You are on page 1of 6

Model No.

83167
AIR OPERATED GREASE PUMP
Series "H"
LUBRICANT OUTPUT
RESERVOIR AIR LUBRICANT OPERATING PRESSURE (PSI)
RATIO (cu. in.) LUBRICANT
PER PER MIN. CAPACITY INLET OUTLET TYPE OF
MINIMUM MAXIMUM
RECOM-
CYCLE (@100PSI) SYSTEM MENDED
SL-1 2,500
1,850 3,550
12 12 LBS. 1/8" 3/4" SL-11
40:1 *.11
NPTF(F) NPTF(F) SL-32
SL-33 1,200 3,550 1,500

TYPICAL
INSTALLATION

The 83167 Pump is used as the


pumping unit for a centralized
lubrication system having a single
line circuit of SL-1, SLS-11, SL-32,
OR SL-33 Injectors.

It is an air operated reciprocating


pump that discharges an established
amount of lubricant *(.11 cu. in.) into
the circuit for each pump cycle.

*Based on lubricants that are free


of entrapped air. Lubricants that are
aerated will reduce output of pump.

FILL RESERVOIR
Use 81834 Manual Filler Pump to fill reservoir through the filler
fitting in the pump body. Attach coupler on delivery hose to filler.
Stroke filler pump handle until lubricant weepage is noted at air
vent hole in reservoir (lower portion of follower must rise beyond
air vent hole to expel entrapped air from lubricant).
NOTE: When filling the reservoir, caution should be used as extreme
pressure can cause damage to reservoir and follower assembly.

One Lincoln Way


Copyright 2005
Section - C8
St. Louis, Missouri 63120-1578
(314) 679-4200
Printed in U.S.A. Page - 85T
JULY - 2005
FORM 403574
©

SERVICE PARTS
Part Qty. Description Part Qty. Description Part Qty. Description
#*10061 1 Pump check disc #*34158 1 Gasket (Neoprene) 68797 1 Plug button
10127 1 Plug 34166 1 O-ring (Nitrile) 69034 1 Retaining ring
10772 1 Nipple *34229 1 Packing (Nitrile) 69181 1 Lockwasher
11470 1 Cap 34308 1 Gasket (Nitrile) #*83063 1 Valve slide, seat & gasket assembly
#*11471 1 Trip rod collar #*34314 1 O-ring (Nitrile) 83948 1 Vent valve assembly
#*11472 1 Trip rod pin 34438 1 Follower 84508 1 Bushing, plunger & O-ring assembly
#*11475 1 Trip shoe #*38162 1 Valve gasket (Nitrile) #*90770 1 Trip rod
11904 1 Packing nut 40821 1 Base casting *90942 1 Safety unloader
11905 1 Packing cap #*45605 1 Valve guide plate #*91331S 1 Toggle plate
#*11947 1 Trip sleeve 48140 1 Washer 91817 1 Reservoir cap
12093 1 Check housing 48212 2 Washer 92242 1 Bushing & washer assembly
12094 1 Air piston bolt 48216 1 Washer 92441 1 Filler fitting
12095 1 Outlet body 48237 1 Washer 236286 1 Cover
12096 1 Outlet block 48417 1 Follower washer 236615 1 Muffler cover
12511 2 Pipe plug 50000 6 Screw #*236616 1 Gasket
12834 1 Spring retainer 50086 1 Bolt 236833 1 Muffler
13808 1 Adapter 50521 4 Screw #*236835 1 Packing (Nitrile)
14449 1 Tie rod 51039 1 Nut 236868 4 Screw
14491 1 Retainer washer 51099 1 Nut 236869 6 Screw
14720 1 Air cylinder 55138 4 Spring 236870 4 Valve seat bolt
14721 1 Piston 55231 1 Spring 237562 1 Air valve casting
*14722 1 Needle 55346 1 Follower spring 239330 1 Viton packing assembly
*14723 1 Valve seat #56003 1 Spring 239336 1 Valve body
14727 1 Reducer nipple #56038 2 Spring #*244313 1 Seat
16471 1 Support adapter 66002 1 Steel ball #*244359 1 O-ring (Nitrile)
#30003 1 Gasket #*66010 2 Steel ball #*245425 1 Trip rod packing nut
#*31007 2 Gasket 66186 1 Lockwasher #246816 1 Gasket
31047 2 Gasket 66200 1 Straight tube connector 247244 1 Reservoir (acrylic)
31054 1 Gasket 66201 1 90 degree tube connector #247611 1 Gasket
#31056 1 Gasket (Nitrile coated fiber) 66210 1 90 degree tube connector 247763 1 Nylon tubing
#*33039 1 Gasket (Nitrile) 66211 1 Straight tube connector 272724 1 Nylon tubing
34090 1 Packing (Nitrile) 66246 6 Lockwasher 360383 1 Base
#34110 1 Packing (Nitrile) 67011 1 Tee 361066 1 Bracket
*34122 1 Check disc packing 68528 1 Strainer 633102 1 Plug

