EN 12680-2:2003 (E)

Key
a Scanning position "A"
b Scanning position "B"
c A-scan from scanning position "A"
e A-scan from scanning position "B"

Depth extension d = t - (s1 + s2)

where

t is the wall thickness;


s1, s2 are the lengths of the sound-beam paths.

Figure 5 — Measurement of the dimension of discontinuities in through-wall direction with normal probes

--`,,,,`,,````,,,`,,,`,`,,,``,`-`-`,,`,,`,`,,`---