheizungen Solaranlagen
K 12 / K 15: 920 mm
Wärmepumpen Wärmepumpen
Frischwassertechnik Wärmepumpen
Frischwassertechnik Wärmepumpen
Frischwassertechnik Wärmepumpen
Frischwassertechnik Wärmepumpen
Frischwassertechnik Wärmepumpen
Frischwassertechnik Wärmepumpen
Frischwassertechnik Frischwassertechnik
K 12 / K 15: 1580 mm
Biomasseheizungen Solaranlagen
Biomasseheizungen Solaranlagen Biomasseheizungen Solaranlagen
Biomasseheizungen Solaranlagen Biomasseheizungen Solaranlagen
Biomasseheizungen Solaranlagen Biomasseheizungen Solaranlagen
Biomasseheizungen Solaranlagen
Wärmepumpen Wärmepumpen
Frischwassertechnik Wärmepumpen
Frischwassertechnik Wärmepumpen
Frischwassertechnik Wärmepumpen
Frischwassertechnik Wärmepumpen
Frischwassertechnik Wärmepumpen
Frischwassertechnik Wärmepumpen
Frischwassertechnik Frischwassertechnik
A
A-80% A
-80% -80%
A-80%
vampair K 08 K 10 A +++ A K 12
+++ A +++ A K
+++15A -60%
A A
+++A -60%+
A +++ A +++ A +++ A +++ A -60%A A
+++A -60%+
Pack label efficiency class heating 35°C / 55°C A
A+++ / A
+++ +++
A+++ A +++
A+++
A
A / A+++
+++++ +++
A
++++++ A
+++++ ++++++++ +++
A
+++
+++ / A A
+++
A A++ A A++ A A++ A A++ AA-40%
+++ A A
+++++ +++-40%
A
A
+++
+++ / AA+++
+++++ -40%
A
+++ A
++++
A
+++
A++ A-40%A+ A
A A
A A
A A
A
++ A + ++A + ++ A + ++A + A A
A + A++ + A++ + A++ + AA ++-20%+ +
A++ / A A A A
++ ++ ++ ++ -20%
Product label efficiency class heating 35°C / 55°C A++ A ++
/ A A A A / A A A A / AA A+ A-20% ++-20%
A+
A A A A+ A
A A A A+ A
A A A A+ A
A A
+ + + + + + + +
SCOPEN14825 moderate climate 35°C / 55°C A4,20
+
A+
/ 3,40 A+4,73 / 3,80 A A / 3,40
A+4,40 A A / 3,85
A+4,95 A A
A
A A
A A
A A
A B B A
A B B A
A B B A
A B B A
A B B B
s seasonal room heating efficiency, moderate B
B B B B
B %C B
B C B B B
C B C
195C% / 151
C B C C
165
climate 35 / 55 °C B % / 133B % 195
B % / 147 C
173 % / 133 %
C B %
C C
C
C 5,7 kW C
C C
C 7,8 kW C
C D C
C D C
C D C
C D C
C D D
Recommended building heat load1 up to D D
9,4 kW D D15 kW D D
D
D D
D D
D D
D E D
D E D
D E D
D E D
D E EE
Heat power at A7/W35 2,90 - 8 kW E
2,90 - 9,50 kW E - 14 kWE
4,70 E - 18 kWE
4,70
Max. heat power at A-10/W35 5,3 kW 7,0 kW F F FF9,4 kW FF FF13,7 kW FF FF
G GG10 kW G GG15 kW G G
22 kW
22 kW
22 kW
22 kW
22 kW
22 kW
22
Max. cooling power A35/W18 5 kW 6 kW
G G G G
Max. cooling power A35/W72 4 kW
kW kW kW
5 kW
kW kW kW 8 kW 13 kW
Execution:
Elektrical connection compressor 3/N/PE ~400V, 50 Hz / 1/N/PE ~230V, 50 Hz
Max. current compressor 8 A / 25A 12 A / 35A
Refrigerant R410A
Connections heating flow / return G5/4“ AG
Max. flow temperature heating 65°C
Air Temperature operating limits heating - 22°C / + 35°C
1580 / 1090 / 1580 / 1090 / 1580 / 1325 / 1580 / 1325 /
dimensions (W/H/D)
866 mm 866 mm 920 mm 920 mm
1
Recommended building heat load at standard outside temperature -14 ° C, outside temperature 15 ° C, system temperature 35 ° C,
taking into account 5% proportion of the peak load heat generator (without hot water). 2 with extension set Low temperature cooling.
SOLARFOCUS offers a perfect support for planning, offer and execution through a selection of
several thousand standard hydraulic schemes!
13
Thinking outside the box
is at the forefront of every product we develop. The Research, Development, Production, Quality Assu-
rance and Administration departments are found at the St. Ulrich site, SOLARFOCUS employs people
with a concern for the environment and the use of renewable energy.
THE PHILOSOPHY
Conscious sustainability
SOLARFOCUS is proud to work together to create
SOLARFOCUS brings together a future in such a way that it serves mankind and
simultaneously protects the environment.
what belongs together:
INNOVATIVE TECHNOLOGY + Strong partners
ADVANCED MANUFACTURING Success requires strong partners. SOLARFOCUS
passes on its comprehensive know-how directly
to heating engineers and installers. This guaran-
tees optimized planning of heating systems.
14
Lorsch (Deutschland)
15
Innovative products,
which protect the
environment and
relieve the purse.
Products for
Pellets Pellets + log wood Log wood Wood chips Solar energy Fresh water Heat Pump
Austria
SOLARFOCUS GmbH, Werkstraße 1, 4451 St. Ulrich/Steyr
e-mail: office@solarfocus.at Tel.: +43 (0) 7252 / 50 002 - 0
web: www.solarfocus.com Fax: +43 (0) 7252 / 50 002 - 10
Subject to technical modifications, typesetting and printing errors. The images used are symbolic
photos. All use is prohibited without the written consent of the copyright holder SOLARFOCUS.
Information provided without guarantee!