EMC® SVR-I1U-1208 Server Installation and

Maintenance Guide

P/N 300-013-549
REV 02

June, 2013

This document describes installation and maintenance procedures for the SVR-I1U-1208
server. This server has slots for eight 2.5-inch drive assemblies. Some server components
are replaceable as field replaceable units (FRUs). Refer to your product documentation for
information on which components are FRUs. Before attempting to perform hardware service
procedures, review your service contract because replacement of some server components
by unauthorized personnel may void service warranties.
Topics include:
u Technical information and requirements.................................................................... 2
u Installing the server in a cabinet.................................................................................3
u Maintaining the server............................................................................................. 14
u Replacing a disk drive assembly.............................................................................. 15
u Replacing a power supply module............................................................................18
u Replacing the server.................................................................................................19
u Removing the slide rails from the cabinet.................................................................28
Technical information and requirements
This section contains the following server information:
u Server power and cooling information on page 2
u Server dimensions and weight on page 2
u Server placement requirements on page 2
u Operating limits on page 3
u Shipping and storage requirements on page 3

Server power and cooling information


Table 1 on page 2 contains specifications for the server power consumption and
dissipation. Calculations based on this table are intended to provide maximum power
and heat dissipation. EMC provides a power and weight calculator at http://
powercalculator.EMC.com. Use this calculator to refine the power and heat values in the
table below to more-closely match the specific server hardware configuration. Ensure that
the server installation site meets the requirements for your configuration.

Table 1 Server power consumption and dissipation

Requirement Description
- -
AC line voltage 90-264 V AC, autoranging, 47- 63 Hz

Power consumption 900 VA (883 W) maximum (fully configured)


(operating maximum)

Heat dissipation 31.80 x 105 J/hr (3015 BTU/hr) maximum

Maximum inrush current 55 A per power supply for 6 ms or less under typical line
conditions and over the entire system ambient operating range

Server dimensions and weight


Table 2 Server dimensions and weight

Dimension Server Server with rails


- - -
Height 1.70 in (4.32 cm) 1.0 U (with or without bezel)

Depth 27.75 in (70.48 cm) 27.75 in to 29.5 in (70.48 cm to 74.9


cm)

Width 17.24 in (43.8 cm) without 18.99 in (48.24 cm) with cabinet latch
cabinet latch brackets brackets

Maximum weight 40 lb (18.1 kg) 45 lb (20.4 kg)

Server placement requirements


There are no restrictions on the location of the server in the cabinet. Allow at least 36
inches of service clearance in front of the cabinet. Power distribution must support the
number of outlets required for the server and the server power rating listed on the Device

2 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Rating label on the chassis. For additional information, refer to the preparation/planning
guides for your specific site and cabinet.

Operating limits
The ambient temperature specification is measured at the front bezel inlet. The site must
have air conditioning of the correct size and placement to maintain the specified ambient
temperature range and offset the heat dissipation listed in the table that follows.

Table 3 Operating limits

Requirement Description
- -
Ambient temperature 10°C to 35°C (50°F to 95°F)

Temperature gradient 10°C/hr (18°F/hr)

Relative humidity extremes 20% to 80% noncondensing

Recommended operating relative 40% to 55% noncondensing


humidity

Elevation -50 to 10,000 ft (-16 to 3,048 m)*

* For altitudes above 2,950 feet, the maximum operating temperature is de-rated 1°F/550 ft.

Shipping and storage requirements


Table 4 Shipping and storage requirements

Requirement Description
- -
Ambient temperature -40°C to 65°C (-40°F to 149°F)

Temperature gradient 25°C/hr (45°F/hr)

Relative humidity 10% to 90% noncondensing

Elevation -50 to 35,000 ft (-16 to 10,600 m)

Installing the server in a cabinet


To install the server in a cabinet you must perform the tasks below in the order listed.
This section describes how to perform each task.
1. Review the warnings and recommendations section.
2. Verify the contents of the mounting kit.
3. Adjust the rail assemblies for the cabinet channel holes.
4. Remove the inner rails from the rail assemblies.
5. Attach the inner rails to the server.
6. Install the slide rails in the cabinet.
7. Install the server on the slide rails in the cabinet.
8. Connect cables to the server.
9. Install the bezel on the server.

Operating limits 3
10. Power up the server.

Warnings and recommendations


The cabinet in which you will install the server must have a full earth ground to provide
reliable grounding. Also, the cabinet should have its own switchable power distribution.
We suggest that you use a cabinet that has dual power distribution units, one on each
side.
We recommend that you use cabinet anti-tip devices, especially if you are installing or
removing a server in the upper half of the cabinet when the lower half is empty.

4 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Verifying the mounting kit parts
Verify that the server mounting kit includes the parts listed in table that follows.

Table 5 Mounting kit parts

Component Use
- -
2 universal rail assemblies Attach back to front on either side between
(consists of slide rails for connection to the cabinet channels
cabinet and inner rails for connection to
server)

Four Phillips pan-head 8-32 x 0.35 in screws Stabilize the server and rail mounting

1U bezel (application specific) Covers front of server in cabinet

CL4887

You need a # 2 Phillips-head screwdriver to complete the installation of the rails and
server.

Adjusting the rail assemblies for the cabinet channel holes


The rail assemblies ship with round alignment posts at the end of the rails for cabinet
channels (NEMA rails) with round holes. If your cabinet has channels with square holes,
switch the rail alignment posts to square posts.

Verifying the mounting kit parts 5


Switching rail alignment posts
On each end of each rail assembly, switch the alignment post assembly using the
procedure that follows. Refer to Figure 1 on page 6 while performing the procedure.
Procedure
1. Remove the screw that secures the alignment post assembly.
2. Push the plastic tab on the alignment post assembly up or down, depending on the
rail end, and hold the tab in.
3. Rotate the alignment post assembly either clockwise to switch from round posts to
square posts or counter clockwise to switch from square posts to round posts until
the assembly clicks into place.
4. Secure the alignment post assembly in place with the screw that you removed.

The screw goes in the hole opposite the hole from which you removed it.

Figure 1 Switching from round rail alignment posts to square alignment posts

1 2 3 4

1 2 3 4

CL4951

6 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Removing inner rails from the rail assemblies
Perform the procedure that follows on each rail assembly. Refer to Figure 2 on page 7
while performing the procedure.
Procedure
1. Slide the inner rail out from the slide rail as far as possible.
2. On the inner rail, slide the blue disconnect tab forward to release the inner rail from
the slide rail.
3. Slide the inner rail completely out of the slide rail.
Figure 2 Removing the inner rail from the slide rail

1 2

CL4883

Attaching the inner rails to the server


Attach an inner rail to each side of the server by performing the procedure that follows for
each rail. Refer to Figure 3 on page 8 while performing the procedure.
Procedure
1. With the flat side of the inner rail facing the side of the server, align the large end of
the rail notches of the inner rail with the connection studs on the server and push the
inner rail onto the connection studs.
2. Slide the inner rail forward along the server until the studs fit securely into the small
end of the rail notches.
An audible click indicates that the rail is secure.

Removing inner rails from the rail assemblies 7


Figure 3 Attaching an inner rail to the server

1 2

CL4961

Installing the slide rails in the cabinet


The universal rail assemblies for this server support cabinets in which the front and rear
mounting channels are 24 inches to 34 inches apart. Each assembly contains a right and
a left slide rail.
Install each slide rail in the cabinet using the procedure that follows.
Procedure
1. From the front of the cabinet, align rail alignment posts with the rear channel holes for
the selected 1 U (1.75 in) cabinet space for the server, and insert the alignment posts
securely into the holes (Figure 4 on page 9).
An audible click indicates that the connection is secure.

8 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Figure 4 Inserting rail alignment posts into rear channel holes

CL5090

2. Pull the slide rail forward so the front alignment posts go securely into the holes on
the front channel (Figure 5 on page 9).
An audible click indicates that the connection is secure.
Figure 5 Inserting rail alignment posts into front channel holes

CL5091

3. Secure the rail to the rear channel with a small stabilizer screw (Figure 6 on page
10).

Installing the slide rails in the cabinet 9


Figure 6 Installing stabilizer screws

CL4854

Installing the server on the rails in the cabinet

The enclosure is heavy and should be installed into or removed from a rack by two
people. To avoid personal injury and/or damage to the equipment, do not attempt to lift
and install the enclosure into a rack without a mechanical lift and/or help from another
person.
L’armoire étant lourde, sa mise en place sur une rampe nécessite deux personnes. Afin
de ne pas vous blesser et/ou endommager le matériel, n’essayez pas de soulever et
d’installer l’armoire sur une rampe sans avoir recours à un relevage mécanique et/ou à
l’aide d’une autre personne.
Das Gehäuse ist schwer und sollte nur von zwei Personen in einem Rack installiert
werden. Zur Vermeidung von körperlichen Verletzungen und/oder der Beschädigung des
Gerätes, bitte das Gehäuse nicht ohne die Hilfe einer zweiten Person anheben und
einbauen.
Il contenitore è pesante e dev'essere installato nel rack da due persone. Per evitare
danni personali e/o all’apparecchiatura, non tentare di sollevare ed installare in un rack
il contenitore senza un sollevatore meccanico e/o l’aiuto di un’altra persona.
Debido a su considerable peso, la instalación del compartimento en el bastidor deben
realizarla siempre dos personas. Para evitar daños personales o en el equipo, el
compartimento no debe levantarse ni instalarse en el bastidor sin la ayuda de un
elevador mecánico o de otra persona.

Procedure
1. On each slide rail bring the ball bearing retainer assembly fully to the front, so it rides
onto the security knob (Figure 7 on page 11).

10 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Figure 7 Correct location for ball bearing retainer assembly

CL5092

2. From the front of the cabinet, align the inner rails attached to the server with the white
plastic guide block on the front inside of each slide rail (Figure 8 on page 11).

For clarity Figure 8 on page 11 shows the inner rail without the server attached.

Figure 8 Aligning the inner rail with white plastic guide block

CL5093

3. Slide the server into the cabinet so the inner rails extends over the plastic guide
blocks and the first part of the ball bearing retainer assemblies (Figure 9 on page
12).

For clarity Figure 9 on page 12 shows the inner rail without the server attached.

Installing the server on the rails in the cabinet 11


Figure 9 Inner rail over the first part of ball bearing retainer assembly

CL5094

4. Once the inner rails are properly engaged with the ball bearing retainer assemblies,
push the server into the cabinet until the slide rails are engaged and locked.
An audible click indicates that the slide rails are engaged and locked.
5. On the outside of each rail assembly, slide the blue disconnect tab forward to unlock
the server, and push the server completely into the cabinet (Figure 10 on page 12).
Figure 10 Inserting the server in the cabinet

CL4962

6. To further secure the rail assembly and server in the cabinet, insert and tighten a
small stabilizer screw directly behind each bezel latch (Figure 11 on page 13).

12 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Figure 11 Installing the stabilizer screws

CL4963

Connecting cables
Procedure
1. Plug the power cords into the power supplies and connect these cords to AC power
sources as described in the documentation for your product.
2. Attach any I/O cables as described in the documentation for your product.

Installing the bezel


Bezels are application specific, and may not appear as shown. Bezels may include a key
lock. All bezels include two tabs on either side that you press in to release the bezel and
its latches.
Refer to Figure 12 on page 13 while you perform the procedure that follows.
Procedure
1. Pushing on the ends, not the middle, of the bezel, press the bezel onto the latch
brackets until is snaps into place.
2. If the bezel has a key lock, lock the bezel with the provided key and store the key in a
secure place.
Figure 12 Installing the bezel

CL4964

Connecting cables 13
Powering up the server
Power up the server as described in the documentation for your product.

Maintaining the server


Only certain server components are addable or replaceable as field replaceable units
(FRUs). Should any non-FRU component fail you must replace the entire server. Refer to
your product documentation for information on which components are FRUs.
Before attempting to perform hardware service procedures, review your service contract
because replacement of some server components by unauthorized personnel may void
service warranties.

This document refers to hard drive modules as disk drive assemblies.

Handling field replaceable units (FRUs)


This section describes the precautions that you must take and the general procedures
that you must follow when removing and storing any field replaceable unit (FRU). The only
FRUs in the server are the disk drive assemblies and power supply modules. Depending
on the product in which the server is used, the disk drive assemblies may be hot-
swappable; that is you can replace a disk drive assembly while the server is running. To
determine if disk drive assemblies are hot-swappable, refer to your product
documentation. Regardless of the product in which the server is used, the power supply
modules are hot-swappable; that is you can replace a power supply module while the
server is running.
You should not remove a faulty FRU until you have a replacement available.
When you replace FRUs, you can inadvertently damage the sensitive electronic circuits in
the equipment by simply touching them. Electrostatic charge (ESD) that has accumulated
on your body discharges through the circuits. If the air in the work area is very dry,
running a humidifier in the work area will help decrease the risk of ESD damage. Follow
the procedures below to prevent damage to the equipment.
u Provide enough room to work on the equipment. Clear the work site of any
unnecessary materials or materials that naturally build up electrostatic charge, such
as foam packaging, foam cups, cellophane wrappers, and similar items.
u Do not remove replacement or upgrade FRUs from their antistatic packaging until you
are ready to install them.
u Before you service a server, gather together the ESD kit and all other materials you
will need. Once servicing begins, avoid moving away from the work site; otherwise,
you may build up an electrostatic charge.
u Use the ESD kit when handling any FRU. Use an ESD wristband. To use the ESD
wristband (strap), attach the clip of the wristband to any bare (unpainted) metal on
the server; then put the wristband around your wrist with the metal button against
your skin. If an emergency arises and the ESD kit is not available, follow the
procedures in Emergency procedures (without an ESD kit) on page 14.

Emergency procedures (without an ESD kit)


In an emergency when an ESD kit is not available, use the procedures below to reduce
the possibility of an electrostatic discharge by ensuring that your body and the

14 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


subassembly are at the same electrostatic potential. These procedures are not a
substitute for the use of an ESD kit. Follow them only in the event of an emergency.
u Before touching any FRU, touch a bare (unpainted) metal surface of the cabinet or
server.
u Before removing any FRU from its antistatic bag, place one hand firmly on a bare
metal surface of the server, and at the same time, pick up the FRU while it is still
sealed in the antistatic bag. Once you have done this do not move around the room
or touch other furnishings, personnel, or surfaces until you have installed the FRU.
u When you remove a FRU from the antistatic bag, avoid touching any electronic
components and circuits on it.
u If you must move around the room or touch other surfaces before installing a FRU,
first place the FRU back in the antistatic bag. When you are ready again to install the
FRU, repeat these procedures.

Replacing a disk drive assembly


A disk drive assembly consists of a hard disk drive supplied in special hot-swappable
hard-drive carrier that fits in a disk slot. Disk slots are accessible from the front of the
server. Refer to your product documentation to determine if a disk drive assembly is hot-
swappable.

To maintain proper system cooling, any hard-drive bay without a disk drive assembly or
device installed must be occupied by filler module.

If a disk drive assembly is not hot-swappable, you may lose data when your replace a
disk drive assembly while the system is powered up and I/O is occurring. To determine if
disk drive assemblies are hot-swappable, refer to your product documentation.

Do not turn off or reboot your system while the drive is being formatted. Doing so can
cause a drive failure. Use appropriate ESD precautions, including the use of a grounding
strap, when performing the drive module replacement procedure.

To replace a disk drive assembly, you must perform the tasks below in the order listed.
The rest of the section describes how to perform each task.
1. Review the section on handling disk drive assemblies.
2. Identify the faulted disk drive assembly.
3. Remove the bezel from the server.
4. Replace the fault disk drive assembly.
5. Reinstall the bezel on the server.
Before you replace a disk drive assembly, review the section on handing field replaceable
units (FRUs).

Handling disk drive assemblies


u Do not remove a disk drive filler until you have a replacement disk drive assembly
available to replace it.
u Disk drive assemblies are sensitive to the extreme temperatures that are sometimes
encountered during shipping. We recommend that you leave the new disk drive
assembly in its shipping material and expose the package to ambient temperature for

Replacing a disk drive assembly 15


at least four hours before attempting to use the new disk drive assemblies in your
system.
u Avoid touching any exposed electronic components and circuits on the disk drive
assembly.
u Do not stack disk drive assemblies upon one another, or place them on hard
surfaces.
u When installing multiple disk drive assemblies in a powered up system, wait at least
6 seconds before sliding the next disk drive assembly into position.

Identifying the faulted disk drive assembly


Consult your product documentation on how to identify a faulted disk assembly in the
server. A faulted disk drive assembly may have an amber LED indicator on its carrier,
which is visible when you remove the server’s bezel.

Removing the bezel


The front of the server may be covered by a bezel. Bezels are application specific, and
may not appear as shown. Bezels may include a key lock. If the server has a bezel,
remove it.
Refer to Figure 13 on page 16 while performing the procedure that follows.
Procedure
1. If the bezel has a key lock, unlock the bezel with the provided key.
2. Press the two tabs on either side of the bezel to release the bezel from its latches, and
pull the bezel off the latches.
Figure 13 Removing the bezel

CL4965

Replacing the faulted disk drive assembly


Procedure
1. Attach an ESD wristband to your wrist and the server chassis.
2. Remove the faulted disk drive assembly (Figure 14 on page 17):
a. Press the green button on the left side of the disk drive assembly to unlock the
module’s lever.
b. Pull the lever open and slide the disk drive assembly from the server.

16 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Figure 14 Removing the faulted disk drive assembly

A
B

CL5276

3. Unpack the replacement disk drive assembly and save the packing material for
returning the faulted disk drive assembly.
4. Install the replacement disk drive assembly (Figure 15 on page 17):
a. With the lever on the replacement disk drive assembly in the fully open position
(green button to the right), slide the module into the server.
b. When the lever begins to close by itself, push on the lever to lock it into place.
Figure 15 Installing the replacement disk drive assembly

CL5277

5. Remove and store the ESD wristband.

Reinstalling the bezel


If a bezel covered the front of the server, reinstall the bezel using the procedure that
follows. Refer to Figure 16 on page 18 while performing the procedure.
Procedure
1. Pushing on the ends, not the middle, of the bezel, press the bezel onto the latch
brackets until is snaps into place.
2. If the bezel has a key lock, lock the bezel with the provided key and store the key in a
secure place.

Reinstalling the bezel 17


Figure 16 Installing the bezel

CL4964

Replacing a power supply module


The power supply modules are accessible from the rear of the server. Before you begin
the procedure below to replace a faulted power supply module, review the section on
handling field replaceable units (FRUs).
Procedure
1. At the rear of the server, locate the power supply module with an amber LED indicator.
2. Undo the retaining clip securing the module’s AC power cord, and unplug the cord.
3. Push the green latch on the faulted power supply module to the left while pulling the
supply out of the server by its handle (Figure 17 on page 18).
Figure 17 Removing a faulted power supply module

CL4968

4. Unpack the replacement power supply and save the packing material for returning the
faulted power supply.
5. Insert the replacement power supply module into the power supply cage and push the
module all the way until it clicks into place (Figure 18 on page 19).

18 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Figure 18 Installing a replacement power supply module

CL4969

6. Plug in the module’s AC power cord and fasten the retaining clip to secure the cord.

Replacing the server


Replacement of non-FRU server components by unauthorized personnel may void service
warranties. Refer to your product documentation for information on which components
are FRUs. Should any non-FRU component fail you must replace the entire server.
To replace the server perform the tasks below in the order listed. The rest of this section
describes how to perform each task.
1. Power off the server.
2. Disconnect the cables from the server.
3. Remove the bezel from the server.
4. Remove the server from the cabinet.
5. Remove the inner rails from the server.
6. Unpack the replacement server.
7. Attach the inner rails to the replacement server.
8. Install the replacement server on the rails in the cabinet.
9. Reconnect the cables that you removed from the original server to the replacement
server.
10. Reinstall the bezel on the replacement server.
11. Power up the replacement server.

Powering off the server


Before removing the server from the cabinet, power it off as described in the
documentation for your product.

Replacing the server 19


Disconnecting cables from the server
Procedure
1. Unplug all power cords and I/O cables from the back of the server.
2. Label each cord and cable so you can easily identify them when you need to plug
them into the replacement server.

Removing the bezel


The front of the server may be covered by a bezel. Bezels are application specific, and
may not appear as shown. Bezels may include a key lock. If the server has a bezel,
remove it.
Refer to Figure 19 on page 20 while performing the procedure that follows.
Procedure
1. If the bezel has a key lock, unlock the bezel with the provided key.
2. Press the two tabs on either side of the bezel to release the bezel from its latches, and
pull the bezel off the latches.
Figure 19 Removing the bezel

CL4965

20 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Removing the server from the cabinet

The enclosure is heavy and should be installed into or removed from a rack by two
people. To avoid personal injury and/or damage to the equipment, do not attempt to lift
and install the enclosure into a rack without a mechanical lift and/or help from another
person.
L’armoire étant lourde, sa mise en place sur une rampe nécessite deux personnes. Afin
de ne pas vous blesser et/ou endommager le matériel, n’essayez pas de soulever et
d’installer l’armoire sur une rampe sans avoir recours à un relevage mécanique et/ou à
l’aide d’une autre personne.
Das Gehäuse ist schwer und sollte nur von zwei Personen in einem Rack installiert
werden. Zur Vermeidung von körperlichen Verletzungen und/oder der Beschädigung des
Gerätes, bitte das Gehäuse nicht ohne die Hilfe einer zweiten Person anheben und
einbauen.
Il contenitore è pesante e dev'essere installato nel rack da due persone. Per evitare
danni personali e/o all’apparecchiatura, non tentare di sollevare ed installare in un rack
il contenitore senza un sollevatore meccanico e/o l’aiuto di un’altra persona.
Debido a su considerable peso, la instalación del compartimento en el bastidor deben
realizarla siempre dos personas. Para evitar daños personales o en el equipo, el
compartimento no debe levantarse ni instalarse en el bastidor sin la ayuda de un
elevador mecánico o de otra persona.

Procedure
1. Remove the stabilizing screw behind the latch bracket on each side (Figure 20 on
page 21).
Figure 20 Removing the stabilizer screws

CL4963

2. Pull the server forward until it locks in place (Figure 21 on page 22).

Removing the server from the cabinet 21


Figure 21 Sliding server out of the cabinet to the locked position

CL4970

3. Slide the blue disconnect tabs forward to release the inner rails from the slide rails
(Figure 22 on page 22).

Once you release the server from the inner rails, you must support the full weight of
the server.

4. Being prepared to support the full weight of the server, slowly pull the server forward
and remove it from the cabinet (Figure 22 on page 22).
Figure 22 Releasing the inner rail locks and removing the server from the cabinet

CL4971

Removing the inner rails from the server


Use the procedure that follows to remove each inner rail from the server. Refer to Figure
23 on page 23 while performing the procedure.

22 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Procedure
1. On the middle of the inner rail, push in and hold the metal latch, and push the rail
backward to release the connection studs from the small end of the rail notches.
2. When the connections studs are in the large end of the rail notches, release the metal
latch and pull the inner rail away from the server.
Figure 23 Releasing the inner rails from the server

1 2

CL4972

Unpacking a part
Procedure
1. Attach an ESD wristband to your wrist and the enclosure in which you are installing
the part.
2. Unpack the part and place it on a static-free surface.
3. If the part is a replacement for a faulted part, save the packing material to return the
faulted part.

Attaching the inner rails to the server


Attach an inner rail to each side of the server by performing the procedure that follows for
each rail. Refer to Figure 24 on page 24 while performing the procedure.

Unpacking a part 23
Procedure
1. With the flat side of the inner rail facing the side of the server, align the large end of
the rail notches of the inner rail with the connection studs on the server and push the
inner rail onto the connection studs.
2. Slide the inner rail forward along the server until the studs fit securely into the small
end of the rail notches.
An audible click indicates that the rail is secure.
Figure 24 Attaching an inner rail to the server

1 2

CL4961

24 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Installing the server on the rails in the cabinet

