Heat Pumps
1
Heat Pumps
‒
CONTENTS
04 Overview
3
14 Yutaki S80
18 Yutaki S
22 Yutaki S Combi
28 Yutaki M
32 Yutampo II
36 Accessories
YUTAKI S80
HEATING, AIR CONDITIONING
AND DOMESTIC HOT WATER SUPPLY
RENEWABLE ENERGY SYSTEM
YUTAKI M
YUTAKI S
+60
Years of experience
in air conditioning
and heating
YUTAKI S COMBI
YUTAMPO II
+4.5
Millions of
heating systems
produced
+400 000
Customers
in Europe
Heat Pumps
AIR TO WATER
HEAT PUMP
A sustainable heating method The Yutaki model series is a unit called Air to water
heat pumps. This system uses heat from the air to
generate energy and serves for heating, cooling and
domestic hot water.
75 %
Heat transfer to the interior of the house The process starts again
In the heat exchanger, the refrigerant The refrigerant enters in the expansion
transfers its heat to the hydraulic circuit, valve, where it loses temperature
thereby supplying it the necessary energy for and pressure, and then returns to the
heating and domestic hot water. evaporator, for a continuous system.
AIR TO WATER
HEAT
‒
PUMP
ALL APPLICATIONS IN ONE SYSTEM
9
On cold days there is nothing like the
feeling of getting home, feeling that
you are in a warm and welcoming
space.
Discover the heat pump system,
renewable energy with low
consumption.
Heat Pumps
YUTAKI SERIES
‒
ADVANTAGES OF THE YUTAKI SERIES
RENEWABLE ENERGY,
GUARANTEED SAVINGS
Heat pump system has greater energy
01
efficiency because it produces more
energy than it consumes. COP = 5.25
means that the Yutaki heat pump
consumes only 20% of the electricity.
The remaining 80% of energy comes
from the outside air and is therefore
completely free.
02
15
11
thanks to their standard length, for
example, inside the kitchen unit.
The whole range also uses shared
accessories to facilitate installation and
subsequent maintenance.
IMPROVED OPERATION
OF THE DC-INVERTER
TECHNOLOGY
04 HITACHI WARRANTES
THE OPERATION OF
HITACHI scroll compressors with
THESE UNITS, EVEN
DC inverter increase the operational
efficiency of the installation up to
WHEN THE OUTDOOR
30% compared with traditional TEMPERATURE DROPS
compressors. This further reduces
energy consumption and increases TO -25 °C*.
system life.
Heat Pumps
*By model.
INCREASING EFFICIENCY
AND REDUCING
CONSUMPTION
05
If you compare the Yutaki unit with a
competitor unit of the same power,
the HITACHI air to water heat pump
consumption is significantly lower.
Why is that so? Because besides in
exceptional situations where outdoor
temperatures are extremely low, it is
not necessary to interfere with a backup
electric heater.
*See terms.
*Other accessories.
08
EASY MAINTENANCE
13
YUTAKI RANGE
Heat Pumps
R410A - H2O
heating demand is lower, the unit only uses
R410A refrigerant, while when the demand
is increased, the second refrigerant circuit
R134a is activated. Consumption is therefore
constantly under surveillance and comfort is
guaranteed. H2O
EXP. VENTIL
VZDUCH - R410A
R410A - R134a
R134a - H2O
AIR
R410A R134a
80 ºC
PERFECT SOLUTION
FOR BOILER CHANGE
15
Different configurations for every installation Always pure water
The Yutaki S80 is available in two versions to accommodate different The stainless steel filter, mounted in the DHW cylinde, limits the
requirements: the Combi version with the tank integrated in the unit formation of bacteria even when the water stays longer in the
(200l or 260l) or the Standard version dedicated to the space heating. tank (when you are on vacation).
This last option allows to connect a tank as an accessory.
The following schematic shows all the possibilities with this series.
