Rangoli Block E Typ.

Floor DEFLECTION CHECK


PANEL DETAILS REINFMNT. SPACING REQUIRED DEFLECTION CHECK AS PER IS-456

panel panel condition Lx Ly w D DIA AREA Sx+


Sy+ Sx- Sy-
mkd. (as per table 26, Annex D : IS 456) M M T/M 2
mm Ly/Lx mm mm2 mm c/c mm c/c mm c/c mm c/c STATUS

S1 4 TWO ADJ EDGE DISCONT. 3.48 4.08 1.0000 115 1.172 8 50.3 250 250 200 250 SAFE
S2 2 ONE SHORT EDGE DISCONT. 3.17 3.78 1.0000 110 1.193 8 50.3 250 250 250 250 SAFE
S3 2 ONE SHORT EDGE DISCONT. 1.98 3.18 1.0000 110 1.604 8 50.3 250 250 250 250 SAFE
S4 9 ALL EDGE DISCONT. 0.565 3.78 2.0000 110 6.681 8 50.3 250 250 NMNL NMNL SAFE
S5 7 ONE LONG EDGE CONT. 1.72 2.33 2.0000 110 1.356 8 50.3 250 250 250 NMNL SAFE
S6 5 TWO SHORT EDGE DISCONT. 2.82 3.43 1.0000 110 1.216 8 50.3 250 250 250 NMNL SAFE
S7 3 ONE LONG EDGE DISCONT. 1.26 3.47 1.0000 110 2.754 8 50.3 250 250 250 250 SAFE
S8 7 ONE LONG EDGE CONT. 1.53 3.56 1.0000 110 2.334 8 50.3 250 250 250 NMNL SAFE
S9 7 ONE LONG EDGE CONT. 1.51 3.43 1.0000 110 2.279 8 50.3 250 250 250 NMNL SAFE
S10 #N/A 1.0000 110 #DIV/0! 8 50.3 250 #N/A NMNL #N/A #N/A
S11 5 TWO SHORT EDGE DISCONT. 1.41 2.08 1.0000 110 1.475 8 50.3 250 250 250 NMNL SAFE
S12 7 ONE LONG EDGE CONT. 1.72 2.72 2.0000 110 1.586 8 50.3 250 250 250 NMNL SAFE

concrete 20
reinforcement 415
clear cover 20
minm. %age 0.12