You are on page 1of 48

无锡东舟船舶附件有限公司

N OT E: K EE P CL OS ED I N SE A!
航行 时保持关闭!
无锡东舟船舶附件有限公司
NOTE: KEEP CLOSED AT SEA!
无锡东舟船舶附件有限公司
NOTE: KEEP CLOSED AT SEA!
1

3
开 关
福建马尾MW619平台供应船
MW619 Platform supply vessels

other side of door

至AMS
TO AMS
1WCB9,2x1
门另一侧

1AF3
1PB1

液压滑动水密门
HYDRAULIC WATERTIGHT DOOR

hydraulic sliding watertight doors

1WCB1,7x1.5 1WCB7,5x1.5
液压水密门系统

1PB2 1PB3
one side of door

1WCB
门一侧

来自充放电板
1WCB2,7x1.5 FROM CHP
DC24V 2×2.5

1WCB3,3x1.5 1WCB8,2x2.5

1WCB4,3x1.5 2x2x0.75 CHJPJ86/NC


1AF2

双绞屏蔽线
1WCB5,3x1.5 shielded twisted pair cable
1WLK2 1WLK1

1WCB6,3x1.5

来自应急配电板
FROM ESB
AC690V 3×1.5
1WST1,2×1
* * *

1PS2
hydraulic pump unit

1WST

1PS1 1WST2,2×1
液压泵站

1WST3,2×1
SYSTEM DIAGRAM

1LK
系统图

1WST4,2(2×1.5)
*

1DDV
1WST5,3×1.5
*

1M

1WST6,2×1
*

1PS3

WDIC
other side of door

TO AMS
WUXI DONGZHOU MARINE FITTINGS CO,.LTD

2WCB9,2x1
门另一侧

2AF3
无锡市东舟船舶附件有限公司

2PB1

液压滑动水密门
hydraulic sliding watertight doors

2WCB1,7x1.5 2WCB7,5x1.5
2PB2 2PB3
one side of door

2WCB

来自充放电板
门一侧

FROM CHP
2WCB2,7x1.5 DC24V 2×2.5

2WCB8,2x2.5
2WCB3,3x1.5
2x2x0.75 CHJPJ86/NC
2WCB4,3x1.5
2AF2

双绞屏蔽线
shielded twisted pair cable

2WCB5,3x1.5 2x2x0.75 CHJPJ86/NC


2WLK2 2WLK1
双绞屏蔽线
shielded twisted pair cable
2WCB6,3x1.5

来自应急配电板
FROM ESB
DRWG NO.

AC690V 3×1.5
图号

2WST1,2×1
* * *

2PS2
hydraulic pump unit

2WST

2PS1 2WST2,2×1
液压泵站

2WST3,2×1
2LK
2WST4,2(2×1.5)
*

2DDV
2WST5,3×1.5
*

2M

2WST6,2×1
*
WUXI DONGZHOU MARINE FITTINGS CO,.LTD

2PS3
无锡东舟船舶附件有限公司

COFFERDAM DECK
驾驶甲板
UPPER DECK
上甲板
SBK-XT

To the next page


至下一页
1-01
PAGE
页数
WHC 2x2x0.75 CHJPJ86/NC
TO VDR
双绞屏蔽线
shielded twisted pair cable
WDIC
驾驶甲板
COFFERDAM DECK
3PB3

