HEAT LOAD CALCULATION FOR RESIDENTIAL HOMES

Sl. No. Load Description Survey Data


Floor Area BTU
1
a. Floor area (in sq. m) 16.00

Windows BTU
Total area of all north facing windows (with or
a. without shadings to be included) 2.60

Total area of windows (without shadings only or


b. 2.60
2 direct sunlight)
Total area of all south facing windows (with or
c. 0.00
without shadings to be included)
Total area of windows (without shadings only or
d. 0.00
direct sunlight)

Occupants BTU
3
a. No. of occupants 2.00

Equipment BTU
4 Total equipment wattage (include all electrical
a. appliances and equipments such as TV, DVD player, 160.00
computer, laptop, fan, iron, etc.)

Kitchen Load
5 If have a kitchen in the area, just enter or type 1 in
a. 0.00
the survey data

Lighting BTU
6
a. Total lighting wattage 100.00

BTU REQUIRED
Total BTU required 7850.76
7 AC size required (TON) 0.65
Estimated AC size required in TON 0.75
Estimated AC size converted to HP 1.0

BTU REQUIRED WITH 20% ALLOWANCE (OPTIONAL)


Additional BTU allowance at 20% 1570.15
Total BTU required 9420.91
8
AC size required (TON) 0.79
Estimated AC size required in TON 1.0
Estimated AC size converted to HP 1.5
SL. NO. HP TR BTU/HR KJ/HR LRA
1 0.75 0.5 8150 8600 15.0A
2 1 0.75 9000 9495 20.0A
3 1.5 1 12000 12660 33.0A
4 2 1.5 18000 18990 52.0A
5 2.5 2 24000 25320 62.0A
6 3 2.5 30000 31650 82.0A
7 4 3 36000 37980 105.0A
8 5 4 48000 50640 123.0A
9 6 5 60000 63300 141.0A
10 12 10 120000 126600 239.0A