You are on page 1of 28

Cam Switch

Cam Switch
LW39-10 Series
LW39-16 Series
LW39-25 Series
LW39-63 Series
LW39 Series Cam Switch

LW39-16A Series

Refer to page 2 Refer to page 2 Refer to page 2 Refer to page 3 Refer to page 3

LW39-16B Series LW39-16C Series

Refer to page 4 Refer to page 4 Refer to page 4 Refer to page 5 Refer to page 6 Refer to page 6 Refer to page 6

LW39-25 Series

Refer to page 7 Refer to page 7 Refer to page 7 Refer to page 8 Refer to page 8 Refer to page 8

LW39-63 Series LW39-10 Series LW39-63/16

Refer to page 10 Refer to page 10 Refer to page 10 Refer to page 10 Refer to page 12 Refer to page 12
Catalogue

LW39 Series Cam Switch


Technical Data 01

LW39-16A Series 02

LW39-16B Series 04

LW39-16C Series 06

LW39-25 Series 07

LW39-63 Series 10

LW39-10 Series 12

LW39-63/10 Series 12

Model number 13

Code number of fixing angle 14

Code number of contact 16

Code number of escutcheon plates 17

Examples 18

24
Order notice
LW39 Series Cam Switch

Technical data
Working environment Adopted standards
Altitude no more than 2000M
Ambient temperature: - 25°C ----- + 55°C
GB/T14048.1 GB14048.3 GB14048.5
Relative humidity no more than 90% IEC60947-1 IEC60947-3 IEC60947-5-1 VDE0660
Installation group: III
Pollution degree: 3

Technical data
Model
Rated insulation voltage Ui GB/T14048.1 V 400 690 690 690
Conventional thermal current Ith GB/T14048.1 A 10 16 25 63
Power-frequency withstand voltage GB/T14048.1 V 2500 2500 2500 2500
Rated operational current le
AC-21 switching of resistance loads GB14048.3 A 10 16 25 63
AC-15 switching of control devices,contactors,valves,etc
GB14048.5
28
COS =0.4 24V A 10 16 25
25
48V A 5 8 22
22
110V A 3 5 18
16
220V A 2 3 12
8
380V A 1.2 1.8 8
AC-3 Direct-on-line starting,star-delta starting
GB14048.3 refer to appendix A
3 phase 3 pole 380V KW 1.5 3 5.5 15

AC-4 Direct-on-line starting,reversing,


plugging an inching
GB14048.3 refer to appendix A
3 phase 3 pole 380V KW 0.37 1.2 4 6
Rated operational current le
DC-21 switching of resistance loads GB14048.3
No of series contacts 1 2 3 4
24 48 70 95 A 10 16 25
48 60 95 110 A 6 12 22
Voltage V 110 220 300 A 0.56 1 5
220 440 A 0.24 0.4 2.5
440 A 0.1 0.27 1.25
DC-13 switching of control devices,contactors,valves,etc
T=300ms GB14048.5
No of series contacts 1 2 3 4
24 48 70 95 A 8 12 20
48 60 95 110 A 1.2 2 8
Voltage V 110 220 300 A 0.25 0.4 2.5
220 440 A 0.12 0.2 1.25
440 A 0.1 0.5
Electrical life (AC) x 10000 20 20 20 10
Electrical life (DC) x 10000 10 10 10
Mechanical life x 10000 30 30 30 30

1
LW39-16
LW39-16 series cam switch is suitable for numeric controlled machines,program controlled machines and electric devices.
It is used for controlling,lighting,protection,signal,program selection and measurement selection of voltage and current

LW39-16A series
Conventional thermal current is 16A.
Operation positions are 30 45 90
1--12 layers with 2 pairs of contacts each layer
Remark: If operational voltage is under 24V,operational current is under 100mA,please note in the order.
Normal style LW39-16A
Operation position 12 layers Max Handle :A---G
monting panel:1--3mm

layer number

1 layer added as spring return switch fixing hole drawing

Model number refer to page 13

Key-lock device LW39-16A YS


Operation position 12 layers Max Handle :designation

monting panel:1--3mm

L = 45 + 12 X layer number

1 layer added as spring return switch fixing hole drawing

Model number refer to page 13


The handle is locked as key taken away in any position.Please note in order if you have other request.

