You are on page 1of 1
PROJECT NO. 44PS5400 PROJECT : RSPL Soda Ash Plant at Jamnagar TITLE: INSTRUMENTATION GENRAL GUIDELINES TO Document No, ‘44PS5400-001N/.02/0002 REVNO.: B ISSUE DATE: 16.11.2015 PACKAGE VENDORS, PAGE 7 OF 21 Accuracy of he Instruments shall be minimum as follows: ‘Accuracy of Instruments Type of instrument Accuracy = Differential pressure & Pressure transmiter- SMART £ 0.075% of span ~ Variable area type flow meter wit transmitter “+ 2.0% FS Note (1) ~ Vortex flow meter 10% FS ~ Postve displacement fow meter + 05% FS = Tutbine meter or Mass flow meter + 05% FS ~ Magnetic ype flow meter + 05% FS ~ Ultrasonic type flow meter + 05% FS ~ Tank gauge © 10% FS ~ ServoiRadar ype tank gauge + 2mm (up to 20 m height) for Radar ‘Accuracy shall be 1mm or better for custody transfer and 5 mm or better for normal application = Draft range Pressure transmitter - SMART + 0.15% of span = Diaphragm seal transmitter - SMART 7 “+ 0.2% of span | = Pressure gauge £ 1.0% FS + Temperature Transmitter 0.2% of calibrated span for RTD & + 0.5% of | calibrated span for Thermocouples ~ Filled system / Bimetallic + 1.0% FS ~ Smal size pressure gauge + 3.0% FS | ~ Draft gauge + 3.0% FS = Receiver gauge fe 18% FS ‘Thermocouple & Resistance Bulb Applicable Codes/Standards Note: 1. Vendor's standard accuracy is applied to local indicator type. Remarks: 1. Accuracy of instrument and special articles except for the above mentioned instrument shall be in accordance with the applicable codes / standards, or Vendor's standards as approved by Jacobs / RSPL. 2. FSFFullscale. 3. Overall rangeabiity of transmitter except for draft range shall be 1: 100. Draft range transmitter rangeabilly shall be 1: 30 for the accuracy indicated above,