You are on page 1of 10

Level Switch

PulseCAP 20
Advanced Capacitance Measuring Technique

`` LEEC Compact Level Switch PulseCAP20


Extremely compact, the switch is ideal for
restricted or limited space, low cost.
This compact level switch is viable for most
industrial situations, whether they are food,
beverage, pharmacy, animal feed or chemical
industry.

`` LEES Level Switch PulseCAP20


Capacitive level switch is cleverly designed for any applications in Hygienic & Industry.
The level switch utilizes the advanced capacitive measuring technology to achieve precise
switching for any kind of media, even with foam.

Highlight Features

``Easy calibration for any applications


``Can be used for both Conductive and Non-conductive
media (Dielectric constant > 1.5)
``Can be used for Liquid, Solid & Paste
``Wetted parts are made from Stainless Steel 316L/304L ``Can be used for Metal tank or Plastic tank
and PEEK ``Process temperature -40 ... +200°C
``03 Versions: Hygienic, Industry and Extreme Corrosive ``Not influenced by foam, coating
``Hygienic connections conform to 3A standards ``LED indicator for Power and Signal
w w w. d a v i t e q . c o m Level Switch

Te c h n i c a l D a t a

Level Switch LEES Compact Level Switch LEEC


Technical Feature Specification
SENSING
Method PulseCAP advanced capacitance measuring techniques (patend pending)
Media Any media with Dielectric Constant value >1.5
Media states Liquid, Solid, Paste
Tank materials Any conductive or non-conductive material
ELECTRICAL
Power supply 9 .. 35 VDC
Current consumption 20mA max
Damping 0.05 to 10 sec (adjusting allowable)
Power up time < 1.5 sec
Hysterisis Adjustable by DIP switch or Software
Repeatability +/- 1.0mm
Reaction time 100mS
Photocoupler 120mA max or Relay 5A SPST,
Output Photocoupler 120mA max
NO contact
Indicator LED indicator on cover LED Indicator on housing
EMC Complied to standard EN 61326
Standard: 01 x PG13.5 or M20 or 1/2”NPT con-
duit
Electrical connections M12 unshielded connector – male – 4 pin
Option: 01 x M12 unshielded connector – male
– 4 pin
MECHANICAL
Process connection Hygienic G1/2, Tri-clamp 3A/DN38, Sliding, NPT Threaded and Flanges
Accessories for installation Hygienic welding nozzle for Pipe or Tank
Wetted parts PEEK with 316LSS/304SS
Housing 304SS, IP65 with cover 304SS, IP67 with M12 connector, no cover
Process connection material 316LSS or 304SS or 304SS with PTFE lined 304SS or 316LSS
Ambient Temperature -40 .. + 85 Co

-40 .. + 115oC
Process Temperature -40 .. +150 or +200 C (with extension neck)
o
(up to 150oC in 1hr)

Hygienic G1/2 <= 100 barg


Hygienic G1/2 <= 100 barg
3A/DN38 <= 40 barg
3A/DN38 <= 40 barg
Process Pressure Sliding <= 16 barg
Industry version <= 100 barg
Industry version <= 100 barg

Vibration Complied to standard IEC 60068-2-6


P u l s e C A P Te c h n o l o g y

Dimension Drawings

28

130

51

18

PulseCAP20 Level Switch LEEC-H


w w w. d a v i t e q . c o m Level Switch
Part Arrangement
`` +PW : Power Supply 9…36VDC
`` GND : Mass
`` E / NO: E pole/ Normal Open Contact
`` C/ COM : C pole/ Common
`` Led : Detection level indicator
`` Button : Sensitivity adjusting dipswitch

`` M12 Plug Connection


1 - Power +24VDC (Brown)
2 - Tech-in
3 - Ground (Blue)
4 - Output (Black)

Wiring Connections

`` RELAY OUTPUT:

`` OPTOCOUPLER OUTPUT:
Sink type Source type

Adjustment
`` OFFSET ZERO SPAN AND FULL SPAN
Set Zero Span: Press and keep button about 500ms – 3s, Led flash on 5hz
Set Full Span: Press and keep button about 4 – 8s, Led flash on 1.25hz

`` SENSITIVITY ADJUSTING DIP SWITCH

Detection level setting value Damping Time


BIT1 BIT2 ON OFF BIT3 BIT4 Damping time
(%) (%)
0 0 500 ms
0 0 90 85
0 1 50 ms
0 1 60 40
1 0 5 Sec
1 0 40 60
0: dip switch off 1 1 Setting detection level value and
1 1 85 90
1: dip switch on damping time by computer
P u l s e C A P Te c h n o l o g y

Install Application

Selection Guide

MODEL APPLICATIONS INSULATION

LEES-H Level switch for hygienic applications: F&B, pharmaceutical Hygienic Probe

LEES-I Level switch for industry applications, low corrosive Industry Probe
LEES-F Level switch for industry applications, extreme corrosive Fully Lined Industry Probe
Compact Level switch for hygienic applications: F&B, phar-
LEEC-H Hygienic Probe
maceutical
w w w. d a v i t e q . c o m Level Switch
Ordering Code