上甲板
UPPER DECK
接上一页
Continued from previous page
shielded twisted pair cable

shielded twisted pair cable


2x2x0.75 CHJPJ86/NC

2x2x0.75 CHJPJ86/NC
DC24V 2×2.5

AC690V 3×1.5
3WCB7,5x1.5

3WCB8,2x2.5

来自应急配电板
来自充放电板
3WCB9,2x1

FROM ESB
FROM CHP
TO AMS

双绞屏蔽线

双绞屏蔽线
3WCB 3WST
hydraulic sliding watertight doors

*
*

3WST4,2(2×1.5)
* * * *

3WST5,3×1.5
3WCB1,7x1.5

3WCB2,7x1.5

3WCB3,3x1.5

3WCB4,3x1.5

3WCB5,3x1.5

3WCB6,3x1.5

3WST1,2×1

3WST2,2×1
3WST3,2×1

3WST6,2×1
液压滑动水密门

1PS2
1PS1

1PS3
1LK
1DDV
1WLK1

1M
1AF3 1AF2 液压泵站
hydraulic pump unit

1WLK2
1PB2
1PB1
门另一侧 门一侧
other side of door one side of door
图号 SBK-XT 页数
福建马尾MW619平台供应船 液压水密门系统 系统图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels HYDRAULIC WATERTIGHT DOOR SYSTEM DIAGRAM 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
1-02
14
上甲板指示盒 舱壁甲板以上,防护等级IP56。
13 1-3PB3 Instructions box on the upper deck
3 ANH-2 Above the bulkhead deck
12 1-3AF2-3 警笛
6 JHDG-1Z 安装在水密门二侧,防护等级IP56。
Siren W.T. doors installed in the door frame
11 1-3WLK1-2 限位开关
6 安装在水密门门框上,防护等级IP68。
Limit switch W.T. doors installed in the door frame
电磁阀 安装在电动液压泵组 IP67
10 1-3DDV Solenoid valve 3 Installed in the electric hydraulic pump group
电机 安装在电动液压泵组 IP67
9 1-3M motor 3 Installed in the electric hydraulic pump group
液位开关 安装在电动液压泵组 IP67
8 1-3LK Level Switch 3 Installed in the electric hydraulic pump group
1-3PS3 蓄能器压力开关(低压报警) 安装在电动液压泵组 IP67
7 Hydraulic oil pressure switch ( low ) 3 Installed in the electric hydraulic pump group
压力开关(高,低控制) 安装在电动液压泵组 IP67
6 1-3PS1-2 pressure switch (High 、 low control)
6 Installed in the electric hydraulic pump group
1-3PB1-2 操作指示盒 ANH-3 安装在水密门二侧,防护等级IP68
5 Operation&Indication box 6 W.T. doors installed in the door frame
1-3WCB 水密门控制箱(报警指示部分)
4 W.T.Control Box-Alarm Section 3 安装在水密门旁 IP68
BJ-1
Installed in the watertight door
1-3WST 水密门控制箱(控制部分)
3 W.T.Control Box-Control Section 3
WDIC 驾驶室遥控面板 YK-1 built in type 安装在驾驶室遥控台上 IP22
2 remote display panel 1 Installed in the cab remote table
1 WHC 驾驶台 1
No. Code Name Qty Type Remark
图号 SBK-XT 页数
福建马尾MW619平台供应船 液压水密门系统 系统图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels HYDRAULIC WATERTIGHT DOOR SYSTEM DIAGRAM 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
1-03
Note:
1.External cables used CJPJ85/NC type
2.alarm box and control box made made of one , cut off the middle box ,
so two connections in the inner join the cabinet .
3.with * Cable with ancillary equipment connected.
4.the remote control panel all the way to the VDR RS485 interface (power
fualt、low oil-level、low oil-pressure、moter overload)
5. all the way to each alarm control box integrated alarm ( contact )
interface to the engine room alarm system
6.the main electrical control box alarm Schneider Electric
说明:
1、外部电缆选用CJPJ85/NC型
2、报警箱和控制箱做成一体,箱体中间隔断,这样两箱体的连线在内部联接。
3、带*电缆随设备配套接好。
4、驾驶室遥控面板一路RS485接口到VDR(失电、低油位、低油压、过载)。
5、每个报警控制箱各一路综合报警(触点)接口到机舱报警系统
6、报警控制箱主要电气采用施耐德电气
图号 SBK-XT 页数
福建马尾MW619平台供应船 液压水密门系统 系统图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels HYDRAULIC WATERTIGHT DOOR SYSTEM DIAGRAM 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
1-04
*190
310
150
水 密 门 遥 控 板
W.T. SLIDE DOOR CONTROL PANEL
东 舟
R
No.1 DOOR

蜂鸣器 调光
BUZZER DIMMER
R G
No.2 DOOR

No.3 DOOR

G
G R
消音 试灯
SILENCER LAMP TEST

210
Fr.30 Fr.96 Fr.117 TANK TOP
单独关 就地 同时关
SINGLE LOCAL CENTRAL
CLOSE CONTROL CLOSE
电源
POWER
注意:
船航行时水密门
综合故障
GROUP FAULT
一 定要关闭!
NOTE:
THE WATERTIGHT DOOR
关门 SHOULD BE CLOSED
模式选择 CLOSE DOOR WHEN IN SAILING!
SELECT SWITCH
一号门 二号门 三号门
NO.1 DOOR NO.2 DOOR NO.3 DOOR
270
数量:1只/船
Note:
1、型号:YK-1;
model:YK-1;
2、驾控板开孔尺寸:270 X 210;
opening size on console panel:270 X 210;
3、面板材料:5mm 铝板,表面发黑;
face material:5 mm aluminium sheet,matt blake;
4、面板字体:黑体;
font:bold-face.
图号 SBK-YKB 页数
福建马尾MW619平台供应船 驾驶室遥控板 外形图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels W/H W.T.DOOR REMOTE BOARD OUTLINE DRAWING 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
2
1#CLOSE DOOR IND.
1#OPEN DOOR IND.
CENTRAL CLOSE

驾驶室遥控板
1#COMMON ALARM
1#综合报警
1#开门指示

1#电源指示
1#POWER IND.
1#关门指示
同时关
蜂鸣器
BUZZER
单独关
SINGLE

LOCAL
就地

W/H W.T.DOOR REMOTE


BOARD 91+
91-
90+ FU1/2A Z2+ Z2+
FU2/4A Z2- Z2-
91-
R2 80-
CPU1

单独关
同时关
PORT 1

就地
V1 PORT 0

RS-A2

RS-B2
RS-B
RS-A
来自控制箱
至VDR R1
To VDR
Z1+ from ctrl box

SB1

SB2

SB3

SB4
Z1-

SB5
SA1
DC24V power A1 A2 Z2- Z2+ 80-
R2

就地/遥控关

2# SINGLE CLOSE
1# SINGLE CLOSE

3# SINGLE CLOSE
2#单独关
1#单独关

3#单独关
1 2 3 4 5

SILENCE
local/remote close

试灯
消音

TEST
技术要求:
未注导线选用CBVR-0.5船用导线 。
Note:
Not specified cable to be cbvr-0.5.
图号 SBK-YKB-YL 页数
福建马尾MW619平台供应船 驾驶室遥控板 电器图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels W/H W.T.DOOR REMOTE BOARD CIRCUIT DIAGRAM 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
3-01
2#CLOSE DOOR IND.
2#OPEN DOOR IND.

