You are on page 1of 1

LEGENDS:

WM WATER METER

CHECK VALVE

GATE VALVE

CLEAN OUT
A B C D E F G H I J K
SSO SOIL STACK

FLOOR DRAIN
FD

30.00 DOWN SPOUT


DS
7.40 3.35 1.50 1.50 1.50 2.50 4.45 4.00 1.50 2.30
VSTR VENT STACK THROUGH ROOF

1 CB
CB CATCH BASIN

2.00

2.00
SV SEPTIC VAULT

2
DS

FD

CO
FD CO
DS
CB WC WATER CLOSET
UTILITY WC
WC WC

LAVATORY

2.50

2.50
MALE FEMALE STORAGE LOUNGE
LAV
FD FD FD

TOILET
TOILET TOILET ROOM
LAV LAV OFFICE LAV
UP
RCS RAINWATER CATCHMENT SYSTEM
3 CB
DS

SANITARY LINE
1.50

1.50
6 EMERGENCY SERVICE
EXIT EXIT

4 SERVICE
EXIT
FD

CO
RECLAIMED WATER LINE
FD

2.20
SINK
TOILET FD
ADMIN
RU RISER UP
PARKING AREA RECEPTION
KITCHEN
DESK
7
FD
CO
RD RISER DOWN
COUNTER
6.30

COFFEE SHOP
HB HOSE BIBB
20.00

20.00
LOBBY WAITING AREA

4.10
SV 8 NOTES & SPECIFICATIONS
DINING
AREA UP 1. ALL PLUMBING WORKS HEREIN SHALL BE EXECUTED ACCORDING
TO THE REQUIREMENTS OF THE PHILIPPINE NATIONAL PLUMBING
5 CB
DS DS
CB CODE AND THE RULES AND REGULATIONS OF THE EXISTING
LOCAL CODES AND ORDINANCES.
1.50

1.50
2. REFER TO ALL ELECTRICAL, STRUCTURAL, AND ARCHITECTURAL,
PLANS AND SPECIFICATIONS AND INVESTIGATE ALL POSSIBLE
INTERFERENCES AND CONDITIONS AFFECTING THE PLUMBING
WORKS.
TO THE NEAREST SEWER

MOTORCYCLE
3. IT IS NOT INTENDED THAT THE DRAWINGS SHALL SHOW EVERY
PIPE LINE

PARKING
PIPE FITTING, VALUE, APPLIANCES OTHER FURNISH AND INSTALL
TO THE NEAREST SEWER

1 2 3 4 IF NECESSARY ALL SUCH ITEM. WHETHER SPECIFICALLY


PWD PWD
PIPE LINE

PARKING AREA MENTIONED OR NOT INDICATED ON DRAWINGS TO COMPLETE


5.00

5.00
PARKING PARKING THE SYSTEM IN ACCORDANCE WITH THE BEST PRACTICE OF THE
1 2 3 4 5 TRADE AND TO THE SATISFACTION OF THE ARCHITECT/OWNER.

4. WHERE A BRANCH SERVING MORE THAN ONE FIXTURE INCREASE

TO THE NEAREST SEWER PIPE LINE


THE SIZE OF A BRANCH INCREASE BEFORE PROPORTIONATELY
DONE.

5. PROVIDE MATERIALS THAT ARE NEW AND THAT CONFORMS WITH


THE STANDARD OF UNDER WRITERS LABORATORIES
1.20

1.20
INCORPORATED.
SIDEWALK SIDEWALK SIDEWALK

6 6. SUBMIT SAMPLES OF MATERIAL FOR APPROVAL AS REQUIRED BY


THE ARCHITECT.

7. CONFORM ALL APPLICABLE PIPES FOR APPROVAL AS REQUIRED


1.20 5.00 1.20 9.00 11.30 2.30 BY THE ARCHITECT.

30.00 8. INSTALL ALL PLUMBING FIXTURES FREE AND OPEN IN MANNER OF


ACCESS FOR CLEANING, FURNISH BRACKETS, CLEATS AND
ANCHORS REQUIRED TO SUPPORT THE FIXTURES RIGIDLY IN
PLACE.

GROUND FLOOR STORM DRAINAGE AND PLUMBING LAYOUT PLAN


SCALE 1:100 MTS.

SCHOOL: MEMBERS: REPUBLIC ACT 9266, SECTION 33 INSTRUCTOR: COURSE/CODE: PROJECT TITLE:

CAGANG, NARCISO JR. Drawings and specifications and other contract documents
duly signed, stamped or sealed as instruments of service,
AR 213 (2126)
CALIMLIM, REVIN GRACE are the intellectual property of the ARCHITECT, whether the
object for which they are made is executed or not. It shall be
P
UNIVERSITY OF MINDANAO CASUMPA, DHELL unlawful for any person to duplicate or to make copies of the
said documents for use in the repetition of and for other
AR. JAIME B. GONZAGA, UAP PROPOSED 2-STOREY PLUMBING PROJECT
1
COMORA, LEAN MIGUEL R. projects or buildings, whether executed partly or in whole, BUILDING UTILITIES 1 - PLUMBING
without the written consent of the ARCHITECT or AUTHOR
RACHO, MARIANNE JOYCE C. of the said documents. AND SANITARY