Professional Documents
Culture Documents
EQUIPMENT
URGENT
KWAZULU-NATAL:
P.O. BOX 15108
WESTMEAD 3608 critical
TEL: (031) 700 5460
Mr N A Karim [Nasser Ayoub] FAX: (031) 700 5471 urgent
Alkhorayef Kuwait border
Yall Tower & Mall GAUTENG:
16th Floor P O Box 46813 P.O. BOX 284 normal
ISANDO 1600
Fahaheel 64019 TEL: (011) 392 6322 1 2 key
KUWAIT FAX: (011) 392 6340
samples
DIAGNOSIS
2.) Sample Number E354386 on 21.02.2019 smr 6767 HRS
Greater than 4% but less than 8% fuel dilution evident, check fuel system for
malfunction. Fuel dilution made the oil unfit for further use. Oil already changed
do not drain again. Please return feedback.
PREVIOUS HISTORY
DIAGNOSES FEEDBACK
1.) Sample Number D110596 on 25.09.2018 smr 3867 HRS
Viscosity appears low for this grade of oil. Wear rates are normal. Oil already
changed do not drain again.
P.T.O.
WEARCHECK IS AN ISO 9001 AND ISO 14001 REGISTERED COMPANY
Machine: G-507 - ENGINE - Alt. ID: PLX900515 -
SAMPLE DATE LAB OIL OIL IN FILTER OIL
NUMBER SAMPLED DATE CONSUMPTION SMR UNITS SERVICE CHANGE DRAIN RRI
1 D110596 25.09.18 09.10.18 - 3867 HRS 338 Yes Yes 250
2 E354386 21.02.19 06.03.19 - 6767 HRS 338 Yes Yes 250
1 8 0 0 1 0 0 0 1 0 5
2 14 0 0 1 2 0 1 0 0 5
30 spectrometric analyses are carried out on all samples but only relevant results are reported in parts per million.
CONTAMINANTS -
1 1 5 0 0.0 14 21 7 <1 ND
2 2 3 16 0.3 14 22 8 >4<8 ND
30 spectrometric analyses are carried out on all samples but only relevant results are reported in parts per million.
30 spectrometric analyses are carried out on all samples but only relevant results are reported in parts per million.
Copyright Wearcheck Issued subject to standard conditions (available on request). Requested by report