2#COMMON ALARM
2#电源指示
2#POWER IND.
2#综合报警
2#关门指示
2#开门指示

91+ 91+
91- 91-
Z2+ Z2+
Z2- Z2-
80- 80-
CPU2
3#CLOSE DOOR IND.
3#OPEN DOOR IND.

3#COMMON ALARM
3#综合报警
3#关门指示

3#电源指示
3#POWER IND.
3#开门指示
图号 SBK-YKB-YL 页数
福建马尾MW619平台供应船 驾驶室遥控板 电器图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels W/H W.T.DOOR REMOTE BOARD CIRCUIT DIAGRAM 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
3-02
RX: Z1+ Z1- Z1+ Z1- Z1+ Z1- RS-A RS-B RS-A2RS-B2
1 2 3 4 5 6 7 8 9 10
1 2 1 2
1 2 1 2 1 2

With shielded twisted pai

With shielded twisted pai


from 3# W.T door ctrl box
来自3#水密门控制箱
From 1# W.T.Control Box

From 2# W.T.Control Box

From 3# W.T.Control Box

TO VDR
至VDR
来自1#水密门控制箱

来自2#水密门控制箱

来自3#水密门控制箱
2x2.5

2x2.5

2x2.5
1WCB8

2WCB8

3WCB8
图号 SBK-YKB-JXT 页数
福建马尾MW619平台供应船 驾驶室遥控板 外接线图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels W/H W.T.DOOR REMOTE BOARD EXTERNAL WIRING DIAGRAM 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
4
HL1-3 指示灯 LAMP ф8(Green)DC24V 3 kacon
HL6-17 指示灯 LAMP ф8(6Red,3Green,3White)DC24V 12 kacon
FM 蜂鸣器 BUZZER LAS1-AY-D/24V Changjiang
1
SB2-5 按钮 PUSH BUTTON LAS1-AY-11(Green) 4 Changjiang
SB1 按钮 PUSH BUTTON LAS1-AY-11(Red) 1 Changjiang
SA1 PUSH BUTTON ZB2BD3C+Z101C+E101C Schneider
旋钮 1
R1 22k
调光旋钮 1
V1 3510
硅整流桥 1
R2 调光板
CPU1 CPU224 DC/DC/DC UN 214-1AD23-OXB8 1 unimat
CPU2-4 EM222 DC24V 8出 UN 222-1HF22-OXA0 1 unimat
图号 SBK-YKB-JXT 页数
福建马尾MW619平台供应船 驾驶室遥控板 外接线图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels W/H W.T.DOOR REMOTE BOARD EXTERNAL WIRING DIAGRAM 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
4
POWER AC690V POWER DC24 V LOCAL CONTROL REMOTE CONTROL
POWER OFF MOTER OVERLOAD LOW OIL-LEVEL LOW OIL-PRESSURE
COMM. FAILURE BUZZER LAMP TEST BUZZER OUT
PUMP RUNNING AUTO STOP DOOR
MANUAL
MOTOR START AUTO CLOSE DOOR
MOTOR STOP POWER CUT OFF OPEN DOOR
说明
Note:
1、箱体材料:SUS304不锈钢
box material:SUS304 Stainless steel;
2、箱体颜色:RAL 7032
box colour:RAL 7032;
3、IP等级:IP68 填料函数量 PACKING BLOCK Q'TY
IP rating:IP68.
4、铭牌材料:铜质 PG29( 18- 21) PG21( 15- 18) PG16( 12- 15)
Nameplate material:Brass
5、铭牌字体:黑体,英文 1 6 17
Nameplate:boldface,English
6、重量:27公斤
Weight:27Kg
图号 SBK-KZX 页数
福建马尾MW619平台供应船 水密门控制箱 外形图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels W.T.DOOR CONTROL BOX OUTLINE DRAWING 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
5-01
POWER AC690V POWER DC24 V LOCAL CONTROL REMOTE CONTROL
POWER OFF MOTER OVERLOAD LOW OIL-LEVEL LOW OIL-PRESSURE
COMM. FAILURE BUZZER LAMP TEST BUZZER OUT
PUMP RUNNING AUTO STOP DOOR
MANUAL
MOTOR START AUTO CLOSE DOOR
MOTOR STOP POWER CUT OFF OPEN DOOR
说明
Note:
1、箱体材料:SUS304不锈钢
box material:SUS304 Stainless steel;
2、箱体颜色:RAL 7032
box colour:RAL 7032;
3、IP等级:IP68 填料函数量 PACKING BLOCK Q'TY
IP rating:IP68.
4、铭牌材料:铜质 PG29( 18- 21) PG21( 15- 18) PG16( 12- 15)
Nameplate material:Brass
5、铭牌字体:黑体,英文 1 6 17
Nameplate:boldface,English
6、重量:27公斤
Weight:27Kg
图号 SBK-KZX 页数
福建马尾MW619平台供应船 水密门控制箱 外形图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels W.T.DOOR CONTROL BOX OUTLINE DRAWING 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
5-02
水密门控制箱-控制部分
W.T.Control Box-Control Section
FU1-1
L6 1
L4
L5 HL1
T1
FU1-2 690V/220V FU8 Z1+
K1
FU4 V1 Z2+ To the
6 8

AC220V
2 next page
FU5 下一页
3 7 Z1- Z1-

DC24V
V1
FU2 FU3
9
HL2
10 18
SB0
1HL4
K2
启动 泵运行
选择按钮 start 停止
Select Button pump running

FU9
SB5 stop
SA1 手动 SB6
manual 12 13 16
11 KM
KM-1
K3 自动 V2
auto.
15 KM-2
14
QF MX PS1 PS2
RJ
1.6-2.5A 10 17 1HL3
自动
auto.

