You are on page 1of 3

PLUMBING CODE PART 02

1. Septic tank should be at least C RIGHT 1


_________meters away from any source of
water supply wells

A. 20
B. 10
C. 15
D. 25
2. The National Master Plumbing Association of C RIGHT 1
the Philippines (NAMPAP) was organized and
registered with the Securities and Exchange
Commission in what year?

A. 1933
B. 1934
C. 1935
D. 1945
3. A registered Master Plumber shall not injure C RIGHT 1
falsely or maliciously, directly or indirectly, the
reputation of another registered Master Plumber
by reviewing his/her work for the same client
unless the professional services of the former
have been officially ______and all professional
fees have been fully paid by the client.

A. Endorsed
B. Accepted
C. Terminated
D. Completed
4. When shower interceptors are built above C RIGHT 1
ground, the sub-floor and rough side of walls to a
height of no less than ____mm above the top of
the finished dam or threshold shall be first lined.
With sheet lead or copper or with other durable
and water tight material.

A. 25
B. 75
C. 105
D. 50
5. In water test, the water shall be kept in pipe C RIGHT 1
system or in portion under test for at least
______minutes before inspection starts. The
system shall be tight at all joints.

A. 20
B. 10
C. 15
D. 3
6. What is AVB in backflow prevention devices? B RIGHT 1

A. Atmospheric Volume Breaker


B. Atmospheric Vacuum Breaker
C. Atmospheric Velocity Breaker
D. Atmospheric Valve Breaker
7. When potable water is discharge to the A RIGHT 1
drainage system, it shall be by means of
approved air gap of 2 pipe size diameter from
the supply of the outlet and top surface of the
drainage inlet, but in no case shall be less than
____mm

A. 25 mm
B. 50 mm
C. 32 mm
D. 55 mm
8. Potable water inlet to gravity tank shall be B RIGHT 1
controlled by a ___ float switch or electrode type
of level water level control to prevent the tank
from overflow.

A. Foot valve
B. Float valve
C. Check valve
D. Gate valve
9. What is water fixture supply unit of privately B RIGHT 1
use bathtub?
A. 1
B. 2
C. 3
D. 4
10. Bell and spigot cast iron soil pipe (CISP) and A RIGHT 1
other similar joints shall be firmly packed with
oakum or hemp and filled with molten pig lead
to n depth of not less than ____mm.

A. 25.4
B. 50.2
C. 10
D. 13
11. Solder and fluxes with lead content which B RIGHT 1
exceeds______ are prohibited in the piping
systems used to conveyed potable water.
A. 0.003
B. 0.002
C. 0.001
D. 0.008
12. What is CS and PS means? B RIGHT 1
A. Commercial Specification and Product
Specification
B. Commercial Standards and Product Standards

C. Commercial Systems and Product Systems


D. Commercial Sizes and Product Sizes
13. A stop valve place in service pipe near its B RIGHT 1
connection with the water main is called:
A. Service cock
B. Corporation cock
C. Stop cock
D. Gate valve
14. Plastic pipe shall be supported at every C RIGHT 1
____interval
A. 1 meter
B. 2 meters
C. 1.5 meters
D. 1.4 meters
15. Supports of cast iron soil pipe shall be D RIGHT 1
adequate to maintain alignment and to prevent
sagging and shall be placed within ___meter of
the hub or joint.

A. 0.65
B. 0.55
C. 0.5
D. 0.45
16. A valve or opened by the fall and rise C RIGHT 1
respectively, of an attached ball floating on the
surface

A. Check valve

You might also like