You are on page 1of 16

PCXSMT1604B

Ceiling cassette

Ceiling convertible
Ceiling exposed

Ceiling concealed

Light Commercial
Product Catalogue

HEATPUMP [50Hz] 220-240V


1
MORE COMFORT WITH LESS ENERGY
An inverter air conditioner utilizes intelligent controls that regulates the speed of compressor motor
to provide the required cooling /heating with low power consumption. Comfort is achieved with
precise control of cooling / heating requirements, preventing temperature swings.

Advantages of Inverter Technology

● Superior Comfort ● Powerful Operation ● Higher Efficiency ●Energy Savings

While fixed speed (non-inverter) systems operates by compressor start-stop cycles, this consumes
much more energy and room temperature variance is higher.

Hot

2
Room Temperature

1 1
Inverter
Comfortable 2
ter
ver
-I n
on

Cold Output Power of Air Conditioner


Inverter model Requires shorter period to reach Requires a longer period to reach the
1
Non-inverter model 1
air conditioner the required room temperature.
air conditioner required room temperature.
2 Minimal temperature fluctuation to achieve 2 Temperature of room fluctuates out
comfortable room temperature at all times. of the comfort zone.

In a non-inverter air conditioner, the on-off compressor switches on to maximum power when the room is
hot and switches off when the required room temperature is achieved. This results in an inefficient use of
energy.
In an inverter air conditioner, the variable speed compressor changes its speed to match the required room
temperature. This ensures an efficient use of energy and higher savings.

1
What is Inverter Technology?
Inverter air-conditioning technology is the solution for superior comfort, higher
efficiency and better energy savings. Daikin’s inverter technology lowers energy
consumption up to 50%. Its powerful action allows the desired temperature to be
achieved quickly, maintaining precise temperature to ensure a consistent level
of comfort.

Daikin DC Swing Compressor Swing bush


Cutting-edge technology for Refrigerant gas
precise control with silent
operation.

Energy savings are realized,


eliminating the friction and
the leakage of refrigerant
gas.

Piston incorporating
blade and roller

Flexible performance, rapid response time


After quickly reaching set temperature, the inverter system Room
Temperature
constantly adjusts and fine-tunes the cooling capacity to Precise & Stable Temperature Control

prevent undesired temperature swings. Set


Temperature

Room comfort level is constantly maintained even when


the number of people in the room increases or decreases.
Time

Inverter System Conventional System

Low starting current


With the ability to modulate the compressor
speed, inverters are designed to operate with
“soft start” feature. The compressor motor Flexible installation
does not require high current during start up. The extended piping length promotes flexible
installation.

Model Pre-charged Max. length Max. height


length (m) (m) (m)
Conventional air RX25DGXV1 7.5 15 10
conditioner RX35DGXV1 7.5 15  10
Running Current

• High starting current RXN50CGXV1 7.5 30 10

• Frequent on/off cycle RXN60CGXV1 7.5 30 10


RZQ71CGXV1 7.5 50 30
RZQ100FGXV1 7.5 75 30
RZQ100FGXY1
RZQ125FGXV1 7.5 75 30
RZQ125FGXY1
Inverter air conditioner RZQ140FGXV1
RZQ140FGXY1 7.5 75 30
• Low starting current
• Smooth operation Note:
Additional refrigerant is required if the piping is longer than the pre-
charge length. For details, kindly refer to the installation manual.

2
Ceiling Cassette 3x3, 2x2 (50Hz)

RX25/35DGXV1

FCQ50/60/71/100/125EXV1 RZQ71CGXV1
Wireless controller
BRC52A

RXN50CGXV1

FFQ25/35/50CXV1
Wired controller
BRC51A
(optional)

RZQ100/125FGXV1
RXN60CGXV1 RZQ100/125FGXY1

• Multi comfort - 3 air swing pattern control (FCQ-E) • Low height design
• Compact design (FFQ-C) • Built-in high head drain pump and water flow switch
• Fresh air intake • Sleep function in cool and heat modes
• Optimum air discharge • Auto random restart with last-state-memory
• Superior sound level • Self-diagnosis features
• Branch duct connection • NIM-abled

Modern & Elegant Panel Multi Comfort - 3 Air Swing Pattern Control
The FCQ-E series is designed with unique “round” To increase the comfort level of the air conditioned area
side contour and new LED light location. The rotatable using FCQ-E series, the system had been built in with
intake grill promotes uniform installation as well. three different types of air flow pattern to suit different
requirements.
* The default setting is pattern 1. The air swing pattern
can be selected via wireless controller.

