You are on page 1of 2

Question Bank for 3rd and 4th Module

1. What is single phasing ? Explain the operation of 3-phase induction


motor with unbalanced voltages.

2. Explain the 3-phase induction motor operation with

unbalanced motor impedance.

3. Explain the requirements the induction motor for starting purpose

4. Explain the any three types of starting methods

5. 400V,star connected,3-phase,6-pole,50 Hz induction motors have the


following parameters referred to stator;Rs= Rr= 1Ω, XS= Xr =2Ω,For
regenerative braking operation of this motor determine;

A).Maximum overhauling torque it can hold and range of speed for


safe operation .

B). Speed at which it will hold and overhauling load with torque
of 100 N-m

C) . Maximum overhauling torque the motor can hold as a ratio of


maximum overhauling torque without capacitor if a capacitive
reactance of 2 Ω is inserted in each phase of stator.

6. Motor of the above question is to be braked by plugging from its


initial full load of speed of 950 rpm.Stator to rotor turns ratio 2:3.
Calculate

A} The initial braking current and torque as a ratio of their full


load values
B} What resistance must be inserted in rotor circuit to reduce
the maximum braking current to 1.5 times full load current? What
will be the initial braking torque now?

7. Explain the available frequency control of induction motor and


mention any any two features .
8. Draw a neat diagram and explain star-delta,and auto transformer
method of starting of three phase induction motor

9. Explain the operation of voltage source inverter fed induction motor


drive

10. Explain the static rotor resistance control

You might also like