PCVMT1522A

Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
S SERIES

For residential and commercial use

HEAD OFFICE :

SERVICE AND SPARE PARTS, Telp.: 021-736 92899 • Training Center, Telp. : 021-295 61950 • Bekasi, Telp.: 021-2945 0585,
Tangerang, Telp.: 021-5314 1195 • Bandung, Telp.: 022-5225 150 • Semarang, Telp.: 024-841 2695 • Yogyakarta, Telp.: 0274-551 321
Surabaya, Telp.: 031-503 1138 • Denpasar, Telp.: 0361-900 5514 • Makassar, Telp.: 0411-446 263 • Palembang, Telp.: 0711-319 776

Cooling Only 50 Hz
Specifications, designs and other content appearing in this brochure are current as of May 2015 but subject to change withoutotice.
n

c All rights reserved


Y.K.
Engineered for Flexibility S SERIES
First launched in Japan in 1982, the Daikin VRV system has been VRV indoor units combine with
residential indoor units, all in one system.
embraced by world markets for over 30 years. Now, Daikin proudly
introduces the new VRV IV S series-the ideal air conditioning system
for homes, shops and offices. BP unit

Max.
14 indoor
units Residential indoor units VRV indoor units

* VRV is a trademark of Daikin Industries, Ltd.

Contents OFFICES
Main Features P03
Indoor Unit Lineup P09
Specifications P34
Option List P47
Control Systems P53
Air Treatment Equipment Lineup P63

SHOPS

01
HOMES 02
Main Features

Compact & lightweight design Enhanced lineup


The new design has been optimised for the VRV IV S series, with the height of 4 HP to 5 HP models reduced to only To suit a variety of room sizes, VRV IV S series expands our range to include 8 HP and 9 HP.
990 mm. This design gives the building a sleek look externally and provides the occupants with a clear, unobstructed
view of the scenery. The VRV IV S series is now slim and compact, with outdoor units that require minimal installation
space. S SERIES

VRV S S SERIES Mo/C*


4, 5 HP 4 HP
4, 5 HP VRV
4 HP
S (11.2 kW) S SERIES (11.2 kW)
Mo/C* Mo/C*

Height Height 26%


1,345 1,345 mm 990 mm Decrease
mm 990
mm
Product Product
Weight Weight 43%
Decrease
320 125 kg 71 kg 4 HP 5 HP 6 HP 8 HP 9 HP
320 mm
mm *Mo/C represents Model Change

Lineup 5 models
8 HP
S SERIES 8 HP
( 22.4 k W) S SERIES ( 22.4 k W)
Model Name RXMQ4AVE RXMQ5AVE RXMQ6AVE RXMQ8AY1 RXMQ9AY1
8 HP 8 HP Power Supply 1-phase, 220- 230 V /220 V , 50/60 Hz 3-phase, 380 – 415 V , 50 Hz
Height Height 14% 4 HP 5 HP 6 HP 8 HP 9 HP
1,657 mm 1,430 mm Decrease Capacity Range
(11.2 kW) (14.0 kW) (16.0 kW) (22.4 kW) (24.0 kW)

Product Weight Product Weight Capacity Index 100 125 150 200 215
1,657
mm
1,430 29%
mm 185 kg 131 kg Decrease

Footprint Footprint 58%


0.71 m 2 0.30 m 2 Decrease
765
mm
930 940 320
mm
Wide variety of indoor units
mm mm

Indoor units can be selected from 2 lineups, bothVRV and residential


indoor units, to match rooms and preferences. A mixed combination of
VRV indoor units and residential indoor units can be included into one
system, opening the door to stylish and quiet indoor units.

Elegant appearance with


External view of European style
a condominium

Internal view of a
condominium unit
FTKJ-N series indoor unit

03 04
Main Features

Energy saving
Higher Coefficient of Performance (COP) Collection of cutting-edge technologies realises efficient and quiet operation
VRV IV S series provides greater energy saving as compared to VRV III S series, especially for 6 HP. The high efficiency compressor to achieve a higher COP

12% 1 Compressor equipped with Reluctance DC motor


Increase
Daikin DC inverter models are equipped with the Reluctance DC motor for
Cooling
Operation
4 3.80
3.89 3.86 compressor. The Reluctance DC motor uses 2 different types of torque, neodymium
COP 3.8 3.77 magnet*1 and reluctance torque*2. This motor can save energy because it generates
3

3.6 3.56 3.49 more power with a smaller electric power than an AC or conventional DC motor.
3.4 2
Reluctance DC motor
3.2 90

Motor efficiency (%)


0
4 HP 5 HP 6 HP 8 HP 9 HP 80 Reluctance
(11.2 kW) (14.0 kW) (16.0 kW) (22.4 kW) (24.0 kW)
Conventional DC motor DC motor
*Cooling operation conditions: Indoor temp. of 27ºCDB,19ºCWB, and outdoor temp. of 35ºCDB. 70 More than 20% 1
VRV S
S SERIES 60 AC motor

50
0 30 60 90 120
Rotational speed (rps)

Small load Large load


Low capacity High capacity

Quiet operation Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products.
*1 A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.
*2 The torque created by the change in power between the iron and magnet parts. Sine wave DC inverter

Nighttime quiet operation function


>> Smooth sine wave DC inverter
Operation sound level selectable from 3 steps for the night mode Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency.