Standard Setting
Louver is set to swing at the maximum angle for
gentle drafts.

10˚ 10˚

65˚
Pattern 1 65˚

Draft Prevention Setting


With the aid of Coanda effect, direct draft which
may lead to discomfort can be avoided.

10˚ 10˚

40˚ Pattern 2 40˚

Soil Prevention Setting


Low Height Design Even distribution of cooling whilst ensuring ceiling
The FCQ-E series unit height as low as 265mm for to be kept spotless.
installation convenience.

265mm 350mm
30˚ 30˚
Pattern 3
65˚ 65˚

3
Ceiling Cassette 3x3, 2x2 (50Hz)

Superior Sound Level Compact Unit Design


The FCQ-E series is able to achieve exceptional low The FFQ-C series body dimension is only 570mm x
noise by adaption of Daikin’s turbo fan technology. With 570mm which can easily fit into a 600mm ceiling grid.
4 selectable fan speeds, users are given more choices.
In Quiet mode, the sound pressure level can be as low
as 23dBA.
600mm
600mm

Longitudinal vortices
generated along serration
edges accelerate mixing
turbulence which reduces 570mm 570mm
vortex shedding noise.

Optimum Air Discharge and Air Swing


Combining 4-way air discharge and large discharge
area on each side, the ceiling cassette promotes uniform
air distribution. The additional feature of automatic air Built In High Head Drain Pump & Water Flow Switch
swing helps to distribute the conditioned air evenly to The unit comes with a 700 mm built-in high head drain
every corners of the room. pump. A safety float is incorporated in the drain pump to
monitor its water level.

700mm

Branch Duct Connection


Improves air flow distribution when there is an
obstruction. It allows for air conditioning of two rooms
simultaneously.
Fresh Air Intake
• Knock out hole is available at the unit. Branch duct chamber
Discharge duct
• Installation and accessories such as booster fan is
field supplied and installed.

Wall
• Fresh air intake is within 20% of the total air flow.
Duct flange (With insulation material)
Room 1 Room 2

Intake duct (Field supplied and installed)

4
Ceiling Convertible, Ceiling Exposed (50Hz)

RX35DGXV1
FLQ35/50/60/71EXV1
RZQ71CGXV1
Wireless controller
BRC52A

FLQ100/125EXV1 RXN50CGXV1

Wired controller
BRC51A
(optional)

RZQ100/125/140FGXV1
FHQ140CXV1 RXN60CGXV1 RZQ100/125/140FGXY1

• Compact design • Room temperature sensing


• Far air throw • Sleep function in cool and heat modes
• Auto air swing • Auto random restart with last-state-memory
• Easy serviceability and maintenance • Self-diagnosis features
• Versatile installation - ceiling or floor installation • NIM-abled
(FLQ100/125E models only)
• Ionizer (FL series only)

5
Ceiling Convertible, Ceiling Exposed (50Hz)

Installation Flexibility for All Interior Décor Service and Maintenance at Ease
Uniquely designed with the option to install either below Easy access to filter by just pulling down the intake
the ceiling or mounted at a low wall position to suit any grille. During servicing or repairing, only the bottom
interior design requirements. panel is required to be removed in order to access to:
● fan motor
● blower
● wiring connection
● control box
● piping connection

*Wall bracket is supplied as an optional item


*FLQ100/125E models only

Flat Surface, Easy Clean


It is easy to wipe dirt off the flat panel surface of the unit.

Automatic Air Swing


The motorized louver enables the air flow to be evenly
distributed. Meanwhile, negative ion will be released to
provide quality air.

Options
High Head Drain Pump:
The unit is designed to work with high pressure head
drain pump, which offers flexibility for installation on
condensate drain pipe. A safety float is incorporated in
the drain pump as a safety protection.
Compact Design
Fresh Air Intake: Unit height as low as 212mm for installation at low
Allows intake of 20% fresh air to improve room ceiling space.
ventilation.
1090mm
630mm

700mm 212mm

Far Air Throw


Maximum air throw distance up to 16.5m.

