You are on page 1of 3

IAC-I-W-01

IP68 - 5 BAR INDUSTRIAL ACCELEROMETER


CURRENT LOOP OUTPUT (4-20 mA)

PROPERTIES
•• 4.-20mA signal conditioning
•• Self-powered Current Loop
•• Galvanically Isolated
•• Protected against false polarization
•• Compact and rugged design
•• Protection grade IP68 - 5 bar
•• Marine cable

BLOCK DIAGRAM
Internal Power Supply

+24V
4 .. 20 mA
Sensor
Output
Iout

DIMENSIONS

Recovib_IAC-I-W-01_EN-rev0p1
SPECIFICATIONS

Output Range 4..20mA


Supply voltage 12-30 V
Measuring Range ± 2g or ± 6g
OUTPUT Sensibility 4.5 mA/g or 1.35 mA/g
Lower frequency limit 0 Hz (DC)
Upper frequency limit (-3 dB) 1000 Hz
Non-linearity ± 0.5 % F.S.
Residual noise 50 µg/√Hz
Transverse sensitivity <5%
Destruction limit ± 5000 g
Operating Non-Operating
ENVIRONMENTAL Temperature range - 20-85 °C (1) -40-85°C (-40-167°F)
CHARACTERISTICS
Temperature coefficient of ± 0.01 %/°C
sensitivity
Temperature drift of zero point ± 0.5 mg/°C
Protection grade IP68 - 5 bar
Weight Without Cable 30gr (1 oz)
MECHANICAL Case Material/Cable gland Stainless Steel A4 (AISI316)
DATA Cable Marine Type
Mounting 3.2 mm diameter holes (4x)

ELECTRICAL CONNECTIONS

ACQUISITION SYSTEM

SENSOR

24 AWG (0,23mm²) Twisted Pair + Shield


Red

24V Power Supply

White

Current to To Analog
Voltage to Digital
Converter Converter

Recovib_IAC-I-W-01_EN-rev0p1
ORDERING INFORMATION

IAC - I - W - 01 - A - X - XX.X m

Sensing
RANGE Cable Length
Axis
X 2 ± 2g
Y 6 ± 6g
Z

Rue du Trou du Sart 10 Tel. +32(0)81248100 | Fax. +32(0)81248101


B-5380 Fernelmont | Belgium info@micromega-dynamics.com
EU ID.:BE0466034916 www.micromega-dynamics.com