You are on page 1of 523

Column Design: Design Calculations Page 1 of 523

COLUMN DESIGN CALCULATIONS


Project Name : SSCT INTERNATIONAL HOUSE
Client Name : SSCT STUDENTS
Engineer Name : ENGR.GONZALES
Design File : C:\Users\USER\Desktop\UNTA MAU NA\RCDC
De\COLUMN\COLUMN.rcdx
Analysis File : C:\Users\john roy\Desktop\KINGLEMUEL\UNTA MAU
NA\SSCT International House.std
Analysis Last Modified : 09/05/2020 12:30:07 AM

Definitions Of Terms:
All forces in units kN and m
All reinforcement details like area, spacing in mm
Neutral axis angle for resultant design moment is with respect to local major axis.
Ratio to account for reduction of stiffness of
1 βdns =
columns due to sustained axial loads
Moment magnification factor for frames not braced
2 δns =
against sidesway
First-order relative deflection between the top and
3 Δo =
bottom of the story due to Vu in mm
Total factored vertical load in the story
4 ∑Pu = corresponding to the lateral loading case for which
∑Pu is greatest, kN (Clause 10.10.5)
5 δu = Design displacement in mm
Modification factor reflecting the reduced
6 λ =
mechanical properties of lightweight concrete
7 Φ = Strength reduction factor
Coefficient defining the relative contribution of
8 ac =
concrete strength to nominal wall shear strength
Cross-sectional area of a structural member
9 Ach = measured to the outside edges of transverse
reinforcement in sqmm
Gross area of concrete section bounded by web
10 Acv = thickness and length of section in the direction of
shear force considered in sqmm
Effective cross-sectional area within a joint in a
11 Aj = plane parallel to plane of reinforcement generating
shear in the joint in sqmm
Area of non-prestressed longitudinal tension
12 As =
reinforcement in sqmm
Minimum area of shear reinforcement within
13 Avmin =
spacing 's' in sqmm
14 B = Width of column/ wall in mm
15 B' = width of beam along B / column width in mm
Cross-sectional dimension of member core
16 bc = measured to the outside edges of the transverse
reinforcement composing area Ash in mm
Distance from extreme compression fiber to neutral
17 c =
axis in mm
18 Cc = Clear cover of reinforcement in mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 2 of 523

Factor relating actual moment diagram to an


19 Cm =
equivalent uniform moment diagram
20 D = Depth / diameter of column in mm
21 D' =
Distance from extreme compression fiber to
22 d = centroid of longitudinal tension reinforcement in
mm
Distance from extreme compression fiber to
23 d' = centroid of longitudinal compression
reinforcement,mm
24 Ec = Modulus of elasticity of concrete in N/sqmm
Flexural stiffness of compression member in N-
25 EI =
sqmm
26 f'c = Specified strength of concrete in N/sqmm
Specified yield strength of reinforcement in
27 fy =
N/sqmm
Specified yield strength fy of transverse
28 fyt =
reinforcement in N/sqmm
Height of entire wall from base to top, or clear
29 hw = height of wall segment or wall pier considered in
mm
30 k = Effective length factor for compression member
31 lc = Length of compression member in a frame in mm
Moment of inertia of gross concrete section about
32 lg =
centroidal axis neglecting reinforcement in mm4
33 lw = Length of entire wall in mm
Un-supported length for compression member
34 lux =
along D in mm
Un-supported length for compression member
35 luy =
along B in mm
Moment capacity of section for NA angle at design
36 MCap =
Pu in kNm
Resultant design moment at angle to local major
37 MRes =
axis in kNm
Factored moment amplified for the effects of
38 Mc = member curvature used for design of compression
member in kNm
Factored moment modified to account for effect of
39 mm =
axial compression in kNm
Factored moment at section along D in kNm (From
40 Mux =
Analysis)
Factored moment at section along B in kNm (From
41 Muy =
Analysis)
Smaller factored end moment on a compression
42 M1 =
member in kNm
Factored end moment on a compression member at
43 M1ns = the end at which M1 acts, due to loads that cause no
appreciable sidesway in kNm
Factored end moment on compression member at
44 M1s = the end at which M1 acts, due to loads that cause
appreciable sidesway in kNm
Smaller factored end moment on a compression

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 3 of 523

45 M1sldr = member due to slenderness effect in kNm


Larger factored end moment on compression
46 M2 =
member in kNm
47 M2min = Minimum value of M2
Factored end moment on compression member at
48 M2ns = the end at which M2 acts, due to loads that cause no
appreciable sidesway in kNm
Factored end moment on compression member at
49 M2s = the end at which M2 acts, due to loads that cause
appreciable sidesway in kNm
Largest factored end moment on a compression
50 M2sldr =
member due to slenderness effect in kNm
51 Mnb = Flexure Capacity for Beam
52 Mnc = Flexure Capacity for Column
53 Mnty = Flexure strength at top along column depth, kNm
Flexure strength at bottom along column depth,
54 Mnby =
kNm
55 Mntx = Flexure strength at top along column width, kNm
Flexure strength at bottom along column width,
56 Mnbx =
kNm
Factored axial force normal to cross section
57 Nu =
occurring simultaneously with Vu in kN
58 Pc = Critical buckling load in kN
Ratio of area of distributed transverse
59 pt = reinforcement to gross concrete area perpendicular
to that reinforcement
60 Pω = Ratio of As to B x d
61 Q = Stability index for storey
Radius of gyration of cross section of a compression
62 r =
member in mm
63 Vc = Nominal shear strength provided by concrete in kN
64 Vj = Shear Force acting at the joint in kN
65 Vn = Nominal shear strength in kN
66 Vn' = Nominal shear strength in kN
Factored horizontal shear in a storey of section in
67 Vus =
kN
Factored shear at section along D in kN (From
68 Vux =
Analysis)
Shear induced due to column flexural capacity
69 Vux1 =
along width, kN
Shear due to enhanced earthquake factor along
70 Vux2 =
width, kN
Factored shear at section along B in kN (From
71 Vuy =
Analysis)
Shear induced due to column flexural capacity
72 Vuy1 =
along depth, kN
Shear due to enhanced earthquake factor along
73 Vuy2 =
depth, kN

Code References:

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 4 of 523

ACI 318M-2011
Sr.No Element Clause / table
Minimum area of longitudinal
1 : 21.6.3
reinforcement for column
Maximum area of longitudinal
2 : 21.6.3
reinforcement for column
Minimum longitudinal and transverse
3 : 21.9.2.1
reinforcement for wall
4 Minimum diameter of transverse ties : 7.10.5
5 Minimum spacing of transverse ties : 7.10.5
Maximum spacing of longitudinal and
6 : 21.9.2.1
transverse reinforcement for wall
7 Applicability of boundary element : 21.9.6
Area and spacing of special confining
8 : 21.6.4
reinforcement
9 Slenderness Moments : 10.10
Shear Strength provided by concrete for
10 : 11.2
column
11 Design of shear for non-ductile wall : 11.9
12 Design of shear for ductile wall : 21.9.4
13 Minimum Flexural Strength of Columns : 21.6.2.2
14 Shear Check at Column Joint : 21.7.4.1
15 Shear Strength of Column : 21.3.3 & 21.5.4

Sway Calculation (Stability Index)


For Global-X Direction
Level Load Story Gravity Relative Story Shear Stability Sway
Name Height Load P (kN) Displacements (kN) Index Condition
(m) (mm)
B x C / (A x
A B C D
D)
0m to LOAD 1:
1.8 38384.306 1.31 3094.143 0.009 Non Sway
1.8m EX
1.8m to LOAD 1:
3.5 35246.103 6.763 2990.395 0.023 Non Sway
5.3m EX
5.3m to LOAD 1:
3.5 22833.731 5.942 2289.857 0.017 Non Sway
8.8m EX
8.8m to LOAD 1:
3.5 10208.549 3.185 1094.076 0.008 Non Sway
12.3m EX

For Global-Y Direction


Level Load Story Gravity Relative Story Shear Stability Sway
Name Height Load P (kN) Displacements (kN) Index Condition
(m) (mm)
B x C / (A x
A B C D
D)
0m to LOAD 2:
1.8 38384.306 1.305 2990.257 0.009 Non Sway
1.8m EZ
1.8m to LOAD 2:

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 5 of 523

5.3m EZ 3.5 35246.103 6.78 2889.992 0.024 Non Sway


5.3m to LOAD 2:
3.5 22833.731 6.133 2212.975 0.018 Non Sway
8.8m EZ
8.8m to LOAD 2:
3.5 10208.549 3.388 1057.342 0.009 Non Sway
12.3m EZ

General Data
Column No. : C1
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 79
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 204.04 kN
Muxt = 9.14 kNm
Muyt = 39.25 kNm
Vuxt = -85.68 kN
Vuyt = -16.49 kN
Pub = 211.25 kN
Muxb = -20.53 kNm
Muyb = 193.43 kNm
Vuxb = -85.68 kN
Vuyb = -16.49 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 6 of 523

N-M mm mm N-M N-M


Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x
Top 265.195 No Beam 88.95 - 4.517
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam 74.125 - 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 9.14 kNm
M2 = -20.53 kNm
34 - 12 x (M1/M2) = 39.34
7.53 < 39.34, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 7 of 523

M1 = 39.25 kNm
M2 = 193.43 kNm
34 - 12 x (M1/M2) = 31.56
7.53 < 31.56, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 9.14 - 9.14
Major Axis Mux (bottom) -20.53 - -20.53
Minor Axis Muy (top) 39.25 - 39.25
Minor Axis Muy (bottom) 193.43 - 193.43

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 211.25 kN
Mux = -20.53 kNm
Muy = 193.43 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 83.94 deg
MRes = 194.51 kNm
MCap = 262.26 kNm
Capacity Ratio = MRes/ MCap
= 0.742 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 632.89 kN
Muy = 155.9 kNm
Vuy = -87.2869 kN
λ = 1
φ = 0.65
deff = 450 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 8 of 523

ρw = 0.006
mm = 33.28 kNm
Vcy Permissible = 170.5 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 1053.21 kN
Mux = 207.48 kNm
Vux = 108.9006 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 3.42 kNm
Vcx Permissible = 170.15 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C1
Level : 1.8m To 5.3m

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 9 of 523

Design Code = ACI 318M - 2011


Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 125
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 1012.24 kN
Muxt = -35.18 kNm
Muyt = 235.74 kNm
Vuxt = 137.38 kN
Vuyt = 13.03 kN
Pub = 1041.53 kN
Muxb = 10.42 kNm
Muyb = -244.97 kNm
Vuxb = 137.38 kN
Vuyb = 13.03 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x
Bottom 136.386 No Beam 88.95 - 4.517
550
5000 x 350 x 2250 x 350 x
Top 136.386 88.95 197.666 0.952
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.86
Axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 10 of 523

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 5.409
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.86
r = 144.34 mm
Kluy /r = 17.58
M1 = 10.42 kNm
M2 = -35.18 kNm
34 - 12 x (M1/M2) = 37.55
17.58 < 37.55, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 235.74 kNm
M2 = -244.97 kNm
34 - 12 x (M1/M2) = 45.55
20.44 < 45.55, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 11 of 523

A B C
Major Axis Mux (top) -35.18 - -35.18
Major Axis Mux (bottom) 10.42 - 10.42
Minor Axis Muy (top) 235.74 - 235.74
Minor Axis Muy (bottom) -244.97 - -244.97

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1012.24 kN
Mux = -35.18 kNm
Muy = 235.74 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 81.51 deg
MRes = 238.35 kNm
MCap = 322.5 kNm
Capacity Ratio = MRes/ MCap
= 0.739 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 499.64 kN
Muy = 116.33 kNm
Vuy = -78.8663 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 19.53 kNm
Vcy Permissible = 171.66 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 12 of 523

[20] : 0.68 (LOAD 3: DL) +1.25


Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 185.94 kN
Mux = 132.15 kNm
Vux = -89.9565 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 96.12 kNm
Vcx Permissible = 171.69 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C1
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 13 of 523

Clear Floor Height @ luy = 2950 mm


No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 248
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 574.73 kN
Muxt = -54.34 kNm
Muyt = 249.52 kNm
Vuxt = 129.46 kN
Vuyt = 29.09 kN
Pub = 604.02 kN
Muxb = 47.43 kNm
Muyb = -203.47 kNm
Vuxb = 129.46 kN
Vuyb = 29.09 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 2250 x 350 x
Bottom 136.386 88.95 197.666 0.952
550 550
5000 x 350 x 2250 x 350 x
Top 136.386 88.95 197.666 0.952
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.77
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 14 of 523

Top 136.386 550 No Beam 74.125 - 3.674


Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.77
r = 144.34 mm
Kluy /r = 15.74
M1 = 47.43 kNm
M2 = -54.34 kNm
34 - 12 x (M1/M2) = 44.48
15.74 < 44.48, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -203.47 kNm
M2 = 249.52 kNm
34 - 12 x (M1/M2) = 43.79
20.44 < 43.79, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -54.34 - -54.34
Major Axis Mux (bottom) 47.43 - 47.43
Minor Axis Muy (top) 249.52 - 249.52
Minor Axis Muy (bottom) -203.47 - -203.47

Where
A = Moments from analysis
B = Moment due to slenderness effect

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 15 of 523

C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 574.73 kN
Mux = -54.34 kNm
Muy = 249.52 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 77.71 deg
MRes = 255.37 kNm
MCap = 308.06 kNm
Capacity Ratio = MRes/ MCap
= 0.829 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 127.16 kN
Muy = 85.01 kNm
Vuy = 60.005 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 60.37 kNm
Vcy Permissible = 171.93 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 283.64 kN
Mux = 140.45 kNm
Vux = 94.707 kN
λ = 1
φ = 0.65
deff = 450 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 16 of 523

ρw = 0.006
mm = 85.49 kNm
Vcx Permissible = 171.62 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C1
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 371
Critical Analysis Load Combination : 18

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 17 of 523

[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25


Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 154.9 kN
Muxt = 31.46 kNm
Muyt = 165.98 kNm
Vuxt = 80.35 kN
Vuyt = -5.83 kN
Pub = 184.18 kN
Muxb = 11.05 kNm
Muyb = -115.16 kNm
Vuxb = 80.35 kN
Vuyb = -5.83 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 2250 x 350 x
Bottom 136.386 88.95 197.666 0.952
550 550
5000 x 350 x
Top 136.386 No Beam 88.95 - 1.534
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.86
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 18 of 523

       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.86
r = 144.34 mm
Kluy /r = 17.58
M1 = 11.05 kNm
M2 = 31.46 kNm
34 - 12 x (M1/M2) = 29.78
17.58 < 29.78, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -115.16 kNm
M2 = 165.98 kNm
34 - 12 x (M1/M2) = 42.33
20.44 < 42.33, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 31.46 - 31.46
Major Axis Mux (bottom) 11.05 - 11.05
Minor Axis Muy (top) 165.98 - 165.98
Minor Axis Muy (bottom) -115.16 - -115.16

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 154.9 kN
Mux = 31.46 kNm
Muy = 165.98 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 19 of 523

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 79.27 deg
MRes = 168.94 kNm
MCap = 252.41 kNm
Capacity Ratio = MRes/ MCap
= 0.669 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 210.19 kN
Muy = 9.28 kNm
Vuy = -12.5454 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 31.44 kNm
Vcy Permissible = 333.48 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 152.6 kN
Mux = 94.68 kNm
Vux = 68.2194 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 65.11 kNm
Vcx Permissible = 172.08 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 20 of 523

Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C2
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 81
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 272.21 kN
Muxt = 3.7 kNm
Muyt = 24.15 kNm
Vuxt = -91.07 kN
Vuyt = -12.18 kN
Pub = 279.42 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 21 of 523

Muxb = -18.21 kNm


Muyb = 188.04 kNm
Vuxb = -91.07 kN
Vuyb = -12.18 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam 74.125 - 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 22 of 523

Slenderness Check along D


K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 3.7 kNm
M2 = -18.21 kNm
34 - 12 x (M1/M2) = 36.43
7.53 < 36.43, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 24.15 kNm
M2 = 188.04 kNm
34 - 12 x (M1/M2) = 32.46
7.53 < 32.46, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 3.7 - 3.7
Major Axis Mux (bottom) -18.21 - -18.21
Minor Axis Muy (top) 24.15 - 24.15
Minor Axis Muy (bottom) 188.04 - 188.04

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 279.42 kN
Mux = -18.21 kNm
Muy = 188.04 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 84.47 deg
MRes = 188.92 kNm
MCap = 273.53 kNm
Capacity Ratio = MRes/ MCap

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 23 of 523

= 0.691 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 470.66 kN
Muy = 47.54 kNm
Vuy = 124.0022 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 43.65 kNm
Vcy Permissible = 371.78 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 793.31 kN
Mux = 188.52 kNm
Vux = -92.5346 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 34.82 kNm
Vcx Permissible = 169.81 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 24 of 523

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C2
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 127
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 1010.45 kN
Muxt = 199.95 kNm
Muyt = 86.85 kNm
Vuxt = 38.23 kN
Vuyt = -120.07 kN
Pub = 1039.74 kN
Muxb = -220.17 kNm
Muyb = -46.91 kNm
Vuxb = 38.23 kN
Vuyb = -120.07 kN

Effective Length Calculation

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 25 of 523

Calculation Along Major Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 5.409
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 199.95 kNm
M2 = -220.17 kNm
34 - 12 x (M1/M2) = 44.9

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 26 of 523

20.44 < 44.9, Column not slender along D


Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -46.91 kNm
M2 = 86.85 kNm
34 - 12 x (M1/M2) = 40.48
20.44 < 40.48, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 199.95 - 199.95
Major Axis Mux (bottom) -220.17 - -220.17
Minor Axis Muy (top) 86.85 - 86.85
Minor Axis Muy (bottom) -46.91 - -46.91

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1010.45 kN
Mux = 199.95 kNm
Muy = 86.85 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 23.48 deg
MRes = 218 kNm
MCap = 285.63 kNm
Capacity Ratio = MRes/ MCap
= 0.763 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 27 of 523

Nu = 824.77 kN
Muy = 190.75 kNm
Vuy = 114.7432 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 30.95 kNm
Vcy Permissible = 170.91 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 251.07 kN
Mux = 111.63 kNm
Vux = -81.1145 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 62.99 kNm
Vcx Permissible = 172.14 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 28 of 523

General Data
Column No. : C2
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 250
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 634.77 kN
Muxt = 190.06 kNm
Muyt = 100.57 kNm
Vuxt = 60.43 kN
Vuyt = -100.89 kN
Pub = 664.06 kN
Muxb = -162.97 kNm
Muyb = -110.89 kNm
Vuxb = 60.43 kN
Vuyb = -100.89 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
Top 136.386 5000 x 350 x 5000 x 350 x 88.95 88.95 1.534

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 29 of 523

550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -162.97 kNm
M2 = 190.06 kNm
34 - 12 x (M1/M2) = 44.29
20.44 < 44.29, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 100.57 kNm
M2 = -110.89 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 30 of 523

34 - 12 x (M1/M2) = 44.88
20.44 < 44.88, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 190.06 - 190.06
Major Axis Mux (bottom) -162.97 - -162.97
Minor Axis Muy (top) 100.57 - 100.57
Minor Axis Muy (bottom) -110.89 - -110.89

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 634.77 kN
Mux = 190.06 kNm
Muy = 100.57 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 27.89 deg
MRes = 215.03 kNm
MCap = 282.98 kNm
Capacity Ratio = MRes/ MCap
= 0.76 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 1: EX)
Nu = 664.65 kN
Muy = 133.72 kNm
Vuy = 83.4312 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 4.94 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 31 of 523

Vcy Permissible = 171.13 kN


Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 329.01 kN
Mux = 121.52 kNm
Vux = 82.8721 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 57.77 kNm
Vcx Permissible = 171.7 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C2
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 32 of 523

Grade Of Steel = Fy420 N/sqmm


Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 373
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 280.34 kN
Muxt = -6.13 kNm
Muyt = 206.24 kNm
Vuxt = 94.46 kN
Vuyt = 1.49 kN
Pub = 309.63 kN
Muxb = -0.91 kNm
Muyb = -124.28 kNm
Vuxb = 94.46 kN
Vuyb = 1.49 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 33 of 523

Stiffness Beam 1 Beam 2 Beam 1 Beam 2


(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = -0.91 kNm
M2 = -6.13 kNm
34 - 12 x (M1/M2) = 32.23
17.37 < 32.23, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -124.28 kNm
M2 = 206.24 kNm
34 - 12 x (M1/M2) = 41.23
20.44 < 41.23, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -6.13 - -6.13

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 34 of 523

Major Axis Mux (bottom) -0.91 - -0.91


Minor Axis Muy (top) 206.24 - 206.24
Minor Axis Muy (bottom) -124.28 - -124.28

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 280.34 kN
Mux = -6.13 kNm
Muy = 206.24 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.3 deg
MRes = 206.33 kNm
MCap = 275.26 kNm
Capacity Ratio = MRes/ MCap
= 0.75 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 396.89 kN
Muy = 6.84 kNm
Vuy = -2.5543 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 70.05 kNm
Vcy Permissible = 361.35 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 35 of 523

Nu = 243.32 kN
Mux = 97.92 kNm
Vux = 76.3129 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 50.78 kNm
Vcx Permissible = 172.66 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C3
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 36 of 523

No Of Columns In Group = 1

Load Data
Analysis Reference No. = 83
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 283.82 kN
Muxt = 4.1 kNm
Muyt = 22.4 kNm
Vuxt = -85.91 kN
Vuyt = -12.5 kN
Pub = 291.04 kN
Muxb = -18.39 kNm
Muyb = 177 kNm
Vuxb = -85.91 kN
Vuyb = -12.5 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam 74.125 - 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)

Effective Length Factor along Minor = 0.87

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 37 of 523

axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 4.1 kNm
M2 = -18.39 kNm
34 - 12 x (M1/M2) = 36.68
7.53 < 36.68, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 22.4 kNm
M2 = 177 kNm
34 - 12 x (M1/M2) = 32.48
7.53 < 32.48, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 4.1 - 4.1
Major Axis Mux (bottom) -18.39 - -18.39
Minor Axis Muy (top) 22.4 - 22.4
Minor Axis Muy (bottom) 177 - 177

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 38 of 523

Critical Case - Axial Load & BiAxial Bending


Pu = 291.04 kN
Mux = -18.39 kNm
Muy = 177 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 84.07 deg
MRes = 177.95 kNm
MCap = 275.44 kNm
Capacity Ratio = MRes/ MCap
= 0.646 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 455.7 kN
Muy = 43.64 kNm
Vuy = 120.9207 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 44.65 kNm
Vcy Permissible = 369.69 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 805.51 kN
Mux = 177.91 kNm
Vux = -87.6934 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 21.84 kNm
Vcx Permissible = 169.83 kN
Vux < Vcx Permissible

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 39 of 523

Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C3
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 129
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 1027.57 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 40 of 523

Muxt = 192.31 kNm


Muyt = 82.67 kNm
Vuxt = 35.27 kN
Vuyt = -116.78 kN
Pub = 1056.86 kN
Muxb = -216.3 kNm
Muyb = -40.73 kNm
Vuxb = 35.27 kN
Vuyb = -116.78 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 5.409
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 41 of 523

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 192.31 kNm
M2 = -216.3 kNm
34 - 12 x (M1/M2) = 44.67
20.44 < 44.67, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -40.73 kNm
M2 = 82.67 kNm
34 - 12 x (M1/M2) = 39.91
20.44 < 39.91, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 192.31 - 192.31
Major Axis Mux (bottom) -216.3 - -216.3
Minor Axis Muy (top) 82.67 - 82.67
Minor Axis Muy (bottom) -40.73 - -40.73

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1027.57 kN
Mux = 192.31 kNm
Muy = 82.67 kNm

Moment Capacity Check


Pt Calculated = 1.15

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 42 of 523

Reinforcement Provided = 4-#20 + 8-#16


Load Angle = Tan-1(Muy/Mux)
= 23.26 deg
MRes = 209.33 kNm
MCap = 285.11 kNm
Capacity Ratio = MRes/ MCap
= 0.734 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 832.26 kN
Muy = 191.69 kNm
Vuy = -116.2814 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 30.44 kNm
Vcy Permissible = 170.96 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 260.27 kN
Mux = 102.83 kNm
Vux = -75.5565 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 52.41 kNm
Vcx Permissible = 172.22 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 43 of 523

= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C3
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 252
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 638.39 kN
Muxt = 179.6 kNm
Muyt = 96 kNm
Vuxt = 58.04 kN
Vuyt = -94.82 kN
Pub = 667.67 kN
Muxb = -152.17 kNm
Muyb = -107.08 kNm
Vuxb = 58.04 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 44 of 523

Vuyb = -94.82 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 45 of 523

K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -152.17 kNm
M2 = 179.6 kNm
34 - 12 x (M1/M2) = 44.17
20.44 < 44.17, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 96 kNm
M2 = -107.08 kNm
34 - 12 x (M1/M2) = 44.76
20.44 < 44.76, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 179.6 - 179.6
Major Axis Mux (bottom) -152.17 - -152.17
Minor Axis Muy (top) 96 - 96
Minor Axis Muy (bottom) -107.08 - -107.08

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 638.39 kN
Mux = 179.6 kNm
Muy = 96 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 28.13 deg
MRes = 203.65 kNm
MCap = 282.46 kNm
Capacity Ratio = MRes/ MCap
= 0.721 < 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 46 of 523

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 1: EX)
Nu = 660.64 kN
Muy = 135.6 kNm
Vuy = 85.3455 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 7.6 kNm
Vcy Permissible = 171.18 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 325.21 kN
Mux = 116.49 kNm
Vux = 78.9979 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 53.48 kNm
Vcx Permissible = 171.66 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 47 of 523

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C3
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 375
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 270.28 kN
Muxt = -3.66 kNm
Muyt = 202.89 kNm
Vuxt = 93.04 kN
Vuyt = 1.82 kN
Pub = 299.57 kN
Muxb = 2.69 kNm
Muyb = -122.67 kNm
Vuxb = 93.04 kN
Vuyb = 1.82 kN

Effective Length Calculation


Calculation Along Major Axis Of Column

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 48 of 523

Joint Column Beam Sizes Beam Stiffness Beta


Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = 2.69 kNm
M2 = -3.66 kNm
34 - 12 x (M1/M2) = 42.84
17.37 < 42.84, Column not slender along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 49 of 523

Column Is Braced Along B


Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -122.67 kNm
M2 = 202.89 kNm
34 - 12 x (M1/M2) = 41.26
20.44 < 41.26, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -3.66 - -3.66
Major Axis Mux (bottom) 2.69 - 2.69
Minor Axis Muy (top) 202.89 - 202.89
Minor Axis Muy (bottom) -122.67 - -122.67

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 270.28 kN
Mux = -3.66 kNm
Muy = 202.89 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.97 deg
MRes = 202.92 kNm
MCap = 274.42 kNm
Capacity Ratio = MRes/ MCap
= 0.739 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 384.95 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 50 of 523

Muy = 1.93 kNm


Vuy = -2.1111 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 72.66 kNm
Vcy Permissible = 359.63 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 235.3 kN
Mux = 96.69 kNm
Vux = 74.9686 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 51.1 kNm
Vcx Permissible = 172.62 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 51 of 523

General Data
Column No. : C4
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 85
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 275.91 kN
Muxt = 4.09 kNm
Muyt = 22.97 kNm
Vuxt = -78.9 kN
Vuyt = -12.49 kN
Pub = 283.12 kN
Muxb = -18.38 kNm
Muyb = 164.96 kNm
Vuxb = -78.9 kN
Vuyb = -12.49 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 52 of 523

Effective Length Factor along Major


= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam 74.125 - 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 4.09 kNm
M2 = -18.38 kNm
34 - 12 x (M1/M2) = 36.67
7.53 < 36.67, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 22.97 kNm
M2 = 164.96 kNm
34 - 12 x (M1/M2) = 32.33
7.53 < 32.33, Column not slender along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 53 of 523

