1. What is single phasing ? Explain the operation of 3-phase induction
motor with unbalanced voltages.
2. Explain the 3-phase induction motor operation with
unbalanced motor impedance.
3. Explain the requirements the induction motor for starting purpose
4. Explain the any three types of starting methods
5. 400V,star connected,3-phase,6-pole,50 Hz induction motors have the
following parameters referred to stator;Rs= Rr= 1Ω, XS= Xr =2Ω,For regenerative braking operation of this motor determine;
A).Maximum overhauling torque it can hold and range of speed for
safe operation .
B). Speed at which it will hold and overhauling load with torque of 100 N-m
C) . Maximum overhauling torque the motor can hold as a ratio of
maximum overhauling torque without capacitor if a capacitive reactance of 2 Ω is inserted in each phase of stator.
6. Motor of the above question is to be braked by plugging from its
initial full load of speed of 950 rpm.Stator to rotor turns ratio 2:3. Calculate
A} The initial braking current and torque as a ratio of their full
load values B} What resistance must be inserted in rotor circuit to reduce the maximum braking current to 1.5 times full load current? What will be the initial braking torque now?
7. Explain the available frequency control of induction motor and
mention any any two features . 8. Draw a neat diagram and explain star-delta,and auto transformer method of starting of three phase induction motor
9. Explain the operation of voltage source inverter fed induction motor