Various NC/PLC Interface Signals and Functions

DB number Byte.Bit Description


5.3.1 Signals to NC
DB10, DBX56.4 / .5 / .6 / .7 (switch positions 0 / 1 / 2 / 3)

5.3.2 Signals from NC


10 103.0 Remote diagnostics (MMC alarm is active)
10 103.5 AT box ready
10 103.6 MMC temperature limit
10 103.7 MMC battery alarm
10 104.7 NCK CPU Ready
10 108.1 MMCCPU2Ready (MMC to OPI or MPI)
10 108.2 MMC CPU1 Ready (MMC to MPI)
10 108.3 MMC CPU1 Ready (MMC to OPI, standard link)
10 108.6 Drive Ready
10 108.7 NC Ready
10 109.0 NCK alarm is active
10 109.5 NCU573 heat-sink temperature alarm
10 109.6 Air temperature alarm
10 109.7 NCK battery alarm

5.3.3 Signals to channel


21 6.2 Delete distance-to-go (channelspecific)

5.3.4 Signals from channel


21, 36.6 Channelspecific NCK alarm is active
21, 36.7 NCK alarm with processing stop present
21, 318.7 Overstore active

5.3.5 Signals to axis/spindle


31, 1.3 Axis/spindle disable
31, 1.4 Follow-up mode
31, 1.5 Position measuring system 1
31, 1.6 Position measuring system 2
31, 2.1 Controller enable
31, 2.2 Delete distance-to-go (axisspecific)/Spindle reset
31, 1, 2 Parameter set switchover (request)
31, 20.0 Rampup times
31, 20.1 Rampfunction-generator fast stop
31, 20.2 Torque limit 2
31, 20.3 Speed setpoint smoothing
31, 21.2 Drive parameter set selection A, B, C
31, 21.4 Motor selection A, B
31, 21.5 Motor selection to follow
31, 21.6 Speed controller integrator disable
31, 21.7 Pulse enable

5.3.6 Signals from axis/spindle


31, ... 60.4 / 60.5 Referenced, synchronized 1 / Referenced, synchronized 2
31, ... 61.3 Follow-up mode active
31, ... 64.6 / 64.7 Traverse command minus / plus
31, ... 61.3 Follow-up mode active
31, ... 61.4 Axis/spindle stops
31, ... 61.5 Position controller active
31, ... 61.6 Speed control loop active
31, ... 61.7 Current controller active
31, ... 1, 2 Parameter set switchover (feedback)
31, ... 76.0 Lubrication pulse
31, ... 92.0 Setup mode active
31, ... 92.1 Rampfunction-generator fast stop active
31, ... 92.2 Torque limit 2 active
31, ... 92.3 Speed setpoint smoothing active
31, ... 93.2 Active drive parameter set A, B, C
31, ... 93.4 Active motor A, B
31, ... 93.5 Drive Ready
31, ... 93.6 Speed controller integrator disabled
31, ... 93.7 Pulses enabled
31, ... 94.0 Motor temperature prewarning
31, ... 94.1 Heat-sink temperature prewarning
31, ... 94.2 Ramp-up function completed
31, ... 94.3 |Md| < Mdx
31, ... 94.4 |nact| < nmin
31, ... 94.5 |nact| < nx
31, ... 94.6 nact = nset
31, ... 94.7 Variable signaling function
31, ... 95.0 UDC link<warning threshold

5.3.7 Signals to operator panel front


19 0.0 Screen bright
19 0.1 Darken screen
19 0.2 Key disable
19 0.3 Delete Cancel alarms (HMI Advanced only)
19 0.4 Delete Recall alarms (HMI Advanced only)
19 0.7 Actual value in WCS
19 10.0 Programming area selection
19 10.1 Alarm area selection
19 10.2 Tool offset selection
19 10.7 ShopMill control signal
19 12.2 COM2 active (job byte of PLC)
19 12.3 COM1 active (job byte of PLC)
19 12.4 RS232 stop (job byte of PLC)
19 12.5 RS232 external (job byte of PLC)
19 12.6 RS232 OFF (job byte of PLC)
19 12.7 RS232 ON (job byte of PLC)
19 13.5 Unload part program
19 13.6 Load part program
19 13.7 Part program selection
19 14.7 File system active/passive (for HMI Embedded, always active)
19 16.7 File system active/passive (for HMI Advanced, always passive)
19 44.0 Mode change disable

5.3.8 Signals from operator panel front


19 20.1 Screen is dark
19 20.7 Switch over MCS/WCS
19 24.0 Error (Acknowledgment byte for current RS232 status)
19 24.1 O.K. (Acknowledgment byte for current RS232 status)
19 24.2 COM2 active (Acknowledgment byte for current RS232 status)
19 24.3 COM1 active (Acknowledgment byte for current RS232 status)
19 24.4 RS232 stop (Acknowledgment byte for current RS232 status)
19 24.5 RS232 External (Acknowledgment byte for current RS232C status)
19 24.6 RS232 OFF (Acknowledgment byte for current RS232 status)
19 24.7 RS232 ON (Acknowledgment byte for current RS232 status)
19 26.0 Error (Part program handling status)
19 26.1 O.K. (Part program handling status)
19 26.3 Active (Part program handling status)
19 26.5 Unload (Part program handling status)
19 26.6 Load (Part program handling status)
19 26.7 Select (Part program handling status)
19 42.0 FC9: Measure in JOG mode
19 45.0 FC9 Out: Active
19 45.1 FC9 Out: Done
19 45.2 FC9 Out: Error
19 45.3 FC9 Out: StartErr