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 4.09 - 4.09
Major Axis Mux (bottom) -18.38 - -18.38
Minor Axis Muy (top) 22.97 - 22.97
Minor Axis Muy (bottom) 164.96 - 164.96

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 283.12 kN
Mux = -18.38 kNm
Muy = 164.96 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 83.64 deg
MRes = 165.98 kNm
MCap = 274 kNm
Capacity Ratio = MRes/ MCap
= 0.606 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 443.19 kN
Muy = 43.81 kNm
Vuy = 121.0526 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 42.06 kNm
Vcy Permissible = 367.93 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 54 of 523

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 777.57 kN
Mux = 165.29 kNm
Vux = -79.1091 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 14.64 kNm
Vcx Permissible = 169.69 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C4
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 55 of 523

Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 131
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 379.48 kN
Muxt = 191.26 kNm
Muyt = 23.25 kNm
Vuxt = 10.37 kN
Vuyt = -115.64 kN
Pub = 393.5 kN
Muxb = -213.36 kNm
Muyb = -13.04 kNm
Vuxb = 10.37 kN
Vuyb = -115.64 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 136.386 6000 x 350 x No Beam 74.125 - 5.409

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 56 of 523

550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 191.26 kNm
M2 = -213.36 kNm
34 - 12 x (M1/M2) = 44.76
20.44 < 44.76, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -13.04 kNm
M2 = 23.25 kNm
34 - 12 x (M1/M2) = 40.73
20.44 < 40.73, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 191.26 - 191.26
Major Axis Mux (bottom) -213.36 - -213.36
Minor Axis Muy (top) 23.25 - 23.25
Minor Axis Muy (bottom) -13.04 - -13.04

Where

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 57 of 523

A = Moments from analysis


B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 393.5 kN
Mux = -213.36 kNm
Muy = -13.04 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 3.5 deg
MRes = 213.76 kNm
MCap = 291.75 kNm
Capacity Ratio = MRes/ MCap
= 0.733 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 983.93 kN
Muy = 193.01 kNm
Vuy = -117.0633 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 2.37 kNm
Vcy Permissible = 170.95 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 249.28 kN
Mux = 101.58 kNm
Vux = -72.8934 kN
λ = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 58 of 523

φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 53.28 kNm
Vcx Permissible = 172.05 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C4
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 59 of 523

Analysis Reference No. = 254


Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 636.48 kN
Muxt = 180.66 kNm
Muyt = 87.2 kNm
Vuxt = 50.22 kN
Vuyt = -95.42 kN
Pub = 665.77 kN
Muxb = -153.24 kNm
Muyb = -88.51 kNm
Vuxb = 50.22 kN
Vuyb = -95.42 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 60 of 523

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -153.24 kNm
M2 = 180.66 kNm
34 - 12 x (M1/M2) = 44.18
20.44 < 44.18, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 87.2 kNm
M2 = -88.51 kNm
34 - 12 x (M1/M2) = 45.82
20.44 < 45.82, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 180.66 - 180.66
Major Axis Mux (bottom) -153.24 - -153.24
Minor Axis Muy (top) 87.2 - 87.2
Minor Axis Muy (bottom) -88.51 - -88.51

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 636.48 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 61 of 523

Mux = 180.66 kNm


Muy = 87.2 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 25.77 deg
MRes = 200.61 kNm
MCap = 287.65 kNm
Capacity Ratio = MRes/ MCap
= 0.697 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 1: EX)
Nu = 662.56 kN
Muy = 135.01 kNm
Vuy = 84.8991 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 6.63 kNm
Vcy Permissible = 171.18 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 321.91 kN
Mux = 104.79 kNm
Vux = 72.696 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 42.41 kNm
Vcx Permissible = 171.82 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 62 of 523

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C4
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 377
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 270.52 kN
Muxt = -3.91 kNm
Muyt = 197.91 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 63 of 523

Vuxt = 91.77 kN
Vuyt = 1.74 kN
Pub = 299.81 kN
Muxb = 2.17 kNm
Muyb = -123.22 kNm
Vuxb = 91.77 kN
Vuyb = 1.74 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 64 of 523

0.009< 0.05, Column shall be designed as non-sway frame


(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = 2.17 kNm
M2 = -3.91 kNm
34 - 12 x (M1/M2) = 40.67
17.37 < 40.67, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -123.22 kNm
M2 = 197.91 kNm
34 - 12 x (M1/M2) = 41.47
20.44 < 41.47, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -3.91 - -3.91
Major Axis Mux (bottom) 2.17 - 2.17
Minor Axis Muy (top) 197.91 - 197.91
Minor Axis Muy (bottom) -123.22 - -123.22

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 270.52 kN
Mux = -3.91 kNm
Muy = 197.91 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 65 of 523

Load Angle = Tan-1(Muy/Mux)


= 88.87 deg
MRes = 197.95 kNm
MCap = 274.36 kNm
Capacity Ratio = MRes/ MCap
= 0.721 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 386.17 kN
Muy = 2.47 kNm
Vuy = -2.1071 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 72.35 kNm
Vcy Permissible = 359.81 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 235.46 kN
Mux = 97.79 kNm
Vux = 74.0166 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 52.17 kNm
Vcx Permissible = 172.44 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 66 of 523

Criterion for spacing of normal


links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C5
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 87
Critical Analysis Load Combination : 23
Load Combination = [19] : 0.68 (LOAD 3: DL) +1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 464.44 kN
Muxt = -43.8 kNm
Muyt = -1.89 kNm
Vuxt = -1.21 kN
Vuyt = 121.05 kN
Pub = 471.66 kN
Muxb = 174.02 kNm
Muyb = 0.28 kNm
Vuxb = -1.21 kN
Vuyb = 121.05 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 67 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam 74.125 - 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -43.8 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 68 of 523

M2 = 174.02 kNm
34 - 12 x (M1/M2) = 37.02
7.53 < 37.02, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 0.28 kNm
M2 = -1.89 kNm
34 - 12 x (M1/M2) = 35.8
7.53 < 35.8, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -43.8 - -43.8
Major Axis Mux (bottom) 174.02 - 174.02
Minor Axis Muy (top) -1.89 - -1.89
Minor Axis Muy (bottom) 0.28 - 0.28

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 471.66 kN
Mux = 174.02 kNm
Muy = 0.28 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 0.09 deg
MRes = 174.02 kNm
MCap = 305.18 kNm
Capacity Ratio = MRes/ MCap
= 0.57 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 69 of 523

[19] : 0.68 (LOAD 3: DL) +1.25


Critical Load Combination = kN
(LOAD 1: EX)
Nu = 464.44 kN
Muy = 43.8 kNm
Vuy = 121.0462 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 46.18 kNm
Vcy Permissible = 370.92 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 309.77 kN
Mux = 154.52 kNm
Vux = -74.8716 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 94.5 kNm
Vcx Permissible = 169.75 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 70 of 523

Spacing 250 --- --- 250 ---

General Data
Column No. : C5
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 133
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 391.9 kN
Muxt = 191.23 kNm
Muyt = 26.66 kNm
Vuxt = 10.62 kN
Vuyt = -115.63 kN
Pub = 405.93 kN
Muxb = -213.36 kNm
Muyb = -10.49 kNm
Vuxb = 10.62 kN
Vuyb = -115.63 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 71 of 523

5000 x 350 x 5000 x 350 x


Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 5.409
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 191.23 kNm
M2 = -213.36 kNm
34 - 12 x (M1/M2) = 44.76
20.44 < 44.76, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -10.49 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 72 of 523

M2 = 26.66 kNm
34 - 12 x (M1/M2) = 38.72
20.44 < 38.72, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 191.23 - 191.23
Major Axis Mux (bottom) -213.36 - -213.36
Minor Axis Muy (top) 26.66 - 26.66
Minor Axis Muy (bottom) -10.49 - -10.49

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 405.93 kN
Mux = -213.36 kNm
Muy = -10.49 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 2.82 deg
MRes = 213.62 kNm
MCap = 293.84 kNm
Capacity Ratio = MRes/ MCap
= 0.727 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 819.38 kN
Muy = 192.35 kNm
Vuy = -116.554 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 73 of 523

mm = 33.6 kNm
Vcy Permissible = 170.95 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 273.09 kN
Mux = 85.79 kNm
Vux = -64.5618 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 32.88 kNm
Vcx Permissible = 172.39 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C5
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 74 of 523

Grade Of Concrete = C21 N/sqmm


Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 256
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 630.51 kN
Muxt = 180.58 kNm
Muyt = 87.89 kNm
Vuxt = 53.56 kN
Vuyt = -95.39 kN
Pub = 659.8 kN
Muxb = -153.18 kNm
Muyb = -99.52 kNm
Vuxb = 53.56 kN
Vuyb = -95.39 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 75 of 523

Joint Column Beam Sizes Beam Stiffness Beta


Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -153.18 kNm
M2 = 180.58 kNm
34 - 12 x (M1/M2) = 44.18
20.44 < 44.18, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 87.89 kNm
M2 = -99.52 kNm
34 - 12 x (M1/M2) = 44.6
20.44 < 44.6, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 76 of 523

Major Axis Mux (top) 180.58 - 180.58


Major Axis Mux (bottom) -153.18 - -153.18
Minor Axis Muy (top) 87.89 - 87.89
Minor Axis Muy (bottom) -99.52 - -99.52

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 630.51 kN
Mux = 180.58 kNm
Muy = 87.89 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 25.95 deg
MRes = 200.83 kNm
MCap = 287.21 kNm
Capacity Ratio = MRes/ MCap
= 0.699 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 1: EX)
Nu = 660.78 kN
Muy = 135.02 kNm
Vuy = 84.9264 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 6.99 kNm
Vcy Permissible = 171.18 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 77 of 523

[22] : 0.68 (LOAD 3: DL) -1.25


Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 316.73 kN
Mux = 107.24 kNm
Vux = 71.7422 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 45.88 kNm
Vcx Permissible = 171.57 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C5
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 78 of 523

Clear Floor Height @ luy = 2950 mm


No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 379
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 267.36 kN
Muxt = -3.78 kNm
Muyt = 191.8 kNm
Vuxt = 88.69 kN
Vuyt = 1.7 kN
Pub = 296.65 kN
Muxb = 2.18 kNm
Muyb = -118.55 kNm
Vuxb = 88.69 kN
Vuyb = 1.7 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 79 of 523

Top 136.386 550 No Beam 74.125 - 1.837


Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = 2.18 kNm
M2 = -3.78 kNm
34 - 12 x (M1/M2) = 40.92
17.37 < 40.92, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -118.55 kNm
M2 = 191.8 kNm
34 - 12 x (M1/M2) = 41.42
20.44 < 41.42, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -3.78 - -3.78
Major Axis Mux (bottom) 2.18 - 2.18
Minor Axis Muy (top) 191.8 - 191.8
Minor Axis Muy (bottom) -118.55 - -118.55

Where
A = Moments from analysis
B = Moment due to slenderness effect

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 80 of 523

C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 267.36 kN
Mux = -3.78 kNm
Muy = 191.8 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.87 deg
MRes = 191.83 kNm
MCap = 273.88 kNm
Capacity Ratio = MRes/ MCap
= 0.7 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 383.86 kN
Muy = 2.46 kNm
Vuy = -2.1521 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 71.92 kNm
Vcy Permissible = 359.47 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 232.53 kN
Mux = 93.68 kNm
Vux = 71.2639 kN
λ = 1
φ = 0.65
deff = 450 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 81 of 523

ρw = 0.006
mm = 48.63 kNm
Vcx Permissible = 172.48 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C6
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 89
Critical Analysis Load Combination : 25

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 82 of 523

Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)


Critical Location = Bottom Joint
Put = 438.96 kN
Muxt = 41.88 kNm
Muyt = 1.1 kNm
Vuxt = -3.19 kN
Vuyt = -119.51 kN
Pub = 446.17 kN
Muxb = -173.18 kNm
Muyb = 6.83 kNm
Vuxb = -3.19 kN
Vuyb = -119.51 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam 74.125 - 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009

0.009< 0.05, Column shall be designed as non-sway frame

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 83 of 523

(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 41.88 kNm
M2 = -173.18 kNm
34 - 12 x (M1/M2) = 36.9
7.53 < 36.9, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 1.1 kNm
M2 = 6.83 kNm
34 - 12 x (M1/M2) = 32.08
7.53 < 32.08, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 41.88 - 41.88
Major Axis Mux (bottom) -173.18 - -173.18
Minor Axis Muy (top) 1.1 - 1.1
Minor Axis Muy (bottom) 6.83 - 6.83

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 446.17 kN
Mux = -173.18 kNm
Muy = 6.83 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 84 of 523

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 2.26 deg
MRes = 173.31 kNm
MCap = 300.2 kNm
Capacity Ratio = MRes/ MCap
= 0.577 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 451.66 kN
Muy = 43.83 kNm
Vuy = 121.0662 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 43.68 kNm
Vcy Permissible = 369.12 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 602.68 kN
Mux = 140.81 kNm
Vux = 67.282 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 24.04 kNm
Vcx Permissible = 169.69 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 85 of 523

Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C6
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 135
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 370.15 kN
Muxt = 191.14 kNm
Muyt = 15.58 kNm
Vuxt = 5.21 kN
Vuyt = -115.59 kN
Pub = 384.18 kN
Muxb = -213.3 kNm
Muyb = -2.64 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 86 of 523

Vuxb = 5.21 kN
Vuyb = -115.59 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 5.409
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 87 of 523

Slenderness Check along D


K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 191.14 kNm
M2 = -213.3 kNm
34 - 12 x (M1/M2) = 44.75
20.44 < 44.75, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -2.64 kNm
M2 = 15.58 kNm
34 - 12 x (M1/M2) = 36.03
20.44 < 36.03, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 191.14 - 191.14
Major Axis Mux (bottom) -213.3 - -213.3
Minor Axis Muy (top) 15.58 - 15.58
Minor Axis Muy (bottom) -2.64 - -2.64

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 384.18 kN
Mux = -213.3 kNm
Muy = -2.64 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 0.71 deg
MRes = 213.32 kNm
MCap = 291.82 kNm
Capacity Ratio = MRes/ MCap

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 88 of 523

= 0.731 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 972.05 kN
Muy = 192.76 kNm
Vuy = -116.9565 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 4.42 kNm
Vcy Permissible = 170.96 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 262.68 kN
Mux = 84.5 kNm
Vux = -61.8874 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 33.6 kNm
Vcx Permissible = 172.2 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 89 of 523

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C6
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 258
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 629.27 kN
Muxt = 180.4 kNm
Muyt = 79.06 kNm
Vuxt = 45.75 kN
Vuyt = -95.26 kN
Pub = 658.56 kN
Muxb = -152.92 kNm
Muyb = -81.03 kNm
Vuxb = 45.75 kN
Vuyb = -95.26 kN

Effective Length Calculation

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 90 of 523

Calculation Along Major Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -152.92 kNm
M2 = 180.4 kNm
34 - 12 x (M1/M2) = 44.17

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 91 of 523

20.44 < 44.17, Column not slender along D


Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 79.06 kNm
M2 = -81.03 kNm
34 - 12 x (M1/M2) = 45.71
20.44 < 45.71, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 180.4 - 180.4
Major Axis Mux (bottom) -152.92 - -152.92
Minor Axis Muy (top) 79.06 - 79.06
Minor Axis Muy (bottom) -81.03 - -81.03

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 629.27 kN
Mux = 180.4 kNm
Muy = 79.06 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 23.66 deg
MRes = 196.97 kNm
MCap = 292.14 kNm
Capacity Ratio = MRes/ MCap
= 0.674 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 1: EX)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 92 of 523

Nu = 663.72 kN
Muy = 135.34 kNm
Vuy = 85.0697 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 6.74 kNm
Vcy Permissible = 171.17 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 313.75 kN
Mux = 95.6 kNm
Vux = 65.4574 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 34.81 kNm
Vcx Permissible = 171.73 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 93 of 523

General Data
Column No. : C6
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 381
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 267.22 kN
Muxt = -3.97 kNm
Muyt = 186.74 kNm
Vuxt = 87.38 kN
Vuyt = 1.8 kN
Pub = 296.51 kN
Muxb = 2.31 kNm
Muyb = -119.01 kNm
Vuxb = 87.38 kN
Vuyb = 1.8 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
Top 136.386 5000 x 350 x 5000 x 350 x 88.95 88.95 0.767

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 94 of 523

550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = 2.31 kNm
M2 = -3.97 kNm
34 - 12 x (M1/M2) = 40.99
17.37 < 40.99, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -119.01 kNm
M2 = 186.74 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 95 of 523

34 - 12 x (M1/M2) = 41.65
20.44 < 41.65, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -3.97 - -3.97
Major Axis Mux (bottom) 2.31 - 2.31
Minor Axis Muy (top) 186.74 - 186.74
Minor Axis Muy (bottom) -119.01 - -119.01

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 267.22 kN
Mux = -3.97 kNm
Muy = 186.74 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.78 deg
MRes = 186.78 kNm
MCap = 273.77 kNm
Capacity Ratio = MRes/ MCap
= 0.682 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 384.4 kN
Muy = 2.48 kNm
Vuy = -2.1341 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 72 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 96 of 523

Vcy Permissible = 359.55 kN


Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 232.47 kN
Mux = 94.72 kNm
Vux = 70.2998 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 49.68 kNm
Vcx Permissible = 172.29 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C7
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 97 of 523

Grade Of Steel = Fy420 N/sqmm


Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 91
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 429.25 kN
Muxt = 41.54 kNm
Muyt = 2.05 kNm
Vuxt = -5.5 kN
Vuyt = -119.24 kN
Pub = 436.47 kN
Muxb = -173.03 kNm
Muyb = 11.94 kNm
Vuxb = -5.5 kN
Vuyb = -119.24 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 98 of 523

Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam 74.125 - 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 41.54 kNm
M2 = -173.03 kNm
34 - 12 x (M1/M2) = 36.88
7.53 < 36.88, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 2.05 kNm
M2 = 11.94 kNm
34 - 12 x (M1/M2) = 31.94
7.53 < 31.94, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 41.54 - 41.54
Major Axis Mux (bottom) -173.03 - -173.03
Minor Axis Muy (top) 2.05 - 2.05
Minor Axis Muy (bottom) 11.94 - 11.94

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 99 of 523

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 436.47 kN
Mux = -173.03 kNm
Muy = 11.94 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 3.95 deg
MRes = 173.44 kNm
MCap = 297.47 kNm
Capacity Ratio = MRes/ MCap
= 0.583 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 453.29 kN
Muy = 43.93 kNm
Vuy = 121.1447 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 43.9 kNm
Vcy Permissible = 369.35 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 588.32 kN
Mux = 129.11 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 100 of 523

Vux = 61.7952 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 15.12 kNm
Vcx Permissible = 169.69 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C7
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 101 of 523

Load Data
Analysis Reference No. = 137
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 362.24 kN
Muxt = 190.57 kNm
Muyt = 11.08 kNm
Vuxt = 2.36 kN
Vuyt = -115.3 kN
Pub = 376.26 kN
Muxb = -212.88 kNm
Muyb = 2.82 kNm
Vuxb = 2.36 kN
Vuyb = -115.3 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 5.409
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 102 of 523

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 190.57 kNm
M2 = -212.88 kNm
34 - 12 x (M1/M2) = 44.74
20.44 < 44.74, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 2.82 kNm
M2 = 11.08 kNm
34 - 12 x (M1/M2) = 30.94
20.44 < 30.94, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 190.57 - 190.57
Major Axis Mux (bottom) -212.88 - -212.88
Minor Axis Muy (top) 11.08 - 11.08
Minor Axis Muy (bottom) 2.82 - 2.82

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 103 of 523

Pu = 376.26 kN
Mux = -212.88 kNm
Muy = 2.82 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 0.76 deg
MRes = 212.9 kNm
MCap = 290.59 kNm
Capacity Ratio = MRes/ MCap
= 0.733 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 958.55 kN
Muy = 191.73 kNm
Vuy = -116.3982 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 6.01 kNm
Vcy Permissible = 170.96 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 266.23 kN
Mux = 76.72 kNm
Vux = -56.6926 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 25.14 kNm
Vcx Permissible = 172.26 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 104 of 523

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C7
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 260
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 628.18 kN
Muxt = -164.4 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 105 of 523

Muyt = 89.67 kNm


Vuxt = 50.11 kN
Vuyt = 85.97 kN
Pub = 657.46 kN
Muxb = 136.43 kNm
Muyb = -85.65 kNm
Vuxb = 50.11 kN
Vuyb = 85.97 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 106 of 523

       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 136.43 kNm
M2 = -164.4 kNm
34 - 12 x (M1/M2) = 43.96
20.44 < 43.96, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -85.65 kNm
M2 = 89.67 kNm
34 - 12 x (M1/M2) = 45.46
20.44 < 45.46, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -164.4 - -164.4
Major Axis Mux (bottom) 136.43 - 136.43
Minor Axis Muy (top) 89.67 - 89.67
Minor Axis Muy (bottom) -85.65 - -85.65

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 628.18 kN
Mux = -164.4 kNm
Muy = 89.67 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 107 of 523

Load Angle = Tan-1(Muy/Mux)


= 28.61 deg
MRes = 187.27 kNm
MCap = 281.39 kNm
Capacity Ratio = MRes/ MCap
= 0.666 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 1: EX)
Nu = 657.46 kN
Muy = 136.43 kNm
Vuy = 85.973 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 9.04 kNm
Vcy Permissible = 171.19 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 307.02 kN
Mux = 90.31 kNm
Vux = 61.5253 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 30.82 kNm
Vcx Permissible = 171.69 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 108 of 523

Criterion for spacing of normal


links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C7
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 383
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 261.83 kN
Muxt = -7.93 kNm
Muyt = 175.7 kNm
Vuxt = 82.88 kN
Vuyt = 3.9 kN
Pub = 291.12 kN
Muxb = 5.7 kNm
Muyb = -114.32 kNm
Vuxb = 82.88 kN
Vuyb = 3.9 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 109 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 110 of 523

Kluy /r = 17.37
M1 = 5.7 kNm
M2 = -7.93 kNm
34 - 12 x (M1/M2) = 42.63
17.37 < 42.63, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -114.32 kNm
M2 = 175.7 kNm
34 - 12 x (M1/M2) = 41.81
20.44 < 41.81, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -7.93 - -7.93
Major Axis Mux (bottom) 5.7 - 5.7
Minor Axis Muy (top) 175.7 - 175.7
Minor Axis Muy (bottom) -114.32 - -114.32

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 261.83 kN
Mux = -7.93 kNm
Muy = 175.7 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.42 deg
MRes = 175.88 kNm
MCap = 271.71 kNm
Capacity Ratio = MRes/ MCap
= 0.647 < 1

Design Of Shear

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 111 of 523

Design for shear along D


Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 379.94 kN
Muy = 2.36 kNm
Vuy = 0.6985 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 71.26 kNm
Vcy Permissible = 358.91 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 227.44 kN
Mux = 91 kNm
Vux = 66.5952 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 46.93 kNm
Vcx Permissible = 172.19 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 112 of 523

Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C8
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 93
Critical Analysis Load Combination : 23
Load Combination = [19] : 0.68 (LOAD 3: DL) +1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 270.47 kN
Muxt = -51.35 kNm
Muyt = 1.19 kNm
Vuxt = 9.29 kN
Vuyt = 127.02 kN
Pub = 277.68 kN
Muxb = 177.23 kNm
Muyb = -15.52 kNm
Vuxb = 9.29 kN
Vuyb = 127.02 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 113 of 523

N-M mm mm N-M N-M


Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam 74.125 - 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -51.35 kNm
M2 = 177.23 kNm
34 - 12 x (M1/M2) = 37.48
7.53 < 37.48, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 114 of 523

M1 = 1.19 kNm
M2 = -15.52 kNm
34 - 12 x (M1/M2) = 34.92
7.53 < 34.92, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -51.35 - -51.35
Major Axis Mux (bottom) 177.23 - 177.23
Minor Axis Muy (top) 1.19 - 1.19
Minor Axis Muy (bottom) -15.52 - -15.52

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 277.68 kN
Mux = 177.23 kNm
Muy = -15.52 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 5 deg
MRes = 177.9 kNm
MCap = 273.25 kNm
Capacity Ratio = MRes/ MCap
= 0.651 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 1: EX)
Nu = 655.76 kN
Muy = 57.49 kNm
Vuy = 131.8268 kN
λ = 1
φ = 0.65
deff = 450 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 115 of 523

ρw = 0.006
mm = 69.56 kNm
Vcy Permissible = 396.76 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 411.99 kN
Mux = 119 kNm
Vux = 59.2641 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 39.17 kNm
Vcx Permissible = 169.88 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C8
Level : 1.8m To 5.3m

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 116 of 523

Design Code = ACI 318M - 2011


Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 139
Critical Analysis Load Combination : 23
Load Combination = [19] : 0.68 (LOAD 3: DL) +1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 216.92 kN
Muxt = -203.3 kNm
Muyt = 22.19 kNm
Vuxt = 12.08 kN
Vuyt = 120.84 kN
Pub = 230.95 kN
Muxb = 219.53 kNm
Muyb = -20.07 kNm
Vuxb = 12.08 kN
Vuyb = 120.84 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 117 of 523

Joint Column Beam Sizes Beam Stiffness Beta


Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 5.409
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -203.3 kNm
M2 = 219.53 kNm
34 - 12 x (M1/M2) = 45.11
20.44 < 45.11, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -20.07 kNm
M2 = 22.19 kNm
34 - 12 x (M1/M2) = 44.85
20.44 < 44.85, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 118 of 523

Major Axis Mux (top) -203.3 - -203.3


Major Axis Mux (bottom) 219.53 - 219.53
Minor Axis Muy (top) 22.19 - 22.19
Minor Axis Muy (bottom) -20.07 - -20.07

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 230.95 kN
Mux = 219.53 kNm
Muy = -20.07 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 5.22 deg
MRes = 220.44 kNm
MCap = 265.63 kNm
Capacity Ratio = MRes/ MCap
= 0.83 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 545.22 kN
Muy = 172.99 kNm
Vuy = -107.7938 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 67.35 kNm
Vcy Permissible = 171.12 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 119 of 523

[22] : 0.68 (LOAD 3: DL) -1.25


Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 317.1 kN
Mux = 99.04 kNm
Vux = 63.8208 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 37.6 kNm
Vcx Permissible = 171.33 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C8
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 120 of 523

Clear Floor Height @ luy = 2950 mm


No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 262
Critical Analysis Load Combination : 23
Load Combination = [19] : 0.68 (LOAD 3: DL) +1.25 (LOAD 1: EX)
Critical Location = Top Joint
Put = 135.04 kN
Muxt = -182.9 kNm
Muyt = 25.63 kNm
Vuxt = 13.22 kN
Vuyt = 97.18 kN
Pub = 149.06 kN
Muxb = 157.14 kNm
Muyb = -20.62 kNm
Vuxb = 13.22 kN
Vuyb = 97.18 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 121 of 523

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 157.14 kNm
M2 = -182.9 kNm
34 - 12 x (M1/M2) = 44.31
20.44 < 44.31, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -20.62 kNm
M2 = 25.63 kNm
34 - 12 x (M1/M2) = 43.65
20.44 < 43.65, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -182.9 - -182.9
Major Axis Mux (bottom) 157.14 - 157.14
Minor Axis Muy (top) 25.63 - 25.63
Minor Axis Muy (bottom) -20.62 - -20.62

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 122 of 523

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 135.04 kN
Mux = -182.9 kNm
Muy = 25.63 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 7.98 deg
MRes = 184.69 kNm
MCap = 249.54 kNm
Capacity Ratio = MRes/ MCap
= 0.74 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 366.58 kN
Muy = 125.1 kNm
Vuy = -78.9956 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 54.08 kNm
Vcy Permissible = 171.2 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 361.1 kN
Mux = 86.75 kNm
Vux = 58.4542 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 123 of 523

mm = 16.79 kNm
Vcx Permissible = 171.62 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C8
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 385
Critical Analysis Load Combination : 15

Load Combination = [11] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 124 of 523