Key-lock on panel device LW39-16A YM


Operation position 12 layers Max Handle:A,B,C,D
monting panel:1--3mm

L = 44.5 + 12 X layer number


1 layer added as spring return switch fixing hole drawing

Model number refer to page 13


The handle is locked as key taken away in any position.Please note in order if you have other request.

2
LW39 Series Cam Switch

Control and indicator device LW39-16A DM


Operation position 12 layers Max Handle :A---G
monting panel:1--3mm indicator(green) indicator(red)

pre--on
post-on
on
pre--off
post-off

off

layer number

1 layer added as spring return switch fixing hole drawing

Model number refer to page 13

Rectangular add-on escutcheon plate LW39-16A P


Operation position 12 layers Max Handle :A---G
monting panel:1--3mm

layer number
1 layer added as spring return switch
fixing hole drawing

Model number refer to page 13

Handle for LW39-16A ( product use Ak handle if no special requirement )

Model

Handle

48.5 51.7
22

Dimension
22

22

33
33 33 33

Model

Handle

72

Dimension
38

33 33.5 72

3
LW39-16B series
Conventional thermal current is 16A,covert wiring,safe to touch
Operation positions are 30 45 60 90
1--12 layers with 2 pairs of contacts each layer,suggest no more than 8 layers.
Remark: If operational voltage is under 24V,operational current is under 100mA,please note in the order.

Normal style LW39-16B


Operation position 12 layers Max,suggest no more than 8 layers Handle :A,B,D,G

monting panel:1--3mm

layer number
1 layer added as spring return switch fixing hole drawing

Model number refer to page 13

Base mounting(four hole) LW39-16B M


Operation position 12 layers Max, suggest no more than 8 layers Handle :A,B,D,G

layer number

fixing hole drawing

Model number refer to page 13

Reset as handle be pulled out LW39-16B ZL


Code of 12 layers Max suggest no more than 8 layers Handle :A,B,D,G
operation position or

monting panel:1--3mm

layer number
fixing hole drawing

Model number refer to page 13


Remark: "9GC" denotes: "B1" denotes

4
LW39 Series Cam Switch

Rectangular add-on escutcheon plate LW39-16B P


Operation position 12 layers Max Handle :A,B,D,G
monting panel:1--3mm

layer number
fixing hole drawing

Model number refer to page 13

Handle for LW39-16B ( product use Ak handle if no special request )


Model

Handle

56
36.5 44
25

Dimension
25

22

35
27
27 27
56

5
LW39-16C series
Conventional thermal current is 16A,covert wiring,safe to touch
Operation positions are 30 45 60 90
1--12 layers with 2 pairs of contacts each layer,suggest no more than 8 layers.
Remark: If operational voltage is under 24V,operational current is under 100mA,please note in the order.

Normal style LW39-16C


Operation position 12 layers max, suggest no more than 8 layers Handle :designation

monting panel:1--3mm

layer number
fixing hole drawing

Model number refer to page 13

Key-lock device LW39-16C YS


Operation position 12 layers maxsuggest no more than 8 layers No handle

monting panel:1--3mm

layer number

fixing hole drawing

Model number refer to page 13


The switch is locked as key taken away in any position.Please note in order if you have other request.

Single hole mounting /no front panel LW39-16C U


Operation position 12 layers maxsuggest no more than 8 layers Handle:designation
monting panel:1--3mm
APT APT APT APT
R
A P T

APT APT APT

layer number
fixing hole drawing

Model number refer to page 13

6
LW39 Series Cam Switch

LW39-25 series,special for direct current operation environment

Conventional thermal current is 25 A,covert wiring,safe to touch


Operation positions are 30 45 90
This series can meet demand on different kinds of contacts throught various cams.
Contacts are silver alloy.

Normal style LW39-25


Operation position 12 layers Max Handle :A---G

monting panel:1--3mm

layer number
fixing hole drawing

Model number refer to page 13

Key-lock device LW39-25 YS


Operation position 12 layers Max Handle :designation
monting panel:1--3mm

Momentary layer number(1--12)

Spring return layer number(1--10)


fixing hole drawing

Model number refer to page 13


The handle is locked as key taken away in any position.Please note in order if you have other request.

Key-lock on panel device LW39-25 YM


Operation position 12 layers Max Handle : A,B,C,D
2

6
6
2

UP
4

8
8
4

APT R
APT

layer number

1 layer added as spring return switch


fixing hole drawing

Model number refer to page 13


The handle is locked as key taken away in any position.Please note in order if you have other request.

