You are on page 1of 3

White - II Steel Chim

Point Rebound hammer Reading


Sr. No. Location
ID
1 2 3 4 5 6
1 1 38.5 39.0 39.0 39.5 41.5 43.5
Hostel - P2
2 2 38.0 38.0 38.5 39.0 39.0 39.5
Column -
3 3 36.5 37.0 37.5 38.0 39.0 39.5

4 1 37.0 37.5 38.0 38.0 39.0 39.5


Academic South
Column - F1 -9
5 2 35.5 35.5 36.0 36.5 38.0 38.0
301.475 to
303.875
6 3 31.0 32.5 35.5 36.5 36.5 38.0

7 1 32.0 33.0 33.5 34.5 34.5 36.5


8 2 35.0 35.0 36.0 36.0 36.5 37.0
Admin Block
9 3 33.0 33.5 33.5 34.0 34.5 35.0
Beam No.
10 4 33.5 33.5 35.5 35.5 36.5 37.0
11 5 30.5 31.0 32.5 34.0 34.0 34.0
White - II Steel Chimney Foundation [Stack (52-ST-1101)]
mmer Reading 2 DEGREE
Strength
Q Average POLYNOM LINEAR POWER
(Mpa)
7 8 9 10 IAL
43.5 44.0 44.0 45.5 42 46 42 46 44
40.5 44.5 46.0 46.0 41 44 41 44 43
39.5 39.5 41.5 50.0 40 43 39 43 41

39.5 40.0 41.5 47.0 40 43 39 43 41

39.5 40.0 41.0 42.0 38 41 37 41 39

38.5 38.5 42.5 46.5 38 40 36 40 38

36.5 38.0 41.5 44.0 36 38 34 38 36


38.5 39.0 40.5 43.0 38 40 36 40 38
37.5 39.5 41.0 41.0 36 38 34 38 36
39.5 41.0 49.0 49.0 39 42 38 42 40
35.5 37.0 39.0 50.0 36 37 34 37 35
OUTLIED BY UPV
EXPONANIAL CLS. OF (IS
8900-1978) direct semi indirect
42 No Outlier 3823
40 No Outlier 3586
38 No Outlier 3924

38 No Outlier
3874

36 No Outlier
3762

35 No Outlier
3904
33 No Outlier
35 No Outlier
33 No Outlier
37 No Outlier
32 No Outlier