GRAIN SIZE ANALYSIS

IS : 2720 Part 4 - 1980

SRAF No 2290 Date 23.07.2019 Dt of Test From 27.07.2019 to 28.07.2019

Sample I/M B.A 03 WADHOTT Visual Classification Yellowish co.weathered


Max. Size of Material present in Substantial 25.000 Max. Individual Partical Size present in (mm) 2.360
Quantity in (mm)
Sample Type Oven Dried Wt. of sample Taken for Analysisin (gm) 2000

Material Retained on
WET ANALYSIS 75 micron in (gm) 897.20 Material Passing 75 micron. In (gm) 8.23

100.00
Grain size analysis
90.00
Percent Finer

80.00

70.00

60.00

50.00

40.00

30.00

20.00

10.00

0.00
0.01 0.1 Diameter
1 In mm. 10 100
Sieve Size Wt.Retained % Retained Cumulative % % Passing
mm. gms.
100 0 0.00 0.00 100.00
80 0 0.00 0.00 100.00
75 0 0.00 0.00 100.00
63 0 0.00 0.00 100.00
50 0 0.00 0.00 100.00
40 0 0.00 0.00 100.00
31.5 0 0.00 0.00 100.00
25 76.7 3.84 3.84 96.17
20 107.6 5.38 9.22 90.79
16 175.6 8.78 18.00 82.01
12.5 147.50 7.38 25.37 74.63
10 230.50 11.53 36.90 63.11
4.75 200.30 10.02 46.91 53.09
2.36 267.60 13.38 60.29 39.71
2 21.50 1.08 61.37 38.64
1.18 232.50 11.63 72.99 27.01
0.6 184.10 9.21 82.20 17.81
0.425 66.40 3.32 85.52 14.49
0.3 12.50 0.63 86.14 13.86
0.15 69.10 3.46 89.60 10.41
0.075 43.50 2.18 91.77 8.23
NOTE : Shaded Portion indicates WET ANALYSIS

GRAIN SIZE DISTRIBUTION

1. Boulders & Cobbles 100.00 Retained on 75 mm.


2. Gravels 46.91 4.75 mm. - 75 mm.
Coarse 9.22 20 mm. - 75 mm.
Fine 37.70 4.75 mm. - 20 mm.
3. Sand 44.86 75 mic. - 4.75 mm.
Coarse 14.46 2mm. - 4.75 mm.
Medium 24.15 % 425 mic - 2 mm.
Fine 6.26 % 75 mic - 425 mic.
4. Silt & Clay 8.23 % Below 75 mic.
Silt 5.93 % 2mic - 75mic.
Clay 2.30 % Below 2 mic.
Particle
&
Size in
Passing
mm

75 100.00
63 100.00
50 100.00
40 100.00
31.5 100.00
25 96.17
20 90.79
16 82.01
12.5 74.63
10 63.11
4.75 53.09
2.36 39.71
2 38.64
1.18 27.01
0.6 17.81
0.425 14.49
0.3 13.86
m. 10 100 0.15 10.41
0.075 8.23
SG= 2.249
DESPERSING
75 micron passing (%)= 8.23 AGENT
CORRECTION 2.5

CORREC Effective
Temp TED Depth Equivalen
TIME Hydromet Temp. VISCOCI
Correctio HYDRO From Calibration t Particle
ELAPSE er Deg C √(Hr/t) TY
n METER (Hr) Chart Diameter
D (min.) Reading (poise)
READIN cms (mm)
G
0.5 27 26.5 0.1 27.5 8.80 4.19 0.00855 0.0607
1 26 27 0 26.5 9.18 3.03 0.00855 0.0439
1.5 25.5 27 0 26 9.37 2.50 0.00855 0.0362
2 24 27 0 24.5 9.94 2.23 0.00855 0.0323
4 23 27 0 23.5 10.32 1.61 0.00864 0.0234
8 22 27 0 22.5 12.07 1.23 0.00863 0.0179
15 18.5 27 0 19 13.40 0.95 0.00874 0.0138
30 17 27 0 17.5 13.98 0.68 0.00884 0.0100
60 16.5 27 0 17 14.17 0.49 0.00874 0.0071
120 14.5 27 0 15 14.93 0.35 0.00884 0.0052
240 13 27 0 13.5 15.50 0.25 0.00855 0.0037
480 12.5 27 0 13 15.69 0.18 0.00849 0.0026
720 12 27 0 12.5 15.89 0.15 0.00874 0.0022
1440 11 27 0 11.5 16.27 0.11 0.00874 0.0016
2160 5.4 0.5 20.47 0.10 0 0.0000
2880 5.4 0.5 20.47 0.08 0 0.0000
Percent Viscosity
Percentag Passing in milli
e Passing w.r. to poise
finer than Total (taken
D (W) Sample From
Table)
90.39 7.44 8.55
86.43 7.11 8.55
84.63 6.97 8.55
79.23 6.52 8.55
75.63 6.22 8.64
72.03 5.93 8.63
59.42 4.89 8.74
54.02 4.45 8.84
52.22 4.30 8.74
45.02 3.70 8.84
39.61 3.26 8.55
37.81 3.11 8.49
36.01 2.96 8.74
32.41 2.67 8.74
12.24 1.01
12.24 1.01