The enclosure is heavy and should be installed into or removed from a rack by two
people. To avoid personal injury and/or damage to the equipment, do not attempt to lift
and install the enclosure into a rack without a mechanical lift and/or help from another
person.
L’armoire étant lourde, sa mise en place sur une rampe nécessite deux personnes. Afin
de ne pas vous blesser et/ou endommager le matériel, n’essayez pas de soulever et
d’installer l’armoire sur une rampe sans avoir recours à un relevage mécanique et/ou à
l’aide d’une autre personne.
Das Gehäuse ist schwer und sollte nur von zwei Personen in einem Rack installiert
werden. Zur Vermeidung von körperlichen Verletzungen und/oder der Beschädigung des
Gerätes, bitte das Gehäuse nicht ohne die Hilfe einer zweiten Person anheben und
einbauen.
Il contenitore è pesante e dev'essere installato nel rack da due persone. Per evitare
danni personali e/o all’apparecchiatura, non tentare di sollevare ed installare in un rack
il contenitore senza un sollevatore meccanico e/o l’aiuto di un’altra persona.
Debido a su considerable peso, la instalación del compartimento en el bastidor deben
realizarla siempre dos personas. Para evitar daños personales o en el equipo, el
compartimento no debe levantarse ni instalarse en el bastidor sin la ayuda de un
elevador mecánico o de otra persona.

Procedure
1. On each slide rail bring the ball bearing retainer assembly fully to the front, so it rides
onto the security knob (Figure 25 on page 25).
Figure 25 Correct location for ball bearing retainer assembly

CL5092

2. From the front of the cabinet, align the inner rails attached to the server with the white
plastic guide block on the front inside of each slide rail (Figure 26 on page 26).

Installing the server on the rails in the cabinet 25


For clarity Figure 26 on page 26 shows the inner rail without the server attached.

Figure 26 Aligning the inner rail with white plastic guide block

CL5093

3. Slide the server into the cabinet so the inner rails extends over the plastic guide
blocks and the first part of the ball bearing retainer assemblies (Figure 27 on page
26).

For clarity Figure 27 on page 26 shows the inner rail without the server attached.

Figure 27 Inner rail over the first part of ball bearing retainer assembly

CL5094

4. Once the inner rails are properly engaged with the ball bearing retainer assemblies,
push the server into the cabinet until the slide rails are engaged and locked.
An audible click indicates that the slide rails are engaged and locked.
5. On the outside of each rail assembly, slide the blue disconnect tab forward to unlock
the server, and push the server completely into the cabinet (Figure 28 on page 27).

26 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Figure 28 Inserting the server in the cabinet

CL4962

6. To further secure the rail assembly and server in the cabinet, insert and tighten a
small stabilizer screw directly behind each bezel latch (Figure 29 on page 27).
Figure 29 Installing the stabilizer screws

CL4963

Reconnecting cables
Plug all power and I/O cables that you removed from the original server into the back of
the replacement server.

Reinstalling the bezel


If a bezel covered the front of the server, reinstall the bezel using the procedure that
follows. Refer to Figure 30 on page 28 while performing the procedure.
Procedure
1. Pushing on the ends, not the middle, of the bezel, press the bezel onto the latch
brackets until is snaps into place.
2. If the bezel has a key lock, lock the bezel with the provided key and store the key in a
secure place.

Reconnecting cables 27
Figure 30 Installing the bezel

CL4964

Powering up the server


Power up the server as described in the documentation for your product.

Removing the slide rails from the cabinet


If you ever need to remove the rails from the cabinet, use the procedure that follows.
Procedure
1. On each rail, remove the small stabilizer screw that secures the rail to the rear
channel (Figure 31 on page 28).
Figure 31 Removing the rear stabilizing screws

CL4854

2. Release each rail from the channels (Figure 32 on page 29):


a. At each rail end, push and hold the alignment posts together.
b. Slide the rail out of the channel, and remove it from the cabinet.

28 EMC SVR-I1U-1208 Server Installation and Maintenance Guide


Figure 32 Releasing the rail from the cabinet channels

Rear

A B

CL4856

Removing the slide rails from the cabinet 29


Copyright © 2012-2013 EMC Corporation. All rights reserved. Published in USA.

Published June, 2013

EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without
notice.

The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with
respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a
particular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software
license.

EMC², EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries.
All other trademarks used herein are the property of their respective owners.

For the most up-to-date regulatory document for your product line, go to EMC Online Support (https://support.emc.com). For
documentation on EMC Data Domain products, go to the EMC Data Domain Support Portal (https://my.datadomain.com).

30 EMC SVR-I1U-1208 Server Installation and Maintenance Guide