Mode 1. Automatic mode Mode 1. Automatic mode RXMQ 4, 5, 6AVE RXMQ8, 9AY1

Set on the outdoor PCB. Time of maximum >> Swing compressor >> The structural scroll Suction
temperature is memorised. The low operating mode
Load % Capacity %

Daikin swing compressor has integrated the Sucked gas is


will initiate 8 hours*1 after the peak temperature in Peak in outdoor temperature rotor with the blade, completely solving the compressed in the Scroll section
the daytime, and normal operation will resume 10 100
refrigerant leakage and the wear problem scrolling part before the
hours*2 after that. The operation sound level for the caused by the mechanical friction between the heated motor, so that Discharge Motor section
night mode can be selected from 49 dB(A) (Step 1), 8 hrs 10 hrs rotor and the blade, which enhances the the machine compress
46 dB(A) (Step 2) and 43 dB(A) (Step 3).* 3 50
(Initial setting) (Initial setting)
compressor efficiency and makes the the non-expanded gas,
compressor more quiet and durable. resulting in high efficiency compression.
Mode 2. Manual mode
0
Operation sound dB(A)

Starting time and ending time can be input. (An Night Mode
52 2 Smooth Air Inlet Bell Mouth and Aero Spiral Fan 3 DC fan motor
external control adaptor for outdoor unit,
Step 1 max. - 3 dB(A) Step 1: 49 dB(A)
DTA104A53/61/62, and a locally obtained timer are These two features work to reduce sound. Guides are added to Efficiency improved in all areas
49
necessary.) the bell mouth intake to reduce turbulence in the airflow generated compared to conventional AC
Step 2 max. - 6 dB(A) Step 2: 46 dB(A)
by fan suction. The Aero Spiral Fan features fan blades with the motors, especially at low speeds.
46
bent blade edges, further reducing turbulence. DC fan motor structure
Mode 3. Combined mode Step 3 max. - 9 dB(A) Step 3: 43 dB(A)
43 With the bent Without the bent
Combinations of modes 1 and 2 can be used Night mode starts Night mode ends blade edge blade edge
depending on your needs.
8:00 12:00 16:00 20:00 0:00 4:00 8:00

*1. Initial setting. Can be selected from 6, 8 and 10 hours. Note: • This function is available in setting at site.
*2. Initial setting. Can be selected from 8, 9 and 10 hours. • The relationship of outdoor temperature (load) and time shown in the
*3. In case of 4 HP outdoor unit during cooling operation graph is just an example.
The capacity reduction rate differs depending on the operation sound level step selected.
Escaping eddies are sucked in by
the bent blade edges, reducing
overall turbulence.

05 06
Main Features

Design flexibility and simplified installation Long piping design possible


Connectable up to 14 indoor units Long piping length offers flexibility in the choice of installation positions, and simplifies system planning.

As many as 14 indoor units can be connected to a single outdoor unit, making theVRV IV S series a remarkably When only VRV indoor units are connected
versatile system.

Note: Total capacity index of connectable indoor units must be 50-130% of the capacity index of the outdoor unit.
Refer to page 46 for the maximum number of connectable indoor unit.
a
Actual piping length b c d

Max. Max. 120 m First indoor branch


e f g h i
14 indoor
units Total piping length Max.

BP u n i t BP u n i t
Max. 300 m 50 m k
Max.
j 15 m
Residential indoor units
4 HP 5 HP 6 HP 8,9 HP
Refrigerant piping length a+b+c+d+i 50 m 70 m 120 m 100 m
Max. allowable piping
Total piping length a+b+c+d+e+f+g+h+i 250 m 300 m 300 m 300 m
length
Between the first indoor branch and the farthest indoor unit b+c+d+i 40 m 40 m 40 m 40 m

Between the indoor units j 10 m 15 m 15 m 15 m


VRV indoor units Max. allowable level
difference Between the outdoor unit If the outdoor unit is above k 30 m 30 m 50 m 50 m
and the indoor unit If the outdoor unit is below k 30 m 30 m 40 m 40 m

Automatic test operation


When a mixed combination of VRV and residential indoor units is connected or
Simply press the test operation button and the unit performs an automatic system check, including wiring, stop valves,
piping, and refrigerant charging amount. The results are returned automatically after the check finishes.
when only residential indoor units are connected