© Indicates Change 274225© 1 Retaining Ring

*Recommended Service Parts Inventory. #Included in 246415 repair kit.


Page 2 Form 403574
247611

TO LUBRICATE
AIR VALVE MECHANISM

Disconnect air to pump, remove the four cover screws, cover plate
and cover gasket.

Remove and disassemble the air valve casting from the pump.

The air valve casting should be cleaned or flushed to remove any


chips, or other foreign particles prior to re-assembly.

Before replacing the toggle assembly, pack cavity with grease.

Form 403547
Use NLGI No. 1 (light grade) water repellent grease.
Approximately
1 1/2 ounces.

Replace cover gasket, cover and screws. Tighten to avoid air


leaks.

Page 3
INSTRUCTIONS FOR PUMP USING 85209 CONTROL PANEL
TO PRIME SYSTEM
SUPPLY LINES: INJECTORS:
After pump reservoir has been filled with recommended lubricant, Check the injectors for proper operation by observing the movement
loosen all plugs in dead ends of injector manifolds and supply lines. of the indicator stems.
Turn vent plug in pump counter-clockwise one complete turn. Depress OPERATION:
manual lube pushbutton on door to start pump. Operate pump until When model 85530 times out it will initiate a lube cycle. The air
lubricant bleeds around vent plug to expel air pockets trapped between solenoid is energized to deliver air to the pump and air to the vent
the pump and the supply line connection. Tighten vent plug. continue valve. Pump begins dispensing lubricant through injectors to the
operating pump unitl lubricant flows around any plug. Tighten plug. bearings.
Repeat this procedure until all plug openings are tight and supply lines When all bearings have received lubricant, pressure rises in system
are primed. Turn off power to reset controller. to actuate pressure switch. When pressure switch actuates, the
IMPORTANT: control is reset to de-energize solenoid valve cutting off air to pump
Refer to Owner/Operator Manual C8 259 to program controller on and vent valve. Pump stops, pressure vents and pressure switch
85209. de-actuates. Control begins timing toward next lube event.
FEEDER LINES:
Fill each feed line with lubricant before connecting lines to outlets of
injectors and bearings. This will prevent having to cycle each injector
to fill the feed line between injector and bearing.