(LOAD 1: EX)
Critical Location = Top Joint
Put = 127.78 kN
Muxt = -128.03 kNm
Muyt = 40.82 kNm
Vuxt = 21.85 kN
Vuyt = 63.05 kN
Pub = 157.06 kN
Muxb = 92.59 kNm
Muyb = -35.64 kNm
Vuxb = 21.85 kN
Vuyb = 63.05 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 125 of 523

0.008< 0.05, Column shall be designed as non-sway frame


(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = 92.59 kNm
M2 = -128.03 kNm
34 - 12 x (M1/M2) = 42.68
17.37 < 42.68, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -35.64 kNm
M2 = 40.82 kNm
34 - 12 x (M1/M2) = 44.48
20.44 < 44.48, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -128.03 - -128.03
Major Axis Mux (bottom) 92.59 - 92.59
Minor Axis Muy (top) 40.82 - 40.82
Minor Axis Muy (bottom) -35.64 - -35.64

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 127.78 kN
Mux = -128.03 kNm
Muy = 40.82 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 126 of 523

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 17.68 deg
MRes = 134.38 kNm
MCap = 248.26 kNm
Capacity Ratio = MRes/ MCap
= 0.541 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 131.28 kN
Muy = 84.73 kNm
Vuy = 58.0598 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 59.29 kNm
Vcy Permissible = 171.73 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 2: EZ)
Nu = 139.93 kN
Mux = 13.89 kNm
Vux = -1.6984 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 13.22 kNm
Vcx Permissible = 322.37 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 127 of 523

Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C9
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 95
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = -69.29 kN
Muxt = -14.46 kNm
Muyt = 16.7 kNm
Vuxt = -0.03 kN
Vuyt = -74.91 kN
Pub = -62.08 kN
Muxb = -149.27 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 128 of 523

Muyb = 16.75 kNm


Vuxb = -0.03 kN
Vuyb = -74.91 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x
Top 265.195 No Beam - 88.95 4.517
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam 74.125 - 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 129 of 523

Major Axis Mux (top) -14.46 - -14.46


Major Axis Mux (bottom) -149.27 - -149.27
Minor Axis Muy (top) 16.7 - 16.7
Minor Axis Muy (bottom) 16.75 - 16.75

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = -62.08 kN
Mux = -149.27 kNm
Muy = 16.75 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 6.4 deg
MRes = 150.2 kNm
MCap = 214.88 kNm
Capacity Ratio = MRes/ MCap
= 0.699 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 69.29 kN
Muy = 14.46 kNm
Vuy = -74.9147 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 1.03 kNm
Vcy Permissible = 216.08 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 18

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 130 of 523

[14] : 1.42 (LOAD 3: DL) +0.5


Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 2: EZ)
Nu = 472.99 kN
Mux = 115.05 kNm
Vux = 71.8512 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 23.41 kNm
Vcx Permissible = 171.13 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C9
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 131 of 523

Clear Floor Height @ luy = 2950 mm


No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 141
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = -56.45 kN
Muxt = 119.32 kNm
Muyt = -3.85 kNm
Vuxt = -4.24 kN
Vuyt = -78.17 kN
Pub = -42.42 kN
Muxb = -154.21 kNm
Muyb = 11 kNm
Vuxb = -4.24 kN
Vuyb = -78.17 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x
Bottom 136.386 No Beam - 88.95 4.517
550
5000 x 350 x
Top 136.386 No Beam - 88.95 3.068
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 5.409
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 132 of 523

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 119.32 - 119.32
Major Axis Mux (bottom) -154.21 - -154.21
Minor Axis Muy (top) -3.85 - -3.85
Minor Axis Muy (bottom) 11 - 11

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = -42.42 kN
Mux = -154.21 kNm
Muy = 11 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 4.08 deg
MRes = 154.6 kNm
MCap = 218.07 kNm
Capacity Ratio = MRes/ MCap
= 0.709 < 1

Design Of Shear
Design for shear along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 133 of 523

Critical Analysis Load Combination : 17


[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 55 kN
Muy = 116.51 kNm
Vuy = -77.218 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 105.86 kNm
Vcy Permissible = 171.51 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 210.4 kN
Mux = 88.96 kNm
Vux = 58.6139 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 48.2 kNm
Vcx Permissible = 171.47 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 134 of 523

Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C9
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 264
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Top Joint
Put = -20.16 kN
Muxt = 113.66 kNm
Muyt = -2.34 kNm
Vuxt = -0.54 kN
Vuyt = -53.82 kN
Pub = -6.13 kN
Muxb = -74.66 kNm
Muyb = -0.45 kNm
Vuxb = -0.54 kN
Vuyb = -53.82 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 135 of 523

5000 x 350 x
Bottom 136.386 No Beam - 88.95 3.068
550
5000 x 350 x
Top 136.386 No Beam - 88.95 3.068
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 113.66 - 113.66
Major Axis Mux (bottom) -74.66 - -74.66
Minor Axis Muy (top) -2.34 - -2.34
Minor Axis Muy (bottom) -0.45 - -0.45

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 136 of 523

Pu = -20.16 kN
Mux = 113.66 kNm
Muy = -2.34 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 1.18 deg
MRes = 113.68 kNm
MCap = 222.16 kNm
Capacity Ratio = MRes/ MCap
= 0.512 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 209.64 kN
Muy = 7.93 kNm
Vuy = 5.7567 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 32.69 kNm
Vcy Permissible = 333.39 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 235.48 kN
Mux = 31.83 kNm
Vux = 20.8999 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 13.8 kNm
Vcx Permissible = 337.39 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 137 of 523

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C9
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 387
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 51.55 kN
Muxt = -67.82 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 138 of 523

Muyt = 13.19 kNm


Vuxt = 7.86 kN
Vuyt = 26.9 kN
Pub = 80.83 kN
Muxb = 26.29 kNm
Muyb = -14.3 kNm
Vuxb = 7.86 kN
Vuyb = 26.9 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x
Bottom 136.386 No Beam - 88.95 3.068
550
5000 x 350 x
Top 136.386 No Beam - 88.95 1.534
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam 74.125 - 3.674
550
6000 x 350 x
Top 136.386 No Beam 74.125 - 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 139 of 523

       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 26.29 kNm
M2 = -67.82 kNm
34 - 12 x (M1/M2) = 38.65
20.44 < 38.65, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 13.19 kNm
M2 = -14.3 kNm
34 - 12 x (M1/M2) = 45.07
20.44 < 45.07, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -67.82 - -67.82
Major Axis Mux (bottom) 26.29 - 26.29
Minor Axis Muy (top) 13.19 - 13.19
Minor Axis Muy (bottom) -14.3 - -14.3

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 51.55 kN
Mux = -67.82 kNm
Muy = 13.19 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 140 of 523

Load Angle = Tan-1(Muy/Mux)


= 11.01 deg
MRes = 69.1 kNm
MCap = 235.02 kNm
Capacity Ratio = MRes/ MCap
= 0.294 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 76.76 kN
Muy = 8.99 kNm
Vuy = 6.782 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 5.89 kNm
Vcy Permissible = 312.04 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 1: EX)
Nu = 80.83 kN
Mux = 14.3 kNm
Vux = 7.8569 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 1.36 kNm
Vcx Permissible = 312.72 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 141 of 523

Criterion for spacing of normal


links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C10
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 103
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 1763.03 kN
Muxt = 27.05 kNm
Muyt = 80.54 kNm
Vuxt = 181.83 kN
Vuyt = -20.82 kN
Pub = 1778.09 kN
Muxb = -10.42 kNm
Muyb = -246.66 kNm
Vuxb = 181.83 kN
Vuyb = -20.82 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 142 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x
Top 265.195 No Beam 88.95 - 4.517
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
2400 x 350 x 6000 x 350 x
Top 265.195 185.312 74.125 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 143 of 523

M1 = -10.42 kNm
M2 = 27.05 kNm
34 - 12 x (M1/M2) = 38.62
7.53 < 38.62, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 80.54 kNm
M2 = -246.66 kNm
34 - 12 x (M1/M2) = 37.92
7.53 < 37.92, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 27.05 - 27.05
Major Axis Mux (bottom) -10.42 - -10.42
Minor Axis Muy (top) 80.54 - 80.54
Minor Axis Muy (bottom) -246.66 - -246.66

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1778.09 kN
Mux = -10.42 kNm
Muy = -246.66 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 87.58 deg
MRes = 246.88 kNm
MCap = 292.13 kNm
Capacity Ratio = MRes/ MCap
= 0.845 < 1

Design Of Shear
Design for shear along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 144 of 523

Critical Analysis Load Combination : 25


[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 776.27 kN
Muy = 162.76 kNm
Vuy = -91.4098 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 12.35 kNm
Vcy Permissible = 172.26 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 2: EZ)
Nu = 1778.09 kN
Mux = 246.66 kNm
Vux = 181.8264 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 97.85 kNm
Vcx Permissible = 523.28 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 145 of 523

Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C10
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 150
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 138.74 kN
Muxt = -9.57 kNm
Muyt = -316.18 kNm
Vuxt = -184.94 kN
Vuyt = 1.38 kN
Pub = 152.76 kN
Muxb = -4.74 kNm
Muyb = 330.93 kNm
Vuxb = -184.94 kN
Vuyb = 1.38 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 146 of 523

5000 x 350 x
Bottom 136.386 No Beam 88.95 - 4.517
550
5000 x 350 x 2250 x 350 x
Top 136.386 88.95 197.666 0.952
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.86
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.548
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.86
r = 144.34 mm
Kluy /r = 17.58
M1 = -4.74 kNm
M2 = -9.57 kNm
34 - 12 x (M1/M2) = 28.05
17.58 < 28.05, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 147 of 523

M1 = -316.18 kNm
M2 = 330.93 kNm
34 - 12 x (M1/M2) = 45.47
20.44 < 45.47, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -9.57 - -9.57
Major Axis Mux (bottom) -4.74 - -4.74
Minor Axis Muy (top) -316.18 - -316.18
Minor Axis Muy (bottom) 330.93 - 330.93

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 152.76 kN
Mux = -4.74 kNm
Muy = 330.93 kNm

Moment Capacity Check


Pt Calculated = 1.79
Reinforcement Provided = 4-#25 + 8-#20
Load Angle = Tan-1(Muy/Mux)
= 89.18 deg
MRes = 330.96 kNm
MCap = 363.17 kNm
Capacity Ratio = MRes/ MCap
= 0.911 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 255.66 kN
Muy = 136.12 kNm
Vuy = 84.1072 kN
λ = 1
φ = 0.65
deff = 447.5 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 148 of 523

ρw = 0.009
mm = 86.5 kNm
Vcy Permissible = 173.47 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 1211.92 kN
Mux = 257.23 kNm
Vux = 158.0733 kN
λ = 1
φ = 0.65
deff = 447.5 mm
ρw = 0.009
mm = 22.04 kNm
Vcx Permissible = 173.42 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 6.25 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C10
Level : 5.3m To 8.8m

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 149 of 523

Design Code = ACI 318M - 2011


Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 273
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 544.98 kN
Muxt = -57.66 kNm
Muyt = -321.42 kNm
Vuxt = -177.04 kN
Vuyt = 31.21 kN
Pub = 574.26 kN
Muxb = 51.53 kNm
Muyb = 298.06 kNm
Vuxb = -177.04 kN
Vuyb = 31.21 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 2250 x 350 x
Bottom 136.386 88.95 197.666 0.952
550 550
5000 x 350 x 2250 x 350 x
Top 136.386 88.95 197.666 0.952
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.77
Axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 150 of 523

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.77
r = 144.34 mm
Kluy /r = 15.74
M1 = 51.53 kNm
M2 = -57.66 kNm
34 - 12 x (M1/M2) = 44.72
15.74 < 44.72, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 298.06 kNm
M2 = -321.42 kNm
34 - 12 x (M1/M2) = 45.13
20.44 < 45.13, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 151 of 523

A B C
Major Axis Mux (top) -57.66 - -57.66
Major Axis Mux (bottom) 51.53 - 51.53
Minor Axis Muy (top) -321.42 - -321.42
Minor Axis Muy (bottom) 298.06 - 298.06

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 544.98 kN
Mux = -57.66 kNm
Muy = -321.42 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 79.83 deg
MRes = 326.55 kNm
MCap = 352.41 kNm
Capacity Ratio = MRes/ MCap
= 0.927 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 181.54 kN
Muy = 97.23 kNm
Vuy = 67.6021 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 62.06 kNm
Vcy Permissible = 174 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 18

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 152 of 523

[14] : 1.42 (LOAD 3: DL) +0.5


Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 2: EZ)
Nu = 821.13 kN
Mux = 167.54 kNm
Vux = 104.6621 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 8.45 kNm
Vcx Permissible = 173.08 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C10
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 153 of 523

Clear Floor Height @ luy = 2950 mm


No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 396
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 155.91 kN
Muxt = 56.55 kNm
Muyt = -177.16 kNm
Vuxt = -91.67 kN
Vuyt = -13.12 kN
Pub = 185.2 kN
Muxb = 10.65 kNm
Muyb = 143.61 kNm
Vuxb = -91.67 kN
Vuyb = -13.12 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 2250 x 350 x
Bottom 136.386 88.95 197.666 0.952
550 550
5000 x 350 x
Top 136.386 No Beam 88.95 - 1.534
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.86
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 154 of 523

Top 136.386 550 550 185.312 74.125 0.526


Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.86
r = 144.34 mm
Kluy /r = 17.58
M1 = 10.65 kNm
M2 = 56.55 kNm
34 - 12 x (M1/M2) = 31.74
17.58 < 31.74, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = 143.61 kNm
M2 = -177.16 kNm
34 - 12 x (M1/M2) = 43.73
16.55 < 43.73, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 56.55 - 56.55
Major Axis Mux (bottom) 10.65 - 10.65
Minor Axis Muy (top) -177.16 - -177.16
Minor Axis Muy (bottom) 143.61 - 143.61

Where
A = Moments from analysis
B = Moment due to slenderness effect

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 155 of 523

C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 155.91 kN
Mux = 56.55 kNm
Muy = -177.16 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 72.3 deg
MRes = 185.96 kNm
MCap = 252.79 kNm
Capacity Ratio = MRes/ MCap
= 0.736 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 279.16 kN
Muy = 7.03 kNm
Vuy = -22.5183 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 47.05 kNm
Vcy Permissible = 344.04 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 56.19 kN
Mux = 111.22 kNm
Vux = -73.6224 kN
λ = 1
φ = 0.65
deff = 450 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 156 of 523

ρw = 0.006
mm = 100.33 kNm
Vcx Permissible = 171.5 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C11
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 105
Critical Analysis Load Combination : 24

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 157 of 523

Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)


Critical Location = Bottom Joint
Put = 102.23 kN
Muxt = -1.47 kNm
Muyt = -85.5 kNm
Vuxt = -177.86 kN
Vuyt = -0.22 kN
Pub = 109.44 kN
Muxb = -1.87 kNm
Muyb = 234.57 kNm
Vuxb = -177.86 kN
Vuyb = -0.22 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
2400 x 350 x 6000 x 350 x
Top 265.195 185.312 74.125 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009

0.009< 0.05, Column shall be designed as non-sway frame

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 158 of 523

(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -1.47 kNm
M2 = -1.87 kNm
34 - 12 x (M1/M2) = 24.57
7.53 < 24.57, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = -85.5 kNm
M2 = 234.57 kNm
34 - 12 x (M1/M2) = 38.37
7.53 < 38.37, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -1.47 - -1.47
Major Axis Mux (bottom) -1.87 - -1.87
Minor Axis Muy (top) -85.5 - -85.5
Minor Axis Muy (bottom) 234.57 - 234.57

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 109.44 kN
Mux = -1.87 kNm
Muy = 234.57 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 159 of 523

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 89.54 deg
MRes = 234.58 kNm
MCap = 246.43 kNm
Capacity Ratio = MRes/ MCap
= 0.952 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 569.96 kN
Muy = 45.43 kNm
Vuy = -125.9945 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 65 kNm
Vcy Permissible = 385.39 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 2: EZ)
Nu = 1905.95 kN
Mux = 238.36 kNm
Vux = 183.2874 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 130.92 kNm
Vcx Permissible = 535.8 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 160 of 523

Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C11
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 152
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 182.63 kN
Muxt = 5.66 kNm
Muyt = -295.23 kNm
Vuxt = -172.46 kN
Vuyt = -3.26 kN
Pub = 196.66 kN
Muxb = -5.73 kNm
Muyb = 308.2 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 161 of 523

Vuxb = -172.46 kN
Vuyb = -3.26 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.548
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 162 of 523

Slenderness Check along D


K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 5.66 kNm
M2 = -5.73 kNm
34 - 12 x (M1/M2) = 45.86
20.44 < 45.86, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -295.23 kNm
M2 = 308.2 kNm
34 - 12 x (M1/M2) = 45.5
20.44 < 45.5, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 5.66 - 5.66
Major Axis Mux (bottom) -5.73 - -5.73
Minor Axis Muy (top) -295.23 - -295.23
Minor Axis Muy (bottom) 308.2 - 308.2

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 196.66 kN
Mux = -5.73 kNm
Muy = 308.2 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 88.94 deg
MRes = 308.25 kNm
MCap = 319.99 kNm
Capacity Ratio = MRes/ MCap

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 163 of 523

= 0.963 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 1003.52 kN
Muy = 196.74 kNm
Vuy = 118.4485 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 2.31 kNm
Vcy Permissible = 172.79 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 785.54 kN
Mux = 253.23 kNm
Vux = 155.0688 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 101.03 kNm
Vcx Permissible = 172.92 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 164 of 523

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C11
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 275
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 177.62 kN
Muxt = 10.21 kNm
Muyt = -266.11 kNm
Vuxt = -145.34 kN
Vuyt = -5.59 kN
Pub = 191.64 kN
Muxb = -9.35 kNm
Muyb = 242.45 kNm
Vuxb = -145.34 kN
Vuyb = -5.59 kN

Effective Length Calculation


Calculation Along Major Axis Of Column

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 165 of 523

Joint Column Beam Sizes Beam Stiffness Beta


Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -9.35 kNm
M2 = 10.21 kNm
34 - 12 x (M1/M2) = 44.99
20.44 < 44.99, Column not slender along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 166 of 523

Column Is Braced Along B


Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 242.45 kNm
M2 = -266.11 kNm
34 - 12 x (M1/M2) = 44.93
20.44 < 44.93, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 10.21 - 10.21
Major Axis Mux (bottom) -9.35 - -9.35
Minor Axis Muy (top) -266.11 - -266.11
Minor Axis Muy (bottom) 242.45 - 242.45

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 177.62 kN
Mux = 10.21 kNm
Muy = -266.11 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 87.8 deg
MRes = 266.31 kNm
MCap = 316.08 kNm
Capacity Ratio = MRes/ MCap
= 0.843 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 657.63 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 167 of 523

Muy = 139.52 kNm


Vuy = 87.1474 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 12.1 kNm
Vcy Permissible = 173.08 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 441.67 kN
Mux = 183.9 kNm
Vux = 113.3125 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 98.33 kNm
Vcx Permissible = 172.97 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 168 of 523

General Data
Column No. : C11
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 398
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 333.67 kN
Muxt = 5.46 kNm
Muyt = -210.25 kNm
Vuxt = -105.97 kN
Vuyt = -4.58 kN
Pub = 362.96 kN
Muxb = -10.57 kNm
Muyb = 160.57 kNm
Vuxb = -105.97 kN
Vuyb = -4.58 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 169 of 523

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = 5.46 kNm
M2 = -10.57 kNm
34 - 12 x (M1/M2) = 40.2
17.37 < 40.2, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = 160.57 kNm
M2 = -210.25 kNm
34 - 12 x (M1/M2) = 43.16

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 170 of 523

16.55 < 43.16, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 5.46 - 5.46
Major Axis Mux (bottom) -10.57 - -10.57
Minor Axis Muy (top) -210.25 - -210.25
Minor Axis Muy (bottom) 160.57 - 160.57

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 333.67 kN
Mux = 5.46 kNm
Muy = -210.25 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.51 deg
MRes = 210.32 kNm
MCap = 283.58 kNm
Capacity Ratio = MRes/ MCap
= 0.742 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 546.03 kN
Muy = 13.73 kNm
Vuy = -5.5615 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 92.07 kNm
Vcy Permissible = 382.15 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 171 of 523

Vuy < Vcy Permissible


Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 118.63 kN
Mux = 111.98 kNm
Vux = -75.4581 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 88.99 kNm
Vcx Permissible = 171.62 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C12
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 172 of 523

Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 107
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 129.64 kN
Muxt = -0.11 kNm
Muyt = -79.27 kNm
Vuxt = -166.39 kN
Vuyt = -1.3 kN
Pub = 136.85 kN
Muxb = -2.45 kNm
Muyb = 220.14 kNm
Vuxb = -166.39 kN
Vuyb = -1.3 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 173 of 523

Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
2400 x 350 x 6000 x 350 x
Top 265.195 185.312 74.125 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -0.11 kNm
M2 = -2.45 kNm
34 - 12 x (M1/M2) = 33.47
7.53 < 33.47, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = -79.27 kNm
M2 = 220.14 kNm
34 - 12 x (M1/M2) = 38.32
7.53 < 38.32, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -0.11 - -0.11
Major Axis Mux (bottom) -2.45 - -2.45
Minor Axis Muy (top) -79.27 - -79.27
Minor Axis Muy (bottom) 220.14 - 220.14

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 174 of 523

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 136.85 kN
Mux = -2.45 kNm
Muy = 220.14 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 89.36 deg
MRes = 220.16 kNm
MCap = 251.53 kNm
Capacity Ratio = MRes/ MCap
= 0.875 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 536.46 kN
Muy = 45.38 kNm
Vuy = 125.5165 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 58.56 kNm
Vcy Permissible = 380.85 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 2: EZ)
Nu = 1869.51 kN
Mux = 87.86 kNm
Vux = 173.2431 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 175 of 523

λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 274.36 kNm
Vcx Permissible = 532.26 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C12
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 176 of 523

Load Data
Analysis Reference No. = 154
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 199.87 kN
Muxt = 4.18 kNm
Muyt = -278.81 kNm
Vuxt = -162.68 kN
Vuyt = -2.8 kN
Pub = 213.89 kN
Muxb = -5.61 kNm
Muyb = 290.4 kNm
Vuxb = -162.68 kN
Vuyb = -2.8 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.548
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 177 of 523

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 4.18 kNm
M2 = -5.61 kNm
34 - 12 x (M1/M2) = 42.94
20.44 < 42.94, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -278.81 kNm
M2 = 290.4 kNm
34 - 12 x (M1/M2) = 45.52
20.44 < 45.52, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 4.18 - 4.18
Major Axis Mux (bottom) -5.61 - -5.61
Minor Axis Muy (top) -278.81 - -278.81
Minor Axis Muy (bottom) 290.4 - 290.4

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 213.89 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 178 of 523

Mux = -5.61 kNm


Muy = 290.4 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 88.89 deg
MRes = 290.45 kNm
MCap = 322.46 kNm
Capacity Ratio = MRes/ MCap
= 0.901 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 1027.41 kN
Muy = 200.27 kNm
Vuy = -121.5654 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 1.21 kNm
Vcy Permissible = 172.85 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 769.88 kN
Mux = 235.91 kNm
Vux = 144.9015 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 86.74 kNm
Vcx Permissible = 172.94 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 179 of 523

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C12
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 277
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 182.11 kN
Muxt = 6.21 kNm
Muyt = -253.44 kNm
Vuxt = -138.75 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 180 of 523

Vuyt = -3.49 kN
Pub = 196.14 kN
Muxb = -6 kNm
Muyb = 232.05 kNm
Vuxb = -138.75 kN
Vuyb = -3.49 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018

0.018< 0.05, Column shall be designed as non-sway frame

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 181 of 523

(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -6 kNm
M2 = 6.21 kNm
34 - 12 x (M1/M2) = 45.6
20.44 < 45.6, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 232.05 kNm
M2 = -253.44 kNm
34 - 12 x (M1/M2) = 44.99
20.44 < 44.99, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 6.21 - 6.21
Major Axis Mux (bottom) -6 - -6
Minor Axis Muy (top) -253.44 - -253.44
Minor Axis Muy (bottom) 232.05 - 232.05

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 182.11 kN
Mux = 6.21 kNm
Muy = -253.44 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 182 of 523

= 88.6 deg
MRes = 253.51 kNm
MCap = 259.85 kNm
Capacity Ratio = MRes/ MCap
= 0.976 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 652.34 kN
Muy = 141.47 kNm
Vuy = 89.1166 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 15.08 kNm
Vcy Permissible = 171.19 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 434.55 kN
Mux = 171.27 kNm
Vux = 105.6021 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 87.08 kNm
Vcx Permissible = 171.05 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm

Criterion for spacing of normal

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 183 of 523

links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C12
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 400
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 320.24 kN
Muxt = 10.48 kNm
Muyt = -211.04 kNm
Vuxt = -106.69 kN
Vuyt = -4.88 kN
Pub = 349.53 kN
Muxb = -6.6 kNm
Muyb = 162.29 kNm
Vuxb = -106.69 kN
Vuyb = -4.88 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 184 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 185 of 523

Kluy /r = 17.37
M1 = -6.6 kNm
M2 = 10.48 kNm
34 - 12 x (M1/M2) = 41.56
17.37 < 41.56, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = 162.29 kNm
M2 = -211.04 kNm
34 - 12 x (M1/M2) = 43.23
16.55 < 43.23, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 10.48 - 10.48
Major Axis Mux (bottom) -6.6 - -6.6
Minor Axis Muy (top) -211.04 - -211.04
Minor Axis Muy (bottom) 162.29 - 162.29

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 320.24 kN
Mux = 10.48 kNm
Muy = -211.04 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.16 deg
MRes = 211.3 kNm
MCap = 280.65 kNm
Capacity Ratio = MRes/ MCap
= 0.753 < 1

Design Of Shear

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 186 of 523

Design for shear along D


Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 526.88 kN
Muy = 8.23 kNm
Vuy = -6.0257 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 93.85 kNm
Vcy Permissible = 379.54 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 113.82 kN
Mux = 110.77 kNm
Vux = -74.2863 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 88.71 kNm
Vcx Permissible = 171.59 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 187 of 523

Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C13
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 109
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 135.42 kN
Muxt = -0.22 kNm
Muyt = -74.91 kNm
Vuxt = -156.38 kN
Vuyt = -1.22 kN
Pub = 142.64 kN
Muxb = -2.41 kNm
Muyb = 206.5 kNm
Vuxb = -156.38 kN
Vuyb = -1.22 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 188 of 523

N-M mm mm N-M N-M


Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
2400 x 350 x 6000 x 350 x
Top 265.195 185.312 74.125 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -0.22 kNm
M2 = -2.41 kNm
34 - 12 x (M1/M2) = 32.93
7.53 < 32.93, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 189 of 523

M1 = -74.91 kNm
M2 = 206.5 kNm
34 - 12 x (M1/M2) = 38.35
7.53 < 38.35, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -0.22 - -0.22
Major Axis Mux (bottom) -2.41 - -2.41
Minor Axis Muy (top) -74.91 - -74.91
Minor Axis Muy (bottom) 206.5 - 206.5

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 142.64 kN
Mux = -2.41 kNm
Muy = 206.5 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 89.33 deg
MRes = 206.51 kNm
MCap = 252.6 kNm
Capacity Ratio = MRes/ MCap
= 0.818 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 548.3 kN
Muy = 43.76 kNm
Vuy = -124.6701 kN
λ = 1
φ = 0.65
deff = 450 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 190 of 523

ρw = 0.006
mm = 62.48 kNm
Vcy Permissible = 382.46 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 2: EZ)
Nu = 994.8 kN
Mux = 70.65 kNm
Vux = -153.2614 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 122.1 kNm
Vcx Permissible = 438.84 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C13
Level : 1.8m To 5.3m