Intelligent management
YUTAKI S80
Dimensions
1 591 mm
1 380 mm
1 282 mm
751 mm
950
600 mm 600 600
mm mm mm mm mm mm mm
YUTAKI S80 623 370 648 648
Heating working Outdoor air temp. °C (DB) -25 – +25 -25 – +25 -25 – +25 -25 – +25 -25 – +25 -25 – +25
range Water outlet temp. °C +20 – +80 +20 – +80 +20 – +80 +20 – +80 +20 – +80 +20 – +80
Outdoor air temp. °C (DB) -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35
DHW tank working range
Water outlet temp. °C +30 – +75 +30 – +75 +30 – +75 +30 – +75 +30 – +75 +30 – +75
Refrigerant R134a R134a R134a R134a R134a R134a
Refrigerant charge / GWP kg / CO2 ton 1.90 / 2.717 1.90 / 2.717 1.90 / 2.717 1.90 / 2.717 1.90 / 2.717 1.90 / 2.717
Compressor Scroll DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter
Height (incl. connection) mm 751 (802)* 751 (802)* 751 (802)* 751 751 751
Dimensions
Width mm 600 600 600 600 600 600
Depth (incl. connection) mm 623 623 623 623 (680)* 623 (680)* 623 (680)*
Weight kg 126 129 129 127 130 130
17
Pipe diameter (liquid-gas) mm 9.52–15.88 9.52–15.88 9.52–15.88 9.52–15.88 9.52–15.88 9.52–15.88
Maximum length m 75 75 75 75 75 75
Maximum height difference m 30/20 30/20 30/20 30/20 30/20 30/20
+10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 /
Operating ranges
°C (DB) -25 – +25 / -25 – +25 / -25 – +25 / -25 – +25 / -25 – +25 / -25 – +25 /
(cooling/heating/DHW)
-25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35
Refrigerant R410A R410A R410A R410A R410A R410A
Refrigerant charge (maximum pipe length without
kg / CO2 ton 3.30 (60) / 6.890 3.40 (60) / 7.099 3.40 (60) / 7.099 3.30 (60) / 6.890 3.40 (60) / 7.099 3.40 (60) / 7.099
additional charge) / GWP
Compressor Scroll DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter
Dimensions (Height × Width × Depth) mm 1 380 × 950 × 370 1 380 × 950 × 370 1 380 × 950 × 370 1 380 × 950 × 370 1 380 × 950 × 370 1 380 × 950 × 370
Weight kg 103 103 103 103 103 103
* Corresponds to the height of the unit with a minimum mounting height. This value can be adjusted up to +30 mm
Heat Pumps
(1) Rated cooling and heating capacity is based on EN14511 and the following conditions:
– Cooling: Inlet water temperature 12°C and outlet water temperature 7°C; outdoor temperature 35°C (DB).
– Heating: Inlet water temperature 30°C and outlet water temperature 35°C; outdoor temperature 7°C (DB), 6°C (WB).
Pipe length 7.5 m; height difference of the pipe 0 m.
(2) A
coustic level measurement is performed under the following conditions:
Outdoor temperature: 7°C (DB) / 6°C (WB) Inlet and outlet water temperature: 30/35°C. Measurement of the acoustic level is done in an
acoustic chamber 1 meter from the front surface and 1.5 meters above the ground. The sound pressure level is measured in a reflecting
chamber in accordance with standard EN12102. Ambient conditions are defined in EN 14511.
Note: The RWH-4X.XVNFE (without integrated DHW cylinder) is compatible with third-party storage.
‒
YUTAKI S
Installation: water tank The scheme shows the installation
+ 2 different heating of a Yutaki S + DHWT (with or without
backup electrical heater) using two
circuits, high and low
SMALL SIZE: MODELS temperature
different systems at the same time: high
temperature with radiators up to 60°C
WITH PERFORMANCE and low temperature system operating
at 35°C with underfloor heating circuit.
OF 4.30-7.50 KW CAN BE A second temperature control set is
INSTALLED DIRECTLY IN needed.
