15°
M4 Through-beam M6 Reflective
Without lens
60°
Series
Long-term stable detection Stable Detection Even for Prevents false detection of light that
in dust environment Workpieces with Low Reflection is reflected off surrounding objects
Through- Comparisons of incident level(digital value) Reflective Comparisons of incident level(digital value)
beam Stable detection in narrow locations
1403 325 150mm
1m
Build-in Lens Previously* * models without Build-in Lens Previously* * models without * models without
E32-LT11R lenses. E32-LD11R lenses. lenses.
Approximately 10 times the light intensity of Approximately 3.5 times the light intensity of Aperture angle of 15° greatly reduces false
conventional models. High power achieves conventional models. Differences in incident detection due to reflected light in narrow
long-term stable detection. level are increased even for black workpieces locations.
to provide stable detection.
No Need to Ever Attach a Lens Point
Easy Reliable
The clear spot simplifies
Reduced work in No worries about loosing a lens onsite adjustments.
selection and attachment
Approximately
350mm Previously*
Approximately
No lens 80mm
attachment
is required! Build-in Lens
No Protrusion! No Falling!
There is no need to select a combination There is no need to worry about a lens Comparison with Fiber Unit without a Lens
with a Sensing Distance of 300 mm
with a lens or attach a lens delicately. falling off and getting mixed with the
(Spots Overlapped in the Center)
The lens also does not protrude for neater workpieces or about ordering a new lens * models without lenses.
installation. when one is lost.
Application
The high power provides stable The high power lets the light Aperture angle of 15° ensures Aperture angle of 15° also
detection even in environments penetrate the backing material stable detection even with ensures stable detection without
containing paper dust. for stable label detection narrowly spaced workpieces. an error even if there are objects
near small devices.
Environmental Immunity Transparent Objects Beam Improvements Saving Space Standard Installation
Threaded
Through-beam Fiber Units Cylindrical
Specifications
Type Sensing distance (mm) Optical axis
Bending diameter
Sensing Aperture Appearance (mm) radius E3X-HD E3NX-FA (minimum Models Flat
direction angle of cable sensing
GIGA HS Other modes GIGA HS Other modes object) Sleeved
* *
4,000 * 4,000 *
ST : 4,000 ST : 4,000
R25 2,700 SHS: 1,080 * E32-LT11 2M
4,000 SHS: 1,080 Small
2.3 dia. Spot
Top-view 15° 15
(0.1 dia./ High
* *
4,000 4,000 * 0.03 dia.) Power
M4 ST : 3,500 ST : 4,000
Flexible, Narrow
E32-LT11R 2M
R1 2,300 SHS: 920 3,450 SHS: 920 view
IP50 BGS
* The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs) Retro-
reflective
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and SHS: Super-high-speed mode (30 μs)
Limited-
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode with the sensing distance and sensitivity set to the optimum values. reflective
The first value is for the E3X-HD and the second value is for the E3NX-FA.
Dimensions (mm)
M4×0.7 (Trivalent chrome-plated zinc alloy)
E32-LT11 2M/E32-LT11R 2M Chemical-
Opposite side: 7, Thickness: 2.4 (Nickel-plated brass) resistant,
(Free Cutting) Lens (PMMA) Oil-resistant
Washers (Nickel-plated iron)
2.2 dia. Bending
Heat-
Sensing surface 2.3 dia. resistant
10
15 2,000 Area
3.2 Detection
Liquid-
Applications
level
Reflective Fiber Units Vacuum
Specifications FPD,
Semi,
Type Sensing distance (mm) Optical axis Solar
Bending diameter
Sensing Aperture Appearance (mm) radius E3X-HD E3NX-FA (minimum Models
direction angle of cable sensing
GIGA HS Other modes GIGA HS Other modes object)
1,290
860 ST : 360 ST : 540
R25 E32-LD11 2M
23 250 SHS: 110 370 SHS: 110
Top-view 15°
(0.1 dia./
M6 1,260 0.03 dia.)
Flexible, 840 ST : 350 ST : 520
E32-LD11R 2M
R1
240 SHS: 100 360 SHS: 100
IP50
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for Reflective Fiber Units are for glossy white paper.
Point
S mart Fiber
Standard
Wire-saving
E3X-HD6 E3X-HD8
connector
Wire-saving Connectors
(Order Separately) (An Amplipier Unit with a wire-saving connector is required.)
Straight XS3F-M421-402-A
2m 4
Right-angle XS3F-M422-402-A