INSTRUCTIONS FOR PUMP USING 83820 TIME CONTROL


TO PRIME SYSTEM OPERATION
SUPPLY LINES: The timer (runs constantly when current is on), drives a cam which
After pump reservoir has been filled with recommended lubricant, has lobes set for the desired lubrication cycle frequency (Refer to
loosen all plugs in dead ends of injectors manifolds and supply lines. Service Manual Section C8, Page 133 Series). Lobes engage the
Turn vent plug in pump counter-clockwise one complete turn. Set the micro-switch lever arm to activate the switch, closing the circuit to
delay relay to its maximum position (Refer to Service Manual Section open the 3-way solenoid air valve permitting air to operate the pump.
C8, Page 133 Sefies). Depress push button on top of time control The pump discharges lubricant through the supply line to the injectors.
to start pump. Operate pump until lubricant bleeds around vent After the injectors operate (discharge lubricant to the bearings), pump
plug to expel air pockets trapped between the pump and the supply continues to build up lubricant pressure in the supply line until sufficient
line connection. Tighten vent plug. Continue operating pump until to operate the pressure control which moves a switch plate, breaking
lubricant flows around any plug. Tighten plug. Repeat this procedure the circuit to the 3-way, solenoid air valve, shutting off the air to the
until all plug openings are tight and supply lines are primed. Open pump. Injectors automatically, re-charge with lubricant and system
line switch to shut off pump. is ready for the next lubrication cycle.
IMPORTANT:
The pressure control is factory set for 2,500 psi, adequate for any normal
Reset the delay relay to desired interval (Refer to System Planning installation. If higher pressure is necessary (2,900 psi maximum), the
Manual). pressure control can be reset;
FEEDER LINES: 1) Loosen locknut.
Fill each line with lubricant before connecting lines to outlets of 2) Turn the housing clockwise into the pressure control body until
injectors and bearings. This will prevent having to cycle each injector proper pressure is obtained.
to fill the feed line between injector and bearing. 3) Tighten locknut.
INJECTORS: To lower pressure (1,500 psi minimum);
Check injectors for proper operation by observing the movement of 1) Loose locknut.
the indicator stems. 2) Turn the housing counter-clockwise into the pressure control
body until proper pressure is obtained.
3) Tighten locknut.

VENT VALVE: WHAT TO DO IF:


The 83948 Vent Valve is operated by compressed air from the same Pump loses prime: Check lubricant supply.
source which operates the pump. When pump is in operation, air 10127 Vent Plug is provided at the pump outlet for expelling air which
pressure keeps the vent valve closed and lubricant is directed through the may be pocketed in the lubricant. If pump operated continuously
outlet and to the injectors. When air to the pump is shut off, vent valve without discharging lubricant, it is an indication that the pump has lost
opens and supply line pressure vents back into the reservoir. its prime. Loosen the vent plug one turn until trapped air is pumped out.
SAFETY UNLOADER: If pump continues to operate without discharging lubricant, 10061 Pump
90942 Safety unloader is provided at the pump outlet to prevent Check and 66002 Steel Ball may be fouled. Remove and clean checks
the build-up of dangerously high lubricant pressure in the system. It and check seats. The 83948 VentValve may also be fouled. Foreign
is factory set to open at approximately 3,750 psi to 4,250 psi. material may prevent 14722 Needle from seating proper]), or 14723
NOTE: Safety unloader requires no adjustment and should not be Valve Seat may be worn or damaged. Clean or replace parts.
tamperedwith. Failure of injectors to cycle can also be caused by a leak in the supply
line. Examine lines and connections.
Pump fails to operate: Check air supply.

RETAIN THIS INFORMATION FOR FUTURE REFERENCE


When ordering replacement parts, list: Part Number, Description, Model Number and Series Letter.
LINCOLN provides a Distributor Network that stocks equipment and replacement parts.