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 191 of 523

Design Code = ACI 318M - 2011


Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 156
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 195.4 kN
Muxt = 4.38 kNm
Muyt = -256.86 kNm
Vuxt = -150.79 kN
Vuyt = -2.87 kN
Pub = 209.43 kN
Muxb = -5.66 kNm
Muyb = 270.76 kNm
Vuxb = -150.79 kN
Vuyb = -2.87 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 192 of 523

Joint Column Beam Sizes Beam Stiffness Beta


Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.548
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 4.38 kNm
M2 = -5.66 kNm
34 - 12 x (M1/M2) = 43.28
20.44 < 43.28, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -256.86 kNm
M2 = 270.76 kNm
34 - 12 x (M1/M2) = 45.38
20.44 < 45.38, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 193 of 523

Major Axis Mux (top) 4.38 - 4.38


Major Axis Mux (bottom) -5.66 - -5.66
Minor Axis Muy (top) -256.86 - -256.86
Minor Axis Muy (bottom) 270.76 - 270.76

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 209.43 kN
Mux = -5.66 kNm
Muy = 270.76 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 88.8 deg
MRes = 270.82 kNm
MCap = 321.72 kNm
Capacity Ratio = MRes/ MCap
= 0.842 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 975.98 kN
Muy = 200.98 kNm
Vuy = -121.8528 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 11.89 kNm
Vcy Permissible = 172.84 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 194 of 523

[22] : 0.68 (LOAD 3: DL) -1.25


Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 733.38 kN
Mux = 224.22 kNm
Vux = 136.879 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 82.13 kNm
Vcx Permissible = 172.9 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C13
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 195 of 523

Clear Floor Height @ luy = 2950 mm


No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 279
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 189.64 kN
Muxt = 6.76 kNm
Muyt = -238.44 kNm
Vuxt = -129.84 kN
Vuyt = -3.77 kN
Pub = 203.67 kN
Muxb = -6.44 kNm
Muyb = 215.89 kNm
Vuxb = -129.84 kN
Vuyb = -3.77 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 196 of 523

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -6.44 kNm
M2 = 6.76 kNm
34 - 12 x (M1/M2) = 45.44
20.44 < 45.44, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 215.89 kNm
M2 = -238.44 kNm
34 - 12 x (M1/M2) = 44.86
20.44 < 44.86, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 6.76 - 6.76
Major Axis Mux (bottom) -6.44 - -6.44
Minor Axis Muy (top) -238.44 - -238.44
Minor Axis Muy (bottom) 215.89 - 215.89

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 197 of 523

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 189.64 kN
Mux = 6.76 kNm
Muy = -238.44 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.38 deg
MRes = 238.54 kNm
MCap = 261.06 kNm
Capacity Ratio = MRes/ MCap
= 0.914 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 659.47 kN
Muy = 140.84 kNm
Vuy = 88.635 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 13.06 kNm
Vcy Permissible = 171.18 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 430.56 kN
Mux = 164.54 kNm
Vux = 100.2712 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 198 of 523

mm = 81.12 kNm
Vcx Permissible = 170.98 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C13
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 402
Critical Analysis Load Combination : 16

Load Combination = [12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 199 of 523

(LOAD 2: EZ)
Critical Location = Top Joint
Put = 323.23 kN
Muxt = 9.78 kNm
Muyt = -209.83 kNm
Vuxt = -106.84 kN
Vuyt = -4.83 kN
Pub = 352.52 kN
Muxb = -7.13 kNm
Muyb = 164.01 kNm
Vuxb = -106.84 kN
Vuyb = -4.83 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 200 of 523

0.008< 0.05, Column shall be designed as non-sway frame


(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = -7.13 kNm
M2 = 9.78 kNm
34 - 12 x (M1/M2) = 42.75
17.37 < 42.75, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = 164.01 kNm
M2 = -209.83 kNm
34 - 12 x (M1/M2) = 43.38
16.55 < 43.38, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 9.78 - 9.78
Major Axis Mux (bottom) -7.13 - -7.13
Minor Axis Muy (top) -209.83 - -209.83
Minor Axis Muy (bottom) 164.01 - 164.01

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 323.23 kN
Mux = 9.78 kNm
Muy = -209.83 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 201 of 523

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.33 deg
MRes = 210.06 kNm
MCap = 281.2 kNm
Capacity Ratio = MRes/ MCap
= 0.747 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 529.28 kN
Muy = 8.81 kNm
Vuy = -5.8481 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 93.74 kNm
Vcy Permissible = 379.87 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 115.46 kN
Mux = 109.64 kNm
Vux = -72.9213 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 87.27 kNm
Vcx Permissible = 171.53 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 202 of 523

Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C14
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 111
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 175.14 kN
Muxt = -0.22 kNm
Muyt = -69.37 kNm
Vuxt = -145.44 kN
Vuyt = -1.22 kN
Pub = 182.35 kN
Muxb = -2.41 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 203 of 523

Muyb = 192.36 kNm


Vuxb = -145.44 kN
Vuyb = -1.22 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
2400 x 350 x 6000 x 350 x
Top 265.195 185.312 74.125 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 204 of 523

K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -0.22 kNm
M2 = -2.41 kNm
34 - 12 x (M1/M2) = 32.92
7.53 < 32.92, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = -69.37 kNm
M2 = 192.36 kNm
34 - 12 x (M1/M2) = 38.33
7.53 < 38.33, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -0.22 - -0.22
Major Axis Mux (bottom) -2.41 - -2.41
Minor Axis Muy (top) -69.37 - -69.37
Minor Axis Muy (bottom) 192.36 - 192.36

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 182.35 kN
Mux = -2.41 kNm
Muy = 192.36 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 89.28 deg
MRes = 192.37 kNm
MCap = 259.87 kNm
Capacity Ratio = MRes/ MCap
= 0.74 < 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 205 of 523

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 556.08 kN
Muy = 45.58 kNm
Vuy = 125.6776 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 62.16 kNm
Vcy Permissible = 383.51 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 931.44 kN
Mux = 70.72 kNm
Vux = 145.8099 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 109.75 kNm
Vcx Permissible = 431.29 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 206 of 523

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C14
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 158
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 229.67 kN
Muxt = 4.44 kNm
Muyt = -245.93 kNm
Vuxt = -143.42 kN
Vuyt = -2.89 kN
Pub = 243.7 kN
Muxb = -5.69 kNm
Muyb = 255.9 kNm
Vuxb = -143.42 kN
Vuyb = -2.89 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 207 of 523

Beam 1 Beam 2 Beam 1 Beam 2


(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.548
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 4.44 kNm
M2 = -5.69 kNm
34 - 12 x (M1/M2) = 43.36
20.44 < 43.36, Column not slender along D
Column Is Braced Along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 208 of 523

Slenderness Check along B


K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -245.93 kNm
M2 = 255.9 kNm
34 - 12 x (M1/M2) = 45.53
20.44 < 45.53, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 4.44 - 4.44
Major Axis Mux (bottom) -5.69 - -5.69
Minor Axis Muy (top) -245.93 - -245.93
Minor Axis Muy (bottom) 255.9 - 255.9

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 243.7 kN
Mux = -5.69 kNm
Muy = 255.9 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.73 deg
MRes = 255.96 kNm
MCap = 269.99 kNm
Capacity Ratio = MRes/ MCap
= 0.948 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 1005.89 kN
Muy = 201.06 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 209 of 523

Vuy = -121.8849 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 6.17 kNm
Vcy Permissible = 170.95 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 735.53 kN
Mux = 201.51 kNm
Vux = 124.3426 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 59 kNm
Vcx Permissible = 171.06 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 210 of 523

General Data
Column No. : C14
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 281
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 192 kN
Muxt = 6.7 kNm
Muyt = -227.72 kNm
Vuxt = -125.24 kN
Vuyt = -3.76 kN
Pub = 206.02 kN
Muxb = -6.46 kNm
Muyb = 210.51 kNm
Vuxb = -125.24 kN
Vuyb = -3.76 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 211 of 523

Effective Length Factor along Major


= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -6.46 kNm
M2 = 6.7 kNm
34 - 12 x (M1/M2) = 45.57
20.44 < 45.57, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 210.51 kNm
M2 = -227.72 kNm
34 - 12 x (M1/M2) = 45.09
20.44 < 45.09, Column not slender along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 212 of 523

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 6.7 - 6.7
Major Axis Mux (bottom) -6.46 - -6.46
Minor Axis Muy (top) -227.72 - -227.72
Minor Axis Muy (bottom) 210.51 - 210.51

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 192 kN
Mux = 6.7 kNm
Muy = -227.72 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.32 deg
MRes = 227.82 kNm
MCap = 261.43 kNm
Capacity Ratio = MRes/ MCap
= 0.871 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 655.92 kN
Muy = 140.77 kNm
Vuy = 88.6476 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 13.69 kNm
Vcy Permissible = 171.18 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 213 of 523

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 421.4 kN
Mux = 147.02 kNm
Vux = 90.6363 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 65.37 kNm
Vcx Permissible = 171.05 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C14
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 214 of 523

Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 404
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 321.41 kN
Muxt = 10.6 kNm
Muyt = -209.28 kNm
Vuxt = -106.73 kN
Vuyt = -5.12 kN
Pub = 350.69 kN
Muxb = -7.33 kNm
Muyb = 164.18 kNm
Vuxb = -106.73 kN
Vuyb = -5.12 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 215 of 523

N-M mm mm N-M N-M


2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = -7.33 kNm
M2 = 10.6 kNm
34 - 12 x (M1/M2) = 42.29
17.37 < 42.29, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = 164.18 kNm
M2 = -209.28 kNm
34 - 12 x (M1/M2) = 43.41
16.55 < 43.41, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 10.6 - 10.6
Major Axis Mux (bottom) -7.33 - -7.33
Minor Axis Muy (top) -209.28 - -209.28
Minor Axis Muy (bottom) 164.18 - 164.18

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 216 of 523

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 321.41 kN
Mux = 10.6 kNm
Muy = -209.28 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.1 deg
MRes = 209.55 kNm
MCap = 280.8 kNm
Capacity Ratio = MRes/ MCap
= 0.746 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 526.79 kN
Muy = 8.94 kNm
Vuy = -6.1558 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 93.13 kNm
Vcy Permissible = 379.53 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 114.95 kN
Mux = 107.78 kNm
Vux = -71.441 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 217 of 523

λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 85.51 kNm
Vcx Permissible = 171.51 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C15
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 218 of 523

Load Data
Analysis Reference No. = 113
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 186.92 kN
Muxt = 0.03 kNm
Muyt = -64.31 kNm
Vuxt = -134.88 kN
Vuyt = -1.41 kN
Pub = 194.14 kN
Muxb = -2.51 kNm
Muyb = 178.42 kNm
Vuxb = -134.88 kN
Vuyb = -1.41 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
2400 x 350 x 6000 x 350 x
Top 265.195 185.312 74.125 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 219 of 523

Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 0.03 kNm
M2 = -2.51 kNm
34 - 12 x (M1/M2) = 34.14
7.53 < 34.14, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = -64.31 kNm
M2 = 178.42 kNm
34 - 12 x (M1/M2) = 38.33
7.53 < 38.33, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 0.03 - 0.03
Major Axis Mux (bottom) -2.51 - -2.51
Minor Axis Muy (top) -64.31 - -64.31
Minor Axis Muy (bottom) 178.42 - 178.42

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 194.14 kN
Mux = -2.51 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 220 of 523

Muy = 178.42 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 89.19 deg
MRes = 178.44 kNm
MCap = 261.9 kNm
Capacity Ratio = MRes/ MCap
= 0.681 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 554.97 kN
Muy = 45.36 kNm
Vuy = 125.4999 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 62.17 kNm
Vcy Permissible = 383.36 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 775.28 kN
Mux = 63.95 kNm
Vux = -135.19 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 86.26 kNm
Vcx Permissible = 412.09 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 221 of 523

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C15
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 160
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 228.57 kN
Muxt = 4.13 kNm
Muyt = -224.22 kNm
Vuxt = -131.55 kN
Vuyt = -2.8 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 222 of 523

Pub = 242.59 kN
Muxb = -5.65 kNm
Muyb = 236.07 kNm
Vuxb = -131.55 kN
Vuyb = -2.8 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.548
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 223 of 523

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 4.13 kNm
M2 = -5.65 kNm
34 - 12 x (M1/M2) = 42.77
20.44 < 42.77, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -224.22 kNm
M2 = 236.07 kNm
34 - 12 x (M1/M2) = 45.4
20.44 < 45.4, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 4.13 - 4.13
Major Axis Mux (bottom) -5.65 - -5.65
Minor Axis Muy (top) -224.22 - -224.22
Minor Axis Muy (bottom) 236.07 - 236.07

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 242.59 kN
Mux = -5.65 kNm
Muy = 236.07 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.63 deg

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 224 of 523

MRes = 236.14 kNm


MCap = 269.72 kNm
Capacity Ratio = MRes/ MCap
= 0.875 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 964.24 kN
Muy = 200.74 kNm
Vuy = -121.8289 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 13.92 kNm
Vcy Permissible = 170.96 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 704.14 kN
Mux = 189.58 kNm
Vux = 116.3119 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 53.16 kNm
Vcx Permissible = 171.02 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 225 of 523

Min. Longitudinal Bar dia X 16 = 256 mm


48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C15
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 283
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 203.82 kN
Muxt = 6.78 kNm
Muyt = -212.14 kNm
Vuxt = -116.18 kN
Vuyt = -3.71 kN
Pub = 217.85 kN
Muxb = -6.21 kNm
Muyb = 194.39 kNm
Vuxb = -116.18 kN
Vuyb = -3.71 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 226 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -6.21 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 227 of 523

M2 = 6.78 kNm
34 - 12 x (M1/M2) = 44.99
20.44 < 44.99, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 194.39 kNm
M2 = -212.14 kNm
34 - 12 x (M1/M2) = 45
20.44 < 45, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 6.78 - 6.78
Major Axis Mux (bottom) -6.21 - -6.21
Minor Axis Muy (top) -212.14 - -212.14
Minor Axis Muy (bottom) 194.39 - 194.39

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 203.82 kN
Mux = 6.78 kNm
Muy = -212.14 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.17 deg
MRes = 212.25 kNm
MCap = 263.26 kNm
Capacity Ratio = MRes/ MCap
= 0.806 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 228 of 523

[15] : 1.42 (LOAD 3: DL) +1.25


Critical Load Combination = kN
(LOAD 1: EX)
Nu = 673.41 kN
Muy = 141.15 kNm
Vuy = 88.6697 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 10.68 kNm
Vcy Permissible = 171.17 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 423 kN
Mux = 140.25 kNm
Vux = 85.4666 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 58.29 kNm
Vcx Permissible = 170.98 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 229 of 523

Spacing 250 --- --- 250 ---

General Data
Column No. : C15
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 406
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 316.59 kN
Muxt = 6.77 kNm
Muyt = -208.47 kNm
Vuxt = -106.7 kN
Vuyt = -3.67 kN
Pub = 345.88 kN
Muxb = -6.08 kNm
Muyb = 164.87 kNm
Vuxb = -106.7 kN
Vuyb = -3.67 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 230 of 523

Bottom 136.386 550 550 88.95 88.95 1.534


5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = -6.08 kNm
M2 = 6.77 kNm
34 - 12 x (M1/M2) = 44.77
17.37 < 44.77, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = 164.87 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 231 of 523

M2 = -208.47 kNm
34 - 12 x (M1/M2) = 43.49
16.55 < 43.49, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 6.77 - 6.77
Major Axis Mux (bottom) -6.08 - -6.08
Minor Axis Muy (top) -208.47 - -208.47
Minor Axis Muy (bottom) 164.87 - 164.87

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 316.59 kN
Mux = 6.77 kNm
Muy = -208.47 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.14 deg
MRes = 208.58 kNm
MCap = 280.65 kNm
Capacity Ratio = MRes/ MCap
= 0.743 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 519.75 kN
Muy = 7.76 kNm
Vuy = -4.5786 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 232 of 523

mm = 92.94 kNm
Vcy Permissible = 378.57 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 113.26 kN
Mux = 106.09 kNm
Vux = -69.9476 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 84.15 kNm
Vcx Permissible = 171.48 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C16
Level : 0m To 1.8m
Design Code = ACI 318M - 2011

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 233 of 523

Grade Of Concrete = C21 N/sqmm


Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 115
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Bottom Joint
Put = 1349.2 kN
Muxt = -57.05 kNm
Muyt = 8.96 kNm
Vuxt = 11.73 kN
Vuyt = 134.39 kN
Pub = 1364.26 kN
Muxb = 184.79 kNm
Muyb = -12.14 kNm
Vuxb = 11.73 kN
Vuyb = 134.39 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 234 of 523

Stiffness Beam 1 Beam 2 Beam 1 Beam 2


(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
2400 x 350 x 6000 x 350 x
Top 265.195 185.312 74.125 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -57.05 kNm
M2 = 184.79 kNm
34 - 12 x (M1/M2) = 37.7
7.53 < 37.7, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 8.96 kNm
M2 = -12.14 kNm
34 - 12 x (M1/M2) = 42.85
7.53 < 42.85, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -57.05 - -57.05
Major Axis Mux (bottom) 184.79 - 184.79

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 235 of 523

Minor Axis Muy (top) 8.96 - 8.96


Minor Axis Muy (bottom) -12.14 - -12.14

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1364.26 kN
Mux = 184.79 kNm
Muy = -12.14 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 3.76 deg
MRes = 185.19 kNm
MCap = 291.45 kNm
Capacity Ratio = MRes/ MCap
= 0.635 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 537.49 kN
Muy = 49.65 kNm
Vuy = 128.8925 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 54.49 kNm
Vcy Permissible = 380.99 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 236 of 523

Nu = 180.79 kN
Mux = 58.78 kNm
Vux = -123.9568 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 23.75 kNm
Vcx Permissible = 185.77 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C16
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 237 of 523

No Of Columns In Group = 1

Load Data
Analysis Reference No. = 162
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 229.67 kN
Muxt = 2.83 kNm
Muyt = -204.7 kNm
Vuxt = -120.55 kN
Vuyt = -1.7 kN
Pub = 243.69 kN
Muxb = -3.11 kNm
Muyb = 217.1 kNm
Vuxb = -120.55 kN
Vuyb = -1.7 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.548
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 238 of 523

Effective Length Factor along Minor


= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 2.83 kNm
M2 = -3.11 kNm
34 - 12 x (M1/M2) = 44.92
20.44 < 44.92, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -204.7 kNm
M2 = 217.1 kNm
34 - 12 x (M1/M2) = 45.32
20.44 < 45.32, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 2.83 - 2.83
Major Axis Mux (bottom) -3.11 - -3.11
Minor Axis Muy (top) -204.7 - -204.7
Minor Axis Muy (bottom) 217.1 - 217.1

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 239 of 523

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 243.69 kN
Mux = -3.11 kNm
Muy = 217.1 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 89.18 deg
MRes = 217.12 kNm
MCap = 270.41 kNm
Capacity Ratio = MRes/ MCap
= 0.803 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 881.18 kN
Muy = 191.56 kNm
Vuy = -116.3598 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 20.83 kNm
Vcy Permissible = 170.96 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 645.19 kN
Mux = 172.56 kNm
Vux = 106.0079 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 47.55 kNm
Vcx Permissible = 171.03 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 240 of 523

Vux < Vcx Permissible


Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C16
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 285
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 202.15 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 241 of 523

Muxt = 4.57 kNm


Muyt = -196.6 kNm
Vuxt = -107.65 kN
Vuyt = -2.75 kN
Pub = 216.18 kN
Muxb = -5.07 kNm
Muyb = 180.08 kNm
Vuxb = -107.65 kN
Vuyb = -2.75 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 242 of 523

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 4.57 kNm
M2 = -5.07 kNm
34 - 12 x (M1/M2) = 44.82
20.44 < 44.82, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 180.08 kNm
M2 = -196.6 kNm
34 - 12 x (M1/M2) = 44.99
20.44 < 44.99, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 4.57 - 4.57
Major Axis Mux (bottom) -5.07 - -5.07
Minor Axis Muy (top) -196.6 - -196.6
Minor Axis Muy (bottom) 180.08 - 180.08

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 202.15 kN
Mux = 4.57 kNm
Muy = -196.6 kNm

Moment Capacity Check


Pt Calculated = 1.15

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 243 of 523

Reinforcement Provided = 4-#20 + 8-#16


Load Angle = Tan-1(Muy/Mux)
= 88.67 deg
MRes = 196.65 kNm
MCap = 263.13 kNm
Capacity Ratio = MRes/ MCap
= 0.747 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 651.88 kN
Muy = 147.6 kNm
Vuy = 93.1523 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 21.3 kNm
Vcy Permissible = 171.2 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 392.33 kN
Mux = 128.31 kNm
Vux = 77.9741 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 52.3 kNm
Vcx Permissible = 170.97 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 244 of 523

= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C16
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 408
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 325.89 kN
Muxt = 21.01 kNm
Muyt = -195.65 kNm
Vuxt = -101.11 kN
Vuyt = -8.24 kN
Pub = 355.18 kN
Muxb = -7.81 kNm
Muyb = 158.15 kNm
Vuxb = -101.11 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 245 of 523

Vuyb = -8.24 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 246 of 523

K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = -7.81 kNm
M2 = 21.01 kNm
34 - 12 x (M1/M2) = 38.46
17.37 < 38.46, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = 158.15 kNm
M2 = -195.65 kNm
34 - 12 x (M1/M2) = 43.7
16.55 < 43.7, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 21.01 - 21.01
Major Axis Mux (bottom) -7.81 - -7.81
Minor Axis Muy (top) -195.65 - -195.65
Minor Axis Muy (bottom) 158.15 - 158.15

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 325.89 kN
Mux = 21.01 kNm
Muy = -195.65 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 83.87 deg
MRes = 196.77 kNm
MCap = 280.52 kNm
Capacity Ratio = MRes/ MCap
= 0.701 < 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 247 of 523

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 524.2 kN
Muy = 9.98 kNm
Vuy = -9.9538 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 91.59 kNm
Vcy Permissible = 379.18 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 119.84 kN
Mux = 101.33 kNm
Vux = -66.24 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 78.12 kNm
Vcx Permissible = 171.42 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 248 of 523

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C17
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 116
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Bottom Joint
Put = 1344.02 kN
Muxt = 56.69 kNm
Muyt = 16.93 kNm
Vuxt = 1.94 kN
Vuyt = -135.27 kN
Pub = 1359.08 kN
Muxb = -186.73 kNm
Muyb = 13.43 kNm
Vuxb = 1.94 kN
Vuyb = -135.27 kN

Effective Length Calculation


Calculation Along Major Axis Of Column

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 249 of 523

Joint Column Beam Sizes Beam Stiffness Beta


Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
2400 x 350 x 6000 x 350 x
Top 265.195 185.312 74.125 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 56.69 kNm
M2 = -186.73 kNm
34 - 12 x (M1/M2) = 37.64
7.53 < 37.64, Column not slender along D
Column Is Braced Along B
Slenderness Check along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 250 of 523

K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 13.43 kNm
M2 = 16.93 kNm
34 - 12 x (M1/M2) = 24.48
7.53 < 24.48, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 56.69 - 56.69
Major Axis Mux (bottom) -186.73 - -186.73
Minor Axis Muy (top) 16.93 - 16.93
Minor Axis Muy (bottom) 13.43 - 13.43

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1359.08 kN
Mux = -186.73 kNm
Muy = 13.43 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 4.12 deg
MRes = 187.21 kNm
MCap = 291.76 kNm
Capacity Ratio = MRes/ MCap
= 0.642 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 532.75 kN
Muy = 57.5 kNm
Vuy = -135.5443 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 251 of 523

λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 45.73 kNm
Vcy Permissible = 380.35 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 467.14 kN
Mux = 134 kNm
Vux = 87.2478 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 43.49 kNm
Vcx Permissible = 171.39 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 252 of 523

General Data
Column No. : C17
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 163
Critical Analysis Load Combination : 23
Load Combination = [19] : 0.68 (LOAD 3: DL) +1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 409.68 kN
Muxt = -217.28 kNm
Muyt = 30.81 kNm
Vuxt = 16.63 kN
Vuyt = 128.63 kN
Pub = 423.7 kN
Muxb = 232.79 kNm
Muyb = -27.38 kNm
Vuxb = 16.63 kN
Vuyb = 128.63 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 253 of 523

Effective Length Factor along Major


= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.548
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -217.28 kNm
M2 = 232.79 kNm
34 - 12 x (M1/M2) = 45.2
20.44 < 45.2, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -27.38 kNm
M2 = 30.81 kNm
34 - 12 x (M1/M2) = 44.66
20.44 < 44.66, Column not slender along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 254 of 523

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -217.28 - -217.28
Major Axis Mux (bottom) 232.79 - 232.79
Minor Axis Muy (top) 30.81 - 30.81
Minor Axis Muy (bottom) -27.38 - -27.38

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 423.7 kN
Mux = 232.79 kNm
Muy = -27.38 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 6.71 deg
MRes = 234.39 kNm
MCap = 294.18 kNm
Capacity Ratio = MRes/ MCap
= 0.797 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 940.47 kN
Muy = 209.99 kNm
Vuy = -127.4609 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 27.78 kNm
Vcy Permissible = 170.96 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 255 of 523

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 462.05 kN
Mux = 109.07 kNm
Vux = -71.3989 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 19.54 kNm
Vcx Permissible = 171.43 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C17
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 256 of 523

Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 286
Critical Analysis Load Combination : 23
Load Combination = [19] : 0.68 (LOAD 3: DL) +1.25 (LOAD 1: EX)
Critical Location = Top Joint
Put = 285.86 kN
Muxt = -193.64 kNm
Muyt = 24.64 kNm
Vuxt = 14.26 kN
Vuyt = 103.55 kN
Pub = 299.88 kN
Muxb = 168.68 kNm
Muyb = -25.26 kNm
Vuxb = 14.26 kN
Vuyb = 103.55 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 257 of 523

2400 x 350 x 6000 x 350 x


Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 168.68 kNm
M2 = -193.64 kNm
34 - 12 x (M1/M2) = 44.45
20.44 < 44.45, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 24.64 kNm
M2 = -25.26 kNm
34 - 12 x (M1/M2) = 45.71
20.44 < 45.71, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -193.64 - -193.64
Major Axis Mux (bottom) 168.68 - 168.68
Minor Axis Muy (top) 24.64 - 24.64
Minor Axis Muy (bottom) -25.26 - -25.26

Where

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 258 of 523

A = Moments from analysis


B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 285.86 kN
Mux = -193.64 kNm
Muy = 24.64 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 7.25 deg
MRes = 195.21 kNm
MCap = 274.1 kNm
Capacity Ratio = MRes/ MCap
= 0.712 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 660.21 kN
Muy = 163.74 kNm
Vuy = -100.5233 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 35.82 kNm
Vcy Permissible = 171.03 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 299.34 kN
Mux = 115.66 kNm
Vux = 70.7762 kN
λ = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 259 of 523

φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 57.66 kNm
Vcx Permissible = 171.01 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C17
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 260 of 523

Analysis Reference No. = 409


Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 448.17 kN
Muxt = -20.17 kNm
Muyt = 242.68 kNm
Vuxt = 104.93 kN
Vuyt = 10.82 kN
Pub = 477.46 kN
Muxb = 17.69 kNm
Muyb = -124.49 kNm
Vuxb = 104.93 kN
Vuyb = 10.82 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 261 of 523

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = 17.69 kNm
M2 = -20.17 kNm
34 - 12 x (M1/M2) = 44.53
17.37 < 44.53, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = -124.49 kNm
M2 = 242.68 kNm
34 - 12 x (M1/M2) = 40.16
16.55 < 40.16, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -20.17 - -20.17
Major Axis Mux (bottom) 17.69 - 17.69
Minor Axis Muy (top) 242.68 - 242.68
Minor Axis Muy (bottom) -124.49 - -124.49

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 448.17 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 262 of 523

