Professional Documents
Culture Documents
A UT OMA T IC C OF F E E MA C HINE S
DE LONGHI ECAM23210
(J
P)
DA T I T E C NIC I / T E C HNIC A L DA T A
S E ZIO NE C A F F E ' / C O F F E E S E C T IO N
Sonda termica / Temperature probe °C 98 (Caffè / Acqua calda)
(Coffee / Hot water)
1
TECHNICALSHEET ST1609/2011
SCHEMA ELETTRICO / ELECTRICAL DIAGRAM
M1 Inf
usor
eal
to/ Inf
usert
op posi
tion
M2 Inf
usor
ebasso/ Inf
userbot
tom posi
tion
M3 Casset
tof
ondi/ Cof
feegr
oundscont
ainer
M4 Tani
ca/ Tank
M5 Rubi
net
to/ Tap
NERO/
BLACK
CELLA DIHALL
NERO/
BLACK
HALL CELL
NERO/
BLACK NERO/
BLACK
NERO/
BLACK NERO/
BLACK M5
NERO/
BLACK
M2 NERO/
BLACK M1
SENSOREREED
REED SENSOR
TCO FLUSSI
METRO
THERMAL CUT OFF FLOWMETER
ROSSO/
RED
M MACININO
COFFEE BI
ANCO/
WHI
TE
GRINDER
NERO/
BLACK
MOTORETRASMISSIONE
CALDAIA ROSSO/
RED M TRANSMI
SSION MOTOR
BOILER
ROSSO/
RED BI
ANCO/
WHI
TE
MARRONE/
BROWN
TCO
THERMAL CUT OFF POMPA/
PUMP
P
PUMP THERMAL PROTECTOR
MOTOPROTETTOREPOMPA
ROSSO/
RED
MARRONE/
BROWN
MARRONE/
BROWN
NERO/
BLACK
BLU/
BLUE
INTERRUTTOREON/
OFF
ON/OFF SWITCH
BLU/
BLUE
MARRONE/
BROWN
M4
M3
SONDA TEMP.
PCB DISPLAY
TEMPERATURE SCHEDA DISPLAY
PROBE
CELLA DI HALL
HALL CELL
M5
M2
M1
SENSORE REED / REED SENSOR
FLUSSIMETRO
FLOWMETER
MACININO
COFFEE TCO
GRINDER THERMAL CUT OFF
MOTORE TRASMISSIONE
M TRANSMISSION MOTOR
RESISTENZA M4
HEATING EL. M
P
POMPA/PUMP
TCO
THERMAL CUT OFF
M3
INTERRUTTORE ON/OFF
ON/OFF SWITCH
Picture 1 Picture 2.
Take off water
tank
Picture 3.
Take off drip tray Picture 4.
and waste container Unscrew the 5 indicated screws
(Torx T20)
Picture 5
6.4
Lift upper panel
6.5
Take off cable
6.6
Unscrew the 2 indicated screws.
Then,lift with care the Control Panel
Page 2
Picture 7 - TO REMOVE COFFEE GRINDER
7.2 7.1
Lift coffee grinder pushing Take off cables on the right
it back with delicacy side of the board
7.3
To separate coffee grinder
unscrew the indicated screw.
8.1
Take off cable and
take out flowmeter
Page 3
9.2
Take off pump Picture 9 - TO REMOVE PUMP
9.3
9.1 Attention: After you have taken off cables,
Take off the spring you will have to take off pump thermal protector.
and then the tube Since it is glued, you will have to use a certain strength.
Attention: Some water could come out Remember to glue it again when you will reassemble it
from the tube, since the water circuit is
empting out
10.1
Take off the 4 indicated screws. After you have taken off cables, take out the board
Page 4
11.1
Unscrew the 4 indicated screw
you find on the rear of the motor
11.2
take off the 2 cables
and then take off
the DC motor.