7
Control and indicator device LW39-25 DM
Operation position 11 layers Max Handle : A---G
monting panel:1--3mm
indicator(green) indicator(red)

layer number
1 layer added as spring return switch fixing hole drawing

Model number refer to page 13

Rectangular add-on escutcheon plate LW39-25 P


Operation position 12 layers Max Handle : A---G

monting panel:1--3mm

layer number
1 layer added as spring return switch fixing hole drawing

Model number refer to page 13

Base mounting (two hole) or track mounting LW39-25 M


Operation position 8 layers Max Handle : A---G

layer number (1--6)


Rail installation
layer number (1--5)
fixing hole drawing

Model number refer to page 13

8
LW39 Series Cam Switch

Handle for LW39-25 ( product use Ak handle if no special request )

Model

Handle

48.5 51.7

22
22

22
Dimension
33
33 33 33

Model

Handle

72

Dimension

38
33 33.5 72

9
LW39-63 series on/off switch

Conventional thermal current is 63A


Operation positions are 30 45 60 90
1--8 layers with 2 pairs of contacts each layer

Remark : please refer the thickness of fixing panel in your order.


For example LW39- 63 / Gr40.means thickness of this fixing panel is 40mm

Normal style LW39-63


Operation position 8 layers Max Handle : Ak,Gk

monting panel:1--4mm

layer number
22mm added as spring return switch fixing hole drawing

Model number refer to page 13

Key-lock device LW39-63 YS


Operation position 8 layers Max Handle : designation
monting panel:1--3mm
APT

layer number
1 layer added as spring return switch fixing hole drawing

Model number
The handle is locked as key taken away in any position.Please note in order if you have other request. refer to page 13

Control and indicator device LW39-63 DM


Operation position 8 layers Max Handle : Ak,Gk
monting panel:1--3mm indicator(green) indicator(red)

layer number
fixing hole drawing

Model number refer to page 13

10
LW39 Series Cam Switch

Rectangular add-on escutcheon plate LW39-63 P


Operation position 8 layers Max Handle : Ak,Gk

monting panel:1--3mm

layer number
20mm added as spring return switch fixing hole drawing

Model number refer to page 13

Handle for LW39-25 ( product use Ak handle if no special requirement )

Model

Handle

72
50
27.5

Dimension
38

36 72

11
LW39-10 series

Conventional thermal current is 25 A,covert wiring,safe to touch


Operation positions are 30 45 90
This series can meet demandes on different kinds of contacts throught various cams.
Contacts are silver alloy.

Single hole mounting LW39-10


Operation position 8 layers Max Handle : designation

monting panel:1--3mm

layer number fixing hole drawing

Model number refer to page 13

12
Explaination for selection

Please select model number of LW39 series cam switches in following 3 ways:
(1).select from our common used model number.
(2).fill detail model unmber according to explanation .
(3).fill order notice in last page,we will confirm exact model number with you.

LW39-10 - - /

Code number of escutcheon plate(refer to page 20)


Numbers of layer
Code number of contact(refer to page 19)
Code number of fixing angle
Code number of function

LW39-16 - - /

Code number of escutcheon plate(refer to page 20)


Code number of handle(refer to page 7-9)
Code number of voltage
"23"--24V;"26"--110V;"28"--DC220V;"31"--AC220V
Numbers of layer
Code number of contact
Code number of fixing angle
Code number of function

LW39-25 - - /

Code number of escutcheon plate(refer to page 20)


Code number of handle(refer to page 7-9)
Code number of voltage
"23"--24V;"26"--110V;"28"--DC220V;"31"--AC220V
Numbers of layer
Code number of contact
Code number of fixing angle
Code number of function

LW39-63 - - /

Code number of escutcheon plate(refer to page 20)


Code number of handle(refer to page 7-9)
Code number of voltage
"23"--24V;"26"--110V;"28"--DC220V;"31"--AC220V
Numbers of layer
Code number of contact
Code number of fixing angle
Code number of function

13
Code number of fixing angle

(1)Momentary

Angle Series Code number for each position Example

OA B
LW39-10 LW39-16 K C 3KC :30 angle
30 J D start from K clockwise to C
LW39-25 LW39-63 I E
HGF totally including K,O,A,B,C positiones.