FU7
FU6
L1 L2 L3 U V W
AC690V power
DC24V power
From ESB
From CHP
1.5KW,3φ,motor
图号 SBK-KZX-YL 页数
福建马尾MW619平台供应船 水密门控制箱 电器图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels W.T.DOOR CONTROL BOX CIRCUIT DIAGRAM 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
6-01
福建马尾MW619平台供应船
MW619 Platform supply vessels

Z1-

Z2+
K3
低油位 WZ1

CPU1
LOW OIL LEVEL

低油压报警 PS1
LOW PRESSURE ALARM 低油位报警
LOW OIL-LEVEL
W.T.DOOR CONTROL BOX

过载 RJ
OVERLOAD 低油压报警
LOW OIL-PRESSURE
水密门控制箱

交流电源 K1 过载报警
AC POWER
MOTER OVERLOAD
直流电源 K2
DC POWER 失电报警
POWER
开门到位 WX1
open the door in place
通讯故障
WX2 COMM. FAILURE
关门到位
close the door in place

就地
LOCAL CONTROL
开门钮 SB1
DOOR OPEN BUTTON 遥控
REMOTE CONTROL
关门钮 SB2 开门指示
CIRCUIT DIAGRAM

DOOR CLOSE BUTTON


1#DOOR OPEN
电器图

门停钮 SB3 关门指示


DOOR STOP BUTTON 1#DOOR CLOSE
试灯 SB7
LAMP TEST

消音 SB8
PORT 0

BUZZER OUT
WUXI DONGZHOU MARINE FITTINGS CO,.LTD
无锡市东舟船舶附件有限公司

from ctrl box


来自控制箱

RS-A

RS-B
CPU2

开门信号
K7

1#DOOR OPEN
蜂鸣器
BUZZER
关门信号 综合报警
K8

1#DOOR CLOSE
K6

GROUP FAULT
门旁警铃
K9
DRWG NO.

ALARM-BELL
图号

门旁警灯
K10

ALARM-LAMP
W.T.Control Box-Alarm Section
水密门控制箱-报警部分
WUXI DONGZHOU MARINE FITTINGS CO,.LTD

K7
无锡东舟船舶附件有限公司

119 开门阀
YV1

DOOR OPEN-VALVE
400

K8

120
SBK-KZX-YL

关门阀
YV2

DOOR CLOSE-VALVE
K6
401

K9

123 门旁警铃
ALARM-BELL
DL1
GROUP FAULT
综合故障

K10

124 门旁警灯
ALARM-LAMP
6-02
PAGE
页数
HL7,9 指示灯 LAMP AD11-22/21-7ZG (Green) DC24V 2 Changjiang
HL3-6,13 指示灯 LAMP AD11-22/21-7ZG (Red) DC24V 5 Changjiang
1HL3-4 指示灯 LAMP AD11-22/21-7ZG (Green) AC220V 2 Changjiang
HL1-2 指示灯 LAMP AD11-22/21-7ZG (White)DC24V 2 Changjiang
SA1 按钮 PUSH BUTTON LA38-22S/203 (Green) 1 Changjiang
SB0,3,6,8 按钮 PUSH BUTTON LA38-11/203 (Red) 4 Changjiang
SB1-2 带灯按钮PUSH BUTTON LA38-11D/203(Red,Green)DC24V 2 Changjiang
SB5,7 按钮 PUSH BUTTON LA38-11/203(Green) 2 Changjiang
FM 蜂鸣器 BUZZER CDY22 DC24V 1 Changjiang
T1 变压器 TRANSFORMER BK3-160VA AC690V/AC220V 1 Fujie
K1-10 继电器 RELAY AHN22324 8 Panasonic
FU1-3,8 熔断器 FUSE SAKSAI4 2A 5 Changjiang
FU4-7,9 熔断器 FUSE SAKSAI4 4A 5 Changjiang
KD 开关电源SWITH POWER MW-100-24 1 Meanwell
V1-2 硅整流桥 RECTIFIER 3510 3 Toshiba
KM 接触器AC CONTACTORS LC1D09M7 AC220V(D类。库存) 1 Schneider
QF 开关 BREAKER GV2-ME08C+S225+AD1010 1 Schneider
CPU1 CPU224 DC/DC/DC UN 214-1AD23-OXB8 1 unimat
CPU2 EM222 DC24V 8出 UN 222-1HF22-OXA0 1 unimat
图号 SBK-KZX-YL 页数
福建马尾MW619平台供应船 水密门控制箱 电器图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels W.T.DOOR CONTROL BOX CIRCUIT DIAGRAM 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
6-03
TX1 TX2
隔离端子

L1 L2 L3 U V W Z+ Z- Z1- 200 Z1- 201 14 15 14 16 119 Z1- 120 Z2+ 205 Z1- Z2+ 206 Z1-
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
1 2 3 1 2 3 1 2 1 2 1 2 1 2 1 2 1 22 1 1 2 3 1 2 3
WST5,3×1.5

