Professional Documents
Culture Documents
WALL
EJ06(A)
NBA-06
KOTA STONE FLOORING AREA
A A
(FLOOR TO FLOOR CONDITION)
C C TOP / PLAN VIEW
A A
EJ02(A)
PJC-06 EJ02(C)
KOTA STONE FLOORING AREA PJCL-06
(FLOOR TO FLOOR CONDITION) KOTA STONE FLOORING AREA
TOP / PLAN VIEW (FLOOR TO CORNER CONDITION)
TOP / PLAN VIEW
DETAILS (BOD 5)
DETAILS (BOD 5)
286
286
KOTA STONE FLOORING (10MM)
KOTA STONE FLOORING (20MM)
MILL FINISHED
AL. EXTRUDED PLATE SCREED/ADHESIVE
SCREED/ADHESIVE
EJ06 (NBA-6)
26
10
SCREED
20
26
SCREED
RCC SLAB
RCC SLAB
MOISTURE BARRIER TO BE
INSTALLED
UNIFORM THROUGHOUT
LENGTH OF THE FLOOR
OUT TO BE CONTINUED
HEIGHT OF THE BLOCK
DETAILS (BOD 3)
152
152 RATED AREA ONLY
WIDTH OF THE BLOCK OUT WIDTH OF THE BLOCK OUT WIDTH OF THE BLOCK OUT WIDTH OF THE BLOCK OUT
UNIFORM THROUGHOUT
LENGTH OF THE FLOOR
REF BLOCK OUT DETAILS (BOD 1) REF BLOCK OUT DETAILS (BOD 3) EXPANSION JOINT GAP SIZE
OUT TO BE CONTINUED
OUT
DETAILS (BOD 1)
60
60
EJ06(A)
20
20
MOISTURE BARRIER TO BE NBA-06
60
60
INSTALLED NBA-06
20
20
MOISTURE BARRIER TO BE
INSTALLED
AT THE RCC SLAB
EJ02(C) BOD-3
PJCL-06 EJ02(C)
KOTA STONE FLOORING AREA PJCL-06
BOD-1 (FLOOR TO CORNER CONDITION) KOTA STONE FLOORING AREA
EJ02(A) (SEC C-C) (FLOOR TO CORNER CONDITION)
EJ02(A)
PJC-06
PJC-06
EJ06(B)
KOTA STONE FLOORING AREA
(FLOOR TO FLOOR CONDITION)
KOTA STONE FLOORING AREA
(FLOOR TO FLOOR CONDITION)
NBA-06
(SEC A-A)
VETRIFIED TILES FLOORING AREA
B B (FLOOR TO FLOOR CONDITION)
TOP / PLAN VIEW
PLASTERED WALL
WALL
DETAILS (BOD 6)
DETAILS (BOD 5)
B B
D D 286 286
26
26
10
10
SCREED SCREED
VETRIFIED TILES FLOORING AREA
(FLOOR TO CORNER CONDITION) RCC SLAB RCC SLAB
(FLOOR TO FLOOR CONDITION)
TOP / PLAN VIEW
TOP / PLAN VIEW
MOISTURE BARRIER TO BE
INSTALLED
AT THE RCC SLAB
FIRE BARRIER APPLICABLE
AT THE FIRE
152 RATED AREA ONLY 152
BOD-6
EJ06(B) EJ06(B)
NBA-06 NBA-06
VETRIFIED TILES FLOORING AREA VETRIFIED TILES FLOORING AREA
(FLOOR TO FLOOR CONDITION) (FLOOR TO FLOOR CONDITION)
(SEC A-A)
UNIFORM THROUGHOUT
LENGTH OF THE FLOOR
OUT TO BE CONTINUED
HEIGHT OF THE BLOCK
HEIGHT OF THE BLOCK
FLOORING ON TOP
OF EJ02 (PJC-6)
SCREED/ADHESIVE SCREED/ADHESIVE
VETRIFIED TILES FLOORING VETRIFIED TILES (10MM)
FLOORING ON TOP
SCREED/ADHESIVE PLASTERED WALL
KOTA STONE AND VETRIFIED TILES FLOORING AREA
SCREED SCREED PLASTERED WALL SCREED
SCREED/ADHESIVE OF EJ02 (PJCL-6)
WALL AT BOH
10
10
60
60
10
20
MOISTURE BARRIER TO BE
INSTALLED
RCC SLAB
MOISTURE BARRIER TO BE AT THE RCC SLAB
INSTALLED
RCC SLAB
AT THE RCC SLAB
152 152
FIRE BARRIER APPLICABLE 152
EXPANSION JOINT GAP SIZE EXPANSION JOINT GAP SIZE AT THE FIRE
152 EXPANSION JOINT GAP SIZE
AT THE STRUCTURE AT THE STRUCTURE RATED AREA ONLY
AT THE STRUCTURE
EXPANSION JOINT GAP SIZE
AT THE STRUCTURE
KANTAFLEX (INDIA) PVT LTD.
#113 Broadway Main Road,
EJ02(B) BOD-2 Chennai - 600108 , India.
PJC-06 EJ02(B)
VETRIFIED TILES FLOORING AREA PJC-06 EJ02(D) BOD-4 Telefax : 044-25361242,25361462.
(FLOOR TO FLOOR CONDITION) PJCL-06 EJ02(D)
(SEC B-B)
VETRIFIED TILES FLOORING AREA
(FLOOR TO FLOOR CONDITION) VETRIFIED TILES FLOORING AREA PJCL-06
Mail : kunal@kantaflex.in
(FLOOR TO CORNER CONDITION)
(SEC D-D)
VETRIFIED TILES FLOORING AREA
(FLOOR TO CORNER CONDITION)
www.kantaflex.in