1.90 1.

90

INLET PIPE
TO PUBLIC 0.75 0.375 0.375 0.75 0.375 0.375
SEWER MANHOLE MANHOLE MANHOLE

C.O.
C.O.
OUTLET PIPE
AIRGAP
C.O.
TO PUBLIC
4" CHB WALL W/10mm SEWER
MH. MH. MH.
REBARS @ EVERY
DIGESTIVE LEACHING
LAYER OF CHB CHAMBER CHAMBER
EFFLUENT TO
PUBLIC SEWER

SEPTIC TANK PLAN


SLUDGE (2% SLOPE
SCALE 1:25 MTS
@FFL.)

SPECIFICATIONS:
4" REINFORCED 1.0 GRADES AND HORIZONTAL PIPINGS
RUN ALL HORIZONTAL PIPINGS IN PERFECT ALIGNMENT & AT A UNIFORM GRADE OF
NOT LESS THAN (2%) TWO PERCENT
CONC. SLAB ON 2.0 CHANGE IN DIRECTIONS
ALL CHANGE IN DIRECTIONS SHALL BE MADE BY THE APPROPRIATE USE OF FORTY
COMPACTED
BARS SPACED BENDS WHEN THE CHANGE OF FLOW IS FROM HORIZONTAL AND VERTICAL, A SINGLE

GRAVEL FILL 1/8 BEND COMBINATION MAY BE USED ON WASTE LINES, TEES AND CROSSES MAY BE
USED ON VENT PIPES
@0.30moc. 3.0 PROHIBITED FITTINGS

BOTHWAYS NO DOUBLE HUB OR DOUBLE TEE BRANCH SHALL BE USED ON HORIZONTAL SOIL OR

SEPTIC TANK DETAILS WASTE LINES, THE DRILLINGS AND TAPPINGS OF HOUSE OF DRAIN WASTE OR VENT
PIPE AND USE OF SADDLE HUB AND BENDS ARE PROHIBITED

SCALE 1:25 M 4.0 SLEEVES


PROVIDE PIPE SLEEVES AT WALLS, COLUMNS OR SLABS ONE SIZE BIGGER THAN THE
ACTUAL LINES PASSING THROUGH WALLS OR SLABS TO PROTECT PIPES FROM
BREAKAGE

MH. INLET 0.55


5.0 PIPE CLEAN OUTS
CLEAN-OUTS ARE REQUIRED UNDER THE FOLLOWING CONDITIONS:
A. EVERY CHANGES IN HORIZONTAL DIRECTIONS EXCEEDING TWENTY TWO

PIPE B. ONE AND ONE HALF METERS (1.50) INSIDE THE PROPERTY LINE BEFORE THE
HOUSE DRAINAGE CONNECTION
C. EVERY FIFTEEN METERS (15.00 m) IN HORIZONTAL RUN OF PIPE.

4" CHB WALL 0.45 D. AT THE END OF ANY HORIZONTAL PIPE LINE

6.0 SEPTIC VAULT


A. THE DIGESTION CHAMBER OF SEPTIC VAULT MUST BE WATER PROOFED
B. NOT LESS THAN 0.30 m OF AIR SPACE BETWEEN THE TOP OF THE SEWAGE
AND THE UNDER PART OF THE VAULT ROOF SLAB
C. NO SEPTIC VAULT SHALL BE CONSTRUCTED UNDER THE BUILDING

7.0 ALL PLUMBING WORKS SHALL BE DONE IN ACCORDANCE WITH THE PROVISION OF

CATCH BASIN
THE NATIONAL PLUMBING CODE AND THE REQUIREMENT OF THE LOCAL PLUMBING
INSPECTION OFFICE AND PERTINENT PROVISIONS OF THE EXISTING LOCAL BUILDING

PLAN & SECTION MH. 8. 0


CODE

ALL PLUMBING WORKS SHALL BE DONE BY A LICENSED MASTER PLUMBER AND A


0.45 PLUMBING CONTRACTOR
0 P-3 IS THE STANDARD DETAIL OF SEPTIC VAULT
SCALE 1:25 MTS 0 VERIFY ACTUAL LOCATION OF STREET DRAINAGE AND WATER SOURCE FOR
CONNECTION

9.0 PROVIDE WATER METER IF APPLICABLE


PREPARED BY CERTIFIED BY: PROJECT TITLE: APPROVED BY SHEET CONTENT SHEET NO.
IMPORTANT:

A R C H I T E C T AR. RAMONSITO YANDALL Drawings and specifications duly signed,


stamped or sealed as instrument of service,

JUSTINE JAMES V. GARINGANAO REGISTERED MASTER PLUMBER are the property of the architect, whether the object BATIDUAN-BARBON RESIDENCE: SEPTIC TANK PLAN AND SECTION
P-3
for which they are made is executed or not.

PLANNER - DESIGNER
It shall be unlawful for any person without the
written consent of the architect or author of the said
A PROPOSED TWO STOREY RESIDENTIAL PROJECT MRS. CHIRADEE B. BATIDUAN CATCH BASIN PLAN AND SECTION
documents, to duplicate or to make copies
#25 ST. MARTIN STREET, SUNTAL VILLAGE II, CIRCUMFERENTIAL RD.,
for use in repetition of the other projects or buildings, GENERAL NOTES
BRGY TACULING, BACOLOD CITY, NEGROS OCCIDENTAL whether executed partly or in whole.
CP: 090650663962 / 09491138704 PROJECT LOCATION: BRGY. 1, MUNICIPALITY OF E.B. MAGALONA, OWNER/REPRESENTATIVE
RA 9266 - 17 Mar 2005
NEGROS OCCIDENTAL, PHILIPPINES