6
Ceiling Concealed (50Hz)

RX25/35DGXV1
FDMQ25C2XV1
FDMQ35/50/60/71/100/125/140CXV1
RZQ71CGXV1

RXN50CGXV1

Wired controller
BRC51A
• Excellent air distribution
• Compact design
• High capacity range
• High external static pressure (ESP) range
• Double drainage protection RZQ100/125/140FGXV1
• Easy serviceability RXN60CGXV1 RZQ100/125/140FGXY1
• 4 available fan speed (class 71 and above)
• Auto random restart with last-state-memory
• Self-diagnosis features
• Wired controller
• NIM-abled

Flexibility in System Design Excellent Air Distribution


The unit comes with 4-speed motor as standard (class The conditioned air can be distributed evenly to every
71 and above), thus providing wide choices of external corner of the room through ducting. This helps to create
static range for designing the duct system. a pleasant environment and maintaining comfort.
Furthermore, multiple areas can be conditioned
simultaneously by using just one indoor unit.

Serviceability Friendly
The unit’s design enables access to control box and
filters from the side panel for easy serviceability.

Double Drain Pan Protection


The primary drain pan is designed with high thermal
insulation material and moulded in gradient for better
condensate water drainage.
The extra secondary drain pan built into the standard
unit offers extra protection against possible water
leaking problems.

filter cover

Compact Design
Unit height as low as 261mm for installation at limited primary drain
ceiling space area. pan polys-
terene (PS)
with High
905 mm Impact Polys-
terene (HIPS)
secondary drain pan cover
with insulation
261 mm

411 mm

7
Standard features

Sleep Mode Self Diagnosis Features


Pressing the Sleep button activates the Sleep Mode. This feature helps to detect any faults or malfunctioning
This function prevents excessive cooling/heating for a in the system and provide user a warning by blinking of
pleasant sleep. the LED lights.
Cooling
NIM-Able
+ Able to communicate with the versatile NIM networking
+ control module and offers the opportunity of one
+ centralized control for a system of multiple indoor units
in a building.
Set temp. before
Sleep mode Auto Restart with Last-State-Memory
begins to operate 30 30 60 In the event of a sudden power failure during operation,
mins mins mins unit restarts automatically in 64 different recovery
Time timing patterns (within 180 seconds to 244 seconds)
and the unit will operate based on the previous setting
Sleep mode turns on
(operating mode, temperature setting and fan speed).
Cooling operation:
1) After 30 minutes, room temperature is raised by 0.5˚C.
2) After 60 minutes, room temperature is raised by 0.5˚C. Power failure Power returns
3) After 120 minutes, room temperature is raised by 1˚C.
Operation Stop Restart

Heating
(heatpump models)
Set temp. before - E PROM
2

Sleep mode
begins to operate
-
- Settings stored before power failure

Anticorrosion Hydrophilic Gold Fin


The outdoor unit’s heat exchanger fins are constructed
30 30 60
mins mins mins from anticorrosion hydrophilic gold fin. The anticorrosion
fin increases the life span of the heat exchanger,
Time
especially when operating under corrosive and harsh
Sleep mode turns on
environment.
Heating operation:
1) After 30 minutes, room temperature is reduced by 1˚C.
2) After 60 minutes, room temperature is reduced by 1˚C.
3) After 120 minutes, room temperature is reduced by 1˚C.

8
Specifications - Ceiling Cassette 3x3, 2x2 (50Hz)
*

BLINK GOLD
*FCQ series

Specification for ceiling cassette 3x3


Indoor model name FCQ50EXV1 FCQ60EXV1 FCQ71EXV1 FCQ100EXV1 FCQ125EXV1 FCQ100EXV1 FCQ125EXV1
Outdoor model name RXN50CGXV1 RXN60CGXV1 RZQ71CGXV1 RZQ100FGXV1 RZQ125FGXV1 RZQ100FGXY1 RZQ125FGXY1
Nominal cooling capacity Btu/hr 18400 21500 24200 35900 44400 35800 42600
W 5410 6320 7100 10520 13010 10500 12500
Nominal heating capacity Btu/hr 18800 22200 28300 40600 48100 38200 47700
W 5530 6510 8300 11900 14100 11200 14000
Nominal EER W/W 3.41 3.25 3.21 3.84 3.34 3.42 3.22
Nominal COP W/W 3.70 3.99 3.85 3.93 3.88 3.61 3.63
Power supply V/Ph/Hz 220-240/1/50
Airflow cfm 600/530/430/400 680/600/530/430 860/725/620/530 1030/860/740/620 1200/1030/930/780 1030/860/740/620 1200/1030/930/780
Sound pressure level dBA 34/31/28/27 37/34/31/30 41/38/35/32 44/41/38/35 47/44/43/39 44/41/38/35 47/44/43/39
Indoor