O A B "4OB" :45 angle


LW39-10 LW39-16
45 G C start from O clockwise to B
LW39-25 LW39-63 totally including O,A,B,C positiones.
F D
E

OA B "6KE" :60 angle


K C
60 LW39-16B LW39-16C LW39-63 J D start from K clockwise to E
I E totally including K,A,C,E positiones.
HGF

O A B 9GC :90 angle


LW39-10 LW39-16
90 G C start from G clockwise to C
LW39-25 LW39-63 totally including G,A,,C positiones.
F D
E

Explaination :

Finished position
Start position
Angle:"3"---30 ;"4"---45 ; "6"---60 ; "9"---90 .

14
LW39 Series Cam Switch

2 Spring return : please select code number of operation position for spring return style from following:

Code number Operation position


A1 0 30 Y*
A2 0 45 Y Y Y Y
B1 -30 0 30 Y*
B2 -45 0 45 Y Y Y Y
BA -90 -45 0 45 90 Y Y Y
BC -45 0 0 45 Y Y
BD -30 0 0 30 Y*
Z1 -135 -90 0 45 Y Y Y Y
ZA -90 -45 0 45 90 Y Y Y Y
ZB -90 -45 0 45 Y Y Y Y
ZC -45 0 45 90 Y Y Y Y
ZD -90 0 45 Y Y Y Y
ZE 0 45 90 Y Y Y Y
ZF -45 0 45 Y Y Y Y
ZG -45 0 45 Y Y Y Y
ZK -45 0 45 90 Y Y Y Y
W -120 -90 0 30 Y* Y*
WA -90 0 30 Y*
WB -30 0 90 Y*
WR -120 -90 0 90 120 Y* Y*
WS -90 0 90 120 Y* Y*
WT -120 -90 0 90 Y* Y*
WU -90 -30 0 30 Y*
WV -90 0 30 90 Y*
WW -90 -30 0 30 90 Y*

Remark

1." " means max of the contact layer is 3;


*
2."Y" means we can offer switch as corresponding operation position

15
LW39 Series Cam Switch

Code number of contact

1.One completed code number of contact is corresponding to only one terminal marking.

2.Each contact corresponding to a binary code,plus this 4 binary codes in one layer,there will be a hex code.

We use binary code as following: We use hex code as following:

1,2,4,8 1,2,3,4,5,6,7,8,9,A,B,C,D,E,F

3.For example:

Remark : "X" express terminal condition.

Function of switch is up to customer's request.

Contact Binary code Position # 1 Position # 2 Position # 3 Position # 4

1-2 1
3-4 2
Layer#1
5-6 4
7-8 8
9-10 1
Layer#2 11-12 2
13-14 4
15-16 8

Layer#1 1+4=5 0 4 0
Layer#2 4 1+2+8=B 0 2+4=6

Complete code number of contact

16
Code number of escutcheon plates

Code number of escutcheon plates can be choosen from following standard letterings,special letterings upto request.
Tolerant escutcheon plate will be offered as no special request.
1. Tolerant rule of letterings:

(1). "0" marked in the position no contact cut in,"1","2","3"...will be marked one by one on two sides of "0".
Special one :"1-0-2" is for 3 position switch. For example:

(2). "1","2","3"...is marked one by one from left to right when each position has contact cut in. For example:

2. Standard letterings:

Remark : "A" nobed code is applicable to LW39-10,LW39-16A,LW39-25,LW39-63


"B" nobed code is applicable to LW39-16B,LW39-16C

30 Switching

45 Switching

90 Switching and pre-on/off switching

60 Switching

17
LW39 Series Cam Switch

Examples

On/off switches Double-throw switches without "off"