KITCHENS
TTUV
SECOND
TEMPERATURE
KIT
T W02
YUTAKI S T WPII
ELECTRIC T MIX
HEATER
HEAT
EXCHANGER MOTORIZED
VALVE
PRIMARY
WATER PUMP
3-WAY
The best cop of the market R410A
VALVE
The new Yutaki S series has a 15 % improved H2O 1ST CIRCUIT:
RADIATORS (50–60 °C)
2ND CIRCUIT: UNDERFLOOR
HEATING (30–35 °C)
thermal efficiency compared to previous
models. This means that it has the highest
COP (5.25) value compared to other brand
models.
19
Compliance with all requirements Installation scheme The installation scheme is simpler
without the domestic hot as there is not the priority need of
In addition to the wide power range offered domestic hot water production, the
by Yutaki S from 4.30 kW to 24 kW, a new 6.00 water tank heated water flows directly in the first
kW unit is available, which is unique on the circuit (high temperature) and then to
market. the second one (low temperature) for
the underfloor heating
YUTAKI S
YUTAKI S MINI YUTAKI S MEDIUM YUTAKI S BIG T W02
4.30–7.50 KW 11.00–16.00 KW 20.00–24.00 KW BASIC HEATER T WPII SECONDARY
WATER PUMP
HEAT EXCHANGER T MIX MOTORIZED
VALVE
EXPANSION VESSEL
OUTDOOR HYDRAULIC
UNIT DISTRIBUTOR
SECOND
TEMPERATURE KIT
H2O
R410A
appropriate lifestyle.
YUTAKI S
A+++ ‒
YUTAKI S
Pressure valve
Pressure
THE Yutaki S can cover every Safety valve switch
Its compact size and easy High efficiency pump PCB Box
(complying with
installation make it a unit the ErP code)
Dimensions
890 mm
890 mm
712 mm
520 670
450 mm
mm m mm m
5m 0m mm
27 36 360
YUTAKI S
792 950
mm mm
mm mm
300 370
RAS- RAS- RAS- RAS- RAS- RAS- RAS- RAS- RAS- RAS- RAS-
Outdoor unit 2WHVNP 2.5WHVNP 3WHVNP 4WHVNPE 5WHVNPE 6WHVNPE 4WHNPE 5WHNPE 6WHNPE 8WHNPE 10WHNPE
Heating kW 0.77 1.21 1.60 2.12 2.90 3.43 2.12 2.90 3.43 4.58 5.51
21
Rated power (1)
Cooling kW 1.17 1.54 2.14 2.11 2.87 3.65 2.11 2.87 3.65 4.41 6.15
Heating kW 4.30 (7.00) 6.00 (9.00) 7.50 (11.00) 11.00 (15.20) 14.00 (16.70) 16.00 (17.80) 11.00 (15.20) 14.00 (16.70) 16.00 (17.80) 20.00 (25.50) 24.00 (32.00)
Max capacity (1)
Cooling kW 3.80 (4.90) 5.00 (5.80) 6.00 (7.00) 7.20 (11.80) 9.50 (12.60) 10.50 (13.70) 7.20 (11.80) 9.50 (12.60) 10.50 (13.70) 14.00 (16.40) 17.50 (20.60)
COP 7 °C outdoor / 30–35 °C water 5.25 4.80 4.55 5.00 4.71 4.57 5.00 4.71 4.57 4.30 4.29
EER 35 °C outdoor / 7–12 °C water 3.12 3.15 2.75 3.30 3.54 3.31 3.30 3.54 3.31 3.12 2.81
Energy Class at 35 °C A+++ A+++ A++ A+++ A+++ A++ A+++ A+++ A++ A++ A+
1 ~230 V 1 ~230 V 1 ~230 V 1 ~230 V 1 ~230 V 1 ~230 V 3 ~400 V 3 ~400 V 3 ~400 V 3 ~400 V 3 ~400 V
Power supply
50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz
Sound pressure (2) dB(A) 46 47 50 49 50 50 49 50 50 59 60
Sound performance (2) dB(A) 59 60 61 63 64 65 63 64 65 71 72
Air flow m3/h 2 436 2 436 2 682 4 800 5 400 6 000 4 800 5 400 6 000 7 620 8 040
Pipe diameter (liquid-gas) mm 6.35–12.7 6.35–12.7 9.52–15.88 9.52–15.88 9.52–15.88 9.52–15.88 9.52–15.88 9.52–15.88 9.52–15.88 9.52–25.4 12.7–25.4
Maximum length m 50 50 50 75 75 75 75 75 75 70 70
Maximum height difference 30/20 30/20 30/20 30/20 30/20 30/20 30/20 30/20 30/20 30/20 30/20
+10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 /
Operating ranges
