Two-Phase
Immersion Cooling
A revolution in data center efficiency
3M immersion coolants, Boards designed for 2PIC without There are many benchmarks that can
a brief history bulky heat sinks and cold plates can be used to measure the growth of this
be densely packed with processing rapidly evolving industry, such as the
3M has a long-held leadership position
hardware, creating a new path to number of new merchants accepting
in immersion cooling. In the 1950s,
previously unattainable performance the cryptocurrency or the transaction
3M introduced its first dielectric
capabilities with improved volume across the network. The most
fluorochemical heat transfer fluids
overclocking capacity – 500W ASICs impressive metric by far, however,
for direct contact cooling for military
have been successfully overclocked to is the astronomical increase in the
avionics. The 1970s and 1980s brought
well over 750W. processing power of the network of
an era of direct contact cooling which
computers involved in
helped enable the development of
processing blockchain
dense radar, power electronic and
transactions and
supercomputer systems. Vapor condenses on
How two phase coil or lid condenser creating new bitcoins.
In 1996, 3M™ Novec™ Engineered immersion The ability to create
Fluids – a new class of sustainable
cooling works Fluid recirculates
densely packed
chemistries – were introduced as passively
to bath circuit boards
replacements for ozone-depleting
paired with high-
substances, such as CFCs and Vapor rises
performance during
greenhouse gases such as HFCs. to top
overclocking made
Novec fluids have a host of
2PIC a natural fit for
characteristics that set them apart. Heat generated
on chip and blockchain transaction
They’re non-conductive, non-ozone
fluid turns processing, an
depleting and nonflammable with a
into vapor industry with a need
low toxicity and low global warming
for processing power
potential.
that is growing at
Over the past five years, 3M engineered unprecedented
fluids have been used in server rates. This growth
cooling in a series of technology and progression
demonstrations, which have been The fast-paced world of blockchain can provide a roadmap for high
recognized by the industry for best performance computing as it evolves
Bitcoin, a cryptocurrency and
in class energy efficiency. toward and beyond exascale.
consensus network, enables a new
2PIC with a 3M™ Novec™ payment system and is the first Considering the total value of 2PIC
Engineered Fluid decentralized peer-to-peer payment
For BitFury and Allied Control, building
2PIC involves placing hardware in network that is powered by its users.
a 2PIC system with 3M™ Novec™
an accessible tank of dielectric fluid Bitcoin blockchain began as open-
Engineered Fluid offered a key feature
coolant with a low boiling point, e.g., source software in 2009. At that time,
that set it apart – scalability. The ability
3M™ Novec™ 7100 Engineered Fluid hobbyists could use desktop PCs with
to accommodate rapidly evolving
boils at 61°C (142°F). As the hardware conventional CPUs to perform the
blockchain transaction processing
heats up in the tank, it boils the Novec hashing required to verify transactions
hardware without the costs of
fluid, and this change in state pulls the and publish them to the public
integrating a new thermal management
heat away from the components. blockchain. Soon, Bitcoin enthusiasts
solution for each generation created
realized that GPUs were faster and
The Novec fluid becomes a vapor, more long-term value.
more efficient. As the breakeven
rises, condenses on a water-cooled processing efficiency for blockchain “With 250 kW per rack and not having
condenser coil and falls back into the processing increased, GPUs gave way reached the limits yet, we now have the
tank without the use of pumps. The to FPGA and then evolved to low- ability to grow quickly and spread the
streamlined system can deliver as end ASIC chips. At present, leading cost of the cooling system over many
much as 95 percent cooling energy industry technologies comprise hardware generations,” said Kar-Wing
savings with minimal fluid loss. multi-megawatt arrays with purpose- Lau, vice president of operations at
built ASICs. 1 Allied Control.
Two-Phase Immersion Cooling: A revolution in data center efficiency
Allied Control designed BitFury’s setup us to many different technological help organizations with more powerful
in a matter of months, and at present, innovations. These experiences and hardware configurations lead in a
the ground-up build is in progress. technologies could be useful for next future where compute power is its own
The target is to have 40MW up and generation data center constructions evolving form of currency. <
running at 1.02 PUE within October of high performance computing and
2015 and scale up to more in near supercomputing.”
future. This commitment underlines
the expectation to create significant
energy and cost savings in a very short
amount of time. Advantages of 2PIC over
In terms of power density per square conventional air cooling
foot, the space required to house Increased More computing Dramatically
BitFury’s system is phenomenally power density power in less energy
per rack less space used for cooling
small – as much as ten times smaller
Up to
than traditional air cooling. The system
avoids additional costs associated with Air 4 - 40 10 1.1 - 2.0
kW pPUE
kW per m 2
traditional chillers relying instead on
dry coolers that efficiently manage the 3M Up to Up to
load at ambient temperatures of 40°C Novec
250 100 1.02
Fluid pPUE
and enable waste heat capture. kW kW per m2
The 3M™ Novec™ Brand Family The Novec brand is the hallmark for a variety of proprietary 3M products. Although each has its own
unique formula and performance properties, all Novec products are designed in common to address
the need for safe, effective, sustainable solutions in industry-specific applications. These include
precision and electronics cleaning, heat transfer, fire protection, protective coatings, immersion cooling,
advanced insulation media replacement solutions and several specialty chemical applications.
3M™ Novec™ Engineered Fluids 3M™ Novec™ Aerosol Cleaners 3M™ Novec™ 1230 Fire Protection Fluid 3M™ Novec™ Electronic Grade Coatings 3M™ Novec™ Electronic Surfactants 3M™ Novec™ Dielectric Fluids
■ ■ ■ ■ ■
Regulatory: For regulatory information about this product, contact your 3M representative.
Technical Information: The technical information, recommendations and other statements contained in this document are based upon tests or experience
that 3M believes are reliable, but the accuracy or completeness of such information is not guaranteed.
Product Use: Many factors beyond 3M’s control and uniquely within user’s knowledge and control can affect the use and performance of a 3M product in
a particular application. Given the variety of factors that can affect the use and performance of a 3M product, user is solely responsible for evaluating the 3M
product and determining whether it is fit for a particular purpose and suitable for user’s method of application.
Warranty, Limited Remedy, and Disclaimer: Unless an additional warranty is specifically stated on the applicable 3M product packaging or
product literature, 3M warrants that each 3M product meets the applicable 3M product specification at the time 3M ships the product. 3M MAKES NO
OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF
DEALING, CUSTOM OR USAGE OF TRADE. If the 3M product does not conform to this warranty, then the sole and exclusive remedy is, at 3M’s option,
replacement of the 3M product or refund of the purchase price.
Limitation of Liability: Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether direct, indirect,
special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability.