Professional Documents
Culture Documents
Elastimold ®
Compelling value
Design principles
Product overview
Switchgear applications
Control types
Appendix
Options and accessories
September 27,
Slide 2
2018
Elastimold solid dielectric switchgear — agenda
Compelling value
Design principles
Product overview
Switchgear applications
Control types
Appendix
Options and accessories
September 27,
Slide 3
2018
Compelling value
Summary
– Safe
– Reliable
– Flexible
– Compatible
– Environmentally friendly
– Lifecycle cost reducing
September 27,
Slide 4
2018
Compelling value
Safe — dead-front construction eliminates
exposure to live components
– Proprietary diaphragm provides
electrical isolation
– Not dependent on oil, gases or air for
proper isolation from high voltage
September 27,
Slide 5
2018
Compelling value
Reliable — maintenance-free vacuum
and EPDM molded insulation
– Proven solid dielectric construction
– Technology with over 50 years
of field-proven performance
– Fewer outages and significantly shorter
outage duration
– All switchgear components are sealed
and fully submersible
September 27,
Slide 6
2018
Compelling value
Flexible — compact and lightweight design
September 27,
Slide 7
2018
Compelling value
Flexible — modular MVS/MVI units allow for an unlimited number of ways and configurations
September 27,
Slide 8
2018
Compelling value
Flexible — retrofit your SF6 switchgear with modular three-way installation
September 27,
Slide 9
2018
Compelling value
Compatible — works with the industry-leading
protection and automation controls
SEL® 751A series SEL® 451 SEL® 451 series
September 27,
Slide 10
2018
Compelling value
Environmentally friendly — for a safe, cost-effective
and sustainable grid
– No oils or gases to monitor, maintain or dispose
– EPDM rubber is a green solution
– Emits no greenhouse gases, unlike SF6
September 27,
Slide 11
2018
Compelling value
Lifecycle cost reducing — no oil or SF6 gas
September 27,
Slide 12
2018
Elastimold solid dielectric switchgear — agenda
Compelling value
Design principles
Product overview
Switchgear applications
Control types
Appendix
Options and accessories
September 27,
Slide 13
2018
Design principles
Common interrupting and insulation mediums
September 27,
Slide 14
2018
Design principles
Common interrupting and insulation mediums
Oil 3
SF6 gas 3
EPDM
0.5
rubber
Vacuum 0.5
0 2 4 6 8 10 12 Dielectric in inches
September 27,
Slide 15
2018
Design principles
Benefits of solid dielectric and vacuum interruption
– Smaller footprints
– No sensitivity to environment and contaminates
– Maintenance-free*
– Lower risk of failure
– Lower risk of fire
– Lower costs for maintenance staff and switching
– Shorter outages to repair/replace
September 27,
Slide 16
2018
Elastimold solid dielectric switchgear — agenda
Compelling value
Design principles
Product overview
Switchgear applications
Control types
Appendix
Options and accessories
September 27,
Slide 17
2018
Product overview
Elastimold solid dielectric switchgear
– System voltage ratings Molded vacuum switches (MVS) Molded vacuum interrupters (MVI)
from 15 kV through 38 kV
– Standard current ratings of
600 A continuous and up to
25 kA interrupting (interrupters)
and 40 kA momentary (switches)
– Three-phase and single-phase
base designs
September 27,
Slide 18
2018
Product overview
Molded vacuum switch (MVS) — cutaway
Operating
handle
September 27,
Slide 19
2018
Product overview
MVS ratings
Application information
Construction: Submersible, corrosion resistant, fully shielded
Operating temperature range: -40 °C to 65 °C
September 27,
Slide 20
2018
Product overview
Molded vacuum interrupter (MVI) — cutaway
Patented silicone
rubber diaphragm
separates line and
ground potential
September 27,
Slide 21
2018
Product overview
MVI ratings
Application information
Meets ANSI C37.60 requirements
Operating temperature range: -40 °C to 65 °C
September 27,
Slide 22
2018
Product overview
Wide range of fault current ratings
12.5 kA 16 kA 20 kA 25 kA 40 kA
MVS — 3-phase
15 kV X X X
27 kV X X X
38 kV X
MVI — 3-phase
15 kV X X X
27 kV X
38 kV X X
September 27,
Slide 23
2018
Elastimold solid dielectric switchgear — agenda
Compelling value
Design principles
Product overview
Switchgear applications
Control types
Appendix
Options and accessories
September 27,
Slide 24
2018
Applications
Typical switchgear applications
September 27,
Slide 25
2018
Applications
Padmount — multi-way unit construction/bus system