Contact 0 1 Contact 1 2
Layer Model Layer Model

layer#1
1-2 1-2
3-4 LW39- - -02/1 layer#1
3-4 LW39- - -11/1
layer#2
5-6 5-6
7-8 LW39- - -04/2 layer#2
7-8 LW39- - -22/2
layer#3
9-10 9-10
11-12 LW39- - -06/3 layer#3
11-12 LW39- - -33/3
13-14 13-14
layer#4
15-16 LW39- - -08/4 layer#4 15-16 LW39- - -44/4
layer#5
17-18 17-18
19-20 LW39- - -0A/5 layer#5 19-20 LW39- - -55/5
21-22 21-22
layer#6
23-24 LW39- - -0C/6 layer#6 23-24 LW39- - -66/6
25-26 25-26
layer#7
27-28 LW39- - -0E/7 layer#7 27-28 LW39- - -77/7
layer#8
29-30 29-30
31-32 LW39- - -0G/8 layer#8
31-32 LW39- - -88/8
33-34 33-34
layer#9
35-36 LW39- - -0I/9 layer#9 35-36 LW39- - -99/9
layer#10
37-38 layer#10
37-38
39-40 LW39- - -0K/10 39-40 LW39- - -AA/10

Double-throw switches without "off" Double-throw switches with center "off"


Contact 1 2 Contact 1 0 2
Layer Model Layer o Model
0
1-2 layer#1 1-2
layer#1
3-4 LW39- - -11J/1 3-4 LW39- - -101/1
5-6 layer#2 5-6
layer#2
7-8 LW39- - -22J/2 7-8 LW39- - -202/2
9-10 layer#3
9-10
layer#3
11-12 LW39- - -33J/3 11-12 LW39- - -303/3
13-14 layer#4
13-14
layer#4
15-16 LW39- - -44J/4 15-16 LW39- - -404/4
17-18 layer#5
17-18
layer#5
19-20 LW39- - -55J/5 19-20 LW39- - -505/5
21-22 layer#6
21-22
layer#6
23-24 LW39- - -66J/6 23-24 LW39- - -606/6
25-26 layer#7
25-26
layer#7
27-28 LW39- - -77J/7 27-28 LW39- - -707/7
29-30 layer#8 29-30
layer#8
31-32 LW39- - -88J/8 31-32 LW39- - -808/8
33-34 layer#9
33-34
layer#9
35-36 LW39- - -99J/9 35-36 LW39- - -909/9
37-38 layer#10
37-38
layer#10
39-40 LW39- - -AAJ/10 39-40 LW39- - -A0A/10

18
Double-throw switches with center "off" Multi-step switches without "off"
Layer Contact 1 0 2 Model
Contact 1 2 3
Layer Model
0o
layer#1 1-2 layer#1 1-2
3-4 LW39- - -101J/1 3-4
layer#2 5-6 layer#2 5-6 LW39- - -111J/2
7-8 LW39- - -202J/2 7-8
layer#3 9-10 layer#3
9-10
11-12 LW39- - -303J/3 11-12 LW39- - -222J/3
layer#4 13-14 layer#4
13-14
15-16 LW39- - -404J/4 15-16
layer#5 17-18 layer#5
17-18 LW39- - -333J/5
19-20 LW39- - -505J/5 19-20
layer#6 21-22 layer#6
21-22
23-24 LW39- - -606J/6 23-24 LW39- - -444J/6
layer#7 25-26 layer#7
25-26
27-28 LW39- - -707J/7 27-28
layer#8 29-30 layer#8 29-30 LW39- - -555J/8
31-32 LW39- - -808J/8 31-32
layer#9 33-34 layer#9
33-34
35-36 LW39- - -909J/9 35-36 LW39- - -666J/9
layer#10 37-38
39-40 LW39- - -A0AJ/10

Multi-step switches without "off" Multi-step switches without "off"


Contact 1 2 3 4 Layer Contact 1 2 3 4 5 Model
Layer Model

layer#1 1-2 layer#1 1-2


3-4 3-4
layer#2 5-6 layer#2 5-6
7-8 LW39- - -1111J/2 7-8
layer#3
9-10 layer#3 9-10 LW39- - -1 5J/3
11-12 11-12
layer#4
13-14 layer#4 13-14
15-16 LW39- - -2222J/4 15-16
layer#5
17-18 layer#5 17-18
19-20 19-20 LW39- - -2 5J/5
layer#6
21-22 layer#6 21-22
23-24 LW39- - -3333J/6 23-24
layer#7
25-26 layer#7 25-26
27-28 27-28
layer#8 29-30 layer#8 29-30 LW39- - -3 5J/8
31-32 LW39- - -4444J/8 31-32
layer#9
33-34 layer#9 33-34
35-36 35-36
layer#10
37-38 layer#10 37-38
39-40 LW39- - -5555J/10 39-40 LW39- - -4 5J/10
layer#11
41-42
43-44
45-46
layer#12
47-48 LW39- - -6666J/12

