KOTA STONE (20MM)

KOTA STONE (20MM) FLOORING ON TOP


FLOORING ON TOP OF EJ02 (PJCL-6) KOTA STONE
OF EJ02 (PJC-6) FLOORING (20MM) MILL FINISHED
PLASTERED WALL AL. EXTRUDED PLATE
KOTA STONE FLOORING KOTA STONE FLOORING EJ06 (NBA-6)

WALL

EJ06(A)
NBA-06
KOTA STONE FLOORING AREA
A A
(FLOOR TO FLOOR CONDITION)
C C TOP / PLAN VIEW
A A
EJ02(A)
PJC-06 EJ02(C)
KOTA STONE FLOORING AREA PJCL-06
(FLOOR TO FLOOR CONDITION) KOTA STONE FLOORING AREA
TOP / PLAN VIEW (FLOOR TO CORNER CONDITION)
TOP / PLAN VIEW

HEIGHT OF THE BLOCK


HEIGHT OF THE BLOCK

OUT REF BLOCK OUT


WIDTH OF THE BLOCK OUT

OUT REF BLOCK OUT


WIDTH OF THE BLOCK OUT
REF. BLOCK OUT DETAILS (BOD 5)
REF. BLOCK OUT DETAILS (BOD 5)

DETAILS (BOD 5)
DETAILS (BOD 5)
286
286
KOTA STONE FLOORING (10MM)
KOTA STONE FLOORING (20MM)
MILL FINISHED
AL. EXTRUDED PLATE SCREED/ADHESIVE
SCREED/ADHESIVE
EJ06 (NBA-6)

26

10
SCREED

20
26
SCREED
RCC SLAB
RCC SLAB

MOISTURE BARRIER TO BE
INSTALLED

UNIFORM THROUGHOUT
LENGTH OF THE FLOOR
OUT TO BE CONTINUED
HEIGHT OF THE BLOCK

HEIGHT OF THE BLOCK


AT THE RCC SLAB

OUT REF BLOCK OUT


FIRE BARRIER APPLICABLE
AT THE FIRE

DETAILS (BOD 3)
152
152 RATED AREA ONLY
WIDTH OF THE BLOCK OUT WIDTH OF THE BLOCK OUT WIDTH OF THE BLOCK OUT WIDTH OF THE BLOCK OUT
UNIFORM THROUGHOUT
LENGTH OF THE FLOOR

REF BLOCK OUT DETAILS (BOD 1) REF BLOCK OUT DETAILS (BOD 3) EXPANSION JOINT GAP SIZE
OUT TO BE CONTINUED

TO BE CONTINUED UNIFORM THROUGHOUT TO BE CONTINUED UNIFORM THROUGHOUT


HEIGHT OF THE BLOCK

HEIGHT OF THE BLOCK

EXPANSION JOINT GAP SIZE


OUT REF BLOCK OUT

LENGTH OF THE FLOOR LENGTH OF THE FLOOR AT THE STRUCTURE


AT THE STRUCTURE

OUT
DETAILS (BOD 1)

474 474 313 313


KOTA STONE FLOORING KOTA STONE (20MM) KOTA STONE FLOORING
FLOORING ON TOP
KOTA STONE (20MM) KOTA STONE FLOORING KOTA STONE FLOORING SCREED/ADHESIVE PLASTERED WALL SCREED/ADHESIVE PLASTERED WALL
OF EJ02 (PJCL-6)
OUT

FLOORING ON TOP SCREED/ADHESIVE SCREED/ADHESIVE SCREED SCREED


OF EJ02 (PJC-6)
SCREED SCREED
WALL WALL EJ06(A) BOD-5

60

60
EJ06(A)

20

20
MOISTURE BARRIER TO BE NBA-06
60

60

INSTALLED NBA-06
20

20

RCC SLAB RCC SLAB KOTA STONE FLOORING AREA


AT THE RCC SLAB (FLOOR TO FLOOR CONDITION) VETRIFIED TILES FLOORING AREA
RCC SLAB RCC SLAB (SEC A-A) (FLOOR TO FLOOR CONDITION)

MOISTURE BARRIER TO BE
INSTALLED
AT THE RCC SLAB

FIRE BARRIER APPLICABLE


AT THE FIRE
RATED AREA ONLY
FIRE BARRIER APPLICABLE
AT THE FIRE
152 152
RATED AREA ONLY
152 152
EXPANSION JOINT GAP SIZE EXPANSION JOINT GAP SIZE VETRIFIED TILES
EXPANSION JOINT GAP SIZE EXPANSION JOINT GAP SIZE AT THE STRUCTURE AT THE STRUCTURE FLOORING (10MM) MILL FINISHED
AT THE STRUCTURE AT THE STRUCTURE AL. EXTRUDED PLATE
EJ06 (NBA-6)

EJ02(C) BOD-3
PJCL-06 EJ02(C)
KOTA STONE FLOORING AREA PJCL-06
BOD-1 (FLOOR TO CORNER CONDITION) KOTA STONE FLOORING AREA
EJ02(A) (SEC C-C) (FLOOR TO CORNER CONDITION)
EJ02(A)
PJC-06
PJC-06
EJ06(B)
KOTA STONE FLOORING AREA
(FLOOR TO FLOOR CONDITION)
KOTA STONE FLOORING AREA
(FLOOR TO FLOOR CONDITION)
NBA-06
(SEC A-A)
VETRIFIED TILES FLOORING AREA
B B (FLOOR TO FLOOR CONDITION)
TOP / PLAN VIEW

