Reinforced Cement Concrete Construction up to plinth

Structural Components of framed building structure (RCC)


 The vertical elements are the columns.
 The horizontal bands are the beams.
 The flat surface on which you can stand is the slab.
The loads such live load and dead load is carried by frame of Column, Beam and
Slab.

RCC UPTO PLINTH


RCC STRUCTURE

Non-Structural Components of framed building


structure:-
 Walls, Doors, Windows - Protection to inhabitants.
 The walls - Protecting the inhabitants from
weather. Act as Partition wall in the Framed
structure.

Why it is essential?
 High relative strength
 High toleration of tensile strain
 Good bond to the concrete, irrespective of pH,
moisture, and similar factors.
 Thermal compatibility, not causing unacceptable
stresses in response to changing temperatures.
 Durability in the concrete environment,
irrespective of corrosion or sustained stress for
example.

RCC UPTO PLINTH


RCC STRUCTURE

Mechanism of Load Transfer in R.C.C.


 Function of structure is to transfer all the loads safely to ground.
 A particular structural member transfers load to other structural member.

Load TRANSFER

Roof Surface

Roof Slab

Beams

Column

Foundation

Sub Soil

RCC UPTO PLINTH


RCC FOUNDATION

Isolated Footing: A footing that supports an individual column is known as an isolated


footing.

RCC UPTO PLINTH


RCC STRUCTURE –
KEY PLAN

COLUMN SCHEDULE
3.2X4.20
COLUMNS SIZES (MM)

C01 230X230

C02, C03, C07, C11, C12, C13, C14 230X450

C04, C05, C06, C08, C09, C10, 450X230

NOTES

1. INTERNAL WALL THICKNESS – 150 MM

2. EXTERNAL WALL THICKNESS – 230 MM

3. RISER – 150MM, TREAD – 300 MM

DOOR SCHEDULE WINDOW SCHEDULE

D 1200X2100 W 1500X1200

D1 1000X2100 W1 1500X900

D2 750X2100 V 600X750

RCC UPTO PLINTH


FOUNDATION PLAN

COLUMN SCHEDULE

COLUMNS SIZES (MM)

C01 230X230

C02, C03, C07, C11, C12, C13, C14 230X450

C04, C05, C06, C08, C09, C10, 450X230

Combined footing
Eccentric footing
Eccentric footing with strap beam
Strap beam
Isolated pad footing
Combined trapezoidal footing
450

450 450
Isolated slope footing
450

RCC UPTO PLINTH


REINFORECMENT DETAILS OF RCC FOOTINGS

RCC UPTO PLINTH


REINFORECMENT DETAILS OF RCC FOOTINGS

SEM III : BCM III RCC UPTO PLINTH


REINFORECMENT DETAILS OF RCC FOOTINGS

RCC UPTO PLINTH


REINFORECMENT DETAILS OF RCC FOOTINGS

TYPICAL SECTION (PAD FOOTING)

Reinforcement Details
1. PCC thickness = 150 mm Footing Side Cover – 50MM Footing Bottom Cover – 25 MM
2. Footing bars along the shorter span and longer span = 12 mm T @100 C/C
3. Depth of footing = 450 mm (Pad Footing), 150+300 (Sloped Footing)
4. Column bars (230x450) = 6T 12 mm Column Cover = 30 MM
5. Column bars (230x230) = 4T 12 mm Column Cover = 30 MM
6. Links = 8 mm T 100C/C

RCC UPTO PLINTH


ICAD
PLINTH BEAM PLAN

NOTES

1. Beam size - 230x 750 mm

2. Beam Bars = Top Steel 2 T 12 MM


Bottom Steel 3 T 16 MM
3. Stirrups = 8 mm T 100 – 150 mm C/C

RCC UPTO PLINTH


PLINTH BEAM PLAN

RCC UPTO PLINTH


PLINTH BEAM
PLAN

RCC UPTO PLINTH


ICAD
COLUMN BEAM PLAN

SEM III : BCM III RCC UPTO PLINTH


100
300

750
100
100

PLINTH BEAM -
SEM III : BCM III TOILET SUNK SECTION
REFERENCES

 https://gharpedia.com/blog/various-types-of-footings-for-your-house/
 http://www.constructioncivilengineering.com/column-footings-foundation-design.html
 https://constrblog.wordpress.com/2017/06/13/types-of-footings-with-diagrams/