Simple wiring and piping connection b c


Actual piping length a d
Unique piping and wiring systems make it possible to install aVRV IV S series quickly and easily. Max. 100 m First indoor branch
e f g Max.
o
Total piping length
BP 40 m
>> Super wiring system Max. Max.
m
A super wiring system is used to enable Max. 250 m 50 m n h i
j
BP 15 m
shared use of the wiring between indoor
and outdoor units and the central control RA RA VRV
Outdoor unit k
wiring, with a relatively simple wiring Max. RA VRV
operation. l 15 m
The DIII-NET communication system is
RA
employed to enable the use of advanced
control systems. 4 HP 5 HP 6-9 HP
Indoor unit Refrigerant piping length a+b+c+g+k, a+b+c+d 50 m 70 m 100 m
Max. allowable piping Total piping length a+b+c+d+e+f+g+h+i+j+k 250 m 250 m 250 m
length
>> REFNET piping system The first indoor branch - the farthest BP orVRV indoor unit b+c+g, b+c+d 40 m 40 m 40 m
If indoor unit capacity index < 60 2 m–15 m 2 m–15 m 2 m–15 m
Daikin’s advanced REFNET piping system Max. & min.
allowable piping BP unit - indoor unit If indoor unit capacity index is 60 h, i, j, k 2 m–12 m 2 m–12 m 2 m–12 m
makes installation easy. Only two main length
If indoor unit capacity index is 71 2 m–8 m 2 m–8 m 2 m–8 m
refrigerant lines are required in any one
system. REFNET greatly reduces the Min. allowable piping length Outdoor unit - the first indoor branch a 5m 5m 5m
imbalances in refrigerant flow between Between the indoor units l 10 m 15 m 15 m
units, while using small-diameter piping. Between BP units m 10 m 15 m 15 m
Max. allowable level
Outdoor unit - the indoor If the outdoor unit is above n 30 m 30 m 50 m
difference
unit If the outdoor unit is below n 30 m 30 m 40 m
Outdoor unit - the BP unit o 30 m 30 m 40 m

07 08
Indoor Unit Lineup

Enhanced range of choices


A mixed combination of VRV indoor units and residential indoor units can be included into
one system, opening the door to stylish and quiet indoor units.

VRV indoor units 19 types 99 models Residential indoor units with connection to BP units 6 types 18 models
20 25 32 40 50 63 71 80 100 125 140 200 250 25 35 50 60 71
Type Model Name Capacity Range 0.8HP 1HP 1.25HP 1.6HP 2HP 2.5HP 3HP 3.2HP 4HP 5HP 6HP 8HP 10HP Type Model Name Rated Capacity (kW) 2.5 3.5 5.0 6.0 7.1
Capacity Index 20 25 31.25 40 50 62.5 71 80 100 125 140 200 250 Capacity Index 25 35 50 60 71
Ceiling Mounted
Cassette(Round FXFQ-SVM FDKS-EAVMB
Flow with Sensing) (700 mm width type)
Slim Ceiling
Mounted Duct
Ceiling Mounted
Cassette FXFQ-LUV1 FDKS-C(A)VMB
(Round Flow) (900/1,100 mm width type)

Ceiling Mounted
Cassette FXZQ-MVE FTKJ-NVMW
(Compact Multi Flow)

Ceiling Mounted FTKJ-NVMS


Cassette FXCQ-MVE
(Double Flow) Wall Mounted
FTKS-DVM
Ceiling Mounted
Cassette Corner
FXKQ-MAVE
FTKS-BVMA
FXDQ-PBVE
(with drain pump) FTKS-FVM

FXDQ-PBVET (700 mm width type)

Slim Ceiling (without drain pump)


Mounted Duct
(Standard Series)
FXDQ-NBVE VRV indoor units combine with indoor units, all in one system.
(with drain pump)

FXDQ-NBVET (900/1,100 mm width type)


(without drain pump)

Slim Ceiling
BP unit
Mounted Duct FXDQ-SPV1
(Compact Series)

Middle Static
Pressure Ceiling FXSQ-PVE Max.
Mounted Duct
14 indoor
units Residential indoor units VRV indoor units
FXMQ-PVE
Ceiling Mounted
Duct

FXMQ-MAVE

4-Way Flow
Ceiling Suspended FXUQ-AVEB

Ceiling Suspended FXHQ-MAVE

Max.
Wall Mounted FXAQ-PVE
14 indoor
units VRV indoor units only
Floor Standing FXLQ-MAVE *Refer to page 46 for the maximum number of connectable indoor units.

Concealed
Floor Standing FXNQ-MAVE

Floor Standing
Duct
FXVQ-NY1

09 10
Indoor Unit Lineup

Daikin offers a wide range of indoor units includes both VRV and residential models responding to variety of needs of
our customers that require air-conditioning solutions.
Ceiling Mounted Duct Type 4-Way Flow Ceiling
Suspended Type
FXMQ-PVE
FXUQ-AVEB
VRV indoor units
FXMQ-MAVE
This slim and stylish indoor unit
Ceiling Mounted Cassette Ceiling Mounted Cassette achieves optimum air distribution,
and can be installed without the
(Round Flow with Sensing) Type (Round Flow) Type High external static pressure
need for ceiling cavity
allows flexible installations
FXFQ-SVM FXFQ-LUV1

Ceiling Suspended Type Wall Mounted Type


FXHQ-MAVE FXAQ-PVE

Presence of people and floor 360 airflow improves temperature


temperature can be detected to distribution and offers a comfortable
provide comfort and energy savings living environment.