Dimensions [with panel] 265x820x820 300x820x820


(HxWxD) mm [340x990x990] [375x990x990]
Net weight [with panel] kg 26 [30] 28 [32] 32 [36]
Power supply V/Ph/Hz 220-240/1/50 (power from indoor) 220-240/1/50 (power from outdoor) 380-415/3/50 (power from outdoor)
Sound pressure level dBA 51 50 51 50 51
Dimensions (HxWxD) mm 651x855x328 753x855x328 753x940x392 1374x900x320
Net weight kg 37 44 51 100
Outdoor

Pipe connection - Liquid mm 6.35 9.52


Pipe connection - Gas mm 12.70 15.88
Max. piping length m 30 50 75
Max. piping elevation m 10 30

Specification for ceiling cassette 2x2


Indoor model name FFQ25CXV1 FFQ35CXV1 FFQ50CXV1
Outdoor model name RX25DGXV1 RX35DGXV1 RXN50CGXV1
Nominal cooling capacity Btu/hr 9700 12400 18100
W 2870 3630 5310
Nominal heating capacity Btu/hr 10800 13200 19000
W 3190 3880 5580
Nominal EER W/W 3.68 3.61 3.21
Nominal COP W/W 4.03 3.79 3.28
Power supply V/Ph/Hz 220-240/1/50
Airflow cfm 400/390/370 410/390/360 450/430/410
Sound pressure level dBA 44/41/38 45/42/38 47/46/44
Indoor

Dimensions [with panel] 250x570x570


(HxWxD) mm [295x640x640]
Net weight [with panel] kg 16 [18]
Power supply V/Ph/Hz 220-240/1/50 (power from indoor)
Sound pressure level dBA 47 49 51
Dimensions (HxWxD) mm 550x765x285 651x855x328
Net weight kg 31 33 37
Outdoor

Pipe connection - Liquid mm 6.35


Pipe connection - Gas mm 9.52 12.70
Max. piping length m 15 30
Max. piping elevation m 10
1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; Outdoor temp. 35°CDB; Piping length 7.5m.
2. Rated heating capacities are based on the following conditions: Indoor temp. 20°CDB; Outdoor temp. 7°CDB; Piping length 7.5m.

9
Specifications - Ceiling Convertible, Ceiling Exposed (50Hz)

*
BLINK GOLD ION
*FLQ series

Specification for ceiling convertible, ceiling exposed


Indoor model name FLQ35EXV1 FLQ50EXV1 FLQ60EXV1 FLQ71EXV1 FLQ100EXV1
Outdoor model name RX35DGXV1 RXN50CGXV1 RXN60CGXV1 RZQ71CGXV1 RZQ100FGXV1
Nominal cooling capacity Btu/hr 12200 18300 20600 23200 34100
W 3590 5370 6040 6800 10000
Nominal heating capacity Btu/hr 13100 19000 21000 26300 38900
W 3860 5580 6180 7708 11400
Nominal EER W/W 3.87 3.19 3.01 2.81 3.05
Nominal COP W/W 3.97 3.45 3.30 3.01 3.90
Power supply V/Ph/Hz 220-240/1/50
Airflow cfm 508/386/350 520/460/406 580/530/490 640/560/460 1100/983/877
Indoor

Sound pressure level dBA 46/38/35 50/43/41 53/51/49 56/51/44 52/47/46


Dimensions (HxWxD) mm 218x1080x630 260x1538x634
Net weight kg 25 27 45
220-240/1/50
Power supply V/Ph/Hz 220-240/1/50 (power from indoor) (power from outdoor)
Sound pressure level dBA 49 51 50
Dimensions (HxWxD) mm 550x765x285 651x855x328 753x855x328 753x940x392 1374x900x320
Outdoor

