You are on page 1of 1

12 11 10 9 8 7 6 5 4 3 2 1

NOTES
1. ALL DIMENSIONS ARE IN MILLIMETER.
2 ± 0.00 M FFL CORRESPONDS TO +899.14 MSL.
±0.00 M FFL CORRESPONDS TO ARRIVAL LEVEL (LEVEL-0)
3. THIS DRAWING TO BE READ AND NOT TO BE SCALED
TERMINAL 2
4. REFER TO GENERAL SHEETS FOR ABBREVIATIONS,

L
LEGEND OF SYMBOLS, AND MATERIAL KEYNOTES,
AND TYPICAL MOUNTING HEIGHTS. Bangalore
5. THIS DRAWING SHALL BE READ IN CONJUCTION WITH
ALL RELEVANT ARCHITECTURAL, STRUCTURAL AND
International Airport
SERVICES DRAWINGS. ANY DISCREPANCY NOTICED
SHALL BE BROUGHT TO THE ATTENTION OF THE
CONSULTANTS WITHIN 7 WORKING DAYS OF
RECEIVING THE DRAWINGS, PRIOR TO PROCUREMENT
/ EXECUTION OF WORKS.
OWNER
E40 E41 E42 E43 E44 E45 E46 E47 E48 6. ALL DIMENSIONS SHALL BE VERIFIED ON SITE PRIOR TO
START OF WORK AND ANY DISCREPANCY SHALL BE
BROUGHT TO THE NOTICE OF THE EDRC ARCHITECT.
SEE: 1 / SEE: 1 / 7. ALL WALL/CEILING/FLOOR PENETRATION FOR DUCTS,
KIA-B03-L&T-A_ KIA-B03-L&T-A_ PIPES, WIRES, CONDUITS AND GROUPED CONBINATIONS
THEREOF ARE TO BE FIRE STOPPED WITH THE
WD-L1-DWG-1154 WD-L1-DWG-1164 APPROPRIATE TESTED AND APPROVED FIRE STOPPING Bangalore International Airport Limited
MATCHLINE MATCHLINE SYSTEM TO MATCH THE RATING
OF THE FLOOR THROUGH WHICH THEY ARE PENTRATING Project Office
K 8. ALL SHAFT ENCLOSURE WALL TO BE CONSTRUCTED AFTER Kempegowda International
SEE: 1 / SEE: 1 / Airport Bengaluru
THE INSTALLATION OF RELATED SERVICE EQUIPMENT.
KIA-B03-L&T-A_ KIA-B03-L&T-A_ 9. PROVIDE HOUSEKEEPING PADS AT UTILITY ROOMS AS PER
Devanahalli, Bangalore 560 300 India
WD-L1-DWG-1164 WD-L1-DWG-1174 REQUIREMENTS IN MEP DRAWINGS.
MATCHLINE MATCHLINE 10. 200mm THK. DOOR SHOULDER TO BE LEAD CONSULTANT
MAINTAINED UNLESS OTHER SPECIFIED.
MATCHLINE MATCHLINE 11. ALL MATERIALS AND COLORS SHALL BE
APPROVED BY THE ARCHITECT.
SEE: 1 / SEE: 1 / 12. WHERE NON-RATED/RATED & RATED/RATED PARTITIONS
KIA-B03-L&T-A_ KIA-B03-L&T-A_ INTERSECT THE PARTITION WITH THE GREATER
WD-L1-DWG-1155 2 WD-L1-DWG-1175 FIRERATING SHALL REMAIN CONTINUOUS THROUGHT SOM India LLC
2165 THE INTERSECTION TO MAINTAIN THE REQUIRED 14 Wall Street, New York, NY 10005
FIRERESISTANCE RATING FOR THE INTENDED SPACE
13. REFER FIINSHING SCHEDULE DWG NO. MEPF ENGINEER BAGGAGE CONSULTANT
1T54-11 129 m² KIA-B03-L&T-A_WD-XX-DWG-7501 to 7507 FIINSHING
TAG MARKED IN ENLARGED DETAIL DWG. ARUP LTD. BNP Associate s

4900
BHS CONTROL
14. REFER TO DOOR SCHEDULE DRAWINGS FOR DOOR 77 Water Street P.O. Box 32746

4100
RM
J GENERAL NOTES. New York, NY 10005 Abu Dhabi, UAE
15. CONTROL JOINS TO BE PROVIDED PER SPECIFICATIONS LIGHTING CONSULTANT LANDSCAPE

16. REFER TO FIREPROOFING DRAWINGS FOR THE BPI Grant Associates


TYPES AND EXTENTS OF APPLIED FIREPROOFING. 302 5th Ave, 12th FL 22 Milk Street
17. REFER TO LANDSCAPING DRAWINGS, New York, NY 10001 Bath, UK BA1 1UT
N25 FOR GARDEN DETAILS.