CLAY 2.30
SILT 5.93
Becquerel Industries Pvt. Ltd. Nagpur Quality System Format Doc No. QSFM/ BIPL/01
Issue Date : Revision
Issue No. 1 Revision Section: Page:
01.12.2016 Date:
CALIBRATION OF HYDROMETER
IS : 2720 (PART-4) - 1985 (RA 2010) Clause 5.2.3.2
Date of Calibaration 31.03.2019 Room Temperature-°C 25
Hydrometer no. BIPL 155 Measuring Cylinder Jar No. 1
Vernier Calliper I/M 11030181 Thermometer used
Mass of Hydrometer (gm) 79.8 Diameter of Jar (d)- cm 6.086
1 Initial Water Level in Jar (V1)-ml 800
2 Water Level after Hydrometer immersed in Jar (V2)-ml 880
3 Volume of Hydrometer Bulb (Vh) = V2-V1= 80
4 Mass of Hydrometer (gm) 79.8
5 Distance between two graduations of Measuring Cylinder/Jar (L1)-cm 2.713
6 Volume of two graduations (L1) of Measuring Cylinder /Jar (V3)-ml 80
7 Cross Sectional Area (by Volume) of Measuring Cylinder/ Jar (A1)= (V3/L1)-cm2 29.487
8 Cross Sectional Area of Glass Jar (A2)= (∏/4)*d2= 29.075
9 Average Cross Sectional Area of Glass Jar (A) = (A1+A2)/2 29.281
10 Distance from neck of the bulb to the nearest calibration mark (Ha)-cm 1
11 Distance from neck to bottom of the bulb (h)-cm 16.4
Meniscus Upper Water Levelof Hydrometer Meniscus Reading (m1) 5.5
12 Correctio Lower Water Level of Hydrometer Meniscus Reading (m2) 6
n at 27°C Meniscus Correction (Cm) = m2-m1= 0.5
Dispersin Hydrometer Reading in distilled water at Temp 27°C (m3)
g Agent
13 Hydrometer Reading in Dispersing Agent Suspension at Temp 27°C (m4)
Correctio
n at 27°C Dispersing Agent Correction (cm) = (m4-m3)=
Temperat
ure Room Temperature °C
14 Correctio Hydrometer Reading
n
Distance of each Hydrometer Reading from
Hydrometer Distance Effective Depth Hr in cm
theofLowest
lowestReading (H) cm
Distance from neck
Readings calibration mark to Hr = H+ 1/2 (h-(Vh/A))
(Rh) to the nearest
each major FOR 0 TO 4 Minutes for after 4 minutes
calibration mark
Col.1 calibration
Col.2 mark Col.3 (C2+C3)+0.5(R11-(R6/R9))(C2+C3)+0.5(R11)
30 0 1 7.834 9.200
25 1.911 1 9.745 11.111
15
20 3.822 1 11.656 13.022
15 5.733 1 13.567 14.933
10 7.644 1 15.478 16.844
5 9.555 1 17.389 18.755
0 11.466 1 19.300 20.666
-5 13.377 1 21.211 22.577

0
1.911
3.822
5.733
7.644
9.555
11.466
13.377
60.8
60.85
60.96
60.9
60.8
27.22
26.98
27.14
27.18 HR vs Rh (0 TO 4 MINTS)
30.000
25.000
Hr

20.000 f(x) = − 0.3822 x + 19.2999264369386


15.000
10.000
5.000
-10 -5 0 5 10 15 20 25 30 35
Rh

HR vs Rh(AFTER 4 MINTS)
30.000
25.000
Hr

20.000 f(x) = − 0.3822 x + 20.666


15.000
10.000
5.000
-10 -5 0 5 10 15 20 25 30 35
Rh
12

10

6 Colum
nC

0
0 5 10 15 20 25 30 35
Temperature Correction

HYDROMETER READING
Temperature Hydrometer Reading Chart Title
17 1.002 2 2.5
22 1.001 1 2
f(x) = − 0.2 x + 5.4
27 0.9995 0 1.5
32 0.9975 -1
1
37 0.9965 -2
0.5

-0.5

-1

-1.5

-2

-2.5
10 15 20 25
TEMPERATURE (C DEGREES
Chart Title

f(x) = − 0.2 x + 5.4

20 25 30 35 40
TEMPERATURE (C DEGREES)