Page 4 Form 403574


Centro-Matic® Automated Lubrication Systems
Introduction

Lincoln Centro-Matic® systems and components are made to match your application. Systems can service one machine,
different zones on one machine, or even several separate machines. Regardless of the application, the principle of
centralized lubrication remains the same: a central pump station automatically delivers lubricant through a single supply
line to the injectors. Each injector serves only one lubrication point and may be accurately adjusted to deliver the precise
amount of grease or oil required. Centro-Matic systems give you multiple advantages over other designs.
Simplicity
Systems are easy to understand, install and maintain. You realize savings right from the start because one lubricant
supply line means lower installation costs.
Powerful Pumping Unit
Centro-Matic systems dispense either grease or oil in measured quantities, unaffected by normal temperature or
viscosity changes. For large systems, Lincoln’s single-line design and powerful pumps mean injectors can be located
long distances from original refinery containers or bulk lubricant tanks.
External Adjustment
Lubricant injectors are externally adjustable without special tools so each bearing can receive the correct amount of
lubricant. No under- or over-lubrication at individual points.
Visual Indicators
Each injector incorporates an indicator pin that gives visual confirmation the injector is operating correctly. When
necessary, troubleshooting is the simple process of checking indicator pins.
Ease of Service
When injectors finally need service, the job is quick and easy. No need to remove supply line connections or disturb
adjacent injectors. Replacement can usually be done between lubrication cycles, so there’s almost no lubricant loss
or downtime.
Parts and Service
You’re never far from a Lincoln authorized distributor. Qualified distributors offer design engineering, startup help, and
training for your personnel in the use and maintenance of Centro-Matic systems. They’ll back you up with parts and
service for years after the sale.

Air-Operated Electric Manual Hydraulic


Actuated automatically by Used where compressed air Designed for smaller, A complete hydraulically-
compressed air at various is not available, or electrical individual machines, manual powered pumping unit for
pre-determined intervals. operation is preferred. Totally systems provide a low-cost, centralized lubrication of
An air-operated pump enclosed motor supplies the efficient method of distribut- individual machines. Usually
delivers lubricant to the power requirements of the ing lubricant to the injectors. installed on machinery such
injectors. When all injectors pumping mechanism. Time Cycling a complete bank of as coal mining and earth
have cycled, the pump shuts control is adjustable to injectors takes only a few moving equipment which
off automatically and vents provide predetermined seconds. In manually- utilize a hydraulic pressure
lubricant pressure. Available frequency of lubrication. operated systems, the system. The frequency of
with automatic, manual or lubricant pump is hand- the lubrication cycle can be
mechanical controls. operated and the machine set manually or by mechani-
operator performs the cal or automatic controls.
lubrication intervals.

2
CONTENTS
Centro-Matic® Automated Lubrication Systems
Air–Operated (Reciprocating) Grease Pumps

Model 83167
Includes transparent reservoir, spring-loaded follower, vent valve assembly and
filler fitting for refilling of reservoir with 81834 filler pump or other manual pump
equipped with Model 645006 coupler.
Model: 83167
Lubricant/Air Ratio: 40:1
Output/Min @ 100 PSIG Air: 12 cu. in. 197 cc
Reservoir Capacity: 12 lb. / 5.44 kg 360 cu. in. / 5900 cc
Air Inlet: ¹⁄₈" NPTF (F)
Lube Outlet: ³⁄₄" NPTF (F)
Typical System Min. 1200 psig 82 bar
Operating Pressure: Max. 3500 psig 241 bar
Dimensions (HxWxL): 22¹⁄₂" x 9 "x 16¹⁄₄" 572 x 229 x 413 mm
Filling Method: 81834 Filler Pump
Reservoir: Translucent Acrylic
Notes: 1. Pump requires 3-way air valve. 2. Air consumption @ 100 psi is .15 CFM per cycle

Model 83599
Same as model 83167 except includes base mounting kit and metal reservoir
with indicator rod for visual check of grease level. Reservoir includes spring-
loaded follower.
Model: 83599
Lubricant/Air Ratio: 40:1
Output/Min @ 100 PSIG Air: 12 cu. in. 197 cc
Reservoir Capacity: 12 lb. / 5.44 kg 360 cu. in. / 5900 cc
Air Inlet: ¹⁄₄" NPTF (F)
Lube Outlet: ³⁄₄" NPTF (F)
Typical System Min. 1200 psig 82 bar
Operating Pressure: Max. 3500 psig 241 bar
Dimensions (HxWxL): 24³⁄₈" x 9 "x 18³⁄₁₆" 619 x 229 x 462 mm
Filling Method: 81834 Filler Pump
Reservoir: Aluminum
Notes: 1. Pump requires 3-way air valve. 2. Air consumption @ 100 psi is .15 CFM per cycle

19
CONTENTS