WST4,2( 2×1.5)
WST2,2×1

WCB1,2×1

WCB5,3×1

WCB6,3×1
来自应急配电板690V电源

WST6,2×1
WST3,2×1
FORM CHP DC24V POWER
FORM EMS 690V POWER

来自充放电板DC24V
3*2.5

2*2.5

DDV1 DDV2
1 2 1 2 1 2 1 2

1
2
3

1
2
3
open valve

close valve

+
-

-
关门阀
开门阀

BK

BU

BK

BU
BN

BN
PS3

PS1

PS2
LK

NPN

NPN
电动机 低油位
低油压报警 低压停启泵 高压停启泵 电磁阀 开门到位 关门到位
Motor LOW OIL LEVEL Low oil pressure Low oil pressure high oil pressure Solenoid valve open the door close the door
alarm start stop in place in place
Z1- 123 124 Z1- 123 124 Z2+ Z1- 207 208 209 107 108 Z2+ Z1- 207 208 209 107 108 Z1- 107 108 111 400 401 Z1+ Z1- RS-A RS-B RS-A RS-B
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57
1 2 3 1 2 3 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 1 2
1 21 2

TO WHC REMOTE PANEL

shielded twisted pair cable

shielded twisted pair cable


2*2*0.75 带屏蔽双绞线
TO驾驶室遥控板

2*2*0.75 带屏蔽双绞线
至控制室遥控板
来自水密门控制箱
WCB8,2*2.5
WCB1,7×1

WCB2,7×1

WCB7,5×1

WCB9,2×1

from ctrl box

TO WHC
WCB3,3×1

WCB4,3×1
1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4

开门指示
关门指示

开门指示
关门指示

开门指示

关门指示
综合故障
开门钮

关门钮

门停钮

开门钮

关门钮

门停钮
电源

电源
1 2 3 1 2 3

CLOSE IND.

CLOSE IND.

CLOSE IND.
通讯电缆布置详见系统图
PB1 PB2 PB3

OPEN

OPEN
STOP

STOP
Communication cable specific connection
refer to system diagram

OPEN IND.

OPEN IND.

OPEN IND.
COLSE

COLSE
AMS

COMM ALARM
POWER

POWER
门左警铃 门右警铃 门旁按钮盒 上甲板指示盒
alarm bell(lift) alarm bell(rith) 门旁按钮盒 ECC
Door left button box Door left button box Door left button box
图号 SBK-KZX-JXT 页数
福建马尾MW619平台供应船 水密门控制箱 外接线图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels W.T.DOOR CONTROL BOX EXTERNAL WIRING DIAGRAM 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
7
图号 SBK-JL 页数
福建马尾MMC887平台供应船 带灯警铃 外形图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MMC887 Platform supply vessels ALARM WITH LIGHT OUTLINE DRAWING 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
8
外部接线图
EXTERNAL WIRING DIAGRAM
3
OPEN DOOR
SB1
door open
4
SB2
door close
CLOSE DOOR 5
SB3
door stop
6
SB1/HL1
STOP DOOR/POWER
door open lamp
7
SB2/HL2
door close lamp
OPERATION/INDICATION BOX
1
SB3/HL3
power
2
1.型号:ANH-3 PG21( 13- 18)
Model:ANH-3
2.材质:铜质 SB1/HL1 LA38-10D/203D 红 DC24V 1
Material:Brass
3.IP 等级 : IP68 SB2/HL2 LA38-10D/203D 绿 DC24V 1
IP Rating : IP68
4.颜色:淡灰 LA38-10D/203D 红 DC24V 1
color:grey SB3/HL3
图号 SBK-ANH 页数
福建马尾MW619平台供应船 按钮盒 外形图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MW619 Platform supply vessels button box OUTLINE DRAWING 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
9
外部接线图
EXTERNAL WIRING DIAGRAM
1
BZ
蜂鸣器 AD16-22M/K23+F1
buzzer 2
HL1 R
门开 AD16-22D/r23S+F1
door open 3
HL2
门关 G AD16-22D/g23S+F1
door close
4
1.Model:SBK-XS1-3
2.Material:A-alloy
3.IP Rating : IP67
4.color:RAL7032
图号 SBK-ZSH 页数
福建马尾MMC887平台供应船 上甲板指示盒 外形图 无锡市东舟船舶附件有限公司
DRWG NO. PAGE
MMC887 Platform supply vessels upper deck indicator OUTLINE DRAWING 无锡东舟船舶附件有限公司
WUXI DONGZHOU MARINE FITTINGS CO,.LTD WUXI DONGZHOU MARINE FITTINGS CO,.LTD
10
Hydraulic sliding watertight door

Operating Specification
262WDF015B-00SC

Wuxi Dongzhou Marine Fittings Co., Ltd.


无锡市东舟船舶附件有限公司
船用液压滑动式水密门 操作手册 262WDF015-00SM
1.Remote-control of the watertight door
In the wheelhouse control panel sets the selector switch of “door close”
and “separately close”、“local central”.
1.1 When the selector switch put in the “door close”model, watertight
doors can automatic close and the alarm horn sends out sound before closing
the door 5---10s. The indication light of the door keeps red in the
wheelhouse control panel;When the watertight door begins to close,the red
light flash; When the door is completely closed, the red light of door go
out and the green light illuminant , the alarm horn with lamp beside the
door stops working. The open course ends.
1.2 When the selector switch is in the “separately close”model, it can
close the corresponding watertight door separately by the way of the
wheelhouse control panel. The work course as 1.1.
In the “door close”and “separately close”model, after closing the
watertight door, it can be opened locally beside the door, but after locally
control, the door can be automatically closed after 40S.
1.3 When the selector switch in the wheelhouse control panel in the “local
central ” model, it can’t operate the watertight door in the
wheelhouse control panel. At other times the selector switch in the
wheelhouse control panel is in the “local central”model, only in the
special situation the selector switch is in the “door close”model.

