You are on page 1of 24
Institute of Engineering Pulchowk Campus Department of Architecture Internal Assessment Examination Year/Part IV (A/B) Full Marks: 100; Pass Marks: 40 Time: 2 hrs 15 minutes ‘Attempt all Questions 1 Design a wooden beam for a room of clear span of 5 m supported on wall of 25 cm thick at both ends. The beam carries @ udl of 24 KNim including self weight of beam. (12] Permissible stress in bending in tension/compressios Permissible stress in shear = 1.3 Mpa Permissible stress in bearing normal to gra Modulus of Elasticity of timber = 1.2.x 10" 2 Design a timber column of 5m height to carry a load of 60 tonnes. Take o., = 125 kglcm’, 2x 10° kgiem’. (8 Find the maximum load P that can be applied on the bracket plate connected with 20 mm pds rivets as shown in fgu below. The Thickness of bracket plate is 12 mm, Take permissible shearing stress in rivet is 100 Mpa, permissible bearing stress in rivet is 300 Mpa, (12) 16Mpa 3.5 Mpa cee oes ae 4 Design a slab base for a column consisting of a SC250 carrying a axial load of 1500 KN. Also design the concrete {foundation on which the plate rests. Use permissible bearing pressure on concrete as 4 Mpa and Bearing capacily of soil fas 300 KNim?. (For SC 250, B=250mm, h = 250 mm) [10] Design a gusseted base for a column consisting of a HB300 with two cover cover plate of 300 x 20 carrying a axial load of 3000 KN. Also design the concrete foundation on which the plate rests. Use permissible bearing pressure on concrete as 4 Mpa and Bearing capacity of soll as 400 KN/m?. Also, use 22 mm thick gusset plate & ISA 150 x 115 x 16 cleat angle. (14) le v4 a : ' us — 1 ae ISA 150% 115% 16 8 Design @ laterally restrained steel beam of 16 m effective span carrying a udl of 20 KN/m including its self-weight. Use steet Section ISWBSS0@112 kgim,(For |SW550; Z,= 2720 cm®,h = 550, B = 250, l= 74800 om) [10] 72> ony (Page 1 of2) wath 7 Design a RCC beam having cross section 300mm X 600 m 30 KNim including self weight and live load of 20 KN/n Use E Vin tien aa L | o16 ois { 7 ” 8 A simply supported RCC beam havi ve the bean is subjectad to a factored sh ‘and Fe 415 rOAF (tye for M26 °3.1 Mpa) (10) on our 100 064 095 | 040 036 | O40 Design a RCC § Th aftection is mandatory. (14) ib for a room mi | Short span coven, 4 # ro faa [aa | os | an | oe Tappon mame pear moment F594, | o.0x7 | 004s | 0.47 | oan | 0.058 090 | 0.0% | 0.041 (Bost of Luck) (Page 2 0f2) Mri M26 vurrete wil Fe 600 reba (10) Jos section 260m" % 600 rimfattwolive dept) Ie peevided MH 1 of 260) KN a ugg, eign Hie aint raintartarrnlt ia on 1b (8 supported on 250 mm wide beam and continuous all around, Use M126 connote anid Fe GOO tabi 0.088 pons iin eid tone Tol ot om on A sane tment ii | 1% ony | Oa 460 on i” on suring 3 m x 6 mis subjected to Naot thts ted of 1.6 KAMA” wre Live lame A KIN? nn to arg syn eovetNenern, in tov ah vous of one, oo oon “wn dy pe We ‘ ¢x]029 ae sort $24 3 2G AME Assung d 93 35 5 Cw ee Usireg. Bnd reboy adit? clean 6-2 1. back depto, ‘ | Dp ‘gc tso- £-20= 126 Or A - ISO ROC Veraawens 1S +5 * ee 29:26 KN TD” 2Z € A992 2°gts KM / Be So eth BIS 1 Now, Jy a PTY 0 Wo Wry Sla& Usi & foble ; Support moment et. for Short spany Oy = 0: 253+ ss (rercs-1S) { design naroent 24 d for giep Uh 7 fais mosit un abov’ ; aa “Nesign Moment Mus 8:24 ha HESS oie Ria; 5 — yA coon ASE a 2 eee topes 2? spades Tyersal for Gea \ 041 we g Joo 5 Gar "1092/4 zy = 926 temp >. 3p See '"2 Proud 2m idia ses QU222 ma a x chek fm clef teeta Ag, prov oe ee oy 208 eh p> 258 2F ioe > OSE XSOCOR Tore 126 1c4 + 109.2 = yy ™ paee TIT. Sz Pa,

You might also like