Connect the ADS serial port (rs232 connection) to the pc with the rs232 cat5 cable
if the pc doesn’t accept serial connection. The Usb-232 connection is used in
placed of serial connection between the ADS and PC.
Proper connection illustrated below.

Connect the KVM serial port (rs232 connection) to the pc if the pc doesn’t accept
serial use the usb-232 connection
PC->USB RS 232 cable -> RS232 CAT5 cable-> ADS serial port

PC USB RS 232 Cable RS 232 CAT5 cable Serial Port

USB RS 232 driver: driver (u232-p9) any other generic USB RS 232 driver
will work but no driver is available from ConnectPro
- Once the file is done downloading, the computer will recognize the
connection as a com port under device manager
Com Port’s location
Device manager is needed to check on the ports being used and what is being
initialized
 Right click my Computer

 Under Properties and left click to enter the Device Manager.


 Accessing Device Manager look for the port
--ex. (com3) Serial On USB Port
 Search for Ports and see where the connection is being made between the
ADS and the PC.
Accessing TeraTerm
Using Tera Term for RS232

Download TERA TERM if the PC doesn’t have a RS232 program already.


 Click on Tera Term and a window will pop up asking about a new
connection

 Make sure the bubble is under “Serial”


 Port : COM3: Serial On USB Port(COM3) or whichever port is listed in
the device manager listed as USB and serial connection

 Makes change to the terminal and serial port by going to “Setup”


 “SETUP” to “Terminal”
 Check the box “Local echo”
 “SETUP” to “Serial Port”
 Makes changes to the baud rate to : “11520”
 Change Flow control : “none”
Testing the Connection

-Call the device by either resetting the device or disconnecting the device and call
again
--make sure serial connection is made between the device and PC
(Disconnect the call and power supply to the device afterward, call the device and
re-attach the power supply) if resetting the device isn’t working.
-the device will give the information and version number

RS 232 commands
Serial
Function Screen Respost
Command
ADS Status
ADS-14-I F/W: V1.2
Buzzer: OFF
ADS Sync
Auto Scan: 2(8Sec)
DDM Keyboard: Console Port
s1v0 List ADS All Status CH-1_DVI_Trigger Off
CH-2_DVI_Trigger Off
CH-3_DVI_Trigger Off
CH-4_DVI_Trigger Off
ADS Video 1
ADS Audio 1

s1v0 show all status ADS Video ADS Audio

s1a0 show all status ADS Video ADS Audio

audio/ video
async asynchronized asynch
command
audio/ video
sync synchr
synchronized command
SYNC jump to console
ch(x=1,2,3,….) channel Y
CHX

Bzon Buzzer ON bzon


Bzoff Buzzer OFF bzoff
CH-1_DVI_Trigger Off ADS Video 1
s1v1 select video port 1
ADS Audio 1
select video port CH-2,_DVI_Trigger Off ADS Video 1
s1v(2,3,4,..) 2,3,4,… ADS Audio 2,3,4,….
CH-1_DVI_Trigger Off ADS Video 1
s1a1 select video port 1
ADS Audio 1
CH-1_DVI_Trigger Off ADS Video 1
s1a(2,3,4..) select audio port 2,3,4,…
ADS Audio 2,3,4,….

More serial commands will be updated on www.Connectpro.com