2. Locally-control of the watertight door


2.1 Power drive operation
2.1.1 Beside the door,press the close button in the control Ind. button
box. When the watertight door begins to move, the alarm horn beside the
door begins to sound. When the door is closing, the red light flash; when
the door is completely closed, the door state indication light of the
control Ind. button box: the red light of door go out and the green light
illuminant. the alarm horn beside the door stops working. The close course
ends.
2.1.2 Beside the door,press the open button in the control Ind. button
box. When the watertight door begins to move, the alarm horn beside the
door begins to sound. When the door is opening, the green light flash; when
the door is completely open, the door state indication light of the control
Ind. button box: the green light of door go out and the red light illuminant.
the alarm horn beside the door keeps working. The open course ends.
If press the stop button when the door is moving,the door immediately
stops but the alarm and the indication keeps holding on.When control
locally , the indication light of the door in the wheelhouse control panel
keeps abreast of the local indicator.
2.2 Manual operation
2.2.1 Operate the hand-operated direction valve beside the door to the
position of “open door”,shake the hand pump,the door opened.The alarm

2
无锡市东舟船舶附件有限公司
船用液压滑动式水密门 操作手册 262WDF015-00SM
and indication same as the Power drive operation course.
2.2.2 Operate the hand-operated direction valve beside the door to the
position of “close door”,operate the hand pump,the door closed. The alarm
and indication same as the Power drive operation course.
Operate the hand pump unit,the watertight door can be fully closed or
opened in 90s.
The hand-operated direction valve normally to be fixed on the middle
position.

3
Hydraulic Sliding Watertight Door

Test Program
262WDF015B-00SY

Wuxi Dongzhou Marine Fittings Co., Ltd.


May 2013
无锡市东舟船舶附件有限公司
船用液压滑动式水密门 试验大纲 262WDF015B-00SY

1 Product name and range of applicability:

1.1 This product-----horizontal sliding hydraulic watertight door is

used in the engine room to the shaft passage and below the main

deck.

1.2 This test program is suitable to the above hydraulic watertight

door release testing and version testing.

2 Reference standard:

2.1 CB/T3007-2011 Hydraulic Watertight Door

2.2 SOLAS Convention 2009 Amended

2.3 Hydraulic Watertight Door corporation standard

3 Test item and requirement:

3.1 Check the producing material’s physical chemistry performance

according to the requirements of marine material rules.

3.2 Check the appearance size of hydraulic watertight door, it

should according to the approved drawings, error should in the

range of the required tolerance.

3.3 Check the surface quality of the watertight door, the doorframe

and the doorleaf are weldment. The seam should glabrous, not

existing air cavity, crack, and included slag and undercut etc.

flaw. The surface should glabrous, not existing burr and closed

angle etc. flaw.

3.4 The assembly sliding watertight door should carry out the

2
无锡市东舟船舶附件有限公司
船用液压滑动式水密门 试验大纲 262WDF015B-00SY

hydraulic pressure, the test pressure is the height of the hose

equaling to the height of the bulkhead deck, but the minimum

pressure is not more than 0.1MPa.

3.5 Hydraulic sliding watertight door should carry out the

hydraulic system test and the flexibility test. When the ship is

floating, it can close all the doors in 60s in the wheelhouse

control panel. It can close any a door by the manual operation

device in no more than 90s. When closing any a door P1 by

motor, the speed should equality. When the ship is floating,

the time from starting sliding to completely close, in any case,

is not less than 20s and not more than 40s.

3.6 Hydraulic sliding watertight door should carry out closing test

listing 15○.

Hydraulic sliding watertight door can close the doors, whether

by motor or by manual, when any other shipboard listing 15○.

At one time it should think over that any other side of the door

getting acting force equal to the lenitic pressure in the midline

of the door above the sill one meter.

Each hydraulic watertight door must set one separately manual

operation device. At both sides of the door it can be opened

and closed.

3.7 Hydraulic sliding watertight door should carry out the

3
无锡市东舟船舶附件有限公司
船用液压滑动式水密门 试验大纲 262WDF015B-00SY

open-close test of “control model”. When in “local control”

model, it should open and close any sides of doors locally.

When in “door close”model, it can close any opening doors

automatic. The “door close”model permit opening the door

locally. When coming away the control device, it can recluse

the door automatic. It can not remote opening any a door from

the control panel.

3.8 Open the power or manual device, it should test the indication

device of opening and closing door when closing the door. It

should test the alarm device when by power or manual.

The hydraulic sliding watertight door set the control device

using the power to open and close doors at the sides of the

door and set the opening and closing door device from the

general control panel using power in the wheelhouse. In the

remote operation position should set the indication institution

to indicate whether these doors are open or not.

Hydraulic sliding watertight door should set a sounding alarm

machine different to other alarm machines in this area. When

remote controlling closing the doors by power, the alarm

machine send out voice until the doors are completely closed

before sliding the door at least 5s but not more than 10s. When

sliding the doors the sounding alarm machine send out voice

4
无锡市东舟船舶附件有限公司
船用液压滑动式水密门 试验大纲 262WDF015B-00SY

only in the situation of manual remote control.