Stylish flat panel design


Slim body with quiet and wide airflow harmonised with your interior
décor
Ceiling Mounted Cassette Ceiling Mounted Cassette
(Compact Multi Flow) Type (Double Flow) Type
FXZQ-MVE FXCQ-MVE Floor Standing Type Floor Standing Duct Type
FXLQ-MAVE FXVQ-NY1

Concealed Floor Standing Type


FXNQ-MAVE
Quiet, compact, and designed for Thin, lightweight, and easy to install in
user comfort narrow ceiling spaces
Suitable for perimeter zone air Large airfiow type for large spaces.
conditioning Flexible interior design for each tenant.

Ceiling Mounted Cassette Slim Ceiling Mounted Duct Type


Corner Type (Standard Series)
Residential indoor units with connection to BP units
FXKQ-MAVE FXDQ-PBVE(T)
Slim Ceiling Mounted Wall Mounted Type
Duct Type
FTKJ-NVMW
FDKS-EAVMB
FXDQ-NBVE(T)

FTKJ-NVMS
FDKS-C(A)VMB
Slim design for flexible installation Slim design, quietness and
static pressure switching
Slim and smooth design suits Elegant appearance with
your shallow ceiling European style

Slim Ceiling Mounted Duct Type Middle Static Pressure Ceiling


(Compact Series) Mounted Duct Type Wall Mounted Type
FXDQ-SPV1 FXSQ-PVE FTKS-DVM

FTKS-BVMA

FTKS-FVM

Slim and compact design for easy and Middle external static pressure Stylish flat panel harmonises
flexible installation and slim design allow flexible installations with your interior décor

11 12
Indoor Unit Lineup
VRV Indoor Units

Ceiling Mounted Cassette (Round Flow with Sensing) Type Sensing function
Draft prevention function (default: OFF) *1. 2 Auto airflow direction mode

Cooling Dry

FXFQ25S / FXFQ32S / FXFQ40S


When human presence not detected. When human presence detected.
FXFQ50S / FXFQ63S / FXFQ80S
FXFQ100S / FXFQ125S

Presence of people and floor temperature can be


detected
tected to provide comfort
co and energy savings Swing Swing Blown horizontally

With the Auto airflow direction mode, flaps are When a person is detected, drafts are prevented by
controlled to deliver optimal air distribution for both cooling making the flap horizontal.
and heating operations when there are no people.

When a person is not detected for 5 minutes,


Detecting the
the unit automatically returns to controlling the
presence of flaps for an unoccupied room.
people in 4 areas
*1.Airflow direction shoud be set to Auto. *2.Draft prevention function is OFF in the initial setting. It can be set ON using the remote controller.

Auto airflow direction mode +


Comfort and Energy saving preventing over Cooling *1. 2 Auto airflow rate mode

Detecting the average


temperature of indoor floor Cooling
Floor temperature is detected and over cooling prevented.
Without sensing function With sensing function
Indoor unit offers 360° airflow discharges air in all
directions with more uniform temperature distribution.

Individual airflow direction control


30°C near ceiling
Thanks to the individual airflow direction control 30°C near ceiling
function, airflow direction can be individually adjusted Room
for each air discharge outlet to prevent uncomfortable temperature is Room temperature is
drafts and to deliver optimal air distribution. detected as calculated as 27°C in the area which
30°C. is in the vicinity of the person.
Dead spot of airflow
Infrared presence sensor 20°C near floor 24°C near floor
Improved energy efficiency thanks to a new heat
The sensor detects human presence and adjusts the exchanger with smaller tubes, DC fan motor, and DC drain
airflow direction automatically to prevent drafts. pump motor.
Ceiling height 2.7m 3.5m 4.0m Area around feet gets too cold because air conditioner The floor temperature, Automatic control using the
approx. approx. approx. continues until the temperature near the ceiling reaches the which is lower than near temperature near the person
Detection range (diameter)*1 8.5m 11.5m 13.5m Low operation sound level the ceiling, is detected. as the room temperature.
set temperature.
*1. The infrared presence sensor detects 80 cm above the floor. FXFQ-S 25/32 40 50 63 80 100 125
Sound level 30/28.5/27 31/29/27 36/32/28 38/33/28 38/35/31 44/38/32 45/40/35
(H/M/L)

Infrared floor sensor Energy The temperature near the person is automatically calculated by detecting the temperature of the floor. Energy is
savings saved, because the area around the feet does not get too cold.
Drain pump is equipped
The sensor detects the floor temperature and automatically as standard accessory
adjusts operation of the indoor unit to reduce the 850 mm To increase comfort, Auto airflow rate mode controls the airflow in accordance with
with 850 mm lift. the difference between floor and ceiling temperatures.
temperature difference between the ceiling and the floor.
Ceiling height 2.7m 3.5m 4.0m When there is a large difference between the ceiling and floor temperatures, the airflow rate is automatically increased.
approx. approx. approx. When the difference becomes small, the airflow rate is automatically reduced.
Detection range (diameter) *2 11m 14m 16m Selectable airflow rate: 3 steps and Auto. *1.Both airflow direction and airflow rate shoud be set to Auto. *2.Draft prevention function is set OFF in the initial setting.
*2. The infrared floor sensor detects at the floor surface. (Auto airflow rate is available when BRC1E62 is used.)

