1 2 3 4 1 2 3 4 1 2 3 4

12000 12000 12000


9050 2950 9050 2950 9050 2950

4350 4700 4350 4700 4350 4700

2200 6450 5150

P2 2600 1650 4300

600
C P2
REF
01

RANGE
P2 C C
WM 03 02 P2 TO CATV PB
2175

05

2800
ACU P1
08

4000
4750

4750

4750

4750
P1 P1 P2
06 P1 P2 07 06
1425

ACU ROOFING
WP

1600
TEL
TO TEL PB

12000
WP

B B B 1300

2350
WP

ACU P2 TO CATV PB
3550

3550

3550
2250

04 OPEN BELOW 3850


WP
P1
TEL 09

A TO TEL PB
A A
TEL PB
CATV PB
TEL SERVICE
ENTRANCE 1
kWHR
CATV SERVICE
ENTRANCE
METER
5650 900 1050 4200

GROUND FLOOR ELECTRICAL LAYOUT SECOND FLOOR ELECTRICAL LAYOUT ROOF DECK ELECTRICAL LAYOUT
1 (POWER & AUXILIARY SYSTEM) 2 (POWER & AUXILIARY SYSTEM) 3 (POWER & AUXILIARY SYSTEM)
SCALE 1: 100 METERS SCALE 1: 100 METERS SCALE 1: 100 METERS
E3 E3 E3

SERVICE ENTRANCE
230 V, 1-PHASE
SERVICE DROP
POWER SUPPLY 230 V 2-40.0 mm 2 THHN IN
32 mm Ø RSC PIPE,
ONE GANG 2-WIRE, 60 HERTZ 1-14 mm THHN
TELEPHONE MODULAR JACK
GRD. WIRE
CATV OUTLET TEL kW-HR CONCRETE
1 - 32Ø PVC 2 - 1"Ø PVC ( EMPTY ) METER PEDESTAL
( EMPTY ) W/ PULL WIRE
1 - CAT3/2PRS UTP CABLE
IN 20Ø PVC
1 - RG 6/U COAXIAL SINGLE PHASE
CABLE IN 20Ø PVC
SECOND FLOOR LINE SECOND FLOOR LINE 100 A
PB
12 X 12 X 4 0.41 X 0.41 X 0.15
PULLBOX CABINET

ONE GANG
TELEPHONE MODULAR JACK

CATV OUTLET TEL

1 - CAT3/2PRS UTP CABLE 2 2


IN 20Ø PVC
2-40mm , 1-14mm THHN Cu WIRE
1 - RG 6/U COAXIAL IN 32mm Ø RSC CONDUIT
CABLE IN 20Ø PVC
GROUND FLOOR LINE GROUND FLOOR LINE GROUND FLOOR LINE

UNDERGROUND SERVICE ENTRANCE

4
CATV RISER DIAGRAM 5
TELEPHONE RISER DIAGRAM 6
SERVICE ENTRANCE
N T S N T S N T S
E3 E3 E3

SHEET CONTENTS INPUT DR. CANARES REVISIONS SHEET NO OF SHTS.


ELLAZAR BUILDERS "DRAWINGS, AS INSTRUMENTS OF SERVICE ARE
ELECTRICAL ENGINEER
PROJECT PROPOSED 2-STOREY HOUSE WITH ROOFDECK DATE 08/14/2020
THE PROPERTY OF THE ARCHITECT, AND AS SUCH GRD FLR POWER & AUXILIARY SYSTEM
ARCHITECTS ENGINEERS CONTRACTORS MUST NOT BE REPRODUCED OR COPIED IN PART OR 2ND FLR POWER & AUXILIARY SYSTEM
OWNER RAYMOND NEPOMUCENO / JANNE CLARRISE CHICO REVISED
GENERAL BUILDING - GENERAL ENGINEERING
IN WHOLE WITHOUT PERMISSIONS. ALL DRAWINGS
ARE TO BE RETURNED WHEN NO LONGER IN USE."
RD POWER & AUXILIARY SYSTEM
CATV RISER DIAGRAM DATE E3 3
ELLAZAR Unit 204, 2nd floor C. Ramirez Bldg., #314 N.S. Amoranto Sr. Avenue,
BUILDERS Cor. Mayon Street, Sta. Mesa Heights, Quezon City, Philippines
ART. 04 SEC. 33 OF THE REPUBLIC ACT 9266 PRC NO.: TIN :
LOCATION B38 L62 CARMEL RIDGE RESIDENTIAL ESTATE TELEPHONE RISER DIAGRAM CHECKED

ellazar.builders@gmail.com / (02) 215-9400 / +63 917 5528835 PTR : WALING-WALING ST. BRGY. TULO CALAMBA CITY LAGUNASERVICE ENTRANCE DETAILS DATE
Proposed Two Storey house
FILENAME : with Roofdeck.dwg