4 This test program is drawn up by Wuxi Dongzhou Marine Fittings Co.,

Ltd. technical department.

Main Draftsman:Hua Jian-chun

check:Wu Hai-ba

Approved:Lai Gang

5
Hydraulic Sliding Watertight Door

Installation and maintenance manual

会 签

Hydraulic Sliding Watertight Door 技术设计

旧底图登记号
标记 数量 修改单号 签 字 日 期 说明书 262WDF015B-00SM
编 制 EDIT
共 7 页 第 1 页 PAGE 1 OF 7
校 对 CHKD
R

底图登记号
审 核 RVE 无锡市东舟船舶附件有限公司
标 检 STD WUXI DONGZHOU MARINE FITTINGS CO,.LTD.
Tel: (86510)83778700-822 Fax: (86510)83771228 E-mail: WUXIDONGZHOU@126.COM

审 定 APP 技术资料和知识产权都属于无锡市东舟船舶附件有限公司,未经本公司书面同意,任何单位和个人不得拷贝,复制和使用.
R
第 2 页
Installation and maintenance manual 262WDF015B-SM
共 7 页

Catalogue
A. Installation manual of hydraulic watertight sliding door----------------------------3
1. General-------------------------------------------------------------------------------------3
2. Installation of hydraulic watertight sliding door--------------------------------------3
3. Installation of hydraulic system---------------------------------------------------------3
4. Electric Installation------------------------------------------------------------------------3

B. Maintenance manual of hydraulic watertight sliding door-------------------------5


1.General---------------------------------------------------------------------------------------5
2. Common faults and maintenance of hydraulic watertight sliding door------------5
3. Maintenance of hydraulic watertight sliding door------------------------------------7

无锡市东舟船舶附件有限公司 Tel: (86510)83778700 Fax: (86510)83771228 E-mail: WUXIDONGZHOU@126.COM


R
第 3 页
Installation and maintenance manual 262WDF015B-SM
共 7 页

A.Installation manual of hydraulic watertight sliding door


1. General
The hydraulic sliding watertight door made in Wuxi Dongzhou Marine Fittings Co., Ltd.
is acceptable for the engine room to the shaft passage and below the main deck,and also
to the platform deck etc. places. The capability accords to the 2009SOLAS Convention
amended.
The watertight bulkhead sliding door consists of watertight door, EL-hydraulic unit,
hand operated pressure unit, EL-control box system(EL-control box, alarm indicate box,
wheelhouse control panel, position switches and button box beside the door) etc.

2. Installation of hydraulic sliding watertight door


2.1 The opening size of watertight bulkhead (to be checked before door
installation),the flatness of bulkhead opening is less than 3mm,to make the bulkhead flat
if more than 3mm.
2.2 hydraulic sliding watertight door shall be kept horizontal with the vessel when it is
fixed.The guide shall be fixed by guide fixed seat.
2.3 hydraulic sliding watertight door welding
2.3.1 Hydraulic sliding watertight door is to be fixed and closed on the bulkhead Four
angles of door are to be welded on the bulkhead,and followed the rest parts. Welding
deformation shall be noted during welding.
2.3.2 To avoid the continuous and long time welding as welding deformation needs to
be considered.Space welding for the front and the back shall be carried out,and door
shall be closed when welding in order to reduce welding deformation.
2.3.3 Gas cavity and dry joint shall be checked after welding .No water leakage is
allowed at the welding parts.

3. Installation of hydraulic system


3.1 Installation for electric and hand hydraulic pump units will be provided by
seller .Valve components have been already fitted on the pump units.
3.2 Electric, manual hydraulic pump group shall be fitted near doors without effecting
crews to be passed.(without effecting the maintenance and installation )
3.3 Please refer to 262WDF015B-YY-01 for pipe connection of hydraulic sliding
watertight door.Please note the nameplate of our company during pipe connection.

4、Installation of Electric Equipment


无锡市东舟船舶附件有限公司 Tel: (86510)83778700 Fax: (86510)83771228 E-mail: WUXIDONGZHOU@126.COM
R
第 4 页
Installation and maintenance manual 262WDF015B-SM
共 7 页

4.1 Control box and alarm box of hydraulic sliding watertight door with electric,
manual hydraulic pump groupAre to be assembled together.
4.2 Button box and alarm ring with light shall be fitted on both sides of door.Indicated
box on the upper deck shall be fitted near the hand pump of the upper deck.(one button
box and control box are to be connected together.)
4.3 Position switch shall be fitted with hydraulic sliding watertight door ,(there is the
installed hole in the hydraulic sliding watertight door)

After completing installation of door,the oil shall be filled to the oil tank,hydraulic pipe
connection is to be finished and the cables of electrical equipment are to be
connected,then debugging can be performed for doors.

无锡市东舟船舶附件有限公司 Tel: (86510)83778700 Fax: (86510)83771228 E-mail: WUXIDONGZHOU@126.COM


R
第 5 页
Installation and maintenance manual 262WDF015B-SM
共 7 页

B.Maintenance manual of hydraulic watertight sliding door


1. General
Debugging and maintenance are required after hydraulic sliding watertight doors
installed. Periodic maintenance of watertight doors can extend the life of doors.