Mux = -20.17 kNm


Muy = 242.68 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 85.25 deg
MRes = 243.52 kNm
MCap = 298.54 kNm
Capacity Ratio = MRes/ MCap
= 0.816 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 362.42 kN
Muy = 82.77 kNm
Vuy = 57.9463 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 12.55 kNm
Vcy Permissible = 171.88 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 2: EZ)
Nu = 477.46 kN
Mux = 124.49 kNm
Vux = 104.9333 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 31.98 kNm
Vcx Permissible = 173.29 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 263 of 523

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C18
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 98
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = -2.28 kN
Muxt = -16.07 kNm
Muyt = -17.45 kNm
Vuxt = -27.06 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 264 of 523

Vuyt = -77.32 kN
Pub = 4.93 kN
Muxb = -155.2 kNm
Muyb = 31.24 kNm
Vuxb = -27.06 kN
Vuyb = -77.32 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x
Top 265.195 No Beam - 88.95 4.517
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
2400 x 350 x 6000 x 350 x
Top 265.195 185.312 74.125 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 265 of 523

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 0 kNm
M2 = 0 kNm
34 - 12 x (M1/M2) = 0
7.53 > 0,Column slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 0 kNm
M2 = 0 kNm
34 - 12 x (M1/M2) = 0
7.53 > 0, Column slender along B
Moment Magnification:

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -16.07 - -16.07
Major Axis Mux (bottom) -155.2 - -155.2
Minor Axis Muy (top) -17.45 - -17.45
Minor Axis Muy (bottom) 31.24 - 31.24

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 4.93 kN
Mux = -155.2 kNm
Muy = 31.24 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 11.38 deg

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 266 of 523

MRes = 158.32 kNm


MCap = 226.76 kNm
Capacity Ratio = MRes/ MCap
= 0.698 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 2.28 kN
Muy = 16.07 kNm
Vuy = -77.3183 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 15.62 kNm
Vcy Permissible = 212.44 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 26.56 kN
Mux = 56.19 kNm
Vux = -108.8004 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 51.04 kNm
Vcx Permissible = 184.07 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 267 of 523

Min. Longitudinal Bar dia X 16 = 256 mm


48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C18
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 144
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = -2.29 kN
Muxt = -8.79 kNm
Muyt = -163.89 kNm
Vuxt = -98.85 kN
Vuyt = 3.27 kN
Pub = 11.74 kN
Muxb = 2.67 kNm
Muyb = 181.99 kNm
Vuxb = -98.85 kN
Vuyb = 3.27 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 268 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x
Bottom 136.386 No Beam - 88.95 4.517
550
5000 x 350 x
Top 136.386 No Beam - 88.95 3.068
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.548
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 0 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 269 of 523

M2 = 0 kNm
34 - 12 x (M1/M2) = 0
20.44 > 0,Column slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 0 kNm
M2 = 0 kNm
34 - 12 x (M1/M2) = 0
20.44 > 0, Column slender along B
Moment Magnification:

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -8.79 - -8.79
Major Axis Mux (bottom) 2.67 - 2.67
Minor Axis Muy (top) -163.89 - -163.89
Minor Axis Muy (bottom) 181.99 - 181.99

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 11.74 kN
Mux = 2.67 kNm
Muy = 181.99 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 89.16 deg
MRes = 182.01 kNm
MCap = 228.26 kNm
Capacity Ratio = MRes/ MCap
= 0.797 < 1

Design Of Shear
Design for shear along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 270 of 523

Critical Analysis Load Combination : 17


[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 236.35 kN
Muy = 101.38 kNm
Vuy = -72.2551 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 55.59 kNm
Vcy Permissible = 172 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 2: EZ)
Nu = 227.39 kN
Mux = 173.58 kNm
Vux = -105.1212 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 129.53 kNm
Vcx Permissible = 170.95 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 271 of 523

Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C18
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 267
Critical Analysis Load Combination : 24
Load Combination = [20] : 0.68 (LOAD 3: DL) +1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 26.78 kN
Muxt = -7.24 kNm
Muyt = -153.41 kNm
Vuxt = -84.57 kN
Vuyt = 4.77 kN
Pub = 40.81 kN
Muxb = 9.44 kNm
Muyb = 142.51 kNm
Vuxb = -84.57 kN
Vuyb = 4.77 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 272 of 523

5000 x 350 x
Bottom 136.386 No Beam - 88.95 3.068
550
5000 x 350 x
Top 136.386 No Beam - 88.95 3.068
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -7.24 kNm
M2 = 9.44 kNm
34 - 12 x (M1/M2) = 43.2
20.44 < 43.2, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 273 of 523

M1 = 142.51 kNm
M2 = -153.41 kNm
34 - 12 x (M1/M2) = 45.15
20.44 < 45.15, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -7.24 - -7.24
Major Axis Mux (bottom) 9.44 - 9.44
Minor Axis Muy (top) -153.41 - -153.41
Minor Axis Muy (bottom) 142.51 - 142.51

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 26.78 kN
Mux = -7.24 kNm
Muy = -153.41 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.3 deg
MRes = 153.58 kNm
MCap = 231.06 kNm
Capacity Ratio = MRes/ MCap
= 0.665 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 197.95 kN
Muy = 83.01 kNm
Vuy = 58.6766 kN
λ = 1
φ = 0.65
deff = 450 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 274 of 523

ρw = 0.006
mm = 44.66 kNm
Vcy Permissible = 171.94 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 2: EZ)
Nu = 352.81 kN
Mux = 105.99 kNm
Vux = 65.4108 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 37.63 kNm
Vcx Permissible = 171.06 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C18
Level : 8.8m To 12.3m

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 275 of 523

Design Code = ACI 318M - 2011


Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 390
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 54.51 kN
Muxt = -56.83 kNm
Muyt = -106.19 kNm
Vuxt = -55.78 kN
Vuyt = 27.43 kN
Pub = 83.8 kN
Muxb = 39.13 kNm
Muyb = 88.98 kNm
Vuxb = -55.78 kN
Vuyb = 27.43 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x
Bottom 136.386 No Beam - 88.95 3.068
550
5000 x 350 x
Top 136.386 No Beam - 88.95 1.534
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 276 of 523

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
2400 x 350 x 6000 x 350 x
Bottom 136.386 185.312 74.125 1.052
550 550
2400 x 350 x 6000 x 350 x
Top 136.386 185.312 74.125 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 39.13 kNm
M2 = -56.83 kNm
34 - 12 x (M1/M2) = 42.26
20.44 < 42.26, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = 88.98 kNm
M2 = -106.19 kNm
34 - 12 x (M1/M2) = 44.06
16.55 < 44.06, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 277 of 523

A B C
Major Axis Mux (top) -56.83 - -56.83
Major Axis Mux (bottom) 39.13 - 39.13
Minor Axis Muy (top) -106.19 - -106.19
Minor Axis Muy (bottom) 88.98 - 88.98

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 54.51 kN
Mux = -56.83 kNm
Muy = -106.19 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 61.84 deg
MRes = 120.44 kNm
MCap = 239.05 kNm
Capacity Ratio = MRes/ MCap
= 0.504 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 68.31 kN
Muy = 10.47 kNm
Vuy = -2.3367 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 2.76 kNm
Vcy Permissible = 310.63 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 16

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 278 of 523

[12] : 1.42 (LOAD 3: DL) +0.5


Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 2: EZ)
Nu = 83.8 kN
Mux = 88.98 kNm
Vux = -55.7755 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 72.74 kNm
Vcx Permissible = 171.16 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C19
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 279 of 523

Clear Floor Height @ luy = 1250 mm


No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 102
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 49.28 kN
Muxt = 12.97 kNm
Muyt = 98.63 kNm
Vuxt = 195.63 kN
Vuyt = -12.64 kN
Pub = 56.49 kN
Muxb = -9.78 kNm
Muyb = -253.41 kNm
Vuxb = 195.63 kN
Vuyb = -12.64 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x
Top 265.195 No Beam 88.95 - 4.517
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x 2400 x 350 x
Top 265.195 74.125 185.312 1.548
550 550

Sway Condition (as per Stability

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 280 of 523

Index) = Non Sway


Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -9.78 kNm
M2 = 12.97 kNm
34 - 12 x (M1/M2) = 43.05
7.53 < 43.05, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 98.63 kNm
M2 = -253.41 kNm
34 - 12 x (M1/M2) = 38.67
7.53 < 38.67, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 12.97 - 12.97
Major Axis Mux (bottom) -9.78 - -9.78
Minor Axis Muy (top) 98.63 - 98.63
Minor Axis Muy (bottom) -253.41 - -253.41

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 281 of 523

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 56.49 kN
Mux = -9.78 kNm
Muy = -253.41 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 87.79 deg
MRes = 253.6 kNm
MCap = 297.98 kNm
Capacity Ratio = MRes/ MCap
= 0.851 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 686.26 kN
Muy = 165.43 kNm
Vuy = -92.92 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 32.46 kNm
Vcy Permissible = 172.26 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 2: EZ)
Nu = 1762.25 kN
Mux = 242.92 kNm
Vux = -179.2022 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 98.51 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 282 of 523

Vcx Permissible = 521.71 kN


Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C19
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 149
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 283 of 523

Put = 135.78 kN
Muxt = -8.2 kNm
Muyt = 318.37 kNm
Vuxt = 186.32 kN
Vuyt = 0.48 kN
Pub = 149.81 kN
Muxb = -6.53 kNm
Muyb = -333.57 kNm
Vuxb = 186.32 kN
Vuyb = 0.48 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x
Bottom 136.386 No Beam 88.95 - 4.517
550
5000 x 350 x 2250 x 350 x
Top 136.386 88.95 197.666 0.952
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.86
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.548
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 284 of 523

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.86
r = 144.34 mm
Kluy /r = 17.58
M1 = -6.53 kNm
M2 = -8.2 kNm
34 - 12 x (M1/M2) = 24.44
17.58 < 24.44, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 318.37 kNm
M2 = -333.57 kNm
34 - 12 x (M1/M2) = 45.45
20.44 < 45.45, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -8.2 - -8.2
Major Axis Mux (bottom) -6.53 - -6.53
Minor Axis Muy (top) 318.37 - 318.37
Minor Axis Muy (bottom) -333.57 - -333.57

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 149.81 kN
Mux = -6.53 kNm
Muy = -333.57 kNm

Moment Capacity Check

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 285 of 523

Pt Calculated = 1.79
Reinforcement Provided = 4-#25 + 8-#20
Load Angle = Tan-1(Muy/Mux)
= 88.88 deg
MRes = 333.63 kNm
MCap = 362.4 kNm
Capacity Ratio = MRes/ MCap
= 0.921 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 559.19 kN
Muy = 119.63 kNm
Vuy = -82.1219 kN
λ = 1
φ = 0.65
deff = 447.5 mm
ρw = 0.009
mm = 11.11 kNm
Vcy Permissible = 174.52 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 1201.55 kN
Mux = 252.66 kNm
Vux = -155.1935 kN
λ = 1
φ = 0.65
deff = 447.5 mm
ρw = 0.009
mm = 19.49 kNm
Vcx Permissible = 173.42 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 286 of 523

> Max. longitudinal bar dia / 4


= 6.25 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C19
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 272
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 537.34 kN
Muxt = -56.19 kNm
Muyt = 328.22 kNm
Vuxt = 181.29 kN
Vuyt = 30.39 kN
Pub = 566.63 kN
Muxb = 50.15 kNm
Muyb = -306.11 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 287 of 523

Vuxb = 181.29 kN
Vuyb = 30.39 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 2250 x 350 x
Bottom 136.386 88.95 197.666 0.952
550 550
5000 x 350 x 2250 x 350 x
Top 136.386 88.95 197.666 0.952
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.77
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 288 of 523

Slenderness Check along D


K = 0.77
r = 144.34 mm
Kluy /r = 15.74
M1 = 50.15 kNm
M2 = -56.19 kNm
34 - 12 x (M1/M2) = 44.71
15.74 < 44.71, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -306.11 kNm
M2 = 328.22 kNm
34 - 12 x (M1/M2) = 45.19
20.44 < 45.19, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -56.19 - -56.19
Major Axis Mux (bottom) 50.15 - 50.15
Minor Axis Muy (top) 328.22 - 328.22
Minor Axis Muy (bottom) -306.11 - -306.11

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 537.34 kN
Mux = -56.19 kNm
Muy = 328.22 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 80.29 deg
MRes = 333 kNm
MCap = 352.5 kNm
Capacity Ratio = MRes/ MCap

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 289 of 523

= 0.945 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 202.75 kN
Muy = 97.74 kNm
Vuy = 68.0488 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 58.46 kNm
Vcy Permissible = 174.01 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 2: EZ)
Nu = 812.24 kN
Mux = 159.49 kNm
Vux = -100.4151 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 2.12 kNm
Vcx Permissible = 173.14 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 290 of 523

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C19
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 395
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 153 kN
Muxt = 58.48 kNm
Muyt = 191.11 kNm
Vuxt = 99.41 kN
Vuyt = -14.04 kN
Pub = 182.29 kN
Muxb = 9.34 kNm
Muyb = -156.72 kNm
Vuxb = 99.41 kN
Vuyb = -14.04 kN

Effective Length Calculation

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 291 of 523

Calculation Along Major Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 2250 x 350 x
Bottom 136.386 88.95 197.666 0.952
550 550
5000 x 350 x
Top 136.386 No Beam 88.95 - 1.534
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.86
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.86
r = 144.34 mm
Kluy /r = 17.58
M1 = 9.34 kNm
M2 = 58.48 kNm
34 - 12 x (M1/M2) = 32.08

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 292 of 523

17.58 < 32.08, Column not slender along D


Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = -156.72 kNm
M2 = 191.11 kNm
34 - 12 x (M1/M2) = 43.84
16.55 < 43.84, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 58.48 - 58.48
Major Axis Mux (bottom) 9.34 - 9.34
Minor Axis Muy (top) 191.11 - 191.11
Minor Axis Muy (bottom) -156.72 - -156.72

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 153 kN
Mux = 58.48 kNm
Muy = 191.11 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 72.99 deg
MRes = 199.86 kNm
MCap = 252.28 kNm
Capacity Ratio = MRes/ MCap
= 0.792 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 293 of 523

Nu = 274.59 kN
Muy = 5.28 kNm
Vuy = -23.6027 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 47.93 kNm
Vcy Permissible = 343.35 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 55.29 kN
Mux = 115.86 kNm
Vux = 76.3697 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 105.15 kNm
Vcx Permissible = 171.47 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 294 of 523

General Data
Column No. : C20
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 104
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 121.1 kN
Muxt = -0.99 kNm
Muyt = 93.12 kNm
Vuxt = 184.34 kN
Vuyt = -1.59 kN
Pub = 128.31 kN
Muxb = -3.86 kNm
Muyb = -238.6 kNm
Vuxb = 184.34 kN
Vuyb = -1.59 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 295 of 523

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x 2400 x 350 x
Top 265.195 74.125 185.312 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -0.99 kNm
M2 = -3.86 kNm
34 - 12 x (M1/M2) = 30.92
7.53 < 30.92, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 93.12 kNm
M2 = -238.6 kNm
34 - 12 x (M1/M2) = 38.68
7.53 < 38.68, Column not slender along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 296 of 523

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -0.99 - -0.99
Major Axis Mux (bottom) -3.86 - -3.86
Minor Axis Muy (top) 93.12 - 93.12
Minor Axis Muy (bottom) -238.6 - -238.6

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 128.31 kN
Mux = -3.86 kNm
Muy = -238.6 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 89.07 deg
MRes = 238.63 kNm
MCap = 249.96 kNm
Capacity Ratio = MRes/ MCap
= 0.955 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 630.49 kN
Muy = 50.55 kNm
Vuy = 130.9003 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 71.6 kNm
Vcy Permissible = 393.45 kN
Vuy < Vcy Permissible

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 297 of 523

Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 1672.92 kN
Mux = 228.44 kNm
Vux = -166.9902 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 95.69 kNm
Vcx Permissible = 512.75 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C20
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 298 of 523

Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 151
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 177.74 kN
Muxt = 7.84 kNm
Muyt = 298.02 kNm
Vuxt = 174.75 kN
Vuyt = -4.56 kN
Pub = 191.77 kN
Muxb = -8.11 kNm
Muyb = -313.46 kNm
Vuxb = 174.75 kN
Vuyb = -4.56 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 299 of 523

N-M mm mm N-M N-M


6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.548
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 7.84 kNm
M2 = -8.11 kNm
34 - 12 x (M1/M2) = 45.6
20.44 < 45.6, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 298.02 kNm
M2 = -313.46 kNm
34 - 12 x (M1/M2) = 45.41
20.44 < 45.41, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 7.84 - 7.84
Major Axis Mux (bottom) -8.11 - -8.11
Minor Axis Muy (top) 298.02 - 298.02
Minor Axis Muy (bottom) -313.46 - -313.46

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 300 of 523

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 191.77 kN
Mux = -8.11 kNm
Muy = -313.46 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 88.52 deg
MRes = 313.57 kNm
MCap = 318.84 kNm
Capacity Ratio = MRes/ MCap
= 0.983 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 517.3 kN
Muy = 202.74 kNm
Vuy = 121.935 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 102.51 kNm
Vcy Permissible = 172.78 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 780.92 kN
Mux = 250.45 kNm
Vux = -152.7696 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 301 of 523

λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 99.15 kNm
Vcx Permissible = 172.89 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C20
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 302 of 523

Load Data
Analysis Reference No. = 274
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 175.17 kN
Muxt = 12.28 kNm
Muyt = 267.09 kNm
Vuxt = 145.85 kN
Vuyt = -6.72 kN
Pub = 189.19 kN
Muxb = -11.22 kNm
Muyb = -243.26 kNm
Vuxb = 145.85 kN
Vuyb = -6.72 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 303 of 523

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -11.22 kNm
M2 = 12.28 kNm
34 - 12 x (M1/M2) = 44.96
20.44 < 44.96, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -243.26 kNm
M2 = 267.09 kNm
34 - 12 x (M1/M2) = 44.93
20.44 < 44.93, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 12.28 - 12.28
Major Axis Mux (bottom) -11.22 - -11.22
Minor Axis Muy (top) 267.09 - 267.09
Minor Axis Muy (bottom) -243.26 - -243.26

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 175.17 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 304 of 523

Mux = 12.28 kNm


Muy = 267.09 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 87.37 deg
MRes = 267.37 kNm
MCap = 315.44 kNm
Capacity Ratio = MRes/ MCap
= 0.848 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 672.33 kN
Muy = 141.34 kNm
Vuy = 88.3534 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 11.08 kNm
Vcy Permissible = 173.09 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 439.31 kN
Mux = 183.1 kNm
Vux = -112.8025 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 97.98 kNm
Vcx Permissible = 172.97 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 305 of 523

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C20
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 397
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 331.19 kN
Muxt = 8.44 kNm
Muyt = 215.86 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 306 of 523

Vuxt = 109.09 kN
Vuyt = -6.12 kN
Pub = 360.47 kN
Muxb = -12.99 kNm
Muyb = -165.84 kNm
Vuxb = 109.09 kN
Vuyb = -6.12 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 307 of 523

0.009< 0.05, Column shall be designed as non-sway frame


(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = 8.44 kNm
M2 = -12.99 kNm
34 - 12 x (M1/M2) = 41.8
17.37 < 41.8, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = -165.84 kNm
M2 = 215.86 kNm
34 - 12 x (M1/M2) = 43.22
16.55 < 43.22, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 8.44 - 8.44
Major Axis Mux (bottom) -12.99 - -12.99
Minor Axis Muy (top) 215.86 - 215.86
Minor Axis Muy (bottom) -165.84 - -165.84

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 331.19 kN
Mux = 8.44 kNm
Muy = 215.86 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 308 of 523

Load Angle = Tan-1(Muy/Mux)


= 87.76 deg
MRes = 216.02 kNm
MCap = 282.65 kNm
Capacity Ratio = MRes/ MCap
= 0.764 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 543.03 kN
Muy = 16.58 kNm
Vuy = -7.2738 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 88.64 kNm
Vcy Permissible = 381.74 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 117.62 kN
Mux = 113.88 kNm
Vux = 76.5814 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 91.09 kNm
Vcx Permissible = 171.61 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 309 of 523

Criterion for spacing of normal


links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C21
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 106
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 131.13 kN
Muxt = 0.41 kNm
Muyt = 79.46 kNm
Vuxt = 166.59 kN
Vuyt = -2.7 kN
Pub = 138.34 kN
Muxb = -4.45 kNm
Muyb = -220.33 kNm
Vuxb = 166.59 kN
Vuyb = -2.7 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 310 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x 2400 x 350 x
Top 265.195 74.125 185.312 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 0.41 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 311 of 523

M2 = -4.45 kNm
34 - 12 x (M1/M2) = 35.1
7.53 < 35.1, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 79.46 kNm
M2 = -220.33 kNm
34 - 12 x (M1/M2) = 38.33
7.53 < 38.33, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 0.41 - 0.41
Major Axis Mux (bottom) -4.45 - -4.45
Minor Axis Muy (top) 79.46 - 79.46
Minor Axis Muy (bottom) -220.33 - -220.33

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 138.34 kN
Mux = -4.45 kNm
Muy = -220.33 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.84 deg
MRes = 220.38 kNm
MCap = 251.86 kNm
Capacity Ratio = MRes/ MCap
= 0.875 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 312 of 523

[19] : 0.68 (LOAD 3: DL) +1.25


Critical Load Combination = kN
(LOAD 1: EX)
Nu = 580.79 kN
Muy = 46.17 kNm
Vuy = 127.4337 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 66.35 kNm
Vcy Permissible = 386.84 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 1613.69 kN
Mux = 222.04 kNm
Vux = -170.0013 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 90.61 kNm
Vcx Permissible = 506.73 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 313 of 523

Spacing 250 --- --- 250 ---

General Data
Column No. : C21
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 153
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 201.36 kN
Muxt = 6.39 kNm
Muyt = 279.05 kNm
Vuxt = 162.76 kN
Vuyt = -4.12 kN
Pub = 215.38 kN
Muxb = -8.03 kNm
Muyb = -290.45 kNm
Vuxb = 162.76 kN
Vuyb = -4.12 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 314 of 523

5000 x 350 x 5000 x 350 x


Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.548
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 6.39 kNm
M2 = -8.03 kNm
34 - 12 x (M1/M2) = 43.56
20.44 < 43.56, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 279.05 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 315 of 523

M2 = -290.45 kNm
34 - 12 x (M1/M2) = 45.53
20.44 < 45.53, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 6.39 - 6.39
Major Axis Mux (bottom) -8.03 - -8.03
Minor Axis Muy (top) 279.05 - 279.05
Minor Axis Muy (bottom) -290.45 - -290.45

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 215.38 kN
Mux = -8.03 kNm
Muy = -290.45 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 88.42 deg
MRes = 290.56 kNm
MCap = 322.21 kNm
Capacity Ratio = MRes/ MCap
= 0.902 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 1001.76 kN
Muy = 204.13 kNm
Vuy = -123.8679 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 316 of 523

mm = 10.04 kNm
Vcy Permissible = 172.85 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 771.37 kN
Mux = 235.67 kNm
Vux = -144.8182 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 86.22 kNm
Vcx Permissible = 172.95 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C21
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 317 of 523

Grade Of Concrete = C21 N/sqmm


Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 276
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 183.17 kN
Muxt = 8.34 kNm
Muyt = 252.91 kNm
Vuxt = 138.4 kN
Vuyt = -4.65 kN
Pub = 197.2 kN
Muxb = -7.92 kNm
Muyb = -231.35 kNm
Vuxb = 138.4 kN
Vuyb = -4.65 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 318 of 523

Stiffness Beam 1 Beam 2 Beam 1 Beam 2


(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -7.92 kNm
M2 = 8.34 kNm
34 - 12 x (M1/M2) = 45.4
20.44 < 45.4, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -231.35 kNm
M2 = 252.91 kNm
34 - 12 x (M1/M2) = 44.98
20.44 < 44.98, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 8.34 - 8.34

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 319 of 523

Major Axis Mux (bottom) -7.92 - -7.92


Minor Axis Muy (top) 252.91 - 252.91
Minor Axis Muy (bottom) -231.35 - -231.35

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 183.17 kN
Mux = 8.34 kNm
Muy = 252.91 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.11 deg
MRes = 253.05 kNm
MCap = 260.03 kNm
Capacity Ratio = MRes/ MCap
= 0.973 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 667.06 kN
Muy = 143.01 kNm
Vuy = 90.1652 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 13.77 kNm
Vcy Permissible = 171.19 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 320 of 523

Nu = 435.61 kN
Mux = 171.97 kNm
Vux = -105.9507 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 87.57 kNm
Vcx Permissible = 171.05 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C21
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 321 of 523

No Of Columns In Group = 1

Load Data
Analysis Reference No. = 399
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 321.37 kN
Muxt = 13.68 kNm
Muyt = 207.61 kNm
Vuxt = 104.79 kN
Vuyt = -6.54 kN
Pub = 350.65 kN
Muxb = -9.19 kNm
Muyb = -159.04 kNm
Vuxb = 104.79 kN
Vuyb = -6.54 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 0.526
550 550
Sway Condition (as per Stability

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 322 of 523

Index) = Non Sway


Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = -9.19 kNm
M2 = 13.68 kNm
34 - 12 x (M1/M2) = 42.06
17.37 < 42.06, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = -159.04 kNm
M2 = 207.61 kNm
34 - 12 x (M1/M2) = 43.19
16.55 < 43.19, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 13.68 - 13.68
Major Axis Mux (bottom) -9.19 - -9.19
Minor Axis Muy (top) 207.61 - 207.61
Minor Axis Muy (bottom) -159.04 - -159.04

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 323 of 523

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 321.37 kN
Mux = 13.68 kNm
Muy = 207.61 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 86.23 deg
MRes = 208.06 kNm
MCap = 280.35 kNm
Capacity Ratio = MRes/ MCap
= 0.742 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 528.29 kN
Muy = 11.2 kNm
Vuy = -7.8215 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 91.15 kNm
Vcy Permissible = 379.74 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 114.27 kN
Mux = 109.53 kNm
Vux = 73.5599 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 87.39 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 324 of 523

Vcx Permissible = 171.6 kN


Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C22
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 108
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 325 of 523

Put = 158.39 kN
Muxt = 0.38 kNm
Muyt = 74.37 kNm
Vuxt = 155.63 kN
Vuyt = -2.68 kN
Pub = 165.61 kN
Muxb = -4.44 kNm
Muyb = -205.69 kNm
Vuxb = 155.63 kN
Vuyb = -2.68 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x 2400 x 350 x
Top 265.195 74.125 185.312 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 326 of 523

       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 0.38 kNm
M2 = -4.44 kNm
34 - 12 x (M1/M2) = 35.04
7.53 < 35.04, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 74.37 kNm
M2 = -205.69 kNm
34 - 12 x (M1/M2) = 38.34
7.53 < 38.34, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 0.38 - 0.38
Major Axis Mux (bottom) -4.44 - -4.44
Minor Axis Muy (top) 74.37 - 74.37
Minor Axis Muy (bottom) -205.69 - -205.69

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 165.61 kN
Mux = -4.44 kNm
Muy = -205.69 kNm

Moment Capacity Check


Pt Calculated = 1.15

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 327 of 523

Reinforcement Provided = 4-#20 + 8-#16


Load Angle = Tan-1(Muy/Mux)
= 88.76 deg
MRes = 205.74 kNm
MCap = 256.96 kNm
Capacity Ratio = MRes/ MCap
= 0.801 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 571.29 kN
Muy = 46.3 kNm
Vuy = 127.5343 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 64.39 kNm
Vcy Permissible = 385.56 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 2: EZ)
Nu = 1060.89 kN
Mux = 203.23 kNm
Vux = 151.6286 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 2.32 kNm
Vcx Permissible = 446.58 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 328 of 523

= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C22
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 155
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 219.57 kN
Muxt = 6.56 kNm
Muyt = 261.39 kNm
Vuxt = 152.39 kN
Vuyt = -4.19 kN
Pub = 233.59 kN
Muxb = -8.1 kNm
Muyb = -271.81 kNm
Vuxb = 152.39 kN
Vuyb = -4.19 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 329 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.548
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 330 of 523