Net weight kg 33 37 44 51 100


Pipe connection - Liquid mm 6.35 9.52
Pipe connection - Gas mm 12.70 15.88
Max. piping length m 15 30 50 75
Max. piping elevation m 10 10 30

Indoor model name FLQ100EXV1 FLQ125EXV1 FLQ125EXV1 FHQ140CXV1 FHQ140CXV1


Outdoor model name RZQ100FGXY1 RZQ125FGXV1 RZQ125FGXY1 RZQ140FGXV1 RZQ140FGXY1
Nominal cooling capacity Btu/hr 34100 43000 42600 47800 44300
W 10000 12600 12500 14010 13000
Nominal heating capacity Btu/hr 38200 52900 47700 54300 52800
W 11200 15500 14000 15910 15500
Nominal EER W/W 3.23 3.50 3.01 2.87 2.66
Nominal COP W/W 3.61 3.55 3.61 3.51 3.61
Power supply V/Ph/Hz 220-240/1/50
Airflow cfm 1100/983/877 1215/1082/959 1215/1082/959 1550/1320/1000 1550/1320/1000
Indoor

Sound pressure level dBA 52/47/46 52/50/49 52/50/49 56/53/46 56/53/46


Dimensions (HxWxD) mm 260x1538x634 260x1786x634 285x1903x680
Net weight kg 45 65 70
380-415/3/50 220-240/1/50 380-415/3/50 220-240/1/50 380-415/3/50
Power supply V/Ph/Hz (power from outdoor) (power from outdoor) (power from outdoor) (power from outdoor) (power from outdoor)
Sound pressure level dBA 50 51
Dimensions (HxWxD) mm 1374x900x320
Outdoor

Net weight kg 100


Pipe connection - Liquid mm 9.52
Pipe connection - Gas mm 15.88
Max. piping length m 75
Max. piping elevation m 30
1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; Outdoor temp. 35°CDB; Piping length 7.5m.
2. Rated heating capacities are based on the following conditions: Indoor temp. 20°CDB; Outdoor temp. 7°CDB; Piping length 7.5m.

10
Specifications - Ceiling Concealed (50Hz)

BLINK GOLD

Specification for ceiling concealed - Cooling and heating (R410A)


Indoor model name FDMQ25C2XV1 FDMQ35CXV1 FDMQ50CXV1 FDMQ60CXV1 FDMQ71CXV1 FDMQ100CXV1
Outdoor model name RX25DGXV1 RX35DGXV1 RXN50CGXV1 RXN60CGXV1 RZQ71CGXV1 RZQ100FGXV1
Nominal cooling capacity Btu/hr 8700 12500 17700 20600 24200 34800
W 2570 3670 5200 6050 7100 10200
Nominal heating capacity Btu/hr 9500 12600 19600 21800 27600 38200
W 2770 3700 5770 6400 8100 11200
Nominal EER W/W 3.22 3.36 3.28 3.20 3.21 3.40
Nominal COP W/W 3.43 3.46 3.44 3.65 3.70 4.15
Power supply V/Ph/Hz 220-240/1/50
Airflow cfm 250/235/210 410/370/250 570/540/450 690/640/520 850/700/590/480 1280/1160/1050/920
External static pressure Pa 29/20/10 78/53/38/25 118/96/78/61
Indoor

Sound pressure level dBA 35/32/26 37/34/29 38/36/34 40/39/36 44/41/38/34 55/51/48/45
Dimensions (HxWxD) mm 261x905x411 261x1065x411 261x1200x411 285x1007x600 305x1302x638
Net weight kg 18 22 24 26 40 49
220-240/1/50
Power supply V/Ph/Hz 220-240/1/50 (power from indoor) (power from
outdoor)
Sound pressure level dBA 48 49 51 50
Dimensions (HxWxD) mm 550x765x285 651x855x328 753x855x328 753x940x392 1374x900x320
Outdoor

Net weight kg 31 33 37 44 51 100


Pipe connection - Liquid mm 6.35 9.52
Pipe connection - Gas mm 9.52 12.70 15.88
Max. piping length m 15 30 50 75
Max. piping elevation m 10 30

