You are on page 1of 13
SV 300 Ventilator Compact yet powerful ¥ Adaptive to different clinical environment ¥ Simple, ease of use 4 ¥ Comprehensive ICU ventilation performance ¢ v Reliable latest hardware platform & = Pr - t oy eo Tmindray Contents Ca larie-lieliela) = 2 em ww conn mindray Gas and Power supply requirement Terria TenaY Tara ctr oe ane vp =r tae i ae a aie RT as oO Sa Saran Tow pressure wxyzen inlet .Vv~ Preerore ceuae “Lesetban 1ODKPa ‘Masienum How 15Linia(STPD) Connector CPC que connector Tl emttamen Contes mindray Preparations Tools List Allen Key Set Iset Philips Screwdrive Iset ™ Maintain Passwords User password 1234 Service password 1118 mindray Gas and Power supply requirement Gas type Toput voltage 100 280°) Teput frequency “S050 Te Tp arreat Bre LIN Base T3SABOAE Teput voltage ra Tapa treat 1a. ‘Op Pressure range 220 0 GOD LP Rated Now requrcecat ‘Noles than (20a (STP) coe a aa cy Gemmengee easeerer ‘Maxirmum flow A5Limin(STPD) a gil ote mindray Preparations Tools List Allen Key Set Iset Philips Screwdrive Aset i Maintain Passwords User password 1234 Service password 1118 Prva mindray Installation — Main Unit a - Place the main unit on the trolley 2 etn imew comarea mindray Installation — Main Unit Power cord HPO connection LPO connection (C-Power cord retainer) (NIST or DISS) (CPC quick connector) am emtienaisanas: mindray Installation - Support Arm 0D —Up & down adjustment | F —Bending angle adjustment G — Back & forth adjustment Ae mindray Installation - Breathing Circuit ater traps should be at the lowest point of the tim. iar should be in cb Installation - Breathing Circuit a JIKESH330 Humidifier Connections - Ifa thermometer comes with humidifier, it should be installed at inspiratory limb close to ¥-piece 4 Inspiratory limb i Adapter 4 gtx Adapter |——“ | chamber 2— 3. Human Tees moment mindray Installation - 02 sensor - Make sure the 02 sensor is plugged in horizontally - ©2 sensor must be calibrated after installation Installation - Backup Cylinder rede E Cylinder order code Tare ‘Nominal contents (ites 680 Valve outlet connection Pin-index Yalve outlet specification 150 404 Valve operation key Dimensions" Lx O (mm) 865 x 102 Water capacity (lites) a7 ‘Nominal weight full (kg) 65 *Cylinder is not available from Mindray = 082-001927-00 Pressure regulator 14Mpa (for cylinder), can be ordered from Mindray SH 61 Any Cie mindray Test After Installation 4 System settings 2 System check 3 Ventilation check z 2 ‘Set ©2 supply type (22% calibration if ©2 sensors installed For high altitude area, altitude compensation is necessary Check turbine, airiO2/expirtory flow sensor, pressure sensor, valves and O2 sensor works well Check system leakage. compliance and airway resistance. To confirm ventilator works normally, and no alarm, To confirm the measured pressure or tidal volume are consistent with settings After installation After installation | repair / visit After installation / repair / visit mindray System Settings —- 02 Supply Type im piece oe + Low pressure O2 + <100Kpa Om ty Contes mindray System Settings — Altitude System Settings - 02% Calibration Ls] AN, samen 5 System Check 35 etott aw conan mindray 3 rae Cate Ventilation Check - Check Volume Control Ventilation (V-A/O) mindray Check Volume Control Ventilation (V- A/Q) Steps 1. Make sure that the Supply pressure is| normal and that the breathing circuit are correctly connected. 2. Connect a 2L bag as the test lung to the Y piece in the patient circuit. 3)/Select V-AIC as the ventilation mode. 4. Set the following combinations of TV (tidal volume) and Rate respectively: (150ml, 19BPM), (300mI, 158PM), (600ml, 158PM) ‘and (900ml, 158PM). 5. Setothers to the defaults. 6. Record the TVireading in each setting when it is stable. S00” "oa mindray + The difference between the TVi reading and set value does not exceed 10ml + 10% setting value + If you set TV=600mi. -Max accepted tolerance will be 10+600"10%=70ml, i.e. acceptable measured TVi is 530-670mI. 41 east we conse mindray Steps 1. Make sure that the Supply pressure is normal and that the breathing circuit are correctly connected. 2. Connect a 2L bag as the test lung to the Y piece in the patient circutt 3 Select P-A/C as the ventitation mode. 4. Set ihe following combinations of Pinsp, Rate and PEEP respectively: (1 emH20, 19BPM, OFF), (1ScmH20, 12BPM, ScmH20), (20cmH20, 10BPM, 8¢mH20). 5. Set others to the defaults. 6. Record the displayed Peak and PEEP values in each setting stabilized status. eee mindray Check Pressure Control Ventilation (P- A/C) Pass criteria: Peete eee Ppeak and the set Pinsp (Na esasp het rs fae ae ee oc Pra een tot fem Drie Pees ae acd Pir Example: - If you set “\Pinsp=15¢emH20, PEEP=5emH20. - For Ppeak, expected value is 15+5 = 20cmH20. Max accepted tolerance will be 2+20*5%=3cmH20, ie. acceptable measured Ppeak is 17~23emH20. - For PEEP, expected value is 5cmH20. Max accepted tolerance will be 2+5*5%=2.1 emH2O, Le. acceptable measured PEEP is 2.9~7.1cmH20_ csi weew cee mindray Operation Notes © Do not use antistatic or conductive masks or breathing hoses. They can cause burns if working with high frequency electrosurgical equipment. 1 Re-do system check each time when accessories or components like hose, humidifier, and filter are replaced. Adding accessories or other components to the ventilator can increase system inspiratory and expiratory resistance | Humidifier connector must be lower than the ventilator’s breathing connectors and the patient. To reduce the risk of fire, do not use a low-pressure O2 supply that delivers a flow greater than 15L/min, < semayonmen mindray

You might also like