13 14
Indoor Unit Lineup
VRV Indoor Units

Ceiling Mounted Cassette (Round Flow with Sensing) Type Individual airflow direction control
Individual airflow setting

Sensing sensor low mode (default: OFF) Airflow direction of each of the four air outlets can be controlled individually.
(Positions 0 to 4, Swing, Blocked, and No individual setting are selectable. )
When there are no people in a room, Example
the set temperature is shifted automatically.
The system automatically saves energy by 1 Blocked No individual
2 setting
detecting whether or not the room is occupied. The blocked (Auto direction)
set temperature is shifted automatically if the room No ind. set
is unoccupied.

A
2
Operation is reduced in places
where there are no people.

1
4 Swing 3 Position 2
Swing Position 2
• Cooling setpoint: 26℃ • Shift temperature: 1.0℃
Example
• Shift time:30 min. • Limit cooling temperature:30℃
28 28℃
27 27℃ 4 Outlet mark
Setpoint (℃)

26 26℃ 26℃
Automatically If people do not return, the
Occupied reverts when
Unoccupied people return. air conditioner will raise the
temperature 1℃ every 30
Airflow block function*1
minutes and then operate
at 30℃. Total comfort by individual airflow direction control and “airflow block function”
Time
After 30 min After another 30 min The system automatically saves energy by detecting
whether or not the room is occupied. The set temperature
is shifted automatically if the room is unoccupied. Airflow block
Shift temperature and time can be selected from 0.5 to 4℃ in 0.5℃ increments and 15, 30, 45, 60, 90 or 120 minutes
respectively with remote controller. air velocity
approx. 0.3m/s*1
Airflow block function prevents uncomfortable drafts by
reducing air velocity.
It can be set using the BRC1E62 remote controller. There is no
Sensing sensor stop mode (default: OFF) need for sealing material of air discharge outlet (option).

When there are no people in a room, the system stops automatically.* 3 This function only works when all-round flow is used. It cannot
be used when sealing material is used in the air discharge
Airflow block function prevents uncomfortable drafts by reducing air velocity to
The system automatically saves energy by detecting whether or outlet (option). approx. 0.3m/s.*2
not the room is occupied.
Airflow block Also can support
Based on preset user conditions, the system automatically stops Easy setup with remote controller for cabinet side such case
operation if the room is unoccupied.
The airflow block function
Absent stop time can be selected from 1 to 24 hrs in 1 hr increments is useful when rearranging
with remote controller. the room layout.

500 mm
*3
Airflow
block

Horizontal
H i t l fl
flow Airflow
Ai fl block
bl k Wall

*1. Works in one direction only.


*1.These functions are not available when using the group control system. *2. In case of FXFQ63S type (Data is based on Daikin research.) When using FXFQ80S type or higher, if the airflow rate is set to High, airflow will be on the high side.
*2.User can set these functions with remote controller. Under actual conditions, however, the airflow value may differ depending on the effect of surrounding conditions and the way in which the temperature was adjusted.
*3.Please note that upon re-entering the room, air conditioner will not switch on automatically. *3. A gap of 1500 mm is required if the air block function is not used.

15 16
Indoor Unit Lineup
VRV Indoor Units

Ceiling Mounted Cassette (Round Flow) Type Ceiling Mounted Cassette (Compact Multi Flow) Type

FXFQ25LU / FXFQ32LU / FXFQ40LU


FXZQ20M / FXZQ25M / FXZQ32M
FXFQ50LU / FXFQ63LU / FXFQ80LU
FXZQ40M / FXZQ50M
FXFQ100LU / FXFQ125LU

360° airflow improves temperature distribution Quiet, compact, and designed for user comfort
and offers a comfortable living environment. Dimensions correspond with 600 mm X 600 mm
architectural module ceiling design specifications.
The industry’s first* Round Flow Ceiling Mounted
Cassette type offers 360° airflow with improved Low operation sound level
temperature distribution. (230 V)(dB(A))
4-way flow Round Flow FXZQ-M 20/25 32 40 50

Sound level
(H/L) 30/25
32/29 32/26
33/29 36/28
36/30 41/33
41/34

Comfortable airflow
There are areas of There are much fewer 1 Wide discharge angle: 0° to 60°
uneven temperature. areas of uneven temperature.
* As of April 2004, the release date for Japan. Auto swing