°C (DB) -15 – +25 / -15 – +25 / -15 – +25 / -25 – +25 / -25 – +25 / -25 – +25 / -25 – +25 / -25 – +25 / -25 – +25 / -25 – +25 / -25 – +25 /
(cooling/heating/DHW)
-15 – +35 -15 – +35 -15 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant charge
kg (m) / 1.40 (30) / 1.50 (30) / 1.70 (40) / 3.30 (60) / 3.40 (60) / 3.40 (60) / 3.30 (60) / 3.40 (60) / 3.40 (60) / 5.00 / 5.30 /
(maximum pipe length without
CO2 ton 2.923 3.312 3.550 6.890 7.099 7.099 6.890 7.099 7.099 10.440 11.066
additional charge) / GWP
Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC
Compressor
inverter inverter inverter inverter inverter inverter inverter inverter inverter inverter inverter
Dimensions
mm 600×792×300 600×792×300 600×792×300 1 380×950×370 1 380×950×370 1 380×950×370 1 380×950×370 1 380×950×370 1 380×950×370 1 380×950×370 1 380×950×370
(Height × Width × Depth)
Weight kg 43 43 44 103 103 103 103 103 103 137 139
Heat Pumps
(1) Rated cooling and heating capacity is based on EN14511 and the following conditions:
– Cooling: Inlet water temperature 12°C and outlet water temperature 7°C; outdoor temperature 35°C (DB).
– Heating: Inlet water temperature 30°C and outlet water temperature 35°C; outdoor temperature 7°C (DB), 6°C (WB).
Pipe length 7.5 m; height difference of the pipe 0 m.
* Without the need to integrate a protective galvanizing anode to protect against corrosion.
The space required to install this unit The Yutaki S Combi series includes a new New LCD screen for easy operation. The
was reduced by up to 70% thanks a new 6.00 kW, which is ideal for small installations remote control features various functions,
construction that includes a water tank and extends the range of available power such as a weekly timer or energy-saving
inside the unit. You can choose a 200 or 260 from 4.30 to 16.00 kW. mode for a water pump..
liters tank.
23
The Yutaki S Combi unit offers a plug-
and-play installation. The only required
elements are to connect the refrigerant
circuit and power supply between outdoor
and indoor units to enable the unit to start.
Hydraulic installation does not require any
additional components; only needs to be
connected directly to the internal module.
YUTAKI S COMBI
4.30–16.00 KW
3-IN-1 SOLUTION
FOR THE PRODUCTION
OF HEAT, COOL
& HOT WATER
Heat Pumps
YUTAKI S COMBI
A+++ ‒
YUTAKI S COMBI
YUTAKI S COMBI
Dimensions
1 750 mm
1 380 mm
600 mm
792 950
mm mm 600
mm mm
mm
300 370 mm
YUTAKI S COMBI 733
Heating working Outdoor air temp. °C (DB) -20 – +25 -20 – +25 -20 – +25 -25 – +25 -25 – +25 -25 – +25 -25 – +25 -25 – +25 -25 – +25
range Water outlet temp. °C +20 – +55 +20 – +55 +20 – +55 +20 – +60 +20 – +60 +20 – +60 +20 – +60 +20 – +60 +20 – +60
Cooling working Outdoor air temp. °C (DB) +10 – +46 +10 – +46 +10 – +46 +10 – +46 +10 – +46 +10 – +46 +10 – +46 +10 – +46 +10 – +46
range Water outlet temp. °C +5 – +22 +5 – +22 +5 – +22 +5 – +22 +5 – +22 +5 – +22 +5 – +22 +5 – +22 +5 – +22
DHW tank working Outdoor air temp. °C (DB) -15 – +35 -15 – +35 -15 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35
range Water outlet temp. °C +30 – +75 +30 – +75 +30 – +75 +30 – +75 +30 – +75 +30 – +75 +30 – +75 +30 – +75 +30 – +75
Height (incl.
