You are on page 1of 2

NALCO 18 PULV

Oxygen Scavenger
Product Bulletin

PRODUCT DESCRIPTION AND


APPLICATION Based on our hazard evaluation, this product is
considered non-hazardous.

NALCO 18 PULV is a traditional oxygen Ingredients are considered proprietary. See the
scavenger in powdered form that is non-volatile, MSDS for information on regarding hazardous
and inorganic. NALCO 18 PULV is the product components.
of choice for applications where a powdered
form is desired, and relatively large amounts of REGULATORY APPROVALS
dissolved oxygen must be removed rapidly. Please refer to the MSDS for latest approval
Such applications include boiler systems, Hot details.
Water Generators that use relatively cold
feedwater, and systems relatively deviating MATERIALS OF COMPATIBILITY
largely from the saturation temperatures in
Deaerator. NALCO 18 PULV does not promote
passivation of metal surfaces. Compatible Not
NALCO 18 PULV can be used in systems with Compatible
or without deaerator, where the deaerator or Buna-N Aluminium
Feed water temperature is in the range 80 – 120 Polyethylene Brass
Deg C. Carbon
NALCO 18 PULV cannot be fed prior to the Polypropylene Steel
attemperation take-off point or to attemperation PVC Copper
water due to the dissolved solids in the product. Teflon Hypalon
Stainless
PHYSICAL & CHEMICAL Steel* Neoprene
PROPERTIES Viton Nickel

* The listed compatible with


Form Powder 316 stainless steel is conditional
Appearance Off-white to Light due to previously noted
Odor Sweet problems with bulk storage.
Solubility in Water Complete Condensation occurring within
pH (1%) 9.0 – 10.0 the bulk storage tank causes
unsubmerged surfaces to rust.
The condensing water vapor on
NOTE: These physical properties are typical the sides of a tank will contain
values for this product. Please refer to the significant SO3 and create a
Material Safety Data Sheet (MSDS) for the most low pH sufficient to cause
current data and complete information. corrosion in the vapor space.
The corrosion is not general,
but tends to follow the
reoccurring condensation flow
patterns. The rust can then
contaminate the product and
customer system if it is washed ENVIRONMENTAL AND TOXICITY
into the bulk product with the DATA
next tank fill and injected with
the product into the customer's Please refer to the MSDS, SECTIONS 11 and
system. 12, for the most current data.

SAFETY AND HANDLING


See your local Nalco representative for Read the label and MSDS for complete safety
compatibility information. and handling information before using this
product.
DOSAGE AND FEEDING
Please refer to the MSDS, SECTIONS 3 and 8,
The feedwater dosage of NALCO 18 PULV will for the most current data.
vary based on the feedwater oxygen level, boiler
operating pressure and boiler water cycles of STORAGE
concentration.
Underfeed of NALCO 18 PULV will result in NALCO 18 PULV has a maximum
serious oxygen corrosion to the boiler and recommended in-plant storage life of one year in
feedwater system. Underfeed may also factory-sealed containers. Keep container closed
significantly increase the specific risk of very when not in use. The maximum storage
damaging pitting corrosion. The greatest damage temperature is 49°C.
will occur in the economizer or feedwater Bulk NALCO 18 PULV should be stored in
preheaters. Oxygen corrosion will also increase polyethylene, polypropylene, or stainless steel
iron levels in the feedwater, which may result in tanks.
iron deposits and subsequent boiler tube failures
in high heat flux areas of the boiler. Please refer to the MSDS, SECTION 7, for the
Overfeed of NALCO 18 PULV will result in most current data.
high dissolved solid levels in the boiler,
resulting in carryover of dissolved solids, or REMARKS
excessive energy losses due to high blowdown
requirements. Overfeed of NALCO 18 PULV If you need assistance or more information on
will also increase the cost of your chemical this product, please call your nearest Nalco
treatment program and eventually drop the pH of Representative. For more news about Nalco
the Boiler water. Company, visit our website at www.nalco.com.
Contact your local Nalco representative for the
appropriate feeding and dosage For Medical and Transportation Emergencies
recommendations for your application. involving Nalco products, please see the
Material Safety Data Sheet for the phone
For complete dosage, feeding points and feeding number.
equipment, consult your Nalco representative.

N a l c o P a c i f i c P t e L t d 2 International Business Park • #02-20 The Strategy Tower 2 • Singapore 609930

SUBSIDIARIES AND AFFILIATES IN PRINCIPAL LOCATIONS AROUND THE WORLD

NALCO and the logo are trademarks of Nalco Company


Ecolab is a trademark of Ecolab USA Inc.
©2014 Ecolab USA Inc. All Rights Reserved

You might also like