Indoor model name FDMQ100CXV1 FDMQ125CXV1 FDMQ125CXV1 FDMQ140CXV1 FDMQ140CXV1


Outdoor model name RZQ100FGXY1 RZQ125FGXV1 RZQ125FGXY1 RZQ140FGXV1 RZQ140FGXY1
Nominal cooling capacity Btu/hr 34800 45400 43300 47800 47700
W 10200 13310 12700 14010 14000
Nominal heating capacity Btu/hr 38200 53600 47700 56600 56200
W 11200 15710 14000 16590 16500
Nominal EER W/W 3.29 3.65 3.21 3.31 3.05
Nominal COP W/W 3.70 3.87 3.62 3.96 3.62
Power supply V/Ph/Hz 220-240/1/50
Airflow cfm 1280/1160/1050/920 1430/1320/1230/1130 1720/1550/1340/1170
External static pressure Pa 118/96/78/61 147/126/109/92 147/120/90/69
Indoor

Sound pressure level dBA 55/51/48/45 53/52/50/47 55/53/50/47


Dimensions (HxWxD) mm 305x1302x638 378x1299x541 378x1499x541
Net weight kg 49 50 56
380-415/3/50 220-240/1/50 380-415/3/50 220-240/1/50 380-415/3/50
Power supply V/Ph/Hz (power from outdoor) (power from outdoor) (power from outdoor) (power from outdoor) (power from outdoor)
Sound pressure level dBA 50 51
Dimensions (HxWxD) mm 1374x900x320
Outdoor

Net weight kg 100


Pipe connection - Liquid mm 9.52
Pipe connection - Gas mm 15.88
Max. piping length m 75
Max. piping elevation m 30
1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; Outdoor temp. 35°CDB; Piping length 7.5m.
2. Rated heating capacities are based on the following conditions: Indoor temp. 20°CDB; Outdoor temp. 7°CDB; Piping length 7.5m.

11
Standard Features

Comfortable Airflow Timers

Vertical Auto-Swing (up and down) Heat mode:


This function automatically moves the flaps up and down After 30 minutes, room temperature is reduced by 1°C.
to distribute air across a room. After 60 minutes, room temperature is reduced by 1°C.
After 120 minutes, room temperature is reduced by
Horizontal Auto-Swing (left and right) 1°C.
Horizontal Auto-Swing automatically moves the louvers
to the left and right to cover a room with cool air.
Worry Free
Comfort Control Auto Random Restart with
Last-State-Memory
Indoor Unit Quiet Operation In the event of a sudden power failure during operation,
Indoor unit operating sound levels are decreased unit restarts automatically in 64 different recovery
by 3dB(A) from the Low setting fan speed using the timing patterns (within 180 seconds to 244 seconds)
wireless remote controller. and the unit will operate based on the previous setting
(operating mode, temperature setting and fan speed).
Automatic Operation
This function automatically selects cooling or heating Self-Diagnosis
operation mode based on the room temperature at BLINK Malfunctioning of air conditioner unit by blinking of LED
start-up. lights for fast and easy maintenance.
Programme Dry Function
Anticorrosion Hydrophilic Gold Fin
This function automatically reduces the level of GOLD The outdoor unit’s heat exchanger fins are constructed
humidity.
from anticorrosion hydrophilic gold fin. The anticorrosion
fin increases the life span of the heat exchanger,
Timers especially when operating under corrosive and harsh
environment.
24-Hour On/Off Timer
This timer can be preset to start and stop at any time
Cleanliness
within a 24-hour period. The air conditioner is started/
stopped simply by pressing the On/Off timer button on
the wireless remote controller. Washable Saranet Filter
Removal of airborne dust particles through saranet filter
Sleep Mode ensures cleaner air supply.
Pressing the Sleep button activates the Sleep Mode.
Cool mode: Ionizer
After 30 minutes, room temperature is raised by 0.5°C. ION Ionizer that releases negative ions, sterilizing the air by
After 60 minutes, room temperature is raised by 0.5°C. removing airborne particles.
After 120 minutes, room temperature is raised by 1°C.