19
LW39 Series Cam Switch
Changeover switches for voltmeter

Zero position,Line N,threee phase voltage switching meas Zero position,Line N,threee phase voltage,three line voltage switching meas

LW39-16A-YH1/3 LW39-16A-YH5/4
LW39-16B-YH1/3 LW39-16B-YH5/4
LW39-25-YH1/3 LW39-25-YH5/4
A74 B102 0 A B C A57 B4-1 CA BC AB O AN BN CN
o o o o
0 90 180 270 -135o -90o -45o 0o 45o 90o 135o
A 1-2 C 1-2
C 3-4 B 3-4
B 5-6 5-6
A 7-8
N 9-10 9-10
11-12
N 13-14
15-16

Zero position,No line N,threee line voltage switching meas

LW39-16A-YH2/3
LW39-16B-YH2/3 Zero position,Line N,voltage between two three-phased power supply switching meas
LW39-25-YH2/3 LW39-16A-YH6/4
A75 B103 O AB BC CA LW39-16B-YH6/4
0o 90o 180o 270o LW39-25-YH6/4
B 1-2 CA BC AB O AB BC CA
-135 -90o -45o 0o 45o 90o 135
o o

A 5-6 2A 1-2
7-8 1A 3-4
2B 5-6
C 11-12 1C 7-8
9-10
11-12
2C 13-14
No zero position,Line N,threee phase voltage switching meas
1B 15-16
LW39-16A-YH3/3
LW39-16B-YH3/3
LW39-25-YH3/3
A72 B100 A B C
o o o
-90 0 90 Zero position,Line N,one phase voltage and three phase voltage switching meas

A 1-2 LW39-16A-YH8/4
C 3-4 LW39-16B-YH8/4
B 5-6 LW39-25-YH8/4
A57 B4-1 CA BC AB O AN
N 9-10 -135o -90o -45o 0o 45o
C 1-2
B 3-4
5-6
A 7-8
No zero position,No line N,threee line voltage switching meas
9-10
LW39-16A-YH4/2 11-12
LW39-16B-YH4/2 N 13-14
LW39-25-YH4/2 15-16
A73 B101 AB BC CA
-90o 0o 90o
B 1-2
C 3-4

A 5-6
7-8

20
Changeover switches for voltmeter Changeover switches for amperemeter

Zero position,Line N,threee phase voltage switching meas 2 CTS ,Zero position,No line N,threee phase current switching meas

LW39-16A-YH11/2 LW39-16A-LH1/2
LW39-16B-YH11/2 A B C LW39-16B-LH1/2
LW39-25-YH11/2 LW39-25-LH1/2
A74 B102 O A B C A74 B102 O A B C
0o 90o 180o 270o 0o 90o 180o 270o
A 1-2 1-2
B 3-4 3-4
V A
C 5-6 5-6
N 7-8 7-8

Zero position,Line N,threee line voltage switching meas

LW39-16A-YH12/2 3 CTS, No zero position,Line N,threee phase four line current switching meas
LW39-16B-YH12/2 LW39-16A-LH2/4
LW39-25-YH12/2
A B C N LW39-16B-LH2/4
A75 B103 O AB BC CA LW39-25-LH2/4
o o o o
0 90 180 270 O A B C
A 1-2 0o 90o 180o 270o
3-4 1-2
B 5-6 V
3-4
C 7-8 5-6
7-8
A
9-10
No zero position,Line N,threee phase voltage switching meas
11-12
13-14
LW39-16A-YH13/2 15-16
LW39-16B-YH13/2
LW39-25-YH13/2
A72 B100 A B C
-90o 0o 90o
A 1-2
B 3-4
C 5-6 V 3 CTS,Zero position,threee phase current switching meas

N 7-8 LW39-16A-LH3/4
A B C LW39-16B-LH3/4
LW39-25-LH3/4
A74 B102 O A B C
0o 90o 180o 270o
Zero position,Line N,threee line voltage switching meas
1-2
LW39-16A-YH22/3
LW39-16B-YH22/3 5-6
LW39-25-YH22/3 7-8
A75 B103 O AB BC CA A
9-10
o o o o
0 90 180 270
A 1-2 13-14
3-4 15-16
B 5-6
7-8 V
C 9-10
11-12

