You are on page 1of 1

C3 C7

P P
C6 C8
S1
C4
LEGEND
S1
C2 P
P

S1 R
P P
S4 R

S1

P
M
S1
P P C5
S1

P P

S1

S2 S2
C1 P P
S4

S4

M
CONVENIENCE OUTLET LAYOUT
1:100MM
LIGHTING OUTLET LAYOUT SCALE

SCALE 1:100MM
ELECTRICAL SPECIFICATIONS
SERVICE ENTRANCE
40 A NO. OF SWITCHES AMPERE AMPERE 1. ALL ELECTRICAL OUTLET SHALL CONFORM TO THE NEW RULES AND REGULATIONS OF THE
CKT# DESCRIPTION LO CO S1 S2 VOLTS WATTS PER CKT PROTECTOR WIRE (mm2) CONDUIT
S4 NATIONAL ELECTRICAL CODE OF THE PHILIPPINES AND CITY ORDINANCES
230V, 2 - WIRE 60 Hz
8 MM DIA THHN/TWN WIRE
M
1 1- INCANDESCENT BULB,
6 1 1 230 600W 3.26 15A 2 - 2.0 13 MM PVC PIPE
2. ALL ELECTRICAL INSTALLATIONS SHALL BE DONE UNDER THE SUPERVISION OF DULY
IN 20 MM DIA PVC PIPE
20 A 20A 5-PINLIGHT

LICENSED ELCTRICAL ENGINEER


2 5-PINLIGHT
5 1 1 230 500W 2.72 15A 2 - 2.0 13 MM PVC PIPE

C7 C8 3 1-ROUND CEILING LAMP,


2-PINLIGHT 3 2 230 300W 1.63 15A 2 - 2.0 13 MM PVC PIPE 3. ALL WIIRING EQUIPMENT AND FIXTURES SHALL BE BRAND NEW AND SHALL CONFORM TO THE
20 A 20 A STANDARD OF THE BEAUREAU OF PRODUCT STANDARDS
4 1- PINLIGHT,
2- INCANDESCENT BULB 3 3 230 300W 1.63 15A 2 - 2.0 13 MM PVC PIPE

2 4.UNLLESS OTHERWISE INDICATED IN THE PLAN , ALL CONVENIENCE OUTLET SHALL BE PLACED
C5 C6 5 CONVENIENCE OUTLET 230 360W 1.96 20A 2 - 3.5 13 MM PVC PIPE
O.3O M ABOVE FLOOR LEVEL
15 A 15A 6 CONVENIENCE OUTLET 2 230 360W 1.96 20A 2 - 3.5 13 MM PVC PIPE
5. USE CAST ALLOYS FITTTINGS OF PROPERTY FOR ALL OUTLETS ON EXPOSE CONDUIT WORK AND
7 1 230 725W 3.94 20A 2 - 3.5 13 MM PVC PIPE WAETHER PROOF INSTALLATIONS
C3
REFRIGERATOR OUTLET

C4 8 CONVENIENCE OUTLET 3 540W 2.93 20A 2 - 3.5 13 MM PVC PIPE


230
15 A 15A 6. MAKE ALL WIRES CONTINUOS BETWEEN OUTLETS OR FROM PANEL TO OUTLETS
TOTAL 17 8 6 1 2 230 4606.9VA 20.03 40A 2 - 8.0 20 MM PVC PIPE
7. PROVIDE A SEPARATE SERVICE DROP FOR THE BUILDINGS ELECTRICAL WIRINGS
C1 C2
8. ALL WIRINGS SHALL BE CAREFULLY INSPECTED AND APPROVED BY COMPETENT ELECTRICAL
SCHEDULE OF LOADS INSPECTOR BEFORE THE CURRENT IS TURNED ON AND AN APPROVAL BY THE FIRE DEPARTMENT
IS NEEDED

SINGLE LINE DIAGRAM

PRC NO. PROJECT TITLE : OWNER: SHEET CONTENTS: SHEET NO.:

PROPOSED LIGTHING OUTLET LAYOUT


PTC NO.
BUNGALOW TYPE RESIDENTIAL HOUSE CONVENIENCE OUTLET LAYOUT
PROFESSIONAL

DATE ISSUED
SUSAN SANTIAGO ORTILLO SINGLE LINE DIAGRAM
SCHEDULE OF LOADS
E-1
CATARMAN, NORTHERN SAMAR SPECIFICATIONS
LOCATION: PUROK SINAMAR, KALIGASAN, KABACAN, NORTH COTABATO