You are on page 1of 2

 

FRONTHAUL 6681
Ericsson’s Fronthaul 6080 family provides the WDM networking Centralized RAN and 5G networks
solution for fronthaul transport of Common Public Radio LTE, LTE-Advanced and 5G will increasingly demand higher
Interface (CPRI), Open Base Station Architecture Initiative capacity and lower latency capabilities from operators’ networks
(OBSAI) and Ethernet from the Radio Baseband Units (BBU) to where tight coordination is key for efficient spectrum utilization.
Remote Radio Units (RRU), Ericsson Integrated Antenna & Centralized RAN (C-RAN) implemented with Fronthaul 6080
Radio Units (AIR) and the Ericsson Radio DOT System. reduces the footprint and power/cooling requirements at the cell
The Fronthaul 6080 can either be an active or passive solution sites and offers tight coordination which is key for advanced
and enables the centralization of the BBUs to achieve a radio features to build high performing mobile networks.
coordinated radio access network architecture as well as to
accelerate small cell deployments with or without WiFi. Supports various network topologies
The Fronthaul 6681 can be used in active main sites of different
The Fronthaul 6080 passive solution is composed of a set of networks such as linear chain, PtP, PtMP and Hub&Spoke (from
innovative passive filter modules allowing any network topology 2 to 8 tails). It also offers feeder protection and GPON
to meet the requirements on low possible cost and small or no Coexistence. The filters used are Single Fiber Working (SFW).
footprint. The Fronthaul 6080 can support Point-to-Multipoint Active solution (when required) also leverage on the same
(P2MP) with or without feeder protection, GPON coexistence passive components
and as well as Linear Chains or Point-to-Point (PTP).

The Fronthaul 6681 is the main passive unit deployed at the ERS integrated solution
BBU site and is connected to one or more remote units, such as Ericsson Radio System is an innovative, modular system that
the indoor Fronthaul 6388 or the outdoor Fronthaul 6385, enables mobile operators to address growth opportunities and
Fronthaul 6387 or Fronthaul 6389 residing at the RRUs. transform their radio networks. The Fronthaul 6681, with the rest
The Fronthaul 6681 passive solution supports various network of the Fronthaul 6080 family members, is part the Ericsson
application scenarios and can provide up to 24 services per Radio System, and is integrated with many other components.
configuration. Configuration varies depending on the network It can be used together with Baseband 5216 and Baseband
application. The main components are1: C608 allowing Elastic RAN to expand the CoMP and CA
benefits to the whole network.
 Optical Add/Drop filters
 Optical Mux/Demux filters
 Optical Protection Module
 GPON filters

                                                            
1
 complete list in next page, see dedicated document for more details about each component
Technical specification for Fronthaul 6681
SERVICES PER PORT (up to 24 services can be served)
CPRI service types: CPRI Option 2 (1,228.8 Mbit/s)
CPRI Option 3 (2,457.6 Mbit/s)
CPRI Option 4 (3,072.0 Mbit/s)
CPRI Option 5 (4,915.2 Mbit/s)
CPRI Option 6 (6,144.0 Mbit/s)
CPRI Option 7 (9,830.4 Mbit/s)
CPRI Option 8 (10,137.6 Mbit/s)
OBSAI service types: OBSAI 1G (1,536 Mbit/s)
OBSAI 3G (3,072 Mbit/s)
OBSAI 6G (6,144 Mbit/s)
Ethernet service types: GE (1,250 Mbit/s)
10GE (10,125 Mbit/s)

MECHANICAL
System components*: OMD-24-S: Indoor 48-ch x 100 GHz AAWG SFW Mux/DeMux Unit
LGT-1: Indoor 6-slot half-wide LGX Subrack
OAD-3-S-AH: Indoor/Outdoor 6-ch x 100 GHz OAD SFW Unit - Variant A to H
BMD-8-S: Outdoor 8-band SFW Mux/DeMux Unit
SPL-2-S-2: Outdoor 2x2 LGX Optical Power Splitter/Coupler Unit
SPL-2-S-4: Outdoor 2x4 LGX Optical Power Splitter/Coupler Unit
OMD-4-C: Indoor/Outdoor 8-ch x 100 GHz CWDM SFW Mux/DeMux Unit
OAD-1-C-14: Indoor/Outdoor 2-ch x 100 GHz CWDM SFW OAD Unit - Variant 1 to 4
OPM-1-S-1: Indoor LGX Optical Line Protection Switch Cassette with SFP Plug
GCF-1: Outdoor G-PON Coexistence Optical Filter Unit
Typical main site configurations: (A) Main unit 24 λ: 1×OMD-24-S
(excluding pluggable) (B) Main unit 24 λ with Hub & Spoke: 1×OMD-24-S + 1xLGT + 1xSPL
(C) Main unit 24 λ with Hub & Spoke and protection: 1×OMD-24-S + 1xOPM-1-S-1 + 1xLGT-1
+ 1xSPL
Weight: (A) 3.5 kg or 7.7 Lbs
(B) 6.5 kg or 14.3 Lbs
(C) 6.8 kg or 15 Lbs

ELECTRICAL
Power consumption: No power consumed

STANDARDS AND SPECIFICATIONS


EMI/Emissions and EMC/Immunity: AS/NZS CISPR 22
CISPR 22
CISPR 24
EN 300 386
EN 55022
EN 55024
FCC Title 47, Part 15 (47 CFR 15) Subpart B (USA EMI)
ICES-003
TCVN 7189
VCCI Regulations
Environmental (ENV): EN 300 019-2-1
EN 300 019-2-2
EN 300 019-2-3
EN 300 753
NEBS: GR-63-CORE
GR-1089-CORE
Safety: AS/NZS 60950-1
EN/IEC 60825-1
EN/IEC 60825-2
EN/IEC 60950-1
FDA 21 CFR 1040.10 and 1040.11 (except for deviations pursuant to Laser Notice No.50 June
24, 2007)
UL/CSA 60950-1

 
* for more information regarding each module, please refer to the separate dedicated document

Telefonaktiebolaget LM Ericsson 
SE‐164 80 Stockholm, Sweden  681/28701‐FGC 101 3442 Rev A 
www.ericsson.com  © Ericsson AB 2017 
 

You might also like