21
LW39 Series Cam Switch

Pre-on/off switch
LW39A series LW39-16A-Z/1a.4.20/4
Model
LW39-16A-ZJ/1a.4.6a.40.20/7 LW39-25-Z/1a.4.20/4
Model
LW39-25-ZJ/1a.4.6a.40.20/7 post-off pre-on on post-on pre-off off

post-off pre-on on post-on pre-off off

Fixing angle -90 0 45 0 -90 -135


-90 0 45 0 -90 -135 1-2
Fixing angle
1a
3-4
1-3
1a 5-6
2-4 4
7-8
5-8
4 9-10
6-7
11-12
9-10 20
13-14
6a 10 15-16
9-12 Noted : Substituted for LW2-Z-1a.4.20/F8
11-10
13-14 LW39-16A-Z/1a.4.6a.40.20/5
Model
40 15-14 LW39-25-Z/1a.4.6a.40.20/5
13-16 post-off pre-on on post-on pre-off off

17-19
20 20-18 Fixing angle -90 0 45 0 -90 -135
17-18
1-2
1a
Noted : Substituted for LW2-Z-1a.4.6a.40.20/F8 3-4
5-6
LW39-16A-Z/49.6781/8 4
Model 7-8
LW39-25-Z/49.6781/8 9-10
post-off pre-on on post-on pre-off off 6a
11-12
13-14
40
Fixing angle -90 0 45 0 -90 -135 15-16
1-2 17-18
20
3-4 19-20
5-6 Noted : Substituted for LW2-Z-1a.4.6a.40.20/F8
7-8
9-10 LW39-16A-ZJ/1a.4.6a.20/6
Model
11-12 LW39-25-ZJ/1a.4.6a.20/6
13-14 post-off pre-on on post-on pre-off off

15-16
17-18 Fixing angle -90 0 45 0 -90 -135
19-20 1-3
1a
21-22 2-4
5-8
23-24 4
6-7
25-26
9-10
27-28 10
29-30 6a
9-12
31-32 11-10
Noted : Substituted for LW12-16D/49.6781.7 13-14
13-15
20
16-14
22
Changeover switch for capacitance
Multi-step switches (ten position) Multi-step switches (nine position)
LW39-16A-3OI-21-9/6 LW39-16A-3JF-0-8/4
LW39-16B-3OI-21-9/6 LW39-16B-3JF-0-8/4
Auto 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
-30 0 30 60 90 120 150 180 210 240 -90 -60 30 0 30 60 90 120 150
1-2 1-2
3-4 3-4
5-6 5-6
7-8 7-8
9-10 9-10
11-12 11-12
13-14 13-14
15-16 15-16
17-18
19-20
21-22
23-24

Multi-step switches (eight position) Multi-step switches (seven position)


LW39-16A-3OG-21-7/5 LW39-16A-3JD-0-6/3
LW39-16B-3OG-21-7/5 LW39-16B-3JD-0-6/3
Auto 0 1 2 3 4 5 6 0 1 2 3 4 5 6
-30 0 30 60 90 120 150 180 -90 -60 30 0 30 60 90
1-2 1-2
3-4 3-4
5-6 5-6
7-8 7-8
9-10 9-10
11-12 11-12
13-14
15-16
17-18
19-20

Multi-step switches (twelve position) Multi-step switches (eleven position)


LW39-16A-3OK-21-AC/7 LW39-16A-3JH-0-A/5
LW39-16B-3OK-21-AC/7 LW39-16B-3JH-0-A/5
Auto 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10
-30 0 30 60 90 120 150 180 210 240 270 300 -90 -60 30 0 30 60 90 120 150 180 210
1-2 1-2
3-4 3-4
5-6 5-6
7-8 7-8
9-10 9-10
11-12 11-12
13-14 13-14
15-16 15-16
17-18 17-18
19-20 19-20
21-22
23-24
25-26
27-28

23
LW39 Series Cam Switch

Order Notice

Company : Contact person:


Tel: Fax:

Basic technical data :


Rated thermal current:
Function: Code number of handle

Symbol

Angle

1 2

3 4

5 6

7 8

9 10

11 12

13 14

15 16

17 18

19 20

21 22

23 24

25 26

27 28

29 30

31 32

33 34

35 36

37 38

39 40

41 42

43 44

45 46

47 48

Model Number (filled by factory) :