Kluy /r = 20.44
M1 = 6.56 kNm
M2 = -8.1 kNm
34 - 12 x (M1/M2) = 43.72
20.44 < 43.72, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 261.39 kNm
M2 = -271.81 kNm
34 - 12 x (M1/M2) = 45.54
20.44 < 45.54, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 6.56 - 6.56
Major Axis Mux (bottom) -8.1 - -8.1
Minor Axis Muy (top) 261.39 - 261.39
Minor Axis Muy (bottom) -271.81 - -271.81

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 233.59 kN
Mux = -8.1 kNm
Muy = -271.81 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 88.29 deg
MRes = 271.94 kNm
MCap = 324.78 kNm
Capacity Ratio = MRes/ MCap
= 0.837 < 1

Design Of Shear

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 331 of 523

Design for shear along D


Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 1013.99 kN
Muy = 204.78 kNm
Vuy = -124.1482 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 8.32 kNm
Vcy Permissible = 172.84 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 757.54 kN
Mux = 219.69 kNm
Vux = -135.2846 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 72.92 kNm
Vcx Permissible = 172.96 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 332 of 523

Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C22
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 278
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 188.23 kN
Muxt = 8.86 kNm
Muyt = 238.97 kNm
Vuxt = 130.82 kN
Vuyt = -4.9 kN
Pub = 202.26 kN
Muxb = -8.3 kNm
Muyb = -218.76 kNm
Vuxb = 130.82 kN
Vuyb = -4.9 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 333 of 523

N-M mm mm N-M N-M


5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -8.3 kNm
M2 = 8.86 kNm
34 - 12 x (M1/M2) = 45.25
20.44 < 45.25, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 334 of 523

Klux /r = 20.44
M1 = -218.76 kNm
M2 = 238.97 kNm
34 - 12 x (M1/M2) = 44.98
20.44 < 44.98, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 8.86 - 8.86
Major Axis Mux (bottom) -8.3 - -8.3
Minor Axis Muy (top) 238.97 - 238.97
Minor Axis Muy (bottom) -218.76 - -218.76

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 188.23 kN
Mux = 8.86 kNm
Muy = 238.97 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.88 deg
MRes = 239.14 kNm
MCap = 260.7 kNm
Capacity Ratio = MRes/ MCap
= 0.917 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 661.94 kN
Muy = 142.5 kNm
Vuy = 89.7407 kN
λ = 1
φ = 0.65

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 335 of 523

deff = 450 mm
ρw = 0.006
mm = 14.25 kNm
Vcy Permissible = 171.18 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 429.16 kN
Mux = 161.67 kNm
Vux = -99.2987 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 78.52 kNm
Vcx Permissible = 171.03 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C22

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 336 of 523

Level : 8.8m To 12.3m


Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 401
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 323.32 kN
Muxt = 12.74 kNm
Muyt = 199.59 kNm
Vuxt = 100.93 kN
Vuyt = -6.39 kN
Pub = 352.61 kN
Muxb = -9.62 kNm
Muyb = -153.57 kNm
Vuxb = 100.93 kN
Vuyb = -6.39 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 337 of 523

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = -9.62 kNm
M2 = 12.74 kNm
34 - 12 x (M1/M2) = 43.07
17.37 < 43.07, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = -153.57 kNm
M2 = 199.59 kNm
34 - 12 x (M1/M2) = 43.23
16.55 < 43.23, Column not slender along B

Calculation of Design Moment

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 338 of 523

Direction Manalysis Msldr or Mc Mdesign-final


A B C
Major Axis Mux (top) 12.74 - 12.74
Major Axis Mux (bottom) -9.62 - -9.62
Minor Axis Muy (top) 199.59 - 199.59
Minor Axis Muy (bottom) -153.57 - -153.57

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 323.32 kN
Mux = 12.74 kNm
Muy = 199.59 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 86.35 deg
MRes = 200 kNm
MCap = 280.72 kNm
Capacity Ratio = MRes/ MCap
= 0.712 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 530.99 kN
Muy = 11.71 kNm
Vuy = -7.5446 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 91.17 kNm
Vcy Permissible = 380.1 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 339 of 523

Critical Analysis Load Combination : 26


[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 115.18 kN
Mux = 105.89 kNm
Vux = 70.8331 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 83.58 kNm
Vcx Permissible = 171.57 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C23
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 340 of 523

Clear Floor Height @ lux = 1250 mm


Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 110
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 206.36 kN
Muxt = 0.34 kNm
Muyt = 76.49 kNm
Vuxt = 150.38 kN
Vuyt = -2.65 kN
Pub = 213.57 kN
Muxb = -4.43 kNm
Muyb = -194.12 kNm
Vuxb = 150.38 kN
Vuyb = -2.65 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x 2400 x 350 x
Top 265.195 74.125 185.312 1.548
550 550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 341 of 523

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 0.34 kNm
M2 = -4.43 kNm
34 - 12 x (M1/M2) = 34.93
7.53 < 34.93, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 76.49 kNm
M2 = -194.12 kNm
34 - 12 x (M1/M2) = 38.73
7.53 < 38.73, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 0.34 - 0.34
Major Axis Mux (bottom) -4.43 - -4.43
Minor Axis Muy (top) 76.49 - 76.49
Minor Axis Muy (bottom) -194.12 - -194.12

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 342 of 523

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 213.57 kN
Mux = -4.43 kNm
Muy = -194.12 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.69 deg
MRes = 194.17 kNm
MCap = 265.02 kNm
Capacity Ratio = MRes/ MCap
= 0.733 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 587.34 kN
Muy = 44.59 kNm
Vuy = -126.803 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 69.2 kNm
Vcy Permissible = 387.72 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 2: EZ)
Nu = 1134.92 kN
Mux = 194.71 kNm
Vux = 152.6776 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 343 of 523

mm = 25.18 kNm
Vcx Permissible = 455.1 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C23
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 157
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 344 of 523

Critical Location = Bottom Joint


Put = 235.59 kN
Muxt = 6.6 kNm
Muyt = 246.13 kNm
Vuxt = 143.93 kN
Vuyt = -4.2 kN
Pub = 249.62 kN
Muxb = -8.1 kNm
Muyb = -257.49 kNm
Vuxb = 143.93 kN
Vuyb = -4.2 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.548
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023

0.023< 0.05, Column shall be designed as non-sway frame

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 345 of 523

(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 6.6 kNm
M2 = -8.1 kNm
34 - 12 x (M1/M2) = 43.78
20.44 < 43.78, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 246.13 kNm
M2 = -257.49 kNm
34 - 12 x (M1/M2) = 45.47
20.44 < 45.47, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 6.6 - 6.6
Major Axis Mux (bottom) -8.1 - -8.1
Minor Axis Muy (top) 246.13 - 246.13
Minor Axis Muy (bottom) -257.49 - -257.49

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 249.62 kN
Mux = -8.1 kNm
Muy = -257.49 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 346 of 523

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.2 deg
MRes = 257.62 kNm
MCap = 270.44 kNm
Capacity Ratio = MRes/ MCap
= 0.953 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 1022.24 kN
Muy = 204.83 kNm
Vuy = -124.1596 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 6.77 kNm
Vcy Permissible = 170.95 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 741.64 kN
Mux = 201.32 kNm
Vux = -123.8345 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 57.63 kNm
Vcx Permissible = 171.04 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 347 of 523

Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C23
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 280
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 196.9 kN
Muxt = 8.61 kNm
Muyt = 224.5 kNm
Vuxt = 123.1 kN
Vuyt = -4.81 kN
Pub = 210.93 kN
Muxb = -8.22 kNm
Muyb = -206.24 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 348 of 523

Vuxb = 123.1 kN
Vuyb = -4.81 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 349 of 523

Slenderness Check along D


K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -8.22 kNm
M2 = 8.61 kNm
34 - 12 x (M1/M2) = 45.47
20.44 < 45.47, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -206.24 kNm
M2 = 224.5 kNm
34 - 12 x (M1/M2) = 45.02
20.44 < 45.02, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 8.61 - 8.61
Major Axis Mux (bottom) -8.22 - -8.22
Minor Axis Muy (top) 224.5 - 224.5
Minor Axis Muy (bottom) -206.24 - -206.24

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 196.9 kN
Mux = 8.61 kNm
Muy = 224.5 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.8 deg
MRes = 224.67 kNm
MCap = 261.97 kNm
Capacity Ratio = MRes/ MCap

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 350 of 523

= 0.858 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 664.4 kN
Muy = 142.52 kNm
Vuy = 89.8806 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 13.8 kNm
Vcy Permissible = 171.19 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 426.32 kN
Mux = 151.29 kNm
Vux = -92.7782 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 68.69 kNm
Vcx Permissible = 171.02 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 351 of 523

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C23
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 403
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 327.53 kN
Muxt = 14.41 kNm
Muyt = 189.94 kNm
Vuxt = 96.04 kN
Vuyt = -6.91 kN
Pub = 356.82 kN
Muxb = -9.78 kNm
Muyb = -146.13 kNm
Vuxb = 96.04 kN
Vuyb = -6.91 kN

Effective Length Calculation

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 352 of 523

Calculation Along Major Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = -9.78 kNm
M2 = 14.41 kNm
34 - 12 x (M1/M2) = 42.15

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 353 of 523

17.37 < 42.15, Column not slender along D


Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = -146.13 kNm
M2 = 189.94 kNm
34 - 12 x (M1/M2) = 43.23
16.55 < 43.23, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 14.41 - 14.41
Major Axis Mux (bottom) -9.78 - -9.78
Minor Axis Muy (top) 189.94 - 189.94
Minor Axis Muy (bottom) -146.13 - -146.13

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 327.53 kN
Mux = 14.41 kNm
Muy = 189.94 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 85.66 deg
MRes = 190.48 kNm
MCap = 281.15 kNm
Capacity Ratio = MRes/ MCap
= 0.678 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 354 of 523

Nu = 536.06 kN
Muy = 11.82 kNm
Vuy = -8.2415 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 92.05 kNm
Vcy Permissible = 380.8 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 117.05 kN
Mux = 101.31 kNm
Vux = 67.6108 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 78.63 kNm
Vcx Permissible = 171.56 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 355 of 523

General Data
Column No. : C24
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 112
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 1807.2 kN
Muxt = -2.92 kNm
Muyt = -70.37 kNm
Vuxt = -140.45 kN
Vuyt = 3.59 kN
Pub = 1822.26 kN
Muxb = 3.53 kNm
Muyb = 182.37 kNm
Vuxb = -140.45 kN
Vuyb = 3.59 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 356 of 523

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x 2400 x 350 x
Top 265.195 74.125 185.312 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -2.92 kNm
M2 = 3.53 kNm
34 - 12 x (M1/M2) = 43.92
7.53 < 43.92, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = -70.37 kNm
M2 = 182.37 kNm
34 - 12 x (M1/M2) = 38.63
7.53 < 38.63, Column not slender along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 357 of 523

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -2.92 - -2.92
Major Axis Mux (bottom) 3.53 - 3.53
Minor Axis Muy (top) -70.37 - -70.37
Minor Axis Muy (bottom) 182.37 - 182.37

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1822.26 kN
Mux = 3.53 kNm
Muy = 182.37 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.89 deg
MRes = 182.4 kNm
MCap = 265.31 kNm
Capacity Ratio = MRes/ MCap
= 0.688 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 586.81 kN
Muy = 45.96 kNm
Vuy = -127.8875 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 67.73 kNm
Vcy Permissible = 387.65 kN
Vuy < Vcy Permissible

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 358 of 523

Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 216.62 kN
Mux = 63.54 kNm
Vux = 133.2008 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 21.57 kNm
Vcx Permissible = 185.65 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C24
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 359 of 523

Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 159
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 257.28 kN
Muxt = 6.22 kNm
Muyt = 226.95 kNm
Vuxt = 131.93 kN
Vuyt = -4.14 kN
Pub = 271.3 kN
Muxb = -8.27 kNm
Muyb = -234.69 kNm
Vuxb = 131.93 kN
Vuyb = -4.14 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 360 of 523

N-M mm mm N-M N-M


6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.548
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 6.22 kNm
M2 = -8.27 kNm
34 - 12 x (M1/M2) = 43.02
20.44 < 43.02, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 226.95 kNm
M2 = -234.69 kNm
34 - 12 x (M1/M2) = 45.6
20.44 < 45.6, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 6.22 - 6.22
Major Axis Mux (bottom) -8.27 - -8.27
Minor Axis Muy (top) 226.95 - 226.95
Minor Axis Muy (bottom) -234.69 - -234.69

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 361 of 523

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 271.3 kN
Mux = -8.27 kNm
Muy = -234.69 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.98 deg
MRes = 234.83 kNm
MCap = 273.55 kNm
Capacity Ratio = MRes/ MCap
= 0.858 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 1041.59 kN
Muy = 204.03 kNm
Vuy = -124.036 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 2.22 kNm
Vcy Permissible = 170.97 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 727.47 kN
Mux = 187.02 kNm
Vux = -116.0014 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 362 of 523

λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 46.08 kNm
Vcx Permissible = 171.09 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C24
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 363 of 523

Load Data
Analysis Reference No. = 282
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 204.8 kN
Muxt = 9.46 kNm
Muyt = 209.65 kNm
Vuxt = 115.27 kN
Vuyt = -5.04 kN
Pub = 218.83 kN
Muxb = -8.17 kNm
Muyb = -193.69 kNm
Vuxb = 115.27 kN
Vuyb = -5.04 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 364 of 523

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -8.17 kNm
M2 = 9.46 kNm
34 - 12 x (M1/M2) = 44.36
20.44 < 44.36, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -193.69 kNm
M2 = 209.65 kNm
34 - 12 x (M1/M2) = 45.09
20.44 < 45.09, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 9.46 - 9.46
Major Axis Mux (bottom) -8.17 - -8.17
Minor Axis Muy (top) 209.65 - 209.65
Minor Axis Muy (bottom) -193.69 - -193.69

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 204.8 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 365 of 523

Mux = 9.46 kNm


Muy = 209.65 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.42 deg
MRes = 209.86 kNm
MCap = 262.85 kNm
Capacity Ratio = MRes/ MCap
= 0.798 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 663.09 kN
Muy = 145.03 kNm
Vuy = 90.5379 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 16.56 kNm
Vcy Permissible = 171.13 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 421.3 kN
Mux = 141.16 kNm
Vux = -86.4931 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 59.53 kNm
Vcx Permissible = 171.02 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 366 of 523

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C24
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 405
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 310.27 kN
Muxt = 1.38 kNm
Muyt = 180.32 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 367 of 523

Vuxt = 90.91 kN
Vuyt = -2.11 kN
Pub = 339.56 kN
Muxb = -6 kNm
Muyb = -137.78 kNm
Vuxb = 90.91 kN
Vuyb = -2.11 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 368 of 523

0.009< 0.05, Column shall be designed as non-sway frame


(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = 1.38 kNm
M2 = -6 kNm
34 - 12 x (M1/M2) = 36.76
17.37 < 36.76, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = -137.78 kNm
M2 = 180.32 kNm
34 - 12 x (M1/M2) = 43.17
16.55 < 43.17, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 1.38 - 1.38
Major Axis Mux (bottom) -6 - -6
Minor Axis Muy (top) 180.32 - 180.32
Minor Axis Muy (bottom) -137.78 - -137.78

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 310.27 kN
Mux = 1.38 kNm
Muy = 180.32 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 369 of 523

Load Angle = Tan-1(Muy/Mux)


= 89.56 deg
MRes = 180.33 kNm
MCap = 281 kNm
Capacity Ratio = MRes/ MCap
= 0.642 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 509.88 kN
Muy = 6.36 kNm
Vuy = -1.1854 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 92.43 kNm
Vcy Permissible = 377.21 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 111.37 kN
Mux = 96.43 kNm
Vux = 64.3417 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 74.85 kNm
Vcx Permissible = 171.55 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 370 of 523

Criterion for spacing of normal


links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C25
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 114
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Bottom Joint
Put = 1648.18 kN
Muxt = -31.86 kNm
Muyt = 20.39 kNm
Vuxt = 20.77 kN
Vuyt = 115.62 kN
Pub = 1663.24 kN
Muxb = 176.2 kNm
Muyb = -16.99 kNm
Vuxb = 20.77 kN
Vuyb = 115.62 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 371 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
10000 x 350 x 5000 x 350 x
Top 265.195 44.475 88.95 3.011
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x 2400 x 350 x
Top 265.195 74.125 185.312 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 372 of 523

M1 = -31.86 kNm
M2 = 176.2 kNm
34 - 12 x (M1/M2) = 36.17
7.53 < 36.17, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = -16.99 kNm
M2 = 20.39 kNm
34 - 12 x (M1/M2) = 44
7.53 < 44, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -31.86 - -31.86
Major Axis Mux (bottom) 176.2 - 176.2
Minor Axis Muy (top) 20.39 - 20.39
Minor Axis Muy (bottom) -16.99 - -16.99

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1663.24 kN
Mux = 176.2 kNm
Muy = -16.99 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 5.51 deg
MRes = 177.02 kNm
MCap = 272.44 kNm
Capacity Ratio = MRes/ MCap
= 0.65 < 1

Design Of Shear
Design for shear along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 373 of 523

Critical Analysis Load Combination : 23


[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 694.85 kN
Muy = 175.1 kNm
Vuy = 112.4199 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 40.47 kNm
Vcy Permissible = 171.31 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 250.73 kN
Mux = 68.72 kNm
Vux = 130.3639 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 20.14 kNm
Vcx Permissible = 183.68 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 374 of 523

Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C25
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 161
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 1149.01 kN
Muxt = 28.08 kNm
Muyt = 255.7 kNm
Vuxt = 142.43 kN
Vuyt = -12.66 kN
Pub = 1178.29 kN
Muxb = -16.22 kNm
Muyb = -242.69 kNm
Vuxb = 142.43 kN
Vuyb = -12.66 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 375 of 523

N-M mm mm N-M N-M


10000 x 350 x 5000 x 350 x
Bottom 136.386 44.475 88.95 3.011
550 550
10000 x 350 x 5000 x 350 x
Top 136.386 44.475 88.95 2.045
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.548
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -16.22 kNm
M2 = 28.08 kNm
34 - 12 x (M1/M2) = 40.93
20.44 < 40.93, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 376 of 523

Klux /r = 20.44
M1 = -242.69 kNm
M2 = 255.7 kNm
34 - 12 x (M1/M2) = 45.39
20.44 < 45.39, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 28.08 - 28.08
Major Axis Mux (bottom) -16.22 - -16.22
Minor Axis Muy (top) 255.7 - 255.7
Minor Axis Muy (bottom) -242.69 - -242.69

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1149.01 kN
Mux = 28.08 kNm
Muy = 255.7 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 83.73 deg
MRes = 257.23 kNm
MCap = 316.43 kNm
Capacity Ratio = MRes/ MCap
= 0.813 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 577.18 kN
Muy = 165.18 kNm
Vuy = 103.1353 kN
λ = 1
φ = 0.65

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 377 of 523

deff = 450 mm
ρw = 0.006
mm = 53.35 kNm
Vcy Permissible = 171.13 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 755.48 kN
Mux = 171.17 kNm
Vux = -105.5231 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 24.8 kNm
Vcx Permissible = 171.05 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C25

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 378 of 523

Level : 5.3m To 8.8m


Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 284
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Top Joint
Put = 228.33 kN
Muxt = 8.69 kNm
Muyt = 203.79 kNm
Vuxt = 112.36 kN
Vuyt = -5.57 kN
Pub = 242.35 kN
Muxb = -10.79 kNm
Muyb = -189.37 kNm
Vuxb = 112.36 kN
Vuyb = -5.57 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
10000 x 350 x 5000 x 350 x
Bottom 136.386 44.475 88.95 2.045
550 550
10000 x 350 x 5000 x 350 x
Top 136.386 44.475 88.95 2.045
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 379 of 523

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 8.69 kNm
M2 = -10.79 kNm
34 - 12 x (M1/M2) = 43.66
20.44 < 43.66, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -189.37 kNm
M2 = 203.79 kNm
34 - 12 x (M1/M2) = 45.15
20.44 < 45.15, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 380 of 523

A B C
Major Axis Mux (top) 8.69 - 8.69
Major Axis Mux (bottom) -10.79 - -10.79
Minor Axis Muy (top) 203.79 - 203.79
Minor Axis Muy (bottom) -189.37 - -189.37

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 228.33 kN
Mux = 8.69 kNm
Muy = 203.79 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.56 deg
MRes = 203.97 kNm
MCap = 266.61 kNm
Capacity Ratio = MRes/ MCap
= 0.765 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 373.39 kN
Muy = 112.23 kNm
Vuy = 74.5207 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 39.89 kNm
Vcy Permissible = 171.52 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 381 of 523

[20] : 0.68 (LOAD 3: DL) +1.25


Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 450.61 kN
Mux = 133.43 kNm
Vux = -81.0552 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 46.12 kNm
Vcx Permissible = 170.96 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C25
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 382 of 523

Clear Floor Height @ luy = 2950 mm


No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 407
Critical Analysis Load Combination : 14
Load Combination = [10] : 1.2 (LOAD 3: DL) +1.6 (LOAD 4: LL)
Critical Location = Top Joint
Put = 658.18 kN
Muxt = 174.76 kNm
Muyt = 147.88 kNm
Vuxt = 72.77 kN
Vuyt = -76.98 kN
Pub = 682.93 kN
Muxb = -94.58 kNm
Muyb = -106.75 kNm
Vuxb = 72.77 kN
Vuyb = -76.98 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
10000 x 350 x 5000 x 350 x
Bottom 136.386 44.475 88.95 2.045
550 550
10000 x 350 x 5000 x 350 x
Top 136.386 44.475 88.95 1.023
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 0.526
550 550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 383 of 523

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -94.58 kNm
M2 = 174.76 kNm
34 - 12 x (M1/M2) = 40.49
20.44 < 40.49, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = -106.75 kNm
M2 = 147.88 kNm
34 - 12 x (M1/M2) = 42.66
16.55 < 42.66, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 174.76 - 174.76
Major Axis Mux (bottom) -94.58 - -94.58
Minor Axis Muy (top) 147.88 - 147.88
Minor Axis Muy (bottom) -106.75 - -106.75

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 384 of 523

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 658.18 kN
Mux = 174.76 kNm
Muy = 147.88 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 40.24 deg
MRes = 228.94 kNm
MCap = 269.84 kNm
Capacity Ratio = MRes/ MCap
= 0.848 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 463.9 kN
Muy = 114.55 kNm
Vuy = -92.1552 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 24.67 kNm
Vcy Permissible = 172.91 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 2: EZ)
Nu = 451.46 kN
Mux = 150.32 kNm
Vux = 99.496 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 385 of 523

mm = 62.85 kNm
Vcx Permissible = 171.5 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C26
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 100
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 386 of 523

Critical Location = Bottom Joint


Put = 99.97 kN
Muxt = 1.7 kNm
Muyt = 59.53 kNm
Vuxt = 109.22 kN
Vuyt = -3.73 kN
Pub = 107.18 kN
Muxb = -5 kNm
Muyb = -137.02 kNm
Vuxb = 109.22 kN
Vuyb = -3.73 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
10000 x 350 x
Top 265.195 No Beam - 44.475 9.034
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x 2400 x 350 x
Top 265.195 74.125 185.312 1.548
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 387 of 523

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 1.7 kNm
M2 = -5 kNm
34 - 12 x (M1/M2) = 38.09
7.53 < 38.09, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 59.53 kNm
M2 = -137.02 kNm
34 - 12 x (M1/M2) = 39.21
7.53 < 39.21, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 1.7 - 1.7
Major Axis Mux (bottom) -5 - -5
Minor Axis Muy (top) 59.53 - 59.53
Minor Axis Muy (bottom) -137.02 - -137.02

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 107.18 kN
Mux = -5 kNm
Muy = -137.02 kNm

Moment Capacity Check

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 388 of 523

Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.91 deg
MRes = 137.12 kNm
MCap = 246.07 kNm
Capacity Ratio = MRes/ MCap
= 0.557 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 450.44 kN
Muy = 149.94 kNm
Vuy = 65.5086 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 62.67 kNm
Vcy Permissible = 169.28 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 99.97 kN
Mux = 59.53 kNm
Vux = 109.2239 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 40.16 kNm
Vcx Permissible = 183.07 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 389 of 523

> Max. longitudinal bar dia / 4


= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C26
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 146
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 129.3 kN
Muxt = -17.34 kNm
Muyt = 176.52 kNm
Vuxt = 103.3 kN
Vuyt = 5.75 kN
Pub = 143.33 kN
Muxb = 2.78 kNm
Muyb = -184.94 kNm
Vuxb = 103.3 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 390 of 523

Vuyb = 5.75 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
10000 x 350 x
Bottom 136.386 No Beam - 44.475 9.034
550
10000 x 350 x
Top 136.386 No Beam - 44.475 6.136
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.548
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 391 of 523

K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 2.78 kNm
M2 = -17.34 kNm
34 - 12 x (M1/M2) = 35.92
20.44 < 35.92, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 176.52 kNm
M2 = -184.94 kNm
34 - 12 x (M1/M2) = 45.45
20.44 < 45.45, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -17.34 - -17.34
Major Axis Mux (bottom) 2.78 - 2.78
Minor Axis Muy (top) 176.52 - 176.52
Minor Axis Muy (bottom) -184.94 - -184.94

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 143.33 kN
Mux = 2.78 kNm
Muy = -184.94 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 89.14 deg
MRes = 184.96 kNm
MCap = 252.75 kNm
Capacity Ratio = MRes/ MCap
= 0.732 < 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 392 of 523

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 370.33 kN
Muy = 124.31 kNm
Vuy = 78.4382 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 52.55 kNm
Vcy Permissible = 171.2 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 535.32 kN
Mux = 144.45 kNm
Vux = -88.5149 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 40.74 kNm
Vcx Permissible = 171.02 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 393 of 523

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C26
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 269
Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 462.23 kN
Muxt = -53.31 kNm
Muyt = 193.33 kNm
Vuxt = 107.01 kN
Vuyt = 37.1 kN
Pub = 491.52 kN
Muxb = 76.5 kNm
Muyb = -181.09 kNm
Vuxb = 107.01 kN
Vuyb = 37.1 kN

Effective Length Calculation


Calculation Along Major Axis Of Column

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 394 of 523

Joint Column Beam Sizes Beam Stiffness Beta


Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
10000 x 350 x
Bottom 136.386 No Beam - 44.475 6.136
550
10000 x 350 x
Top 136.386 No Beam - 44.475 6.136
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 1.052
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -53.31 kNm
M2 = 76.5 kNm
34 - 12 x (M1/M2) = 42.36
20.44 < 42.36, Column not slender along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 395 of 523

Column Is Braced Along B


Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -181.09 kNm
M2 = 193.33 kNm
34 - 12 x (M1/M2) = 45.24
20.44 < 45.24, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -53.31 - -53.31
Major Axis Mux (bottom) 76.5 - 76.5
Minor Axis Muy (top) 193.33 - 193.33
Minor Axis Muy (bottom) -181.09 - -181.09

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 462.23 kN
Mux = -53.31 kNm
Muy = 193.33 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 74.58 deg
MRes = 200.55 kNm
MCap = 293.56 kNm
Capacity Ratio = MRes/ MCap
= 0.683 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 494.24 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 396 of 523

Muy = 113.66 kNm


Vuy = 73.6412 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 17.9 kNm
Vcy Permissible = 171.36 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 317.35 kN
Mux = 120.89 kNm
Vux = -72.3067 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 59.4 kNm
Vcx Permissible = 170.87 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 397 of 523

General Data
Column No. : C26
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 392
Critical Analysis Load Combination : 14
Load Combination = [10] : 1.2 (LOAD 3: DL) +1.6 (LOAD 4: LL)
Critical Location = Top Joint
Put = 386.73 kN
Muxt = -310.27 kNm
Muyt = 84.33 kNm
Vuxt = 40.45 kN
Vuyt = 139.71 kN
Pub = 411.48 kN
Muxb = 178.57 kNm
Muyb = -57.22 kNm
Vuxb = 40.45 kN
Vuyb = 139.71 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
10000 x 350 x
Bottom 136.386 No Beam - 44.475 6.136
550
10000 x 350 x
Top 136.386 No Beam - 44.475 3.068
550
Sway Condition (as per Stability