The light weight unit at 19.5 kg for FXFQ25-50LU


models makes installation easy.
Drain pump is equipped as a 0° 0°
850 mm
standard accessory with a 850 mm
lift. 60°
60°
A modern sophisticated decoration panel has been
Fixed angles: 5 levels
applied, with a panel surface that has been treated with
a dirt-repellant coating. An antibacterial treatment that uses silver ions has
Treated surface Untreated surface
been applied to the drain pan, preventing the growth
of slime, mould and bacteria that cause blockages
Dirt and 0° 0°
Resists grime • Condition after and odours. Drain pump is equipped as standard accessory with
soiling exposure to the
smoke of 600 750 mm lift.
cigarettes in 1 m
3 The horizontal louvres prevent dew condensation. 60° 60°
enclosed space.
Their non-flocking surfaces, which repel dirt, are *Angles can be also set on site to prevent drafts (0°-35°)
Control of the airflow rate can be selected from 3-step easy to clean. or soiling of the ceiling (25°-60°), other than standard setting (0°-60°).
control. 750 mm
The air filter has an anti-mould and antibacterial 2 2-, 3-, and 4-way airflow patterns are available,
Low operation sound level (dB(A))
treatment that prevents the growth of mould enabling installation in the corner of a room.
FXFQ-LU 25/32 40 50 63 80 100 125
generated from dust or moisture that may adhere to
Sound
level 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 the filter.
(HH/H/L)

Example of airflow patterns: All-round flow 4-way flow 3-way flow L-shaped 2-way flow
All-round flow is available, as well as 2-way to
4-way flows, so you can choose the most
suitable airflow pattern depending on location or L-shaped
room layout. 4-way flow 3-way flow 2-way flow

*For 3-way or 2-way flow installation, the sealing material for air discharge outlet
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet. (option) must be used to close each unused outlet.

17 18
Indoor Unit Lineup
VRV Indoor Units

Ceiling Mounted Cassette (Double Flow) Type Ceiling Mounted Cassette Corner Type

FXCQ20M / FXCQ25M / FXCQ32M


FXKQ25MA / FXKQ32MA
FXCQ40M / FXCQ50M / FXCQ63M
FXKQ40MA / FXKQ63MA
FXCQ80M / FXCQ125M

Thin, lightweight, and easy to install in Slim design for flexible installation
narrow ceiling spaces
Slim body needs only 220 mm space above the Providing 3 different settings of standard, draft
ceiling. If you use a panel spacer (option), the prevention and ceiling soiling prevention, the
The thin unit (only 305 mm high) can be installed in a unit can be installed in the minimum space of auto swing mechanism realises even distribution
ceiling space as narrow as 350 mm. All models feature a
195 mm. of airflow and room temperature.
compact design with a depth of only 600 mm.
(m)
Min.195 mm 3
28˚C 26˚C
24˚C
Panel spacer
305 mm 2 32˚C 30˚C
20 mm 22˚C
1 20˚C

(When a high-efficiency filter is attached, the unit's height is Single-flow type allows effective air discharge
0 1 2 3 4 5 6 (m)
400 mm.) from corner or from drop-ceiling.
Front discharge is possible with an air discharge
Low operation sound level (220 V)(dB(A))
Drain pump is equipped as standard unit (option), which allows the installation in the
FXCQ-M 20 25/32 40/50 63 80 125
accessory with 500 mm lift. drop-ceiling or sagging wall.
Sound level
32/27 34/28 34/29 37/32 39/34 44/38
(H/L) Main body

500 mm
Downward discharge
Designed with higher airflow suitable for high ceiling
application up to 3 metres.
Air discharge grille (Option)

Providing 2 different settings of standard and ceiling soiling Two types of optional high-efficiency filter are available
prevention, the auto swing mechanism realises even (65% and 95%, colourimetric method).
Set for front discharge using a suspended ceiling.
distribution of airflow and room temperature.
Main body
A long-life filter (maintenance free up to one year*) is
Drain pump is equipped as standard accessory with equipped as standard accessory.
600 mm lift. * 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

Air discharge grille


(Option)
Major maintenance work can be performed by removing
600 mm the panel. A flat-type suction grille and a detachable
blade make cleaning easy.
Downward discharge is shut off and air is blown straight out
(front discharge).

A long-life filter (maintenance free up to one


year*) is equipped as standard accessory.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

19 20
Indoor Unit Lineup
VRV Indoor Units

Ceiling Mounted Cassette (Double Flow) Type Ceiling Mounted Cassette Corner Type

FXCQ20M / FXCQ25M / FXCQ32M


FXKQ25MA / FXKQ32MA
FXCQ40M / FXCQ50M / FXCQ63M
FXKQ40MA / FXKQ63MA
FXCQ80M / FXCQ125M

Thin, lightweight, and easy to install in Slim design for flexible installation
narrow ceiling spaces
Slim body needs only 220 mm space above the Providing 3 different settings of standard, draft
ceiling. If you use a panel spacer (option), the prevention and ceiling soiling prevention, the
The thin unit (only 305 mm high) can be installed in a unit can be installed in the minimum space of auto swing mechanism realises even distribution
ceiling space as narrow as 350 mm. All models feature a
195 mm. of airflow and room temperature.
compact design with a depth of only 600 mm.
(m)
Min.195 mm 3
28˚C 26˚C
24˚C
Panel spacer
305 mm 2 32˚C 30˚C
20 mm 22˚C
1 20˚C