VETRIFIED TILES (10MM)


FLOORING ON TOP
OF EJ02 (PJC-6) VETRIFIED TILES (10MM)
FLOORING ON TOP
VETRIFIED TILES FLOORING VETRIFIED TILES FLOORING OF EJ02 (PJC-6)

PLASTERED WALL

WALL

HEIGHT OF THE BLOCK

HEIGHT OF THE BLOCK


OUT REF BLOCK OUT

OUT REF BLOCK OUT


WIDTH OF THE BLOCK OUT WIDTH OF THE BLOCK OUT
REF. BLOCK OUT DETAILS (BOD 6) REF. BLOCK OUT DETAILS (BOD 5)

DETAILS (BOD 6)

DETAILS (BOD 5)
B B
D D 286 286

EJ02(D) VETRIFIED TILES FLOORING (10MM) VETRIFIED TILES FLOORING (10MM)


EJ02(B) MILL FINISHED
PJCL-06 AL. EXTRUDED PLATE SCREED/ADHESIVE SCREED/ADHESIVE
PJC-06 EJ06 (NBA-6)
VETRIFIED TILES FLOORING AREA

26

26
10

10
SCREED SCREED
VETRIFIED TILES FLOORING AREA
(FLOOR TO CORNER CONDITION) RCC SLAB RCC SLAB
(FLOOR TO FLOOR CONDITION)
TOP / PLAN VIEW
TOP / PLAN VIEW
MOISTURE BARRIER TO BE
INSTALLED
AT THE RCC SLAB
FIRE BARRIER APPLICABLE
AT THE FIRE
152 RATED AREA ONLY 152

EXPANSION JOINT GAP SIZE EXPANSION JOINT GAP SIZE


AT THE STRUCTURE AT THE STRUCTURE

BOD-6
EJ06(B) EJ06(B)
NBA-06 NBA-06
VETRIFIED TILES FLOORING AREA VETRIFIED TILES FLOORING AREA
(FLOOR TO FLOOR CONDITION) (FLOOR TO FLOOR CONDITION)
(SEC A-A)

UNIFORM THROUGHOUT
LENGTH OF THE FLOOR
OUT TO BE CONTINUED
HEIGHT OF THE BLOCK
HEIGHT OF THE BLOCK

WIDTH OF THE BLOCK OUT WIDTH OF THE BLOCK OUT


OUT REF BLOCK OUT
UNIFORM THROUGHOUT
LENGTH OF THE FLOOR

REF BLOCK OUT DETAILS (BOD 2)


OUT TO BE CONTINUED

TO BE CONTINUED UNIFORM THROUGHOUT


HEIGHT OF THE BLOCK

HEIGHT OF THE BLOCK

WIDTH OF THE BLOCK OUT


OUT REF BLOCK OUT

LENGTH OF THE FLOOR


DETAILS (BOD 4

TO BE CONTINUED UNIFORM THROUGHOUT


WIDTH OF THE BLOCK OUT LENGTH OF THE FLOOR
DETAILS (BOD 2)

474 474 REF BLOCK OUT DETAILS (BOD 4)


OUT 313
VETRIFIED TILES (10MM)
VETRIFIED TILES FLOORING VETRIFIED TILES FLOORING
313 VETRIFIED TILES FLOORING FLOOR EXPANSION JOINT DETAILS FOR
OUT

FLOORING ON TOP
OF EJ02 (PJC-6)
SCREED/ADHESIVE SCREED/ADHESIVE
VETRIFIED TILES FLOORING VETRIFIED TILES (10MM)
FLOORING ON TOP
SCREED/ADHESIVE PLASTERED WALL
KOTA STONE AND VETRIFIED TILES FLOORING AREA
SCREED SCREED PLASTERED WALL SCREED
SCREED/ADHESIVE OF EJ02 (PJCL-6)
WALL AT BOH
10

10
60

60

10

RCC SLAB RCC SLAB SCREED


60

WALL EJ02 (PJC/PJCL-6) & EJ06(NBA-6)


60

20

MOISTURE BARRIER TO BE
INSTALLED
RCC SLAB
MOISTURE BARRIER TO BE AT THE RCC SLAB
INSTALLED
RCC SLAB
AT THE RCC SLAB

FIRE BARRIER APPLICABLE


AT THE FIRE
RATED AREA ONLY DATE : 29.11.2020

152 152
FIRE BARRIER APPLICABLE 152
EXPANSION JOINT GAP SIZE EXPANSION JOINT GAP SIZE AT THE FIRE
152 EXPANSION JOINT GAP SIZE
AT THE STRUCTURE AT THE STRUCTURE RATED AREA ONLY
AT THE STRUCTURE
EXPANSION JOINT GAP SIZE
AT THE STRUCTURE
KANTAFLEX (INDIA) PVT LTD.
#113 Broadway Main Road,
EJ02(B) BOD-2 Chennai - 600108 , India.
PJC-06 EJ02(B)
VETRIFIED TILES FLOORING AREA PJC-06 EJ02(D) BOD-4 Telefax : 044-25361242,25361462.
(FLOOR TO FLOOR CONDITION) PJCL-06 EJ02(D)
(SEC B-B)
VETRIFIED TILES FLOORING AREA
(FLOOR TO FLOOR CONDITION) VETRIFIED TILES FLOORING AREA PJCL-06
Mail : kunal@kantaflex.in
(FLOOR TO CORNER CONDITION)
(SEC D-D)
VETRIFIED TILES FLOORING AREA
(FLOOR TO CORNER CONDITION)
www.kantaflex.in