Pay attention to
polarity when
replacing it
Page 5
12.1
Take off cables
Picture 12 - TO REMOVE TAP STEAM/HOT WATER
12.2
Unscrew the 2 indicated screws
12.3
Take off microswitch
Page 6
13.3
Take off the spring
indicated by the arrow and
then the tube
Picture 13 - TO REMOVE BOILER
13.2
Take off the
tube
13.1
Take off the indicated 2 springs
and the 4 screws.
13.4
Take off the cover.
Then unscrew the 2 indicated
screws to disassemble
the boiler
Page 7
Picture14 - TO REMOVE INFUSER KIT
Figura 14.1
Open infuser box.
Push the 2 buttons and take out
the infuser
Page 8
15.1
Unscrew the 10 indicated screws
Picture 15 - TO REMOVE TRANSMISSION KIT
15.2
Open infuser box
15.3
Unscrew the 2 indicated screws
(Torx T20) and remove the slider
15.4
Take off the indicated screw
Page 9
15.5
To remoce the Feeler Board (hall Sensor)
unscrew the 2 indicated screw to remove
the Hall sensor
15.6
Pay attention, when you take off the
plastic component, to the 2 indicated
metal spacers
(ATTENTION: about metal
spacers see Technical Info
IT0181)
Page 10
Picture 16 - TO REMOVE COFFEE SPOUT
16.1
Unscrew the 2 indicated screws
and remove the coffee spout
16.2
Payattention to the spring
assembled with slider
Pag. 11
17.2
Picture 17 - TO REMOVE VALVE ASSEMBLY
Unscrew the 2 indicated screws
(see Technical Info IT0181)
using an Allen key (4)
17.1
Take off the 2 springs
and then the
tubes
17.3
Take off the spring
and then the tube
which goes from
coffee spout to
infuser
17.4
Unscrew the indicated screw
17.5
to take off microswitch
Take off microswitch
Page 12
Pi
ctur
e 18- HOW TO ALIGN VALVE
Li
ftthe i
nfuserupt otot
ouchthe val
ve,wi
thoutpushing wi
thst
rength:i
thasonl
ytobe
al
ignedtot he val
ve.
Once youalignedit,f
ixt
he 2scr
ews( pi
c.18.2) usi
ng anAll
enkey.
18.
1
Scr
ew the 2indi
cat
edscr
ews
usi
ng anAll
enkey( 4)
18.2
Fitinthe tube
andt hen
the spri
ng
Page 13
Picture 19 - MICROSWITCH AND
WATER REED POSITION
19.1
Water Tank
microswitch
ATTENTION: please, pay attention
to never bypass microswitch.
If you should do it
infuser motor would be on
19.3
Steam tap
microswitch
19.4
Infuser bottom limit
microswitch
19.5
Waste container
microswitch
19.6
Reed switch
water tank
Page 14
WATER CIRCUIT
VALVE
BOILER
INFUSER
SAFETY
VALVE
EXPANSION
PUMP CHAMBER
DUMPER
FLOWMETER
DRIP TRAY
WATER TANK
FILTER
TEST PROCEDURE FOR
ECAM23.210 INTENSA
Pr
essi
ngeachiconbelow,wecan
TEST PROCEDURE manuall
ycheckthedevices:
i
con devi
ce
PutSteam Tapon0.
Cof
feBoi
lerON
Pl
ugt hemachineON.
Pressandhold:1Cof
fee+ St
eam but
tons
Gr
inderON
MotorUP,t
il
l“UPPER LIMIT
MotorDOWN,t i
ll“
BOTTOM
LIMIT
Wat
erPumpON
Pr
essOn/
OffSwi
tch(
posi
ti
onI)
NOTE:Rel
easebt
tonswhenmot
or
st
art
smoving.
NOTE:Ever
yledbl
inkswhent
hemi
croswi
tchi
sopen
ToEXIT t
hepr
ocedur
e,pr
essOn/
OffSwi
cth(
posi
ti
on0)orunpl
ugt
hemachi
ne.
DISPLAY TEST PROCEDUREFOR
ECAM23.210 INTENSA
NOTE: After display Test performing, you need to intialize the machine.
To EXIT the procedure, press On/Off Swicth (position 0) or unplug the machine.
Test procedure ends automatically 1 minute after you complete it.