NO Severity Specific Problem MO
NO Severity Specific Problem MO
32
Probable Cause
CLOCK_SYNCHRONISATION_PROBLEM
EQUIPMENT_MALFUNCTION
EQUIPMENT_MALFUNCTION
DISK_PROBLEM
EQUIPMENT_MALFUNCTION
LOSS_OF_SIGNAL
REPLACEABLE_UNIT_PROBLEM
CLOCK_SYNCHRONISATION_PROBLEM
CONFIGURATION_OR_CUSTOMIZING_ERROR
UNAVAILABLE
UNAVAILABLE
UNDERLYING_RESOURCE_UNAVAILABLE
CLOCK_SYNCHRONISATION_PROBLEM
CLOCK_SYNCHRONISATION_PROBLEM
EQUIPMENT_MALFUNCTION
FILE_ERROR
THRESHOLD_CROSSED
CONFIGURATION_OR_CUSTOMIZING_ERROR
CONFIGURATION_OR_CUSTOMIZING_ERROR
LINK_FAILURE
EQUIPMENT_MALFUNCTION
CONFIGURATION_OR_CUSTOMIZING_ERROR
EQUIPMENT_MALFUNCTION
POWER_SUPPLY_FAILURE
unreachableIpAddress: *10.159.59.81 (sample IP
Service MME)
PERFORMANCE_DEGRADED
SOFTWARE_ERROR
REFLECTED_POWER_TOO_HIGH
CONFIGURATION_OR_CUSTOMIZING_ERROR
LINK_FAILURE
r
e
Power Failure, DUS problem, Transport problem, OAM IP wrong YES s
t
a
r
The Alarm is secondary Alarm, will raise along with other primary alam such as: t
Packet Server Availability Fault, Synch Reference Not Reliable. If both Packet o
YES
Sync Ref are "UNAVAILABLED", this "Clock Calibration Expiry Soon" will be n
raised.
1
9
Lost contact with the node that controls external alarms, power and climate HW, -
NO
cabinetIdentifier F
e
N/A NO b
,
Result: /c nok, /d ok NO d
o
u
b
e
This alarm is raised if there is a hardware fault in a support system unit. The c
alarm indicates that the unit must be replaced, there is an unrecoverable NO h
hardware fault e
c
k
t
h
Autonegotiation Failed to Meet Minimum Requirements NO e
a
l
This Alarm will impacting Services if both SyncReference a
(Synchronization=1,PacketFrequencySyncRef=1 & r
Synchronization=1,PacketFrequencySyncRef=2) having "Loss of Tracking". This NO (If have standby)m
quite related to transport bandwidth which also simillar symptom impcating
"Sync Reference PDV Problem" Alarm. Related Link towards PTP Servers r
a
i
s
e
a
NTP sync alarm Message: NTP general problem NO
g
a
i
n
SAU, SCU, PDU that is not configured detected NO
o
NO (If have standby)r
n
UNAVAILABLE YES (if both o
"PacketSyncRef" t
DISABLED)
The Alarm is secondary Alarm, will raise along with other primary alam such as:
Packet Server Availability Fault, Synch Reference Not Reliable. If both Packet YES
Sync Ref are "UNAVAILABLED", all EUtranCellFDD will "DISABLED" and this
"PLMN Service Unavailable" will be raised.
The Alarm is secondary Alarm, will raise along with other primary alam such as:
Hw Fault, No Connection, Inconsistent Configuration, PowerFailure, Current Too YES
High
The alarm is raised when an RBS is configured with an external fan group, and NO
the Support Control Unit (SCU) temperature sensor function reports a fault
Either the CPRI cable is wrongly connected or there is a configuration fault YES
Not in operation, additionalData: id 1, unitId 1, portNo 0, cause BER LOS (Mixed YES
Mode)
The Alarm is secondary Alarm, will raise along with other primary alam such as:
Hw Fault, No Connection, Inconsistent Configuration, PowerFailure, Current Too NO
High
Timeout when trying to access radio. (This alarm will raised the secondary YES
alarm: "Service Degraded").
The alarm is raised when the measured RF reflected power in the radio unit
exceeds a predefined threshold. (This alarm will raised the secondary alarm: NO
"Service Degraded").
The Cabinet managed object is empty or if the attribute NO
1.Identify and restart the faulty board or unit. See Restart Board for instructions.
2.Check that the alarm has ceased.
3.If the alarm remains, identify and lock the faulty board or unit. See Lock Board for instructions.
4.Replace the faulty board or unit.
See Replacing Alarm Units, Replacing Control Units, Replacing Power Units or Replacing EMU for
instructions.
5.Unlock the board or unit. See Unlock Board for instructions
"get ntp", check the Ntp Server Ip Address. For LTE Phase-1 and Phase-2, the Server-1 IP is
(10.200.170.116) & Server-2 IP is (10.203.178.165). If wrong IP, do change the IP address. Alarm will be
ceased. In normal condition, ,NtpServer=1 service status is "6 (SYSPEER)" and NtpServer=2 service
status is "4 (CANDIDATE)". Or Either one NtpServer service status is "6 (SYSPEER)".
Need to check on site. Check on EPC Bus cable to SAU, SCU, PDU
Check both IP adressed of PTP Server are correct (follow ATND). If all IP and VLAN address are correct,
need to check on Transport (PDH, SDH, ME, PE Router) and NTP Server it self (Hardware/Software)
Clear the primary alarm, this alarm will be ceased
Warm Restart DUS and if not cease, check transport bandwidth bottle neck
Check both IP adressed of PTP Server are correct (follow ATND). If all IP and VLAN address are correct,
need to check on Transport (PDH, SDH, ME, PE Router) and NTP Server it self (Hardware/Software)
Delete the corrupted upgrade package (make sure not the current UP)
LOCKED Impacted Cell for 8 seconds and UNLCOKED it
Restart impacted RRU/RU or DUS Warm Restart
Instal complete LKF / inject optional required LKF. Always check "st cell & ue print -admitted"
Restart RRU, check "st cell", if still not up, check "cabx", can see normally RRU faulty
Check configuration, cabx and probably need to check on site on the RiLink connection between DUS -
RRU
Restart impacted RRU/RU. If "No connection with
ManagedElement=1,Equipment=1,AuxPlugInUnit=RRU-1", then need to check on site on the
RiLInk/SFP's connection between DUS-RRU
Related to "Heartbeat Failure", need to check RU & DU power at site
Check on MME IP Service, S1_MME Vlan. All good, its more towards Transport issue (SCTP)
Need to check on site, due to problems in the antenna cable or in the RF connector
set Equipment=1,Cabinet=1 productData, or if product data not available, copy from 3G product data