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 398 of 523

Index) = Non Sway


Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x 2400 x 350 x
Bottom 136.386 74.125 185.312 1.052
550 550
6000 x 350 x 2400 x 350 x
Top 136.386 74.125 185.312 0.526
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.81
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 178.57 kNm
M2 = -310.27 kNm
34 - 12 x (M1/M2) = 40.91
20.44 < 40.91, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.81
r = 144.34 mm
Klux /r = 16.55
M1 = -57.22 kNm
M2 = 84.33 kNm
34 - 12 x (M1/M2) = 42.14
16.55 < 42.14, Column not slender along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 399 of 523

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -310.27 - -310.27
Major Axis Mux (bottom) 178.57 - 178.57
Minor Axis Muy (top) 84.33 - 84.33
Minor Axis Muy (bottom) -57.22 - -57.22

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 386.73 kN
Mux = -310.27 kNm
Muy = 84.33 kNm

Moment Capacity Check


Pt Calculated = 1.51
Reinforcement Provided = 12-#20
Load Angle = Tan-1(Muy/Mux)
= 15.21 deg
MRes = 321.53 kNm
MCap = 330.39 kNm
Capacity Ratio = MRes/ MCap
= 0.973 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 235.83 kN
Muy = 92.95 kNm
Vuy = 82.4792 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 47.26 kNm
Vcy Permissible = 176.49 kN
Vuy < Vcy Permissible

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 400 of 523

Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 18
[14] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 2: EZ)
Nu = 276.55 kN
Mux = 111.2 kNm
Vux = 73.6236 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.008
mm = 57.62 kNm
Vcx Permissible = 173.56 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 320 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C27
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 401 of 523

Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 80
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 206.7 kN
Muxt = 9.44 kNm
Muyt = -39.86 kNm
Vuxt = 86.02 kN
Vuyt = -18.17 kN
Pub = 213.91 kN
Muxb = -23.25 kNm
Muyb = -194.65 kNm
Vuxb = 86.02 kN
Vuyb = -18.17 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x
Top 265.195 No Beam 88.95 - 4.517
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 402 of 523

N-M mm mm N-M N-M


Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam - 74.125 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 9.44 kNm
M2 = -23.25 kNm
34 - 12 x (M1/M2) = 38.87
7.53 < 38.87, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = -39.86 kNm
M2 = -194.65 kNm
34 - 12 x (M1/M2) = 31.54
7.53 < 31.54, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 9.44 - 9.44
Major Axis Mux (bottom) -23.25 - -23.25
Minor Axis Muy (top) -39.86 - -39.86
Minor Axis Muy (bottom) -194.65 - -194.65

Where

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 403 of 523

A = Moments from analysis


B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 213.91 kN
Mux = -23.25 kNm
Muy = -194.65 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 83.19 deg
MRes = 196.03 kNm
MCap = 262.51 kNm
Capacity Ratio = MRes/ MCap
= 0.747 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 611.64 kN
Muy = 171.51 kNm
Vuy = -95.5967 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 53 kNm
Vcy Permissible = 170.47 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 1052.79 kN
Mux = 204.94 kNm
Vux = -108.1926 kN
λ = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 404 of 523

φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 0.96 kNm
Vcx Permissible = 170.18 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C27
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 405 of 523

Analysis Reference No. = 126


Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 1011.32 kN
Muxt = -34.43 kNm
Muyt = -233.1 kNm
Vuxt = -135.44 kN
Vuyt = 12.09 kN
Pub = 1040.61 kN
Muxb = 7.87 kNm
Muyb = 240.82 kNm
Vuxb = -135.44 kN
Vuyb = 12.09 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x
Bottom 136.386 No Beam 88.95 - 4.517
550
5000 x 350 x 2250 x 350 x
Top 136.386 88.95 197.666 0.952
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.86
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 5.409
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 406 of 523

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.86
r = 144.34 mm
Kluy /r = 17.58
M1 = 7.87 kNm
M2 = -34.43 kNm
34 - 12 x (M1/M2) = 36.74
17.58 < 36.74, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -233.1 kNm
M2 = 240.82 kNm
34 - 12 x (M1/M2) = 45.62
20.44 < 45.62, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -34.43 - -34.43
Major Axis Mux (bottom) 7.87 - 7.87
Minor Axis Muy (top) -233.1 - -233.1
Minor Axis Muy (bottom) 240.82 - 240.82

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1011.32 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 407 of 523

Mux = -34.43 kNm


Muy = -233.1 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 81.6 deg
MRes = 235.63 kNm
MCap = 322.82 kNm
Capacity Ratio = MRes/ MCap
= 0.73 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 482.32 kN
Muy = 130.63 kNm
Vuy = -87.8917 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 37.19 kNm
Vcy Permissible = 171.61 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 187.45 kN
Mux = 133.25 kNm
Vux = 90.7251 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 96.93 kNm
Vcx Permissible = 171.69 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 408 of 523

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C27
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 249
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 574.74 kN
Muxt = -52.71 kNm
Muyt = -246.87 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 409 of 523

Vuxt = -127.4 kN
Vuyt = 27.55 kN
Pub = 604.03 kN
Muxb = 43.7 kNm
Muyb = 198.93 kNm
Vuxb = -127.4 kN
Vuyb = 27.55 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 2250 x 350 x
Bottom 136.386 88.95 197.666 0.952
550 550
5000 x 350 x 2250 x 350 x
Top 136.386 88.95 197.666 0.952
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.77
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 410 of 523

0.018< 0.05, Column shall be designed as non-sway frame


(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.77
r = 144.34 mm
Kluy /r = 15.74
M1 = 43.7 kNm
M2 = -52.71 kNm
34 - 12 x (M1/M2) = 43.95
15.74 < 43.95, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 198.93 kNm
M2 = -246.87 kNm
34 - 12 x (M1/M2) = 43.67
20.44 < 43.67, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -52.71 - -52.71
Major Axis Mux (bottom) 43.7 - 43.7
Minor Axis Muy (top) -246.87 - -246.87
Minor Axis Muy (bottom) 198.93 - 198.93

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 574.74 kN
Mux = -52.71 kNm
Muy = -246.87 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 411 of 523

Load Angle = Tan-1(Muy/Mux)


= 77.95 deg
MRes = 252.43 kNm
MCap = 308.3 kNm
Capacity Ratio = MRes/ MCap
= 0.819 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 136.61 kN
Muy = 93.87 kNm
Vuy = 66.0472 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 67.4 kNm
Vcy Permissible = 171.91 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 283.26 kN
Mux = 138.78 kNm
Vux = -93.927 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 83.9 kNm
Vcx Permissible = 171.65 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 412 of 523

Criterion for spacing of normal


links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C27
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 372
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 155.14 kN
Muxt = 38.93 kNm
Muyt = -157.87 kNm
Vuxt = -75.79 kN
Vuyt = -10.14 kN
Pub = 184.43 kN
Muxb = 3.44 kNm
Muyb = 107.33 kNm
Vuxb = -75.79 kN
Vuyb = -10.14 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 413 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 2250 x 350 x
Bottom 136.386 88.95 197.666 0.952
550 550
5000 x 350 x
Top 136.386 No Beam 88.95 - 1.534
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.86
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.86
r = 144.34 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 414 of 523

Kluy /r = 17.58
M1 = 3.44 kNm
M2 = 38.93 kNm
34 - 12 x (M1/M2) = 32.94
17.58 < 32.94, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 107.33 kNm
M2 = -157.87 kNm
34 - 12 x (M1/M2) = 42.16
20.44 < 42.16, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 38.93 - 38.93
Major Axis Mux (bottom) 3.44 - 3.44
Minor Axis Muy (top) -157.87 - -157.87
Minor Axis Muy (bottom) 107.33 - 107.33

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 155.14 kN
Mux = 38.93 kNm
Muy = -157.87 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 76.15 deg
MRes = 162.6 kNm
MCap = 252.42 kNm
Capacity Ratio = MRes/ MCap
= 0.644 < 1

Design Of Shear

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 415 of 523

Design for shear along D


Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 210.72 kN
Muy = 1.7 kNm
Vuy = -18.9029 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 39.13 kNm
Vcy Permissible = 333.56 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 152.78 kN
Mux = 88.94 kNm
Vux = -64.8504 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 59.33 kNm
Vcx Permissible = 172.16 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 416 of 523

Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C28
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 82
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 1359.86 kN
Muxt = -23 kNm
Muyt = 12.59 kNm
Vuxt = -99.97 kN
Vuyt = 27.03 kN
Pub = 1374.92 kN
Muxb = 25.65 kNm
Muyb = 192.49 kNm
Vuxb = -99.97 kN
Vuyb = 27.03 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 417 of 523

Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam - 74.125 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -23 kNm
M2 = 25.65 kNm
34 - 12 x (M1/M2) = 44.76
7.53 < 44.76, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 418 of 523

Klux /r = 7.53
M1 = 12.59 kNm
M2 = 192.49 kNm
34 - 12 x (M1/M2) = 33.22
7.53 < 33.22, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -23 - -23
Major Axis Mux (bottom) 25.65 - 25.65
Minor Axis Muy (top) 12.59 - 12.59
Minor Axis Muy (bottom) 192.49 - 192.49

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1374.92 kN
Mux = 25.65 kNm
Muy = 192.49 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 82.41 deg
MRes = 194.19 kNm
MCap = 284.17 kNm
Capacity Ratio = MRes/ MCap
= 0.683 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 1024.44 kN
Muy = 196.49 kNm
Vuy = 146.1141 kN
λ = 1
φ = 0.65

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 419 of 523

deff = 450 mm
ρw = 0.006
mm = 1.99 kNm
Vcy Permissible = 442.33 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 666.41 kN
Mux = 190.93 kNm
Vux = -96.4568 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 61.81 kNm
Vcx Permissible = 169.96 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C28

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 420 of 523

Level : 1.8m To 5.3m


Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 128
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 365.08 kN
Muxt = 215.34 kNm
Muyt = -19.61 kNm
Vuxt = -6.88 kN
Vuyt = -128.97 kN
Pub = 379.1 kN
Muxb = -235.94 kNm
Muyb = 4.46 kNm
Vuxb = -6.88 kN
Vuyb = -128.97 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 421 of 523

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 5.409
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 215.34 kNm
M2 = -235.94 kNm
34 - 12 x (M1/M2) = 44.95
20.44 < 44.95, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 4.46 kNm
M2 = -19.61 kNm
34 - 12 x (M1/M2) = 36.73
20.44 < 36.73, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 422 of 523

A B C
Major Axis Mux (top) 215.34 - 215.34
Major Axis Mux (bottom) -235.94 - -235.94
Minor Axis Muy (top) -19.61 - -19.61
Minor Axis Muy (bottom) 4.46 - 4.46

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 379.1 kN
Mux = -235.94 kNm
Muy = 4.46 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 1.08 deg
MRes = 235.99 kNm
MCap = 290.79 kNm
Capacity Ratio = MRes/ MCap
= 0.812 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 844.24 kN
Muy = 209.09 kNm
Vuy = 126.7172 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 45.52 kNm
Vcy Permissible = 170.95 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 423 of 523

[22] : 0.68 (LOAD 3: DL) -1.25


Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 249.52 kN
Mux = 110.44 kNm
Vux = 79.4331 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 62.09 kNm
Vcx Permissible = 172.07 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C28
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 424 of 523

Clear Floor Height @ luy = 2950 mm


No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 251
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 620.01 kN
Muxt = 212.43 kNm
Muyt = -80.14 kNm
Vuxt = -50.08 kN
Vuyt = -113.69 kN
Pub = 649.29 kN
Muxb = -185.36 kNm
Muyb = 95.11 kNm
Vuxb = -50.08 kN
Vuyb = -113.69 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 425 of 523

Top 136.386 No Beam 550 - 74.125 3.674


Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -185.36 kNm
M2 = 212.43 kNm
34 - 12 x (M1/M2) = 44.47
20.44 < 44.47, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -80.14 kNm
M2 = 95.11 kNm
34 - 12 x (M1/M2) = 44.11
20.44 < 44.11, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 212.43 - 212.43
Major Axis Mux (bottom) -185.36 - -185.36
Minor Axis Muy (top) -80.14 - -80.14
Minor Axis Muy (bottom) 95.11 - 95.11

Where
A = Moments from analysis
B = Moment due to slenderness effect

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 426 of 523

C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 620.01 kN
Mux = 212.43 kNm
Muy = -80.14 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 20.67 deg
MRes = 227.05 kNm
MCap = 297.99 kNm
Capacity Ratio = MRes/ MCap
= 0.762 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 1: EX)
Nu = 673.65 kN
Muy = 141.31 kNm
Vuy = 88.9918 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 10.79 kNm
Vcy Permissible = 171.18 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 327.99 kN
Mux = 120.11 kNm
Vux = -82.3054 kN
λ = 1
φ = 0.65
deff = 450 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 427 of 523

ρw = 0.006
mm = 56.56 kNm
Vcx Permissible = 171.73 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C28
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 374
Critical Analysis Load Combination : 16

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 428 of 523

[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25


Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 278.88 kN
Muxt = 4.92 kNm
Muyt = -203.64 kNm
Vuxt = -93.1 kN
Vuyt = -4.57 kN
Pub = 308.17 kN
Muxb = -11.08 kNm
Muyb = 122.13 kNm
Vuxb = -93.1 kN
Vuyb = -4.57 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 429 of 523

       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = 4.92 kNm
M2 = -11.08 kNm
34 - 12 x (M1/M2) = 39.33
17.37 < 39.33, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 122.13 kNm
M2 = -203.64 kNm
34 - 12 x (M1/M2) = 41.2
20.44 < 41.2, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 4.92 - 4.92
Major Axis Mux (bottom) -11.08 - -11.08
Minor Axis Muy (top) -203.64 - -203.64
Minor Axis Muy (bottom) 122.13 - 122.13

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 278.88 kN
Mux = 4.92 kNm
Muy = -203.64 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 430 of 523

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 88.62 deg
MRes = 203.69 kNm
MCap = 275.36 kNm
Capacity Ratio = MRes/ MCap
= 0.74 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 213.12 kN
Muy = 80.46 kNm
Vuy = -56.838 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 39.17 kNm
Vcy Permissible = 171.94 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 242.21 kN
Mux = 96.55 kNm
Vux = -75.3958 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 49.62 kNm
Vcx Permissible = 172.68 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 431 of 523

Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C29
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 84
Critical Analysis Load Combination : 26
Load Combination = [22] : 0.68 (LOAD 3: DL) -1.25 (LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 253.18 kN
Muxt = 5.18 kNm
Muyt = -22.56 kNm
Vuxt = 85.85 kN
Vuyt = -14.79 kN
Pub = 260.4 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 432 of 523

Muxb = -21.45 kNm


Muyb = -177.04 kNm
Vuxb = 85.85 kN
Vuyb = -14.79 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam - 74.125 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 433 of 523

Slenderness Check along D


K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 5.18 kNm
M2 = -21.45 kNm
34 - 12 x (M1/M2) = 36.9
7.53 < 36.9, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = -22.56 kNm
M2 = -177.04 kNm
34 - 12 x (M1/M2) = 32.47
7.53 < 32.47, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 5.18 - 5.18
Major Axis Mux (bottom) -21.45 - -21.45
Minor Axis Muy (top) -22.56 - -22.56
Minor Axis Muy (bottom) -177.04 - -177.04

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 260.4 kN
Mux = -21.45 kNm
Muy = -177.04 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 83.09 deg
MRes = 178.33 kNm
MCap = 270.08 kNm
Capacity Ratio = MRes/ MCap

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 434 of 523

= 0.66 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 443.25 kN
Muy = 47.5 kNm
Vuy = 131.7054 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 38.38 kNm
Vcy Permissible = 367.94 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 741.52 kN
Mux = 178 kNm
Vux = 87.5586 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 34.33 kNm
Vcx Permissible = 169.82 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 435 of 523

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C29
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 130
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 390.24 kN
Muxt = 210.39 kNm
Muyt = -21.78 kNm
Vuxt = -7.43 kN
Vuyt = -127.41 kN
Pub = 404.27 kN
Muxb = -235.42 kNm
Muyb = 4.23 kNm
Vuxb = -7.43 kN
Vuyb = -127.41 kN

Effective Length Calculation


Calculation Along Major Axis Of Column

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 436 of 523

Joint Column Beam Sizes Beam Stiffness Beta


Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 5.409
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 210.39 kNm
M2 = -235.42 kNm
34 - 12 x (M1/M2) = 44.72
20.44 < 44.72, Column not slender along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 437 of 523

Column Is Braced Along B


Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 4.23 kNm
M2 = -21.78 kNm
34 - 12 x (M1/M2) = 36.33
20.44 < 36.33, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 210.39 - 210.39
Major Axis Mux (bottom) -235.42 - -235.42
Minor Axis Muy (top) -21.78 - -21.78
Minor Axis Muy (bottom) 4.23 - 4.23

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 404.27 kN
Mux = -235.42 kNm
Muy = 4.23 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 1.03 deg
MRes = 235.46 kNm
MCap = 294.61 kNm
Capacity Ratio = MRes/ MCap
= 0.799 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 1017.5 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 438 of 523

Muy = 213.97 kNm


Vuy = -130.2128 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 16.83 kNm
Vcy Permissible = 170.98 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 261.78 kN
Mux = 102.75 kNm
Vux = 75.4585 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 52.03 kNm
Vcx Permissible = 172.22 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 439 of 523

General Data
Column No. : C29
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 253
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 633.65 kN
Muxt = 201.7 kNm
Muyt = -84.43 kNm
Vuxt = -52.99 kN
Vuyt = -107.22 kN
Pub = 662.94 kN
Muxb = -173.46 kNm
Muyb = 100.99 kNm
Vuxb = -52.99 kN
Vuyb = -107.22 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 440 of 523

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -173.46 kNm
M2 = 201.7 kNm
34 - 12 x (M1/M2) = 44.32
20.44 < 44.32, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -84.43 kNm
M2 = 100.99 kNm
34 - 12 x (M1/M2) = 44.03

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 441 of 523

20.44 < 44.03, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 201.7 - 201.7
Major Axis Mux (bottom) -173.46 - -173.46
Minor Axis Muy (top) -84.43 - -84.43
Minor Axis Muy (bottom) 100.99 - 100.99

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 633.65 kN
Mux = 201.7 kNm
Muy = -84.43 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 22.71 deg
MRes = 218.65 kNm
MCap = 294.1 kNm
Capacity Ratio = MRes/ MCap
= 0.743 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 1: EX)
Nu = 670.33 kN
Muy = 143.87 kNm
Vuy = 91.1198 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 14 kNm
Vcy Permissible = 171.22 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 442 of 523

Vuy < Vcy Permissible


Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 326.26 kN
Mux = 117.22 kNm
Vux = -79.2681 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 54.01 kNm
Vcx Permissible = 171.64 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C29
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 443 of 523

Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 376
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 271.51 kN
Muxt = 7.57 kNm
Muyt = -205.05 kNm
Vuxt = -94.18 kN
Vuyt = -4.4 kN
Pub = 300.79 kN
Muxb = -7.83 kNm
Muyb = 124.47 kNm
Vuxb = -94.18 kN
Vuyb = -4.4 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 444 of 523

(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = 7.57 kNm
M2 = -7.83 kNm
34 - 12 x (M1/M2) = 45.6
17.37 < 45.6, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 124.47 kNm
M2 = -205.05 kNm
34 - 12 x (M1/M2) = 41.28
20.44 < 41.28, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 7.57 - 7.57
Major Axis Mux (bottom) -7.83 - -7.83

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 445 of 523

Minor Axis Muy (top) -205.05 - -205.05


Minor Axis Muy (bottom) 124.47 - 124.47

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 271.51 kN
Mux = 7.57 kNm
Muy = -205.05 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.89 deg
MRes = 205.19 kNm
MCap = 273.52 kNm
Capacity Ratio = MRes/ MCap
= 0.75 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 276.37 kN
Muy = 79.81 kNm
Vuy = -57.8933 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 26.27 kNm
Vcy Permissible = 172.13 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 446 of 523

Nu = 236.38 kN
Mux = 98.16 kNm
Vux = -75.8888 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 52.36 kNm
Vcx Permissible = 172.6 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C30
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 447 of 523

No Of Columns In Group = 1

Load Data
Analysis Reference No. = 86
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 431.72 kN
Muxt = 46.08 kNm
Muyt = 1.53 kNm
Vuxt = 3.29 kN
Vuyt = -131.66 kN
Pub = 438.93 kN
Muxb = -190.84 kNm
Muyb = -4.39 kNm
Vuxb = 3.29 kN
Vuyb = -131.66 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam - 74.125 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)

Effective Length Factor along Minor = 0.87

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 448 of 523

axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 46.08 kNm
M2 = -190.84 kNm
34 - 12 x (M1/M2) = 36.9
7.53 < 36.9, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 1.53 kNm
M2 = -4.39 kNm
34 - 12 x (M1/M2) = 38.19
7.53 < 38.19, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 46.08 - 46.08
Major Axis Mux (bottom) -190.84 - -190.84
Minor Axis Muy (top) 1.53 - 1.53
Minor Axis Muy (bottom) -4.39 - -4.39

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 449 of 523

Critical Case - Axial Load & BiAxial Bending


Pu = 438.93 kN
Mux = -190.84 kNm
Muy = -4.39 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 1.32 deg
MRes = 190.89 kNm
MCap = 299.68 kNm
Capacity Ratio = MRes/ MCap
= 0.637 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 439.67 kN
Muy = 48.52 kNm
Vuy = 132.5124 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 36.67 kNm
Vcy Permissible = 367.44 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 22
[18] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 753.66 kN
Mux = 165.84 kNm
Vux = 81.7118 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 19.82 kNm
Vcx Permissible = 169.83 kN
Vux < Vcx Permissible

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 450 of 523

Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C30
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 132
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 394.11 kN
Muxt = 210.86 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 451 of 523

Muyt = -25.48 kNm


Vuxt = -9.97 kN
Vuyt = -127.51 kN
Pub = 408.13 kN
Muxb = -235.3 kNm
Muyb = 9.42 kNm
Vuxb = -9.97 kN
Vuyb = -127.51 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 5.409
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 452 of 523

       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 210.86 kNm
M2 = -235.3 kNm
34 - 12 x (M1/M2) = 44.75
20.44 < 44.75, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 9.42 kNm
M2 = -25.48 kNm
34 - 12 x (M1/M2) = 38.43
20.44 < 38.43, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 210.86 - 210.86
Major Axis Mux (bottom) -235.3 - -235.3
Minor Axis Muy (top) -25.48 - -25.48
Minor Axis Muy (bottom) 9.42 - 9.42

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 408.13 kN
Mux = -235.3 kNm
Muy = 9.42 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 453 of 523

Load Angle = Tan-1(Muy/Mux)


= 2.29 deg
MRes = 235.49 kNm
MCap = 294.43 kNm
Capacity Ratio = MRes/ MCap
= 0.8 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 1022.26 kN
Muy = 214.6 kNm
Vuy = -130.256 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 16.53 kNm
Vcy Permissible = 170.96 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 269.82 kN
Mux = 93.78 kNm
Vux = 69.5921 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 41.5 kNm
Vcx Permissible = 172.29 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 454 of 523

Criterion for spacing of normal


links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C30
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 255
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 637.44 kN
Muxt = 203.09 kNm
Muyt = -88.44 kNm
Vuxt = -55.13 kN
Vuyt = -108.05 kN
Pub = 666.73 kN
Muxb = -174.98 kNm
Muyb = 104.45 kNm
Vuxb = -55.13 kN
Vuyb = -108.05 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 455 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 456 of 523

Kluy /r = 20.44
M1 = -174.98 kNm
M2 = 203.09 kNm
34 - 12 x (M1/M2) = 44.34
20.44 < 44.34, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -88.44 kNm
M2 = 104.45 kNm
34 - 12 x (M1/M2) = 44.16
20.44 < 44.16, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 203.09 - 203.09
Major Axis Mux (bottom) -174.98 - -174.98
Minor Axis Muy (top) -88.44 - -88.44
Minor Axis Muy (bottom) 104.45 - 104.45

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 637.44 kN
Mux = 203.09 kNm
Muy = -88.44 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 23.53 deg
MRes = 221.51 kNm
MCap = 292.49 kNm
Capacity Ratio = MRes/ MCap
= 0.757 < 1

Design Of Shear

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 457 of 523

Design for shear along D


Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 1: EX)
Nu = 669.8 kN
Muy = 142.84 kNm
Vuy = 90.4526 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 13.07 kNm
Vcy Permissible = 171.22 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 323.39 kN
Mux = 113.6 kNm
Vux = -76.0543 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 50.94 kNm
Vcx Permissible = 171.58 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 458 of 523

Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C30
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 378
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 271.91 kN
Muxt = 7.17 kNm
Muyt = -204.45 kNm
Vuxt = -94.69 kN
Vuyt = -4.45 kN
Pub = 301.19 kN
Muxb = -8.39 kNm
Muyb = 126.87 kNm
Vuxb = -94.69 kN
Vuyb = -4.45 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 459 of 523

Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = 7.17 kNm
M2 = -8.39 kNm
34 - 12 x (M1/M2) = 44.24
17.37 < 44.24, Column not slender along D
Column Is Braced Along B
Slenderness Check along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 460 of 523

K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 126.87 kNm
M2 = -204.45 kNm
34 - 12 x (M1/M2) = 41.45
20.44 < 41.45, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 7.17 - 7.17
Major Axis Mux (bottom) -8.39 - -8.39
Minor Axis Muy (top) -204.45 - -204.45
Minor Axis Muy (bottom) 126.87 - 126.87

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 271.91 kN
Mux = 7.17 kNm
Muy = -204.45 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 87.99 deg
MRes = 204.58 kNm
MCap = 273.65 kNm
Capacity Ratio = MRes/ MCap
= 0.748 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 213.77 kN
Muy = 77.14 kNm
Vuy = -55.9471 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 461 of 523

λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 35.72 kNm
Vcy Permissible = 172.13 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 236.47 kN
Mux = 99.99 kNm
Vux = -76.0609 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 54.17 kNm
Vcx Permissible = 172.48 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 462 of 523

General Data
Column No. : C31
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 88
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 472.92 kN
Muxt = 52.17 kNm
Muyt = -8.02 kNm
Vuxt = -7.34 kN
Vuyt = -136.48 kN
Pub = 480.13 kN
Muxb = -193.43 kNm
Muyb = 5.18 kNm
Vuxb = -7.34 kN
Vuyb = -136.48 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)

Effective Length Factor along Major = 0.87

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 463 of 523

Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam - 74.125 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 52.17 kNm
M2 = -193.43 kNm
34 - 12 x (M1/M2) = 37.24
7.53 < 37.24, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 5.18 kNm
M2 = -8.02 kNm
34 - 12 x (M1/M2) = 41.75
7.53 < 41.75, Column not slender along B

Calculation of Design Moment

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 464 of 523

Direction Manalysis Msldr or Mc Mdesign-final


A B C
Major Axis Mux (top) 52.17 - 52.17
Major Axis Mux (bottom) -193.43 - -193.43
Minor Axis Muy (top) -8.02 - -8.02
Minor Axis Muy (bottom) 5.18 - 5.18

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 480.13 kN
Mux = -193.43 kNm
Muy = 5.18 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 1.53 deg
MRes = 193.49 kNm
MCap = 305.49 kNm
Capacity Ratio = MRes/ MCap
= 0.633 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 472.92 kN
Muy = 52.17 kNm
Vuy = -136.4806 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 39.45 kNm
Vcy Permissible = 372.1 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 465 of 523

Critical Analysis Load Combination : 24


[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 639.76 kN
Mux = 157.26 kNm
Vux = -79.9763 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 33.31 kNm
Vcx Permissible = 169.99 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C31
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 466 of 523