(When a high-efficiency filter is attached, the unit's height is Single-flow type allows effective air discharge
0 1 2 3 4 5 6 (m)
400 mm.) from corner or from drop-ceiling.
Front discharge is possible with an air discharge
Low operation sound level (220 V)(dB(A))
Drain pump is equipped as standard unit (option), which allows the installation in the
FXCQ-M 20 25/32 40/50 63 80 125
accessory with 500 mm lift. drop-ceiling or sagging wall.
Sound level
32/27 34/28 34/29 37/32 39/34 44/38
(H/L) Main body

500 mm
Downward discharge
Designed with higher airflow suitable for high ceiling
application up to 3 metres.
Air discharge grille (Option)

Providing 2 different settings of standard and ceiling soiling Two types of optional high-efficiency filter are available
prevention, the auto swing mechanism realises even (65% and 95%, colourimetric method).
Set for front discharge using a suspended ceiling.
distribution of airflow and room temperature.
Main body
A long-life filter (maintenance free up to one year*) is
Drain pump is equipped as standard accessory with equipped as standard accessory.
600 mm lift. * 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

Air discharge grille


(Option)
Major maintenance work can be performed by removing
600 mm the panel. A flat-type suction grille and a detachable
blade make cleaning easy.
Downward discharge is shut off and air is blown straight out
(front discharge).

A long-life filter (maintenance free up to one


year*) is equipped as standard accessory.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

19 20
Indoor Unit Lineup
VRV Indoor Units

Middle Static Pressure Ceiling Mounted Duct Type Indoor Unit Design flexibility
Adjustable external static pressure
Using a DC fan motor, the external static pressure can
be controlled within a range of 30 Pa* to 150 Pa.
FXSQ20P / FXSQ25P / FXSQ32P
FXSQ40P / FXSQ50P / FXSQ63P
FXSQ80P / FXSQ100P Adjustable external static pressure
FXSQ125P / FXSQ140P
30 Pa* 150 Pa
Middle external static pressure
and slim design allow flexible installations Set to low static
pressure when ducts
Set to high static pressure for
advanced needs such as when
are short. using dampers and long ducts.

Installation flexibility
Comfortable airflow is achieved in accordance with
Slim design Bottom suction possible
conditions such as duct length.
With a height of only 245 mm, installation is possible Bottom suction is possible which facilitates installation
even in buildings with narrow ceiling spaces. and maintenance. Wiring connections and
maintenance of control box can be done from under *30 Pa–150 Pa for FXSQ20-40PVE
the unit with an optional shield plate for side plate*, 50 Pa–150 Pa for FXSQ50-125PVE
extending the degree of freedom for installation in the 50 Pa–140 Pa for FXSQ140PVE
245 mm ceiling.

Comfort Easy installation


Air conditioner Joist
Switchable airflow rate Airflow rate auto adjustment function
Control of the airflow rate can be selected from 3-step During installation, even if the external static pressure
245 mm

Air suction
control. changes due to a change in the duct route, the airflow
ceiling
can be automatically adjusted to within the unit’s
Ceiling external static pressure range.
Auto airflow rate
5-step airflow rate is automatically controlled in Airflow rate can be controlled using a remote
Air suction direction can be altered from rear to
accordance with the difference between room controller during test operation. It is automatically
Standard DC drain pump bottom suction.
temperature and set temperature. adjusted to the range between approximately ±10% of
DC drain pump is Auto airflow rate control can be selected with wired the rated H tap airflow.
Rear suction
equipped as standard remote controller BRC1E62.
accessory with 850 mm
850 mm lift.

Ceiling
Easy maintenance

Inspection and cleaning is facilitated by separating the


Switch bottom plate
drain pipe and inspection opening and by the
with air suction flange. drain pan maintenance check hole.
Bottom suction
Low operation sound level (dB(A)) Separate drain pipe
Shield plate for side plate* (Option) and inspection opening

FXSQ-PVE 20/25 32 40 50 63

Sound level Drain pan maintenance check hole


(H/M/L) 33/30/28 34/32/30 36/33/30 34/32/29 36/32/29

FXSQ-PVE 80 100 125 140 The drain pan can be detached for easy cleaning.
An antibacterial treatment that uses silver ions has been
*An optional shield plate for side plate is required if wiring connections and Sound level
maintenance of control box are needed from under the unit. This option is only (H/M/L) 37.5/34/30 39/35/32 42/38.5/35 43/40/36 applied to the drain pan, preventing the growth of slime,
available for FXSQ20-125P models. mould and bacteria that cause blockages and odours.

