Study Parameter Guidewords Deviation Causes Consequences Protection and

Node Recommendation
Flow Less Less flow 1. The control 1. Column will 1. Installation
valve is fully dry out of low-level
shut alarm

2. Tube leakage 2. The product 2. Emergency


and blocking quality will plant shut
change down.

More More flow 1. The control 1. Produce 1. Installation


valve is fully flooding in the of high-
opened column level alarm

2. Increase the 2. The 2. Check the


pumping temperature in maintenance
capacity the column and
will decrease schedule

No No flow 1. The failure of 1. No operation 1. Make


the pump occurred bypass in
the column
2. Blocking and 2. Possible of
tube leakage dangerous 2. Installation
concentration of low-level
alarm and
emergency
plant shut
down