You are on page 1of 3

BIOLOGICAL SAFETY CABINET CLASS II A2‐X

Models BSC‐N 1100 / 1300 / 1500 / 1800

CHARACTERISTICS
• CLASS II Biological safety cabinet, according to
EN 12469 standard.
• Work area and work surface made of stainless
steel AISI 304. The work surface has a well for easy
cleaning and collection of liquids with a capacity
no less than 4000 ml and one drain valve collecting
under collecting tank and it is convenient for
cleanliness.
• Front panel of multi‐layer doubling toughened
glass.
• Recycled air is filtered through an absolute HEPA
H14 filter (99.995% MPPS efficiency EN 1822
Standard) and is sent to the work area at a speed
of 0.45 m/s + 0.1.
• Partial re‐circulation of air according to
regulations: 30% exhaust and 70% re‐circulation.
Exhausted air is filtered by a separate absolute
HEPA H14 filter (99.995% efficiency MPPS EN 1822 illumination, internal electricity connection, gas
Standard), especially for such purpose. valve and parameters.
• Automatic electronic system regulating motor
• Work area maintains laminar flow conditions speed to adapt to progressive filter saturation and
with ISO 4 type air purity (according to ISO 14644) protection conditions.
or Class 10 (according to Fed. Std. 209). • Alarms for detecting problems in the impulsion
• Protection barrier in the work area with a speed system and the negative pressure protection
greater than 0.6 m/s. barrier and opening of doors.
• Illumination may be fluorescent or ultraviolet.
• Cabinet controlled by microprocessor with
• Working voltage 220 V. 50 Hz. Maximum
updateable FLASH memory and double display:
electricity consumption 6A (approx. 1300 w.).
one external and the other internal (work area) for
• The cabinet includes U.V. light as a standard
easy visualisation of the cabinet control
feature; 220 volt electricity connection.
parameters (speeds, flows, plenum pressure,
Optional accessories:
expulsion barriers, etc…)
• Gas connection with electronically controlled
• The cabinet has an easy to use tactile panel with valve.
a security key for control of white / ultraviolet • Vacuum connection.

HEADQUARTERS DELEGATIONS
José Echegaray, 8 Local 1‐3
28100 – Alcobendas – Madrid ‐ Spain Catalunya.   Tel. +34 676 351 264
Tel. +34 902 103 578    Fax.+34 902 102 459 Galicia.         Tel. +34 639 486 955
www.tdi.es ventas@tdi.es Andalucía.    Tel. +34 639 481 756
BIOLOGICAL SAFETY CABINET CLASS II A2‐X
Models BSC‐N 1100/1300/1500/1800/2000

ADVANTAGES 425‐BSC‐N‐XXXXA2‐XN

 BSC class II according to EN 12469‐2000 and also meets the main requirements of NSF 49 
(class II type A2/B3) and BS 5726:2005.

 LCD display. The functions visible on the screen (laminar, barriers, temperature, humidity, 
clogging of the filter, etc...)

 Remote control. All functions of the cabin can be controlled six meters away, and thus to 
protect the user in case of emergency.

 Ergonomically tested, thanks to the noise level that is less than 58 dBA, below the level 
required by the regulations 65 dBA.

 Broad and curved armrests that provides comfort on the forearm in any working position.

 Monitoring and adjustment of the clogging of the filters minimizing the cost of replacing 
these.

OFICINA PRINCIPAL DELEGACIONES
José Echegaray, 8 Local 1‐3
28100 – Alcobendas – Madrid ‐ Spain Catalunya.   Tel. +34 676 351 264
Tel. +34 902 103 578    Fax.+34 902 102 459 Galicia.         Tel. +34 639 486 955
www.tdi.es ventas@tdi.es Andalucía.    Tel. +34 639 481 756
BIOLOGICAL SAFETY CABINET CLASS II A2‐X
Models BSC‐N 1100/1300/1500/1800/2000

TECHNICAL SPECIFICATIONS
MODEL BSC‐N‐1100IIA2‐X BSC‐N‐1300IIA2‐X BSC‐N‐1500IIA2‐X BSC‐N‐1800IIA2‐X BSC‐N‐2000IIA2‐X
Working Area 940 x 600 x 660 1100 x 600 x 660 1300 x700 x630 1710 x 600 x 660 1800 x 600 x 660
Dimention extenal (mm)  1100 x 750 x 2250 1300 x 850 x 2200 1500 x 840 x 2280 1870 x 750 x 2290 1950 x 800 x 2300
Dimenstion for transpor(mm) 1250 x 1050 x 1870 1450 x 1050 x 1870 1640 x 1040 x 1860 1940 x 1050 x 1960 2090 x 1050 x 1860
Weight (kg) 255 305 350 390 420
Material Zona de trabajo y superficie de trabajo construida en acero inoxidable AISI 304
Sistema de control Microprocesador con memoria Flash
Display VFD display
Filter (Main) Filtro absoluto Hepa H14 con una eficacia del 99,995% mpps según normativa EN 1822
Filter exhaust Filtro absoluto Hepa H14 con una eficacia del 99,995% mpps según normativa EN 1822
Barrier 0,53 m/s
Flaminar Flow 0,33 m/s
Air Renovations 70%
Out Flow 30%
Cristal frontal Deslizamiento electrónico automático (Cristal templado de seguridad)
Clasificación de pureza de aire Clase 10
Sound Level ≤ 65 db
Iluminación ≥ 1000 lux
Lamp ultravioleta 1 X 18 W 1 X 18 W 1 X 30 W 1 X 40 W 1 X 40 W
Recogida de residuos ≥ 4000 ml con valvula para evacuación
Power 220 v, 50 h z± 10%
Norms NSF 49, EN 12469
Consumo 700 W 1060 W 1300 W 1350 W 1700 W

REFERENCIAS PARA PEDIDOS
Código Descripción
425‐BSC‐N‐1100IIA2‐X Biological Safety Cabinet Tipo II C10 Mod. BSC‐N‐1100IIA2‐X (70 ‐ 30 %)
425‐BSC‐N‐1300IIA2‐X Biological Safety Cabinet Tipo II C10 Mod. BSC‐N‐1300IIA2‐X (70 ‐ 30 %)
425‐BSC‐N‐1500IIA2‐X Biological Safety Cabinet Tipo II C10 Mod. BSC‐N‐1500IIA2‐X (70 ‐ 30 %)
425‐BSC‐N‐1800IIA2‐X Biological Safety Cabinet Tipo II C10 Mod. BSC‐N‐1800IIA2‐X (70 ‐ 30 %)
425‐BSC‐N‐2000IIA2‐X Biological Safety Cabinet Tipo II C10 Mod. BSC‐N‐1800IIA2‐X (70 ‐ 30 %)

MAIN OFFICE DELEGATIONS
José Echegaray, 8 Local 1‐3
28100 – Alcobendas – Madrid ‐ Spain Catalunya.   Tel. +34 676 351 264
Tel. +34 902 103 578    Fax.+34 902 102 459 Galicia.         Tel. +34 639 486 955
www.tdi.es ventas@tdi.es Andalucía.    Tel. +34 639 481 756

You might also like