23 24
Indoor Unit Lineup
VRV Indoor Units

Ceiling Mounted Duct Type 4-Way Flow Ceiling Suspended Type

FXMQ20P / FXMQ25P / FXMQ32P


FXMQ40P / FXMQ50P / FXMQ63P FXUQ71A / FXUQ100A
FXMQ80P / FXMQ100P / FXMQ125P
FXMQ140P

This slim and stylish indoor unit achieves


Middle and high static pressure optimum air distribution, and can be installed
allows for flexible duct design without the need for ceiling cavity.
A DC fan motor increases the external static pressure
capacity range to include middle to high static Unit body and suction panel
pressures, increasing design flexibility. adopted round shapes and
realised a slim appearance
30 Pa–100 Pa for FXMQ20P-32P
30 Pa–160 Pa for FXMQ40P design. The unit can be used
50 Pa–200 Pa for FXMQ50P-125P for various locations such as
50 Pa–140 Pa for FXMQ140P the ceilings with no cavity and
bare ceilings.
All models are only 300 mm in height, an improvement
over the 390 mm height of conventional models. The Flaps close automatically when
weight of the FXMQ40P has been reduced from 44 kg the unit stops, which gives a
to 28 kg. simple appearance.
Drain pump is equipped as Unified slim height of 198 mm
standard accessory with 700 mm for all models that gives the
700 mm lift. unified impression even when 198 mm
Ceiling
models with different capacities
Control of the airflow rate has been improved from Improved ease of installation are installed in the same area.
2-step to 3-step control. Airflow rate can be controlled using a remote controller Built-in electronic expansion valve eliminates the need Control of the airflow rate has been improved from
during test operation. With the conventional model, the for a BEV unit, which improves flexibility of installation. 2-step to 3-step control. Auto airflow rate control can
Low operation sound level (dB (A)) be selected with wired remote controller BRC1E62.
airflow rate was controlled from the PC board. It is Current model New model
FXMQ-P 20/25 32 40 50 63 80/100 125 140
Sound automatically adjusted to the range between approximately Energy efficiency has been improved thanks to the
level
(HH/H/L)
33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 46/45/43 ±10% of the rated HH tap airflow for FXMQ20P–125P. adoption of a new heat exchanger with smaller
Improved ease of maintenance tubes, DC fan motor and DC drain pump motor.
Energy-efficient
The drain pan can be detached for easy cleaning. An BEV unit is Drain pump is equipped as a standard accessory, and the
The adopted DC fan motor is much more efficient than antibacterial treatment that uses silver ions has been needed
BEV unit is
not needed lift height has been improved from 500 mm to 600 mm.
the conventional AC motor, yielding an approximate applied to the drain pan, preventing the growth of slime,
20% decrease in energy consumption (FXMQ125P). mould and bacteria that cause blockages and odours. Depending on installation site requirements or room
With adoption of the individual flap control, airflow
conditions, 2-way, 3-way and 4-way discharge
direction adjustment can be individually set for each air
patterns are available.
outlet. 5 directions of airflow and auto-swing can be
FXMQ200MA/FXMQ250MA Built-in Drain Pump (Option) selected with wired remote controller BRC1E62, which 4-way flow 3-way flow
Housing the drain pump inside the unit reduces the realises the optimum air distribution.
space required for installation.
Individual airflow direction example case
Without drain pump With drain pump Position 0 Position 2

0–250
mm

470 mm 470 mm L-shaped 2-way flow


222 mm
Position 3 Swing
Simplified Static Pressure Control 25 mm

External static pressure can be easily adjusted using a


change-over switch inside the electrical box to meet the Indoor unit Indoor unit
resistance in the duct system.

25 26
Indoor Unit Lineup
VRV Indoor Units

Ceiling Suspended Type Wall Mounted Type

FXAQ20P / FXAQ25P
FXHQ32MA / FXHQ63MA
FXAQ32P / FXAQ40P
FXHQ100MA
FXAQ50P / FXAQ63P

Slim body with quiet and wide airflow Stylish flat panel design harmonised
with your interior décor
Adoption of QUIET STREAM FAN

Uses the quiet stream fan and many Stylish flat panel design creates a graceful harmony that
more advanced technologies. enhances any interior space.
Sound absorption
member
Flat panel can be cleaned with only the single pass of a
cloth across their smooth surface.
Flat panel can also be easily removed and washed for
more thorough cleaning.

Turbulent flow Quiet stream fan


is produced Low operation sound level (dB(A))
Straightening vane
FXAQ-P 20 25 32 40 50 63

Sound level
Low operation sound level (dB(A)) (H/L)
35/31 36/31 38/31 39/34 42/37 47/41

FXHQ-MA 32 63 100

Sound level 36/31 39/34 45/37 Drain pan and air filter can be kept clean by mould-proof
(H/L)
polystyrene.

Installation is easy Vertical auto-swing realises efficiency of air distribution.


Drain pump kit (option) can be easily incorporated. Maintenance is easy The louvre closes automatically when the unit stops.
Non-dew Flap with no implanted bristles
Bristle-free Flap minimises
contamination and makes 5 steps of discharge angle can be set by remote
600 mm cleaning simpler. controller. Drain pump kit is available as optional accessory, which
lifts the drain 1,000 mm from the bottom of the unit.
Drain pump kit Discharge angle is automatically set at the same angle
(built inside main unit)
Height of drain-up
as the previous operation when restarting. (Initial setting:
10° for cooling and 70° for heating)
Wide air discharge openings produce a spreading 100° Non-dew Flap
airflow. 1,000 mm
Easy-to-clean flat design Flexible installation
Maintenance is easier because everything can be Drain pipe can be fitted to from either left or
right sides. Indoor unit
performed from below the unit. Drain pump kit

A long-life filter (maintenance free up to one year*) is


100°
equipped as standard accessory.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

27 28