mm 1 750 (1 816) * 1 750 (1 816) * 1 750 (1 816) * 1 750 (1 816) * 1 750 (1 816) * 1 750 (1 816) * 1 750 (1 816) * 1 750 (1 816) * 1 750 (1 816) *
Dimensions connection)
Width mm 600 600 600 600 600 600 600 600 600
Depth mm 733 733 733 733 733 733 733 733 733
Net weight with 200l tank kg 121 122 122 120 122 122 120 122 122
Net weight with 260l tank kg 135 135 136 139 141 141 139 141 141
Net weight with solar combination (260l) kg 131 132 132 130 132 132 130 132 132
Outdoor unit RAS-2WHVNP RAS-2.5WHVNP RAS-3WHVNP RAS-4WHVNPE RAS-5WHVNPE RAS-6WHVNPE RAS-4WHNPE RAS-5WHNPE RAS-6WHNPE
Heating kW 0.82 1.25 1.65 2.20 2.97 3.50 2.20 2.97 3.50
Rated power (1)
25
Cooling kW 1.22 1.59 2.18 2.18 2.95 3.72 2.18 2.95 3.72
Heating kW 4.30 (7.00) 6.00 (9.00) 7.50 (11.00) 11.00 (15.20) 14.00 (16.70) 16.00 (17.80) 11.00 (15.20) 14.00 (16.70) 16.00 (17.80)
Max capacity (1)
Cooling kW 3.80 (4.90) 5.00 (5.80) 6.00 (7.00) 7.20 (11.80) 9.50 (12.60) 10.50 (13.70) 7.20 (11.80) 9.50 (12.60) 10.50 (13.70)
COP 7 °C outdoor / 30–35 °C water 5.25 4.80 4.55 5.00 4.71 4.57 5.00 4.71 4.57
EER 35 °C outdoor / 7–12 °C water 3.12 3.15 2.75 3.30 3.54 3.31 3.30 3.54 3.31
Energy Class at 35 °C A+++ A+++ A++ A+++ A+++ A++ A+++ A+++ A++
Power supply 1 ~230 V 50 Hz 1 ~230 V 50 Hz 1 ~230 V 50 Hz 1 ~230 V 50 Hz 1 ~230 V 50 Hz 1 ~230 V 50 Hz 3 ~400 V 50 Hz 3 ~400 V 50 Hz 3 ~400 V 50 Hz
Sound pressure (2) dB(A) 46 47 50 49 50 50 49 50 50
Sound performance (2) dB(A) 61 63 64 64 65 67 64 65 67
Air flow m3/h 2 436 2 436 2 682 4 800 5 400 6 000 4 800 5 400 6 000
Pipe diameter (liquid-gas) mm 6.35–12.7 6.35–12.7 9.52–15.88 9.52–15.88 9.52–15.88 9.52–15.88 9.52–15.88 9.52–15.88 9.52–15.88
Maximum length m 50 50 50 75 75 75 75 75 75
Maximum height difference 30/20 30/20 30/20 30/20 30/20 30/20 30/20 30/20 30/20
+10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 / +10 – +46 /
Operating ranges
°C (DB) -15 – +25 / -15 – +25 / -15 – +25 / -25 – +25 / -25 – +25 / -25 – +25 / -25 – +25 / -25 – +25 / -25 – +25 /
(cooling/heating/DHW)
-15 – +35 -15 – +35 -15 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant charge
kg (m) / 1.40 (30) / 1.50 (30) / 1.70 (40) / 3.30 (60) / 3.40 (60) / 3.40 (60) / 3.30 (60) / 3.40 (60) / 3.40 (60) /
(maximum pipe length
CO2 ton 2.923 3.132 3.550 6.890 7.099 7.099 6.890 7.099 7.099
without additional charge) / GWP
Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC Scroll DC
Compressor
inverter inverter inverter inverter inverter inverter inverter inverter inverter
Dimensions (Height × Width × Depth) mm 600 × 792 × 300 600 × 792 × 300 600 × 792 × 300 1 380 × 950 × 370 1 380 × 950 × 370 1 380 × 950 × 370 1 380 × 950 × 370 1 380 × 950 × 370 1 380 × 950 × 370
Weight kg 43 43 44 103 103 103 103 103 103
(1) Rated cooling and heating capacity is based on EN14511 and the following conditions:
Heat Pumps
– Cooling: Inlet water temperature 12°C and outlet water temperature 7°C; outdoor temperature 35°C (DB).
