ADAM-4017
DATA CODE INPUT RANGE
ACQUISITION 08 ±10 V
MODULE 09 ±5 V
0A ±1 V
0B ±500 mV
0C ±100 mV
INPUT: 0D ±20 mA
STRAIN GAUGE
mV, V, mA

OUPUT:
RS-485
(Y) DATA+

(G) DATA-

(B) GND
(R) +Vs
Vin 5+

Vin 6+

Vin 7+
AGND
Vin 5-

INIT*

ADAM-4000 3-25
Vin 4-

Vin 3-

Vin 2-

Vin 1-

Vin 0-
Vin 4+

Vin 3+

Vin 2+

Vin 1+

Vin 0+
ADAM-4018
DATA CODE INPUT RANGE
ACQUISITION 00 ±15 mV
MODULE 01 ±60 mV
02 ±100 mV
03 ±500 mV
04 ±1 V
INPUT: 05 ±2.5 V
mV, V, mA 06 ±20 mA
Thermocouple DE T/C J
DF T/C K
10 T/C T
11 T/C E
OUPUT: 12 T/C R
RS-485 13 T/C S
14 T/C B
(Y) DATA+

(G) DATA-

(B) GND
(R) +Vs
Vin 5+

Vin 6+

Vin 7+
AGND
Vin 5-

INIT*

3-26 ADAM-4000
CHAPTER 3

Vin 4-

Vin 3-

Vin 2-

Vin 1-

Vin 0-
Vin 4+

Vin 3+

Vin 2+

Vin 1+

Vin 0+
ADAM-4018M
DATA CODE INPUT RANGE
ACQUISITION 00 ±15 mV
MODULE 01 ±60 mV
02 ±100 mV
03 ±500 mV
04 ±1 V
INPUT: 05 ±2.5 V
mV, V, mA 06 ±20 mA
Thermocouple DE T/C J
DF T/C K
10 T/C T
11 T/C E
OUPUT: 12 T/C R
RS-485 13 T/C S
14 T/C B
(Y) DATA+

(G) DATA-

(B) GND
(R) +Vs
Vin 5+

Vin 6+

Vin 7+
AGND
Vin 5-

INIT*

ADAM-4000 3-27
-
Vin0-
V mV/V
11 Vin0+
+

Vin5+
1

Vin5-
+
Vin6+
mV/V
AGND
-
Vin7+

3-28 ADAM-4000
CHAPTER 3

ADAM-4000 3-29
3-30 ADAM-4000
CHAPTER 3

ADAM-4000 3-31
DI15 INIT* DI15 INIT*

DI15 INIT*

3-32 ADAM-4000
CHAPTER 3

ADAM-4000 3-33
3-34 ADAM-4000
CHAPTER 3

ADAM-4000 3-35
3-36 ADAM-4000
CHAPTER 3

ADAM-4000 3-37
3-38 ADAM-4000
CHAPTER 3

ADAM-4000 3-39
3-40 ADAM-4000
CHAPTER 3

ADAM-4000 3-41
3-42 ADAM-4000
ADAM-4000
IN 0 DO 1

GATE 0 DO 0

D.GND IN 0+

IN 1

(Non-isolation)
IN 0-
ACQUISITION
DATA

MODULE

GATE 1 GATE 0+
51
50
CODE

INIT* GATE 0-

(Y) DATA+ IN 1+

(G) DATA- IN 1-
COUNTER
FREQUENCY
INPUT RANGE

(R) +Vs GATE 1+


ADAM-4080

(B) GND GATE 1-

3-43
CHAPTER 3
3-44
IN 0 DO 1/HI

GATE 0 DO 0/LO

D.GND IN 0+

IN 1

(Non-isolation)
IN 0-

ACQUISITION
DATA
GATE 1 51 MODULE GATE 0+
50
CODE

INIT* GATE 0-
(Photo-isolation)

(Y) DATA+ IN 1+

(G) DATA- IN 1-
COUNTER
FREQUENCY
INPUT RANGE

(R) +Vs GATE 1+


ADAM-4080D

(B) GND GATE 1-

ADAM-4000