Professional Documents
Culture Documents
08 Multisensor
08 Multisensor
3
System Components
• Downhole Tool
• Brings all transducer measurements to a single point.
– Communicates sequentially the measurements to
surface.
– Connects to power cable via motor
• Downhole Communication
– This is the ESP motor cable to the surface
System Components
• Surface Choke
– Separates the DC signal from the high voltage AC
– Isolates system in event of fault
• Surface Panel
– Monitors the signal on the HV cable
– Calculates the measurement using calibration figures
– Outputs data in customer format
– Provides Power for downhole tool
MDT System
VSD
ISP
? Adc
cable
5000 psi
motor
15 psi
10 mA 18 mA
MDT
Multisensor
The Multisensor measures:
• Intake Pressure
• Discharge Pressure (optional)
• Intake temperature
• Motor temperature
• Flowrate (optional)
• ESP Vibration
• Cable Insulation
Downhole System
• Downhole sensors are calibrated to international
standards
• Data is transmitted via the motor power cable to the
surface
• The downhole electronics are proven for their
operation in this environment.
• Operational limits 125C and 5600PSI (10000 PSI in
high pressure version)
Integrated Surface Panel (ISP)
The ISP provides:
• The power for the Multisensor
• Signal decoding for the Multisensor
• Data display and storage
• ESP protection though Alarm
and Trip functions
• An interface to customers SCADA
units
Choke Console
• The choke provides high
voltage isolation between the
high voltage of the ESP
system and the ISP
• The Choke can be supplied
either with or without an
enclosure
MultiSensor
Parameter Type 0 Type 1 Type 2
Intake Pressure X X X
Discharge Pressure X X
Intake Temp X X X
Motor Temp X X X
Flow X
Vibration X X X
MultiSensor
Motor Temp Connection
Motor Connection
Flowmeter Port
Discharge Pressure Port Intake Pressure Port
Intake Temperature
Vibration Sensor
• Turbine
Cz Pi Tm Vi
Ti
+120 Vdc
0 Vdc
Calibration Key
• The calibration data is stored in
the Calibration Key
• The calibration key contains the
calibration information specific
to that tool.
• The key is located in the ISP
panel.
• This key is programmed at
manufacture additional keys
can be ordered if required.