– Heating: Inlet water temperature 30°C and outlet water temperature 35°C; outdoor temperature 7°C (DB), 6°C (WB).
Pipe length 7.5 m; height difference of the pipe 0 m.
* Corresponds to the height of the unit a minimum mounting height. This value can be adjusted up to +30 mm.
**260 l compatible with RWD-2.0~6.0NWSE models, which combines with a solar panel.
YUTAKI S COMBI
A+++ LITE
‒
YUTAKI S COMBI LITE
Dimensions
1 750 mm
548 mm
600 mm
Heating working Outdoor air temp. °C (DB) -15 – +25 -15 – +25
range Water outlet temp. °C +20 – +55 +20 – +60
Cooling working Outdoor air temp. °C (DB) +10 – +43 +10 – +43
range Water outlet temp. °C +5 – +22 +5 – +22
Outdoor air temp. °C (DB) -15 – +35 -15 – +35
DHW tank working range
Water outlet temp. °C +30 – +75 +30 – +75
Height (incl.
mm 1 750 (1 816) * 1 750 (1 816) *
Dimensions connection)
Width mm 600 600
Depth mm 733 733
Weight with 200l tank kg 99 99
27
Power supply 1 ~230 V 50 Hz 1 ~230 V 50 Hz
Sound power (2) dB(A) 63 63
Air flow m3/min 40.6 40.6
Pipe diameter (liquid-gas) mm 6.35–9.52 6.35–12.7
Maximum length m 20 20
Maximum height difference 10 10
Operating ranges (cooling/heating/DHW) °C (DB) +10 – +43 / -15 – +25 / -15 – +35 +10 – +43 / -15 – +25 / -15 – +35
Refrigerant R410A R410A
Refrigerant charge (maximum pipe length kg (m) /
1.20 (24) / 2.506 1.20 (24) / 2.506
without additional charge) / GWP CO2 ton
Compressor Scroll DC inverter Scroll DC inverter
Dimensions (Height × Width × Depth) mm 548 × 841 × 335 600 × 883 × 345
Weight kg 33 41
Heat Pumps
(1) Rated cooling and heating capacity is based on EN14511 and the following conditions:
– Cooling: Inlet water temperature 12°C and outlet water temperature 7°C; outdoor temperature 35°C (DB).
– Heating: Inlet water temperature 30°C and outlet water temperature 35°C; outdoor temperature 7°C (DB), 6°C (WB).
Pipe length 7.5 m; height difference of the pipe 0 m.
29
SIMPLE COMPACT
INSTALLATION
WITHOUT CONNECTING
THE REFRIGERATOR
CIRCUIT
* Available accessory.
even under the costs and time are also minimal because
almost no piping is required, there are no
is always tailored to your needs.
Heat Pumps
Safety valve
Expansion vessel
YUTAKI M 4-6 HP
Dimensions
1 380 mm
800 mm
12 12
52 52
YUTAKI M mm
m
mm
370
m mm
370
Heating working Outdoor air temp. °C (DB) -25 – +25 -25 – +25 -25 – +25 -25 – +25 -25 – +25 -25 – +25 -25 – +25
range Water outlet temp. °C +20 – +55 +20 – +60 +20 – +60 +20 – +60 +20 – +60 +20 – +60 +20 – +60
Cooling working Outdoor air temp. °C (DB) +10 – +46 +10 – +46 +10 – +46 +10 – +46 +10 – +46 +10 – +46 +10 – +46
range Water outlet temp. °C +5 – +22 +5 – +22 +5 – +22 +5 – +22 +5 – +22 +5 – +22 +5 – +22
DHW tank working Outdoor air temp. °C (DB) -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35 -25 – +35
range Water outlet temp. °C +30 – +75 +30 – +75 +30 – +75 +30 – +75 +30 – +75 +30 – +75 +30 – +75
Refrigerant R410A R410A R410A R410A R410A R410A R410A
Refrigerant charge / GWP kg/ CO2 ton 2.40 / 5.011 2.80 / 5.846 3.10 / 6.473 3.10 / 6.473 2.80 / 5.846 3.10 / 6.473 3.10 / 6.473
Compressor Scroll DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter Scroll DC inverter
Height (incl. onnection) mm 800 1 380 1 380 1 380 1 380 1 380 1 380
Dimensions Width mm 1 252 1 252 1 252 1 252 1 252 1 252 1 252
Depth mm 370 370 370 370 370 370 370
Weight kg 87 131 133 133 131 133 133
31
Heat Pumps
(1) Rated cooling and heating capacity is based on EN14511 and the following conditions:
– Cooling: Inlet water temperature 12°C and outlet water temperature 7°C; outdoor temperature 35°C (DB).
– Heating: Inlet water temperature 30°C and outlet water temperature 35°C; outdoor temperature 7°C (DB), 6°C (WB).
Pipe length 7.5 m; height difference of the pipe 0 m.
‒
your heat pump will be lower by how much the COP
will be. YUTAMPO II has one of the best COPs on the
market - from 1kW of electricity consumed, it supplies
YUTAMPO II
up to 3.2 kW of energy to the DHW tank (under nominal
operating conditions)
(1)
33
Silent indoor unit. Like all HITACHI heat pumps,
have household equipment to
guarantee the lowest operating it is not a direct source of CO2
costs. emissions. (CO2 only occurs when
producing electricity).
Thanks to the energy efficiency
of Hitachi heat pumps and air
Scale noise On average, 5x lower CO2
conditioners, your electricity
emissions.(2)
(Performance in consumption will be at least 3
decibels by model) times lower.
By placing the tray in a heated
How is it possible? Thanks to the room, heat losses are reduced by
80 dB (A) certified CUT of the YUTAMPO II the surface of the device.
road transport heater, which reaches up to 3.2.
74 dB(A) Think about it: the COP factor
washing machine Two tank sizes available
of 3.2 means that for 1 kW of 190 and 270 liters suit every home
electricity consumed, 3.2 kW of and need.
heated water!!
63 dB(A)
YUTAMPO II
outdoor unit
44 dB(A)
forest quenching
HOT WATER
Heat Pumps
0 dB(A)
SUPPLY
YUTAMPO II
indoor unit
(1) Model with 190 l capacity.
(2) Compared to solid fuel solid fuel heaters.
HITACHI
YUTAMPO II
CONFIRM YOUR
‒
EXPECTATIONS
YUTAMPO II
60
OVER
YEARS
EXPERIENCES
IN AIR CONDITIONING
AND HEATING
SIMPLIFIED
CONTROL
4.5 MILLIONS
OVER
WATER Universal intuitive
TREATMENT AND driver common to all
WATER CLEANING
HEAT PUMPS devices, alligned with
the Yutaki range:
PRODUCED ANUALLY . The hot water tank . hourly schedules
IN THE WORLD is made of high . required domestic hot
quality stainless water temperature
steel designed
for contact with
drinking water. Its
insulating properties
and the antibacterial
. Compressor developed
and manufactured by
3.2
Hitachi incorporates WATER HEAT
Inverter technology.
