10 103.0 Remote diagnostics (MMC alarm is active) 10 103.5 AT box ready 10 103.6 MMC temperature limit 10 103.7 MMC battery alarm 10 104.7 NCK CPU Ready 10 108.1 MMCCPU2Ready (MMC to OPI or MPI) 10 108.2 MMC CPU1 Ready (MMC to MPI) 10 108.3 MMC CPU1 Ready (MMC to OPI, standard link) 10 108.6 Drive Ready 10 108.7 NC Ready 10 109.0 NCK alarm is active 10 109.5 NCU573 heat-sink temperature alarm 10 109.6 Air temperature alarm 10 109.7 NCK battery alarm
5.3.3 Signals to channel
21 6.2 Delete distance-to-go (channelspecific)
5.3.4 Signals from channel
21, 36.6 Channelspecific NCK alarm is active 21, 36.7 NCK alarm with processing stop present 21, 318.7 Overstore active
5.3.5 Signals to axis/spindle
31, 1.3 Axis/spindle disable 31, 1.4 Follow-up mode 31, 1.5 Position measuring system 1 31, 1.6 Position measuring system 2 31, 2.1 Controller enable 31, 2.2 Delete distance-to-go (axisspecific)/Spindle reset 31, 1, 2 Parameter set switchover (request) 31, 20.0 Rampup times 31, 20.1 Rampfunction-generator fast stop 31, 20.2 Torque limit 2 31, 20.3 Speed setpoint smoothing 31, 21.2 Drive parameter set selection A, B, C 31, 21.4 Motor selection A, B 31, 21.5 Motor selection to follow 31, 21.6 Speed controller integrator disable 31, 21.7 Pulse enable
5.3.6 Signals from axis/spindle
31, ... 60.4 / 60.5 Referenced, synchronized 1 / Referenced, synchronized 2 31, ... 61.3 Follow-up mode active 31, ... 64.6 / 64.7 Traverse command minus / plus 31, ... 61.3 Follow-up mode active 31, ... 61.4 Axis/spindle stops 31, ... 61.5 Position controller active 31, ... 61.6 Speed control loop active 31, ... 61.7 Current controller active 31, ... 1, 2 Parameter set switchover (feedback) 31, ... 76.0 Lubrication pulse 31, ... 92.0 Setup mode active 31, ... 92.1 Rampfunction-generator fast stop active 31, ... 92.2 Torque limit 2 active 31, ... 92.3 Speed setpoint smoothing active 31, ... 93.2 Active drive parameter set A, B, C 31, ... 93.4 Active motor A, B 31, ... 93.5 Drive Ready 31, ... 93.6 Speed controller integrator disabled 31, ... 93.7 Pulses enabled 31, ... 94.0 Motor temperature prewarning 31, ... 94.1 Heat-sink temperature prewarning 31, ... 94.2 Ramp-up function completed 31, ... 94.3 |Md| < Mdx 31, ... 94.4 |nact| < nmin 31, ... 94.5 |nact| < nx 31, ... 94.6 nact = nset 31, ... 94.7 Variable signaling function 31, ... 95.0 UDC link<warning threshold
5.3.7 Signals to operator panel front
19 0.0 Screen bright 19 0.1 Darken screen 19 0.2 Key disable 19 0.3 Delete Cancel alarms (HMI Advanced only) 19 0.4 Delete Recall alarms (HMI Advanced only) 19 0.7 Actual value in WCS 19 10.0 Programming area selection 19 10.1 Alarm area selection 19 10.2 Tool offset selection 19 10.7 ShopMill control signal 19 12.2 COM2 active (job byte of PLC) 19 12.3 COM1 active (job byte of PLC) 19 12.4 RS232 stop (job byte of PLC) 19 12.5 RS232 external (job byte of PLC) 19 12.6 RS232 OFF (job byte of PLC) 19 12.7 RS232 ON (job byte of PLC) 19 13.5 Unload part program 19 13.6 Load part program 19 13.7 Part program selection 19 14.7 File system active/passive (for HMI Embedded, always active) 19 16.7 File system active/passive (for HMI Advanced, always passive) 19 44.0 Mode change disable
5.3.8 Signals from operator panel front
19 20.1 Screen is dark 19 20.7 Switch over MCS/WCS 19 24.0 Error (Acknowledgment byte for current RS232 status) 19 24.1 O.K. (Acknowledgment byte for current RS232 status) 19 24.2 COM2 active (Acknowledgment byte for current RS232 status) 19 24.3 COM1 active (Acknowledgment byte for current RS232 status) 19 24.4 RS232 stop (Acknowledgment byte for current RS232 status) 19 24.5 RS232 External (Acknowledgment byte for current RS232C status) 19 24.6 RS232 OFF (Acknowledgment byte for current RS232 status) 19 24.7 RS232 ON (Acknowledgment byte for current RS232 status) 19 26.0 Error (Part program handling status) 19 26.1 O.K. (Part program handling status) 19 26.3 Active (Part program handling status) 19 26.5 Unload (Part program handling status) 19 26.6 Load (Part program handling status) 19 26.7 Select (Part program handling status) 19 42.0 FC9: Measure in JOG mode 19 45.0 FC9 Out: Active 19 45.1 FC9 Out: Done 19 45.2 FC9 Out: Error 19 45.3 FC9 Out: StartErr