1000
1940 3205 3205 IT / SECURITY / PA / FAS SIGNAGE / WAYFINDING
18. REFER TO LANDSCAPING DRAWINGS FOR
REFER DRG NO:KIA-B03-L&T-A_BW-L1-SPD-1065 FORECOURT PAVING LAYOUT MBII MSD
1 19. EXACT LOCATION OF SLEEVE DETAILS IN RC WALLS 44 Mobile Drive 2 Young Place
1500
REFER STRUCTURAL DRAWING. Toronto, ON M4A 2P2 East Kilbride, GLA G75 0TD
2165 20. ALL DIMENSIONS FOR THE DOORS ARE ACTUAL DOOR OPENING WITHOUT
ANY SEALANTS / FINISH.
21. DOOR FRAME TO BE FLUSHED WITH EXTERIOR FINISH.
22. REFER LINTEL DETAILS & R.C. MULLIONS & TRANSOM AS PER
STRUCTURAL DRAWINGS- KIA-B03-L&T-C_NU-XX-
BIAL DESIGN
DWG-3000,3001,3002,3003,3004,3005
CHECKED BY APPROVED BY
23.THIS DRAWINGS TO BE READ IN CONJUCTION WITH RESPECTIVE MEP
I DRAWING/SHOP DRAWING.
24. ALL DIMENSIONS FROM TOP OF STRUCTURAL SLAB LEVEL.
25. ALL OPENINGS TO BE REVIEWED AND COORNDINATED WITH VENDOR GFC
SHOP DRAWINGS. ARCHITECTS & ENGINEERS:
26. VHT OPENING TO BE REVIEWED AND COORNDINATED WITH VENDOR
SHOP DRAWINGS. Engineering Design and Research Center (EDRC),
L&T Construction - Buildings & Factories.
27. CMU BLOCK WORK DETAILS AS PER SPECIFICATION
28. 1st BLOCK WORK COURSE SHALL BE FULL COURSE STARTING FROM SSL.
DESIGN BY DRAWN BY CHECKED BY APPROVED BY
29. REFER VHT GAD DRAWING FOR ELEVATOR OPENING.
30. SLAB INDICATES CONCRETE SLAB / DECK SLAB AS PER STRUCTURE.
31. FOR DECK SLAB LEVEL AND STEEL STRUCTURE REFER STRUCTURAL
N26 STEEL DRAWINGS. SSK GOPI DG DG
32. FHC & FEC SHALL BE COORDINATED AS PER VENDOR DETAIL
MAIN CONTRACTOR:
33. 20MM STRUCTURAL TOLERANCE WITH SEALANT / FIRE SEALANT
WHEREVER APPLICABLE.
34. ALL CUT-OUTS SHOWN IN TOILET AREA ARE INDICATIVE AND SHALL BE AS
PER APPROVED TOILET SHOP DWG'S
H
35. REQUIRED OPENINGS FOR FAS CABLING TO BE COORDINATE AS PER KEYPLAN
DRAWINGS
36. IN HORIZONTAL TRANSOM WHERE EVER ITS CONNECTING TO STEEL
T00 T10 T20 T30 T40 T50 T60 T70 T80
MEMBER, THE REBAR OF THE TRANSOM SHOULD BE PROPERLY WELDED
ACCORDINGLY T71
T01 T11 T21 T31 T41 T51 T61 T81

T02 T12 T22 T32 T42 T52 T62 T72 T82

T03 T13 T23 T33 T43 T53 T63 T83


T73

T04 T14 T24 T34 T44 T54 T64 T74 T84

T05 T15 T25 T35 T45 T55 T65 T75 T85

WALL LEGEND
T06 T16 T26 T36 T46 T56 T66 T76 T86

Wall Tag Description


G
N27 T07 T17 T27 T37 T47 T57 T67 T77 T87

P7 23-13 21 11 15 - 200mm THK T08 T18 T28 T38 T48 T58 T68 T78 T88

AAC WALL UPTO SLAB.


(NON FIRE RATED)
SEAL & SIGNATURE

ISSUED FOR
HATCH LEGEND SHOP DRAWING SUBMISSION.
SERVICE RECESSED FOR COORDINATION WITH
STRUCTURES & MEP CHECKED BY SIGN DATE CHECKED BY SIGN DATE
ARCHITECTURE FPS
CIVIL & STRUCTURAL PIPING
RCC PHE
ELECTRICAL
ELV SYSTEM AIRPORT SYSTEM
BLOCK WALL HVAC VHT
F

Revision Schedule
DOUBLE HEIGHT AREA
Revision Revision Revision
Number Description Date Issued by Issued to
N28 TOP OF LEVEL 3 - RETAIL
ISSUED FOR
0 APPROVAL
04.02. L&T BIAL
EARTH 2020

BLOCK WORK SHOWN INDICATIVELY

R.C. MULLIONS
E

N29

C N30

SEE: 1 / SEE: 1 /
KIA-B03-L&T-A_ KIA-B03-L&T-A_
WD-L1-DWG-1155 WD-L1-DWG-1175
MATCHLINE MATCHLINE
BIAPPA Commencement Certificate No:
MATCHLINE BIAAPA/TP1/CC/68/2018-19/843, Valid from 23-07-2019 till 22-07-2021
B
SEE: 1 / QRCODE
KIA-B03-L&T-A_
WD-L1-DWG-1176

DRAWING TITLE

LEVEL 1 - ARRIVAL
MEZZANINE- PART PLAN 65
BLOCK WORK SETTING OUT
A PLAN
DRAWING NUMBER

KIA-B03-L&T-A_BW-L1-SPD-1165
SCALE: 1:100 SHEET SIZE - A0

LEVEL 1 - ARRIVAL MEZZANINE - PART PLAN 65


1 SCALE: 1 : 100
CONSULTANT JOB NO : O18180

© Copyright Bangalore International Airport Limited

You might also like