Controllers

BRC51A61 Heatpump with auto mode BRC52A61 Heatpump with auto mode

Features:
• “Glow in the dark” on/off button
• Cool/Heat/Fan/Dry/Auto mode
• Auto/High/Med/Low fan speed
• Sleep function
• Air swing function
• Real time clock
• On/off timer setting in real time

Features:
• Cool/Heat/Fan/Dry/Auto mode • Keylock function
• Auto/High/Med/Low fan speed • Batteries backup and retain setting
• Temperature operate in ºC and ºF during power failure
• Sleep function • Last state memory (memory backup
• Air swing function setting from main board)
• Real time clock and day display • Delay timer (1 or 2 hours)
• 7-days programmable timer • Interaction with wireless handset-
• Error indicator BRC52A61

12
Intelligent Control Series

Network Interface Module (NIM) is a networking system which enables communication among Daikin air conditioners.
With the Network interface Module (NIM), all your air conditioning systems can be controlled with just a single controller
providing various benefits stated below.

Network Controls NIM

Benefits
• More convenience. No more individually controlling air conditioning units.
• Quicker and easier zone control from the master control unit.
• Better control of air conditioning systems operating conditions.

NIM utilizes master-slave type system whereby the master node will issue commands to
each of the slave nodes.
Every master unit will have a group address so that every slave can only response to
their respective master. Each slave unit must have a unique address so that it can be
addressed independently of other nodes.

The master unit will be operating in conjunction with a control panel. Any settings done
via the control panel connected to the master will overwrite the settings of its slave units.

Slave unit can be operated with or without control panel. If a slave unit is operating with
a control panel, its settings can be changed without following its master. NIM

Basic Features
• DIP switch setting for Group & Unit address. • Maximum point to point communication bus up to
• Master or slave system configuration. 1000m.
• Automatic detection of control panel existence. • A single master unit can control up to 15 slave units
• Error type and unit ID indication through display in each group.
control panel. • Each slave unit will sense their individual local
temperature.
• Unit address range from 0 to 15 (0000-1111).
The NIM system consists of:
• Main board controller
• Display control panel
• NIM controller
• Communications bus

Connection

(up to total
of 16 FCUs)

Master Slave Slave(s)

Main board controllers and display control panel


NIM must be used in conjunction with: Supported configuration:
• Fan coil units
• BRC51A or BRC52A Master Slave
BRC51A • •
BRC52A - •
13
Intelligent Control Series

Communication Bus
A 2-way twisted pair cable is used as the communication Recommended
bus. Recommended cable for communication bus is a maximum cable
pair of screened and shielded twisted single core wire length (m)
with core diameter of 0.5mm to 1.0mm.
First NIM to the furthest connected 1000
NIM
Connection
The communication bus must be connected serially to NIM to main board 10
the adjacent NIM. (Daisy chain connection). The same NIM to wired controller 10
polarity has to be connected between the NIMs (A to A,
B to B).

G-way

Function
• Gateway between fan coil unit and basic Building Management
System (BMS).
Note:
• Remote (On/Off) control of air conditioner via BMS.
• Unit error indication via BMS and BRC51A controller.
• Unit operation status monitoring via BMS.
• Maximum point-to-point communication bus between air conditioner
and BMS of up to 1000m. G-way
• DIP switch setting for control or monitoring function.

Types of operation DSW2 Setting


Control & Monitor
0000
(Ext. Switch Closed = ON A/C)
Control & Monitor
0010
(Ext. Switch Open = ON A/C)
Monitoring only 0001

to wired control panel


CN2
Dry Contact Dry Contact
Input Switch

NO Dry Contact Unit On/Off


to mainboard CN1 relay 1 Indicator
COM Output 1
relay 2
NO Dry Contact Unit Error
COM Output 2 Indicator
DIP switch
Terminal
blocks

1000 m
G-way controller BMS

14
Warning ● Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm
with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and
is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify
the application of any local legislation.

● Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can
result in water or refrigerant leakage, electrical shock, fire or explosion.

● Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those
parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can
result in water or refrigerant leakage, electrical shock, fire or explosion.

● Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and
warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Caution Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need
to install the outdoor unit close to the sea shore, contact your local distributor.

Dealer
Lot 60334, Persiaran Bukit Rahman Putra 3,
Taman Perindustrian Bukit Rahman Putra,
47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia.
http://www.daikinmalaysia.com/

Head office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan.