Gro - Suvnaini
Construction Materials Testing Laboratory ° = —=—$—=—=—=
over ie aang at zz >
0. Bor: Fe (01) 344 wa :
= Sea 16t — fai 0) 40201 JAS S|
Certificate # 3512.05, Saudi Arabia ~ E-mail: fslubail@fugro-suhaimi com
PARTICLE SIZE ANALYSIS TEST REPORT
Client China Petroleum Pipeline Engineering Co Saudi Arabia
Project | SAOMPP
Material | Select Fill
SATA5134
193813/S2
ASTM.
] The procedure used to obtain the | Method 06913 | 5
3 RFI CPP-Civil-342 | specimen(s) from the sample
jource | TADAMCO) from the sample
Moist | AirDry | Oven dry (v) | Date Sampled 12 May 2019
Apparatus used for dispersion _| Date Tested 19-14 May 2019,
Excluded Material None | Gitrasonis nn
pepe eon Date Reported | 15 May 21019
z
=f
‘00 0 1 Grain Size, mm 04 oot 001
Tae [eee Sitorctay |
Description of Sand / Gravel Particles:
‘Shape Hardness ‘Specific Gravity
‘Sieve Size Properties Tested
% Passi Speciation
3 ‘am. ne oe ten Dessriion Resuls
# 75:00 =
aon = 1 | Liquid timit 20.1
2 50.00 100
e Tl 7 2 | Plastic imit Non Plastic
4 25.00 5
xe 130 = _3_| Plasticity Index Non Plastic
ve 125 100 =
38 4 =
No.4 88 =
No. 10 73 =
No. 20 4 =
No. 40 46. =
No.60 | 0.250] 25 z
No. 100 0.150 a7 =
No. 200 0.075 38 020
Remarks | The test result indicate materials compliance with, SeGlen | 2 es selecy Fill Material
poor .
“Note: The test results given above apply only tothe sample test pasar — Surette
Tested By Reviewed By: _UE 7
SS aiision}
CTTA#: _0194 CTTA#: 0723 een
bait LAN
The copyright ofthis document is owned by Fugro-Suhaimi Ltd It may not be reproduced oxcept with prior writin approval from the company.
Form # MAT 3.02 tesue #2 Rov2 04 April 2018
CTTA #. 0037Jubail Branch
P.O. Box 2185 — Tel.: (013) 341 2700
Dammam 31451 — Fax:(013) 344 2701
Saudi Arabia ~ E-mail; {sliubail@fugro-suhaimicom
Certificate # 3512.05,
Construction Materials Testing Laboratory USE = Sunarn
a
aged
LABORATORY COMPACTION CHARACTERISTICS OF SOIL
TEST REPORT
7] China Petroleum Pipeline Engineering Co Saudi
SA145134
Arabia,
SAOMPP 193813/S2
| seiect Fi 15 May 2018
RFl# CPP.Civi-342 (ADAMCO) Sada
1950 = T
+ t
100% Saturated
Dry Density, kg/m3.
aera ee ea feeeaeeedioar een teieeyee enim dees Fer ior -eauett aa -eenartee yacetti4a
Water Content, %
942.52 Correction for Oversize Material ASTM D- 4718
‘ASTM D-1557-12 :
eet Oversize Fraction (Ret. 4.75Sieve), % 116
‘Optimum Moisture Content, % 7.7 | Oversize Fraction (Pass. 4.75 Sieve), % 88.4
5 ae Bulk Specific Gravity (ASTM CAZ7)
Maximum Dry Density, kg/m: 1007 _ (BBRSeaete ceri ” 2.168
: Mechanical Corrected Optimum Moisture Content % 70
Corrected Maximum Dry Density, kgimn? 1048
"Note: The test resulls given above apply only to the sample tested,
Tested By:_TD. Reviewed By: _UF_.
CTTA# +0198 CTTA# 0723
-The-copyright oF by Fugro-Suhaim
Form # MAT 3.04 Issue #2 Rev.2 01 April 2018Construction Materials Testing Laboratory
Jubail Branch
POBox Gh = Tal)
Dammam 31451 ~ Fax va
Certificate #3512.05 Saudi Arabia ~ E-mail: feljuball@fugro-suhaimicom — 2-29 -_ g_2|
MAXIMUM AND MINIMUM INDEX DENSITY
TEST REPORT
China Petroleum Pipeline Engineering Co Saudi Arabia | Job No. SA-145134
SAOMPP_ Lab No. 193813/S3
Clean Sand ‘ARAMCO CN #, -
Method ASTM D-4253 / ASTM D-4254 Date of Sampling 12 May 2019
Source RFI CPP-Civil-342; (ADAMCO) Date of Reporting | 15 May 2019
Test Result Method
Mesut ex Doty Kone 1829 ASTM 0.4253
‘Minimum Index Density Kgim* 1587 alee
Location of Use RFl# CPP-Civil-342; (ADAMCO)
‘d Clean Sand
Mold Volume om 2830.36 a
Remarks
Note: The test results given above apply only to the sample tested,
Tested by: 10 Reviewed by: _UF
CTTA# 0104 CITA” 0723
Material Division
Jubail Lab (11)
The copyright ofthis document Is owned by Fugro-Suhaim Ltd. It may not he reproduced except with prior writen approval fom the company.
Form #MAT 3.15 issue #2 Reva ‘OF Ape 2078AR
>)
(&ccnEDIrED)
Certificate # 3512.05
Construction Materials Testing Labora
Gro - Svvaim
Jubail
P.O. Box 2165 —
Dammam 31451. —
Tel: (013) 341 2700
Fax.(013) 341 2701
Saud! Arabia — Evrall eluball@tugrodufimidbnt °C)
PARTICLE SIZE ANALYSIS TEST REPORT
China Petroleum Pipeline Engineering Co Saudi
cient | enna Job No. SA145134
Project | SAOMPP Lab No. 193813/83
Material__| Sand astu [A (7)
The procedure used to oblainthe | Method 06813 |g
source | RFIECPP-civi'342; | Specments) rom the sample.
ee Moist | Air Dry | Oven dry (v) | Date Sampled 12 May 2019
Apparatus used for dispersion | Date Tested | 13-14 May 2019
Excluded Material None | iiissone Tereion
ia esse, [Date Reported | 15 May 2019
wo ote wis 46s go Wms wo nw 20
oo [i +—}
wo PE]
5 si
a :
= so (TEE
iw :
fn =
t i
=
0 » 1 Grain Size, mm 01 aos oot
ce |e ef Sitor hay
Description of Sand / Gravel Particles:
Hardness Specific Gravity
Seve Seo Wei ae Properies Teed
z a eT Resuis | Specifeation
2 63.00 :
a an = 1 | Liuia tit - 7
[iw 3750 a 7 ,
4 22 Ser : 2 | Paste im 7 :
% 19.00 : =
= 22 = = 3 | Plasticity Index -
ae [950 : :
a 625 oa 100)
Nod 475 700 =
Na. 10 209 100. 0-100
No.20 | 0850 98 7
No. a0 0425 50.
No.60 | 0280 20 =
No.100 | 0150 2 =
No. 200 | 0075 43 WDorless
Remarks | The test result indicate materials compliance with SAES A-114, Section 4 as Clean sand Mafia
Note: The test results given above apply only to the sample
Tested By:
CTTAR.
1D,
198
Reviewed By: _UF.
crta#: — 0723
‘The copyright ofthis document is owned by Fugro-Suhalmi Lt. It may not be reproduced except with prior writen approval from the company.
Form # MAT 3.02
Issue #2
Rev.2
01 April 2018