Clear Floor Height @ lux = 2950 mm


Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 134
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 399.09 kN
Muxt = 211.99 kNm
Muyt = -30.95 kNm
Vuxt = -14.54 kN
Vuyt = -128.75 kN
Pub = 413.12 kN
Muxb = -238.51 kNm
Muyb = 19.94 kNm
Vuxb = -14.54 kN
Vuyb = -128.75 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 5.409
550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 467 of 523

6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 211.99 kNm
M2 = -238.51 kNm
34 - 12 x (M1/M2) = 44.67
20.44 < 44.67, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 19.94 kNm
M2 = -30.95 kNm
34 - 12 x (M1/M2) = 41.73
20.44 < 41.73, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 211.99 - 211.99
Major Axis Mux (bottom) -238.51 - -238.51
Minor Axis Muy (top) -30.95 - -30.95
Minor Axis Muy (bottom) 19.94 - 19.94

Where
A = Moments from analysis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 468 of 523

B = Moment due to slenderness effect


C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 413.12 kN
Mux = -238.51 kNm
Muy = 19.94 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 4.78 deg
MRes = 239.35 kNm
MCap = 293.68 kNm
Capacity Ratio = MRes/ MCap
= 0.815 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 1029.62 kN
Muy = 217.19 kNm
Vuy = -132.9366 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 17.7 kNm
Vcy Permissible = 171.01 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 278.4 kN
Mux = 83.06 kNm
Vux = 61.6999 kN
λ = 1
φ = 0.65

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 469 of 523

deff = 450 mm
ρw = 0.006
mm = 29.12 kNm
Vcx Permissible = 172.3 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C31
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 257

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 470 of 523

Critical Analysis Load Combination : 17


[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 642.13 kN
Muxt = 201.43 kNm
Muyt = -91.66 kNm
Vuxt = -56.45 kN
Vuyt = -107.16 kN
Pub = 671.42 kN
Muxb = -173.53 kNm
Muyb = 105.86 kNm
Vuxb = -56.45 kN
Vuyb = -107.16 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 471 of 523

Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -173.53 kNm
M2 = 201.43 kNm
34 - 12 x (M1/M2) = 44.34
20.44 < 44.34, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -91.66 kNm
M2 = 105.86 kNm
34 - 12 x (M1/M2) = 44.39
20.44 < 44.39, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 201.43 - 201.43
Major Axis Mux (bottom) -173.53 - -173.53
Minor Axis Muy (top) -91.66 - -91.66
Minor Axis Muy (bottom) 105.86 - 105.86

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 642.13 kN
Mux = 201.43 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 472 of 523

Muy = -91.66 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 24.47 deg
MRes = 221.31 kNm
MCap = 290.57 kNm
Capacity Ratio = MRes/ MCap
= 0.762 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 15
[11] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 1: EX)
Nu = 670.12 kN
Muy = 144.12 kNm
Vuy = 91.2791 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 14.29 kNm
Vcy Permissible = 171.22 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 320.62 kN
Mux = 109.01 kNm
Vux = -72.4587 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 46.89 kNm
Vcx Permissible = 171.53 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 473 of 523

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C31
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 380
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 274.5 kN
Muxt = 9.23 kNm
Muyt = -203.6 kNm
Vuxt = -95.15 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 474 of 523

Vuyt = -5.04 kN
Pub = 303.79 kN
Muxb = -8.39 kNm
Muyb = 129.33 kNm
Vuxb = -95.15 kN
Vuyb = -5.04 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009

0.009< 0.05, Column shall be designed as non-sway frame

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 475 of 523

(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = -8.39 kNm
M2 = 9.23 kNm
34 - 12 x (M1/M2) = 44.92
17.37 < 44.92, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 129.33 kNm
M2 = -203.6 kNm
34 - 12 x (M1/M2) = 41.62
20.44 < 41.62, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 9.23 - 9.23
Major Axis Mux (bottom) -8.39 - -8.39
Minor Axis Muy (top) -203.6 - -203.6
Minor Axis Muy (bottom) 129.33 - 129.33

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 274.5 kN
Mux = 9.23 kNm
Muy = -203.6 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 476 of 523

= 87.41 deg
MRes = 203.81 kNm
MCap = 273.67 kNm
Capacity Ratio = MRes/ MCap
= 0.745 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 21
[17] : 1.42 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 217.21 kN
Muy = 77.31 kNm
Vuy = -56.4778 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 35.22 kNm
Vcy Permissible = 172.18 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 237.97 kN
Mux = 101.9 kNm
Vux = -76.1931 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 55.79 kNm
Vcx Permissible = 172.35 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm

Criterion for spacing of normal

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 477 of 523

links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C32
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 90
Critical Analysis Load Combination : 23
Load Combination = [19] : 0.68 (LOAD 3: DL) +1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 443.52 kN
Muxt = -49.17 kNm
Muyt = 1.23 kNm
Vuxt = 3.94 kN
Vuyt = 133.02 kN
Pub = 450.74 kN
Muxb = 190.21 kNm
Muyb = -5.87 kNm
Vuxb = 3.94 kN
Vuyb = 133.02 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 478 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
5000 x 350 x 5000 x 350 x
Top 265.195 88.95 88.95 2.259
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam - 74.125 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -49.17 kNm
M2 = 190.21 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 479 of 523

34 - 12 x (M1/M2) = 37.1
7.53 < 37.1, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = 1.23 kNm
M2 = -5.87 kNm
34 - 12 x (M1/M2) = 36.51
7.53 < 36.51, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -49.17 - -49.17
Major Axis Mux (bottom) 190.21 - 190.21
Minor Axis Muy (top) 1.23 - 1.23
Minor Axis Muy (bottom) -5.87 - -5.87

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 450.74 kN
Mux = 190.21 kNm
Muy = -5.87 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 1.77 deg
MRes = 190.3 kNm
MCap = 301.24 kNm
Capacity Ratio = MRes/ MCap
= 0.632 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25

[21] : 0.68 (LOAD 3: DL) -1.25

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 480 of 523

Critical Load Combination = (LOAD 1: EX) kN


Nu = 468.3 kN
Muy = 47.71 kNm
Vuy = -132.9435 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 43.03 kNm
Vcy Permissible = 371.45 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 315.1 kN
Mux = 141.55 kNm
Vux = 68.653 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 80.5 kNm
Vcx Permissible = 169.76 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 481 of 523

General Data
Column No. : C32
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 136
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 392.83 kN
Muxt = 210.28 kNm
Muyt = -33.04 kNm
Vuxt = -15.13 kN
Vuyt = -127.47 kN
Pub = 406.86 kN
Muxb = -235.74 kNm
Muyb = 19.9 kNm
Vuxb = -15.13 kN
Vuyb = -127.47 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 2.259
550 550
5000 x 350 x 5000 x 350 x

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 482 of 523

Top 136.386 550 550 88.95 88.95 1.534


Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 5.409
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 210.28 kNm
M2 = -235.74 kNm
34 - 12 x (M1/M2) = 44.7
20.44 < 44.7, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 19.9 kNm
M2 = -33.04 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 483 of 523

34 - 12 x (M1/M2) = 41.23
20.44 < 41.23, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 210.28 - 210.28
Major Axis Mux (bottom) -235.74 - -235.74
Minor Axis Muy (top) -33.04 - -33.04
Minor Axis Muy (bottom) 19.9 - 19.9

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 406.86 kN
Mux = -235.74 kNm
Muy = 19.9 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 4.83 deg
MRes = 236.57 kNm
MCap = 292.78 kNm
Capacity Ratio = MRes/ MCap
= 0.808 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 998.07 kN
Muy = 210.87 kNm
Vuy = -129.0537 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 17.49 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 484 of 523

Vcy Permissible = 171.01 kN


Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 273.5 kN
Mux = 75.94 kNm
Vux = 57.8881 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 22.95 kNm
Vcx Permissible = 172.49 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C32
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 485 of 523

Grade Of Steel = Fy420 N/sqmm


Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 259
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 616.2 kN
Muxt = 204.58 kNm
Muyt = -96.21 kNm
Vuxt = -59.33 kN
Vuyt = -107.68 kN
Pub = 645.48 kN
Muxb = -172.2 kNm
Muyb = 111.38 kNm
Vuxb = -59.33 kN
Vuyb = -107.68 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 1.534
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 486 of 523

Stiffness Beam 1 Beam 2 Beam 1 Beam 2


(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -172.2 kNm
M2 = 204.58 kNm
34 - 12 x (M1/M2) = 44.1
20.44 < 44.1, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -96.21 kNm
M2 = 111.38 kNm
34 - 12 x (M1/M2) = 44.37
20.44 < 44.37, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 204.58 - 204.58

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 487 of 523

Major Axis Mux (bottom) -172.2 - -172.2


Minor Axis Muy (top) -96.21 - -96.21
Minor Axis Muy (bottom) 111.38 - 111.38

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 616.2 kN
Mux = 204.58 kNm
Muy = -96.21 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 25.19 deg
MRes = 226.08 kNm
MCap = 288.78 kNm
Capacity Ratio = MRes/ MCap
= 0.783 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) -1.25 (LOAD 1: EX)
Nu = 645.48 kN
Muy = 172.2 kNm
Vuy = -107.6804 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 47.13 kNm
Vcy Permissible = 171.14 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 488 of 523

Nu = 306.29 kN
Mux = 106.63 kNm
Vux = -69.7361 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 47.29 kNm
Vcx Permissible = 171.42 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C32
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 489 of 523

No Of Columns In Group = 1

Load Data
Analysis Reference No. = 382
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 243 kN
Muxt = -11.45 kNm
Muyt = -203.71 kNm
Vuxt = -95.85 kN
Vuyt = 2.68 kN
Pub = 272.29 kN
Muxb = -2.07 kNm
Muyb = 131.68 kNm
Vuxb = -95.85 kN
Vuyb = 2.68 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
5000 x 350 x 5000 x 350 x
Bottom 136.386 88.95 88.95 1.534
550 550
5000 x 350 x 5000 x 350 x
Top 136.386 88.95 88.95 0.767
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.85
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 1.837
550
Sway Condition (as per Stability

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 490 of 523

Index) = Non Sway


Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.85
r = 144.34 mm
Kluy /r = 17.37
M1 = -2.07 kNm
M2 = -11.45 kNm
34 - 12 x (M1/M2) = 31.84
17.37 < 31.84, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 131.68 kNm
M2 = -203.71 kNm
34 - 12 x (M1/M2) = 41.76
20.44 < 41.76, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -11.45 - -11.45
Major Axis Mux (bottom) -2.07 - -2.07
Minor Axis Muy (top) -203.71 - -203.71
Minor Axis Muy (bottom) 131.68 - 131.68

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 491 of 523

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 243 kN
Mux = -11.45 kNm
Muy = -203.71 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 86.78 deg
MRes = 204.03 kNm
MCap = 268.3 kNm
Capacity Ratio = MRes/ MCap
= 0.76 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 14
[10] : 1.2 (LOAD 3: DL) +1.6 (LOAD
Critical Load Combination = kN
4: LL)
Nu = 348.9 kN
Muy = 9.39 kNm
Vuy = -1.1018 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 58.21 kNm
Vcy Permissible = 354.39 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 214.71 kN
Mux = 103.62 kNm
Vux = -76.4879 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 62.03 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 492 of 523

Vcx Permissible = 172.25 kN


Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C33
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 92
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 493 of 523

Critical Location = Bottom Joint


Put = 1369.73 kN
Muxt = 24.08 kNm
Muyt = -11.61 kNm
Vuxt = -17.33 kN
Vuyt = -115.03 kN
Pub = 1384.79 kN
Muxb = -182.92 kNm
Muyb = 19.57 kNm
Vuxb = -17.33 kN
Vuyb = -115.03 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
10000 x 350 x 5000 x 350 x
Top 265.195 44.475 88.95 3.011
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam - 74.125 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 494 of 523

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = 24.08 kNm
M2 = -182.92 kNm
34 - 12 x (M1/M2) = 35.58
7.53 < 35.58, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = -11.61 kNm
M2 = 19.57 kNm
34 - 12 x (M1/M2) = 41.12
7.53 < 41.12, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 24.08 - 24.08
Major Axis Mux (bottom) -182.92 - -182.92
Minor Axis Muy (top) -11.61 - -11.61
Minor Axis Muy (bottom) 19.57 - 19.57

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1384.79 kN
Mux = -182.92 kNm
Muy = 19.57 kNm

Moment Capacity Check

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 495 of 523

Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 6.11 deg
MRes = 183.97 kNm
MCap = 285.36 kNm
Capacity Ratio = MRes/ MCap
= 0.645 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 468.58 kN
Muy = 182.48 kNm
Vuy = -116.0653 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 91.69 kNm
Vcy Permissible = 171.25 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 26
[22] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 423.21 kN
Mux = 126.2 kNm
Vux = 56.3588 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 44.2 kNm
Vcx Permissible = 169.38 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 496 of 523

> Max. longitudinal bar dia / 4


= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C33
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 138
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Top Joint
Put = 1227.29 kN
Muxt = 258.83 kNm
Muyt = -89.44 kNm
Vuxt = -42.64 kN
Vuyt = -146.44 kN
Pub = 1256.58 kN
Muxb = -253.59 kNm
Muyb = 59.76 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 497 of 523

Vuxb = -42.64 kN
Vuyb = -146.44 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
10000 x 350 x 5000 x 350 x
Bottom 136.386 44.475 88.95 3.011
550 550
10000 x 350 x 5000 x 350 x
Top 136.386 44.475 88.95 2.045
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 5.409
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 498 of 523

Slenderness Check along D


K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -253.59 kNm
M2 = 258.83 kNm
34 - 12 x (M1/M2) = 45.76
20.44 < 45.76, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 59.76 kNm
M2 = -89.44 kNm
34 - 12 x (M1/M2) = 42.02
20.44 < 42.02, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 258.83 - 258.83
Major Axis Mux (bottom) -253.59 - -253.59
Minor Axis Muy (top) -89.44 - -89.44
Minor Axis Muy (bottom) 59.76 - 59.76

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 1227.29 kN
Mux = 258.83 kNm
Muy = -89.44 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 19.06 deg
MRes = 273.84 kNm
MCap = 280.09 kNm
Capacity Ratio = MRes/ MCap

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 499 of 523

= 0.978 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 590.22 kN
Muy = 153.8 kNm
Vuy = 98.7017 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 39.45 kNm
Vcy Permissible = 171.3 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 629.91 kN
Mux = 135.69 kNm
Vux = -83.0553 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 13.65 kNm
Vcx Permissible = 171.01 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 500 of 523

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C33
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 261
Critical Analysis Load Combination : 17
[13] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) -1.25
Load Combination =
(LOAD 1: EX)
Critical Location = Bottom Joint
Put = 815.17 kN
Muxt = 245.07 kNm
Muyt = -97.41 kNm
Vuxt = -59.62 kN
Vuyt = -136.74 kN
Pub = 844.45 kN
Muxb = -233.39 kNm
Muyb = 111.21 kNm
Vuxb = -59.62 kN
Vuyb = -136.74 kN

Effective Length Calculation

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 501 of 523

Calculation Along Major Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
10000 x 350 x 5000 x 350 x
Bottom 136.386 44.475 88.95 2.045
550 550
10000 x 350 x 5000 x 350 x
Top 136.386 44.475 88.95 2.045
550 550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -233.39 kNm
M2 = 245.07 kNm
34 - 12 x (M1/M2) = 45.43

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 502 of 523

20.44 < 45.43, Column not slender along D


Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -97.41 kNm
M2 = 111.21 kNm
34 - 12 x (M1/M2) = 44.51
20.44 < 44.51, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 245.07 - 245.07
Major Axis Mux (bottom) -233.39 - -233.39
Minor Axis Muy (top) -97.41 - -97.41
Minor Axis Muy (bottom) 111.21 - 111.21

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 844.45 kN
Mux = -233.39 kNm
Muy = 111.21 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 25.48 deg
MRes = 258.53 kNm
MCap = 287.86 kNm
Capacity Ratio = MRes/ MCap
= 0.898 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 503 of 523

Nu = 378.88 kN
Muy = 95.36 kNm
Vuy = 65.9821 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 21.96 kNm
Vcy Permissible = 171.8 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 402.51 kN
Mux = 113.11 kNm
Vux = -71.9592 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 35.12 kNm
Vcx Permissible = 171.25 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 504 of 523

General Data
Column No. : C33
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 384
Critical Analysis Load Combination : 14
Load Combination = [10] : 1.2 (LOAD 3: DL) +1.6 (LOAD 4: LL)
Critical Location = Top Joint
Put = 593.13 kN
Muxt = 305.82 kNm
Muyt = -229.62 kNm
Vuxt = -112.76 kN
Vuyt = -140.51 kN
Pub = 617.88 kN
Muxb = -185.83 kNm
Muyb = 164.95 kNm
Vuxb = -112.76 kN
Vuyb = -140.51 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
10000 x 350 x 5000 x 350 x
Bottom 136.386 44.475 88.95 2.045
550 550
10000 x 350 x 5000 x 350 x
Top 136.386 44.475 88.95 1.023
550 550

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 505 of 523

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -185.83 kNm
M2 = 305.82 kNm
34 - 12 x (M1/M2) = 41.29
20.44 < 41.29, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 164.95 kNm
M2 = -229.62 kNm
34 - 12 x (M1/M2) = 42.62

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 506 of 523

20.44 < 42.62, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 305.82 - 305.82
Major Axis Mux (bottom) -185.83 - -185.83
Minor Axis Muy (top) -229.62 - -229.62
Minor Axis Muy (bottom) 164.95 - 164.95

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 593.13 kN
Mux = 305.82 kNm
Muy = -229.62 kNm

Moment Capacity Check


Pt Calculated = 2.86
Reinforcement Provided = 4-#32 + 8-#25
Load Angle = Tan-1(Muy/Mux)
= 36.9 deg
MRes = 382.43 kNm
MCap = 414.51 kNm
Capacity Ratio = MRes/ MCap
= 0.923 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 25
[21] : 0.68 (LOAD 3: DL) -1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 146.44 kN
Muy = 97.6 kNm
Vuy = -75.8009 kN
λ = 1
φ = 0.65
deff = 444 mm
ρw = 0.014
mm = 69.12 kNm
Vcy Permissible = 181.37 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 507 of 523

Vuy < Vcy Permissible


Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 20
[16] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 352.03 kN
Mux = 114.05 kNm
Vux = -81.9144 kN
λ = 1
φ = 0.65
deff = 444 mm
ρw = 0.014
mm = 45.58 kNm
Vcx Permissible = 179.97 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 8 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 400 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C34
Level : 0m To 1.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 508 of 523

Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 1250 mm
Clear Floor Height @ luy = 1250 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 96
Critical Analysis Load Combination : 25
Load Combination = [21] : 0.68 (LOAD 3: DL) -1.25 (LOAD 1: EX)
Critical Location = Bottom Joint
Put = 354.33 kN
Muxt = -55.51 kNm
Muyt = -8.65 kNm
Vuxt = -20.09 kN
Vuyt = -51.25 kN
Pub = 361.54 kN
Muxb = -147.73 kNm
Muyb = 27.51 kNm
Vuxb = -20.09 kN
Vuyb = -51.25 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
10000 x 350 x
Top 265.195 No Beam - 44.475 9.034
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 509 of 523

Depth) Depth)
N-M mm mm N-M N-M
Bottom 265.195 No Beam No Beam - - 1
6000 x 350 x
Top 265.195 No Beam - 74.125 5.409
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 144.34 mm
Kluy /r = 7.53
M1 = -55.51 kNm
M2 = -147.73 kNm
34 - 12 x (M1/M2) = 29.49
7.53 < 29.49, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 144.34 mm
Klux /r = 7.53
M1 = -8.65 kNm
M2 = 27.51 kNm
34 - 12 x (M1/M2) = 37.77
7.53 < 37.77, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -55.51 - -55.51
Major Axis Mux (bottom) -147.73 - -147.73
Minor Axis Muy (top) -8.65 - -8.65
Minor Axis Muy (bottom) 27.51 - 27.51

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 510 of 523

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 361.54 kN
Mux = -147.73 kNm
Muy = 27.51 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 10.55 deg
MRes = 150.27 kNm
MCap = 284.23 kNm
Capacity Ratio = MRes/ MCap
= 0.529 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 449.3 kN
Muy = 155.25 kNm
Vuy = 67.8143 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 68.2 kNm
Vcy Permissible = 169.28 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 546.38 kN
Mux = 114.66 kNm
Vux = -62.2859 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 511 of 523

λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 8.8 kNm
Vcx Permissible = 170.33 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C34
Level : 1.8m To 5.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 512 of 523

Load Data
Analysis Reference No. = 142
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Top Joint
Put = 970.49 kN
Muxt = -138.22 kNm
Muyt = -142.28 kNm
Vuxt = -84.66 kN
Vuyt = 61.46 kN
Pub = 999.77 kN
Muxb = 76.85 kNm
Muyb = 153.95 kNm
Vuxb = -84.66 kN
Vuyb = 61.46 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
10000 x 350 x
Bottom 136.386 No Beam - 44.475 9.034
550
10000 x 350 x
Top 136.386 No Beam - 44.475 6.136
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 5.409
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 513 of 523

Check For Stability Index


Along D
       Q = 0.023
0.023< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.024
0.024< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = 76.85 kNm
M2 = -138.22 kNm
34 - 12 x (M1/M2) = 40.67
20.44 < 40.67, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = -142.28 kNm
M2 = 153.95 kNm
34 - 12 x (M1/M2) = 45.09
20.44 < 45.09, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -138.22 - -138.22
Major Axis Mux (bottom) 76.85 - 76.85
Minor Axis Muy (top) -142.28 - -142.28
Minor Axis Muy (bottom) 153.95 - 153.95

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 514 of 523

Pu = 970.49 kN
Mux = -138.22 kNm
Muy = -142.28 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16
Load Angle = Tan-1(Muy/Mux)
= 45.83 deg
MRes = 198.36 kNm
MCap = 264.28 kNm
Capacity Ratio = MRes/ MCap
= 0.751 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 367.55 kN
Muy = 137.42 kNm
Vuy = 84.8579 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 66.2 kNm
Vcy Permissible = 171.06 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 442.84 kN
Mux = 109.47 kNm
Vux = -68.4909 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 23.67 kNm
Vcx Permissible = 171.14 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 515 of 523

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C34
Level : 5.3m To 8.8m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 265
Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5 (LOAD 4: LL) +1.25
Load Combination =
(LOAD 2: EZ)
Critical Location = Bottom Joint
Put = 621.69 kN
Muxt = -112.22 kNm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 516 of 523

Muyt = -148.58 kNm


Vuxt = -81.54 kN
Vuyt = 72.93 kN
Pub = 650.98 kN
Muxb = 142.95 kNm
Muyb = 136.73 kNm
Vuxb = -81.54 kN
Vuyb = 72.93 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
10000 x 350 x
Bottom 136.386 No Beam - 44.475 6.136
550
10000 x 350 x
Top 136.386 No Beam - 44.475 6.136
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 3.674
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.017
0.017< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 517 of 523

       Q = 0.018
0.018< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm
Kluy /r = 20.44
M1 = -112.22 kNm
M2 = 142.95 kNm
34 - 12 x (M1/M2) = 43.42
20.44 < 43.42, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 136.73 kNm
M2 = -148.58 kNm
34 - 12 x (M1/M2) = 45.04
20.44 < 45.04, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -112.22 - -112.22
Major Axis Mux (bottom) 142.95 - 142.95
Minor Axis Muy (top) -148.58 - -148.58
Minor Axis Muy (bottom) 136.73 - 136.73

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 650.98 kN
Mux = 142.95 kNm
Muy = 136.73 kNm

Moment Capacity Check


Pt Calculated = 1.15
Reinforcement Provided = 4-#20 + 8-#16

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 518 of 523

Load Angle = Tan-1(Muy/Mux)


= 43.72 deg
MRes = 197.81 kNm
MCap = 269.35 kNm
Capacity Ratio = MRes/ MCap
= 0.734 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 23
[19] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 244.84 kN
Muy = 91.5 kNm
Vuy = 63.1863 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 44.06 kNm
Vcy Permissible = 171.78 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 24
[20] : 0.68 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 2: EZ)
Nu = 286.64 kN
Mux = 93.77 kNm
Vux = -59.221 kN
λ = 1
φ = 0.65
deff = 450 mm
ρw = 0.006
mm = 38.24 kNm
Vcx Permissible = 171.2 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 5 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 519 of 523

Criterion for spacing of normal


links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C34
Level : 8.8m To 12.3m
Design Code = ACI 318M - 2011
Grade Of Concrete = C21 N/sqmm
Grade Of Steel = Fy420 N/sqmm
Consider Ductile = No
Column B = 500 mm
Column D = 500 mm
Clear Cover = 40 mm
Clear Floor Height @ lux = 2950 mm
Clear Floor Height @ luy = 2950 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 388
Critical Analysis Load Combination : 14
Load Combination = [10] : 1.2 (LOAD 3: DL) +1.6 (LOAD 4: LL)
Critical Location = Top Joint
Put = 373.22 kN
Muxt = -437.24 kNm
Muyt = -150.67 kNm
Vuxt = -74.61 kN
Vuyt = 196.38 kN
Pub = 397.97 kN
Muxb = 249.89 kNm
Muyb = 110.38 kNm
Vuxb = -74.61 kN
Vuyb = 196.38 kN

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 520 of 523

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
10000 x 350 x
Bottom 136.386 No Beam - 44.475 6.136
550
10000 x 350 x
Top 136.386 No Beam - 44.475 3.068
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness Beta
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Width x
Depth) Depth)
N-M mm mm N-M N-M
6000 x 350 x
Bottom 136.386 No Beam - 74.125 3.674
550
6000 x 350 x
Top 136.386 No Beam - 74.125 1.837
550
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
       Q = 0.008
0.008< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
       Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 144.34 mm

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 521 of 523

Kluy /r = 20.44
M1 = 249.89 kNm
M2 = -437.24 kNm
34 - 12 x (M1/M2) = 40.86
20.44 < 40.86, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 144.34 mm
Klux /r = 20.44
M1 = 110.38 kNm
M2 = -150.67 kNm
34 - 12 x (M1/M2) = 42.79
20.44 < 42.79, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -437.24 - -437.24
Major Axis Mux (bottom) 249.89 - 249.89
Minor Axis Muy (top) -150.67 - -150.67
Minor Axis Muy (bottom) 110.38 - 110.38

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 373.22 kN
Mux = -437.24 kNm
Muy = -150.67 kNm

Moment Capacity Check


Pt Calculated = 2.86
Reinforcement Provided = 4-#32 + 8-#25
Load Angle = Tan-1(Muy/Mux)
= 19.01 deg
MRes = 462.47 kNm
MCap = 476.21 kNm
Capacity Ratio = MRes/ MCap
= 0.971 < 1

Design Of Shear

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 522 of 523

Design for shear along D


Critical Analysis Load Combination : 19
[15] : 1.42 (LOAD 3: DL) +1.25
Critical Load Combination = kN
(LOAD 1: EX)
Nu = 229.46 kN
Muy = 133.69 kNm
Vuy = 114.2142 kN
λ = 1
φ = 0.65
deff = 444 mm
ρw = 0.014
mm = 89.06 kNm
Vcy Permissible = 183.23 kN
Vuy < Vcy Permissible
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 16
[12] : 1.42 (LOAD 3: DL) +0.5
Critical Load Combination = kN
(LOAD 4: LL) +1.25 (LOAD 2: EZ)
Nu = 308.85 kN
Mux = 109.13 kNm
Vux = -77.1649 kN
λ = 1
φ = 0.65
deff = 444 mm
ρw = 0.014
mm = 49.06 kNm
Vcx Permissible = 179.7 kN
Vux < Vcx Permissible
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 8 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 400 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020
Column Design: Design Calculations Page 523 of 523

Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

file:///C:/Users/USER/AppData/Local/Temp/tmp491C.tmp 25/06/2020

You might also like