You are on page 1of 8
Water Treatment Chemicals Za iF ABHITECH ENERGYCON LIMITED Introduction Abhitech Energycon Limited is an industry leading supplier of high quality water and waste water treatment chemicals, specialty chemicals, water testing kits, corrosion and Bio coupons etc. Through our commitment to innovation, access to cutting-edge technology, quality products and service excellence through highly skilled technical people, we deliver significant advantage to our clients. Abhitech’s range of high quality water treatment chemicals have been developed to significantly improve the management of the key problems associated with water treatment, Our Range includes corrosion inhibitors, Antiscalant, PH adjuster, oxidizing and Non-oxidizing biocides, condensate line treatment, oxygen scavenger, descaling compounds, De-alkalizer etc. Abhitech Energycon has gained an excellent reputation as a partner ready to meet challenges of rapid delivery, competitive price and best technical support and services. Based on the technical details and water analysis shared by clients, we submit ‘our best treatment solutions at most competitive offers. Objective Abhitech Energycon Limited, have a common objective of proving our competency in providing our customers with the result oriented products and services with a special thrust on quality. In our association with customers, our motive is to satisfy the customer needs while upholding the technical standards of excellence and innovation. Our aim is to strengthen ‘our ties with the customer to develop 2 relation more than thatof a customer and supplier. ‘Our long time presence in India and abroad, vast experience and unique position allows us to offer the best of our technical ‘expertise and specialty products of international standards to our clients. ‘We are committed to work with customers in a very individualized and responsive manner to ensure understandings of their needs to offer the best solutions. Boiler Water Problems Water used to generation of steam contains various impurities, the most typical being compounds of calcium, magnesium, silica and iron. In an system where impurities are allowed to reach excessive concentrations, steam quality can be impaired. In addition, hardness salts can precipitate from the boiler water to form sludge and eventually scales, which deposits on the internal surfaces of the boiler tubes. The result: a serious loss of boiler efficiency, and possibly boller tube failure. ‘Scale is a buildup of solid material formed on internal tube surfaces when the concentration of impurities in the boiler water exceeds their solubilty limit and precipitation occurs, Corrosion is the destruction of a metal by electromechanical reaction with its environment. In boiler systems, that environment includes hot water with a low pH or slightly acid condition and some degree of oxygen entrainment. Those conditions are ideal for corrosive action. Removal of carbon dioxide and oxygen from boiler feed water is essential in preventing boiler-system corrosion. Foaming and Carryover are caused due to high dissolved solids and caustic alkalinity in combination with leakages, load changes and organic matter. Boiler Water Solution Control of boiler-water chemistry, before and after the water enters the steam generating system, is vital to efficient ‘operation, acceptable maintenance costs, and satisfactory equipment service-life. All-In-One Programs - Liquid blends of alkalinity bullders/polymers and sulfite designed as one single drum and advanced treatment for high pressure boilers (AVT). ‘Oxygen Scavengers - Products in this group represent inorganic and organic catalysed oxygen scavengers. These products cover all pH ranges and concentrations, and are available‘ liquids and’ powders. Also, more effective products for boiler lay-ups are available. Alkalinity Builders Liquid alkalinity builds to pfevent acid attack and amine based product with higher distiBltion fatio for condensate treatment. Cooling Water Problems Corrosion, deposition, and microbiological growth in cooling water system can lead to flow restrictions, reduced operating efficiency, high maintenance costs, and unscheduled outages, ‘Scaling and Fouling are caused by calcium carbonate in addition to calcium phosphate, calcium sulfate, silica with mud andsit. Corrosion has many forms and many causes. In cooling systems, water velocity, dissolved solids, and continual aeration provide optimum conditions for continued corrosion. The type of attack can usually be related to the cause. Certain ‘microbiological organisms ike SRB and IRB in cooling water system produce another type of attack. Microbiological Growth/ biofouling in cooling system are dynamic environments and as a result there is frequently ‘something different or unexpected happening that influences the proliferation of microorganisms. Cycles VS Makeup Water Cooling Water Solutions Corrosion and Scale Control Programs - Tracer Based Stabilized Phosphate Programs ‘Neutral pH-Phosphate and halogen resistant technology Alkaline Zinc / Organic Programs Molybdate based all Organic Programs ‘Closed system treatment ‘Once through system treatment Focus of the technology has been on the utilization of more thermally stable inhibitors, widening application of crystal ‘modifiers with solubilzing inhibitors, and use of chemicals with new molecular structures, Microbiological Control Programs ‘Oxidizing Non-oxidizing Biodispersants ‘The introduction of glutaraldehyde and increased use of isothiazolinone and dibromo-nitrilo-propionamide (DBNPA), along with triazine an outstanding algicide lead the newcomers in this category for low-toxicty, high-pH cooling water. While quaternary compounds provide good macro-organism protection. To help maintain the reliability and performance of your cooling system. We offers a ful ine of treatment programs that work at various pH levels and with different water chemistries, Regardless of your system type, we has a solution. Cost Effective Solutions for Smooth Operation of Plant © Cooling Water Solutions ‘Antiscalants for reducing scale deposition Corrosion Inhibitors for Corrosion protection Dispersants for reducing fouling deposition Oxiizing & Non oxidizing Biocides " roe Boller Water Solution Antiscalnts for reducing scale deposition a we Corresion Inhibitors for Corrosion protection“ ae 8 PH Adjusters Passivation chemicals, © ROWater Treatment Chemicals Food Grade Antiscalants @ West Water Treatment Chemicals Coagulant Flocculants Microbes / Micro-organisms Scale Prevention - Products in the group consists of the newest technological advances. All polymer and phosphate technologies for effective scale inhibition, crystal modification and sludge dispersion to ensure clean surfaces. Condensate Treatment - Neutralizing and Filming amines are provided in a wide variety, utlizing formulations based on standards amines. Recommended ABMA & ASME Boiler Water Limits Boller Feed Water ron (ppm Fe) otal Hardness (ppm caco3) Silica (ppm sio2) specitie conductance {micromhos/em) (unneutralized) 301-480 0.100 0.050 0.300 0.300 150 90 "7000 1-600 0.030 0.200 40 751-900 ‘901-1000 0.020 0.020 1001-1500 0.010 1501-2000 ‘ano Technical Services Iw SL Regular technical services are effectively provided through well trained field chemist/technical executives for monitoring the system: a ‘To inspect the system undergoing treatment & carry out field analysis of water and its various parameters. ‘To prepare reports and discuss the findings for corrective measures. ‘To give training to the operators for on spot analysis of water & maintaining the records, ‘To check the operating log books for ensuring optimum chemical usage. To discuss the performance and problems, if any, with the concerned authority. ‘To bring reference samples of treated water at R&D lab for preparation of status report etc, ‘To discuss stock position and arrange its timely supply to avoid uninterrupted treatment. gaoo0a0qa Abhitech’s Global Presence o — ZONAL OFFICES = OVERSEAS OFFICES : ABHITECH ENERGYCON LIMITED A/1020, Oberoi Garden Estates, Chandivali, Mumbai - 400 072 (INDIA) 4 Tel.: +91-22-2847 9999 Fax: +91-22-2847 9988 2 hydroclean@abhitechmail.com abhitech@abhitechenergycon.com ‘wwwabhitechenergycon.com ») MUMBAI | DELHI | KOLKATTA | BENGALURU | RAIPUR CZECH REPUBLIC | EGYPT | GHANA | INDONESIA | SLOVAKIA | SRILANKA

You might also like