2. Common faults and maintenance of hydraulic watertight sliding door


To check whether there are damaged components, whether the installation of watertight
doors are put in the right place in the presence first.To coordinate and solve problems
with shipyard timely if inconsistency. And then clean watertight doors and tanks..
2.1 To clean tanks before fueling ,and ensure there are no rusts and stains in the tanks.
To check the level gauge after filling up ,and whether there is oil leakage in the oil
outlet. Sealings and damaged parts shall be replaced timely if oil leakage found.
2.2 To shake hand pump ,check whether there is oil leakage for the external pipes after
no oil leakage found ,it shall be solved in time if oil leakage found.To check whether
there are rusts for the contact surface of watertight doors,it shall be solved in time if
abnormal found.To coat greases on the contact surface, working face of rubber strips
and guide pintles. And then check whether watertight doors can be closed in 90 seconds
and the pressure should not exceed 2.5Mpa when closing . Guide adjusting screws of
watertight doors shall be adjusted if exceeds, check the contact surface of doors by
feeler gauge.To put paper under rubber strip of watertight doors if deformation of door
frames is caused and can not be adjusted by the improper operation from the shipyard.
To check the hand pump in front of doors,behind doors and the upper deck whether it
works properly, should be used repeatedly as there is air in the pipes.
2.3 Power-on after the line is checked by the electrician , and open power switch in the
control box. ( The Motor changeover buttons with manual and automatic should be in
manual position). To loose adjusting screws of the relief valve and locking screws of
one-way valve , repeatedly press the starting button and check one-way valve if there is
oil emerged.The motor will be shown as counter rotation If there is no oil emerged and
the wiring is to be replaced.
2.4 To slowly increase relief valve pressure, check whether there is oil leakage for
pipe joints of the pressure gauge .Please solve it timely if oil leakage found. To note if
there is abnormal sound for the motor during the increasing process. Relief valve
pressure shall be increased to 7-7.5Mpa, and then reduced to 3Mpa.To adjust the
adjusting nuts of pressure controller for the low-pressure alarm(tight: pressure is high,

无锡市东舟船舶附件有限公司 Tel: (86510)83778700 Fax: (86510)83771228 E-mail: WUXIDONGZHOU@126.COM


R
第 6 页
Installation and maintenance manual 262WDF015B-SM
共 7 页

loose: pressure is low) to enable the alarm light flashing. Repeated several times .
2.5 To turn on change-over switch of the motor to automatic,adjust relief valve pressure
to 3Mpa, adjust low-pressure controller until the motor is started,and then increase the
pressure controller , keep the pressure to 7.5Mpa and stop. (Tight : pressure is high,
Loose: pressure is low). A multimeter can be used if adjustment does not work .To
adjust relief valve pressure to 3Mpa, unplug the wiring socket and adjust low-pressure
controller to be connected, repeated several times.The replacement will be needed if it
does not work. If ok ,then check if the wiring socket is broken.
2.6 To simulate low oil level alarm by the liquid level relay, (the motor will not be
started if low oil level alarm light flashes). To check whether the alarm indicated light is
on , check whether the connection is ok if the light is off, or check whether the light is
damaged by the multimeter .One light is alarmed only for all alarm lights, all general
faults alarm indicated lights at the wheelhouse shall be turned on while the buzzer is
sounded.
2.7 Press the closing button, check if the door is moving. Check if there is power
output and the electromagnetic valve is working. If both are good, watertight door is not
moved ,adjust the throttle valve, check if the electromagnetic valve is seizing. If all
above are good and watertight door is opened to the right place, then check if the
connection of position switch is wrong.(The speed cf watertight door is controlled
between 20-40 second by the throttle valve). Door opening as well. It should be
operated in front of door and behind door..
2.8 To open watertight door completely,put the pressure to 7Mpa,turn off the
power.Open and close watertight door for three times by the button
box(close-open-close).Check the pressure of accumulator to be 2.8Mpa(release
Nitrogen if high,fill Nitrogen if low) if it does not work.(Remove the pressure before
checking).The pressure of closing door is too high if still not work.Adjust the locking
device of watertight door asgain,ensure the watertight of doors.
2.9 Check if the indicated lights of opening and closing door of wheelhouse remote
plate has the same status with the control box of door, check the silencer, test lights and
dimming function.
2.10 Turn the changeover switch of wheelhouse remote plate tothe separate
closing,press the closing button which can close watertight door.Door is to be closed
after the alarms near watertight door send out 5-10 seconds,open it locally,the alarm is
still on going,door is to be closed after 5-10 seconds.
2.11 Check the alarm first,then check hand operation and the remote operation of
无锡市东舟船舶附件有限公司 Tel: (86510)83778700 Fax: (86510)83771228 E-mail: WUXIDONGZHOU@126.COM
R
第 7 页
Installation and maintenance manual 262WDF015B-SM
共 7 页

wheelhouse during testing in the presence.

3. Maintain
3.1 The door should carry out regular maintain. When assembly and clean the door’s
hydraulic pipes, it should according to CB1102.3、CB1102.4
3.2 Regular clean the surface of the door, especially the guide finger and should coat
the lubricating oil.
3.3 Regular check the seal rubber, it should not exist fray. If it has affected the
watertightness, it should change. The seal rubber should clean at other times and coat
lubricating oil.
3.4 Regular check the hydraulic pipe fitting, if it has petrol dripping, it should
maintain in time.
3.5 Regular check the joint, if it has loosening, it should maintain in time.
3.6 Write the maintain record of the door.

无锡市东舟船舶附件有限公司 Tel: (86510)83778700 Fax: (86510)83771228 E-mail: WUXIDONGZHOU@126.COM

You might also like