September 27,
Slide 26
2018
Applications
Padmount — multi-way unit construction
Multi-way
bus system
September 27,
Slide 27
2018
Applications
Padmount — multi-way unit construction
Two three-phase
MVS switches
September 27,
Slide 28
2018
Applications
Padmount — multi-way unit construction
Three single-phase
MVI interrupters
September 27,
Slide 29
2018
Applications
Padmount — multi-way unit construction
Three single-phase
MCAN fuse canisters
September 27,
Slide 30
2018
Applications
Padmount — multi-way unit construction
September 27,
Slide 31
2018
Applications
Modular
September 27,
Slide 32
2018
Applications
Modular — up to 35 kV-rated load-break switches
and fault interrupters
Molded vacuum interrupter (MVI) Molded vacuum switch (MVS) Bus bar connection
September 27,
Slide 33
2018
Applications
Modular — unlimited number of ways and configurations
September 27,
Slide 34
2018
Applications
Small vault
September 27,
Slide 35
2018
Applications
Small vault
September 27,
Slide 36
2018
Applications
Small vault — compact size
– 2, 3, 4, 5 and 6 ways
– 15 kV, 27 kV
– 12.5 kA
– Same BIL ratings
– Same withstand ratings for MVI/MVS
– 3-phase MVS and MVI only
– Manual or motor operated
– 200 A, 600 A bushings
– Elastimold 80, ATS, motor submersible
and 80 submersible
– SEL 451A, 751A and 751A-submersible
September 27,
Slide 37
2018
Applications
Small vault — compact size
September 27,
Slide 38
2018
Elastimold solid dielectric switchgear — agenda
Compelling value
Design principles
Product overview
Switchgear applications
Control types
Appendix
Options and accessories
September 27,
Slide 39
2018
Controls
Protection and automation controls
September 27,
Slide 40
2018
Controls
Elastimold self-powered controls for fault interrupting devices
Programmable single-/
Three-phase only Internal three-phase trip SCADA option
September 27,
Slide 41
2018
Controls
SEL automation controls
September 27,
Slide 42
2018
Elastimold solid dielectric switchgear
Compelling value summary
– Safe
– Reliable
– Flexible
– Compatible
– Environmentally friendly
– Lifecycle cost reducing
September 27,
Slide 43
2018
Elastimold solid dielectric switchgear — agenda
Compelling value
Design principles
Product overview
Switchgear applications
Control types
Appendix
Options and accessories
September 27,
Slide 44
2018
Appendix — options and accessories
Motor control system/motor installation
Top pin
Hole in tab
Large hairpin clip
Hole in top plate
Pin
Motor box
September 27,
Slide 45
2018
Appendix — options and accessories
Voltage sensor components
September 27,
Slide 46
2018
Appendix — options and accessories
Voltage sensor components
September 27,
Slide 47
2018
Appendix — options and accessories
Solid dielectric deadfront control power transformer
Transformer ratings:
– 15 kV class
• 2400/120 V
• 7000–7620/116–127 V
– 25 kV class
• 13,200–14,400/115–125 V
– 38 kV class
• 19,000–20,750/115–125 V
September 27,
Slide 48
2018
Appendix — options and accessories
Submersible control box panel views
Notes:
– Standard provisions allow
connection for up to six ways
– Fiber and Ethernet interface
connectors available
September 27,
Slide 49
2018
Appendix — options and accessories
Submersible control box panel views
September 27,
Slide 50
2018
Appendix — options and accessories
600 amp deadbreak cam-op
Link
September 27,
Slide 51
2018
Appendix — options and accessories
Cam-op elbow-to-equipment bushing assembly application
Equipment
tank Insulating
plug
Elbow
Insulated cap
(DRG)
September 27,
Slide 52
2018
Appendix — options and accessories
Cam-op elbow-to-equipment bushing assembly application
Equipment
tank
De-energize system
September 27,
Slide 53
2018
Appendix — options and accessories
Cam-op elbow-to-equipment bushing assembly application
Equipment
tank
Install Visi-Break
September 27,
Slide 54
2018
Appendix — options and accessories
Cam-op elbow-to-equipment bushing assembly application
Equipment
tank
September 27,
Slide 55
2018
Appendix — options and accessories
Cam-op elbow-to-equipment bushing assembly application
September 27,
Slide 56
2018
Appendix — options and accessories
Position indicator design criteria
Viewing window
Visible open
indicator
Vacuum
bottle
September 27,
Slide 57
2018
Appendix — options and accessories
Position indicator/viewing window open
September 27,
Slide 58
2018
Appendix — options and accessories
Position indicator/viewing window close
September 27,
Slide 59
2018