SPEED
Thanks to it, the heat
pump can adapt its
Up to performance exactly
. Thanks to high
to the actual needs of heating performance
HIGH COP users. This technology YUTAMPO is one of
reduces energy the fastest hot water
consumption by 30% heaters on the market,
and thus your account the entire tray can be
CONSUMPTION 1 kW for electricity. heated to exactly the
desired temperature
= 3.2 kW
in 3 hours 15 minutes
(the small version).
SUPPLIED ENERGY
TECHNICAL DATA
YUTAMPO II
Weight kg 49 54
Weight
35
kg 33
(1) V
alue at 7 ° C air temperature and 10 ° C cold water temperature according to LCIE Nº 103-15 / B: 2011
according to NF EN 16147: 2011, with cooling pipe connection 7 m long and no difference in height.
Heat Pumps
‒
ACCESSORIES TO ENLARGE
THE YUTAKI RANGE
YUTAKI CASCADE CONTROL
for all Yutaki models
All modules operate as a single unit with a bigger total capacity without
waste of energy: the second module switch on only when the first one
is not able to cover alone the demand and so will do the third and the
next ones.
The master controller is also smart, alternating the selection of the first
unit in usage (in this way we avoid the possibility to have a module
worn out after a small period of time) and establishing when is the
proper moment to activate the defrost function for each Yutaki system.
37
HEATING CAPACITY
HEATING DEMAND
Heat Pumps
YUTAKI CASCADE CONTROL (cont.)
for all Yutaki models
With this new type of installation we do not loose any benefit of the
single module, we increase them!
The installation will be able to heat, cool and produce sanitary water
in a faster way due to the increase of the capacity. At the same time we
maintain the possibility to link the biggest domestic renewable energy
system with your gas boiler, have 8 different circuits in order to separate
the climate zones of your building and a third circuit developed for your
swimming pool.
YUTAKI CASCADE CONTROL (cont.) SCHEME 1
for all Yutaki models
39
SCHEME 3
Heat Pumps
YUTAKI CASCADE CONTROL (cont.)
for all Yutaki models
490
Working range ºC 0 to 40
* Compatible with a wide range of Yutaki. * Compatible with a wide range of Yutaki.
41
INTELLIGENT WIRELESS THERMOSTAT FOR THE SECOND WATER
CIRCUIT
ATW-RTU-06*
Room thermostat for temperature control in the second room, easy to
install and offers multifunctional capabilities. For use with intelligent
thermostat applications.
SMART PHONE
ATW-TAG-02 CLOUD
YUTAKI
HI-BOX YUTAKI ADSL ROUTER,
AHP-SMB-01 WI-FI PC
HI-KUMO APP
TABLET
43
HOW CAN YOU HELP YOU?
Turn on or off heating or air conditioning Program the temperature in one or several Detects drive failures quickly and saves time
from anywhere. rooms to ensure maximum comfort with the history of alert codes.
You do not even have to be at home. (holiday mode, weekly).
Heat Pumps
DOWNLOAD FREE:
−
JOHNSON CONTROLS HQ HOLDING
SPARE PARTS
www.easyparts.johnsoncontrols.com
Tel : +44 (0) 1268 246 400
Email : be-parts-hitachi@jci.com HITACHI. TOTAL WARRANTY ON COMPRESSORS
WARRANTY COMPRESSOR
www.hitachi-hvac.com/en
The specifications of this catalog may change without prior notice to allow Find the products Hitachi
HITACHI C&H to incorporate the latest innovations for its customers. The
C&H with the best service
information contained in this catalog is merely informative. HITACHI C&H declines
any responsibility in the broadest sense, for damage, direct or indirect, arising and conditions at your
from the use and / or interpretation of the recommendations in this catalog Hitachi Distributor.