HYGIENIC APPLICATIONS
PulseCAP20 Level Switch LEES-H

LEVEL SWITCH FOR HYGIENIC APPLICATIONS: F&B, PHARMA-


1 LEVEL SWITCH TYPE LEES-H
CEUTICAL..., CONDUCTIVE AND NON-CONDUCTIVE MEDIA
0 HYGIENIC G1/2”
1 HYGIENIC TRI-CLAMP 3A/DN38
2 PROBE TYPE & CONNECTION
2 HYGIENIC ADJUSTABLE 100MM LENGTH
3 HYGIENIC ADJUSTABLE 250MM LENGTH
0 304SS
3 HOUSING
1 316SS
A 1/2”NPT CONDUIT
B M20 CONDUIT
4 ELECTRICAL CONNECTION
C PG13.5 CONDUIT
D M12 CONNECTOR

0 OPTOCOUPLER, OPEN COLLECTOR 120mA/24VDC, 4-WIRE

1 SPST RELAY, NO CONTACT, 5A/24VDC OR 220VAC, 4-WIRE


5 OUTPUT
2 WIRELESS, BATTERY OPERATED
3 CONNECTED, 4-WIRE

(*) : Standard codes

`
`Example LEES-H 0 0 A 0
OUTPUT OPTOCOUPLER, OPEN COLLECTOR
120mA/24VDC, 4-WIRE

ELECTRICAL CONNECTION 1/2”NPT CONDUIT


HOUSING 304SS

PROBE TYPE & CONNECTION HYGIENIC G1/2”

LEVEL SWITCH TYPE LEVEL SWITCH FOR HYGIENIC APPLICATIONS: F&B,


PHARMACEUTICAL..., CONDUCTIVE AND NON-CONDUCTIVE MEDIA
P u l s e C A P Te c h n o l o g y

INDUSTRY APPLICATIONS
PulseCAP20 Level Switch LEES-I

LEVEL SWITCH FOR INDUSTRY


APPLICATIONS, LOW CORROSIVE,
1 LEVEL SWITCH TYPE LEES-I
CONDUCTIVE AND NON-CON-
DUCTIVE MEDIA
PROBE LENGTH & MATERIAL 304SS 316SS
SELECT ONE MATERIAL ONLY 0 A 100mm
1 B 150mm
2 C 200mm
3 D 300mm
2 4 E 400mm

5 F 600mm

6 G 1000mm
7 H 1500mm
8 F 2000mm
PROCESS CONNECTION SIZE & MATERIAL 304SS 316SS
SELECT SAME PROBE MATERIAL 0 A 1/2”NPT THREADED
1 B FLANGE SIZE 25
2 C FLANGE SIZE 40
3 D FLANGE SIZE 50
3 4 E FLANGE SIZE 65
5 F FLANGE SIZE 80
6 G FLANGE SIZE 100
7 H FLANGE SIZE 125
8 K FLANGE SIZE 150
A FOR “0” PROCESS CONNECTION
B ANSI 150
C ANSI 300
4 FLANGE STANDARD D JIS 10K
E JIS 20K
F PN16
G PN25
0 NONE, 150 DEGC MAX
5 EXTENSION NECK
1 EXTENSION, 200 DEGC MAX
0 304SS
6 HOUSING
1 316SS
w w w. d a v i t e q . c o m Level Switch
A 1/2”NPT CONDUIT
B M20 CONDUIT
7 ELECTRICAL CONNECTION
C PG13.5 CONDUIT
D M12 CONNECTOR
OPTOCOUPLER, OPEN COL-
0
LECTOR 120mA/24VDC, 4-WIRE
SPST RELAY, NO CONTACT,
1
8 OUTPUT 5A/24VDC OR 220VAC, 4-WIRE
WIRELESS, BATTERY OPER-
2
ATED
3 CONNECTED, 4-WIRE

(*) : Standard codes

`
`Example LEES-I 0 0 A 0 0 A 0

LEVEL SWITCH FOR INDUSTRY APPLICATIONS, LOW CORROSIVE,


CONDUCTIVE AND NON-CONDUCTIVE MEDIA

INDUSTRY-EXTREME CORROSIVE
PulseCAP20 Level Switch LEES-F

LEVEL SWITCH FOR INDUSTRY APPLICATIONS, EXTREME


1 LEVEL SWITCH TYPE LEES-F CORROSIVE, CONDUCTIVE AND NON-CONDUCTIVE
MEDIA
0 100mm
1 150mm
2 200mm
3 300mm
2 PROBE LENGTH (MM) 4 400mm

5 600mm

6 1000mm
7 1500mm
8 2000mm
P u l s e C A P Te c h n o l o g y

0 3/4”NPT THREADED, PEEK MATERIAL


1 FLANGE SIZE 25
2 FLANGE SIZE 40
3 FLANGE SIZE 50
3 PROCESS CONNECTION 4 FLANGE SIZE 65
5 FLANGE SIZE 80
6 FLANGE SIZE 100
7 FLANGE SIZE 125
8 FLANGE SIZE 150
A FOR “0” PROCESS CONNECTION
B ANSI 150
C ANSI 300
4 FLANGE STANDARD D JIS 10K Modified (thicker)
E JIS 20K
F PN16
G PN25
0 NONE, 150 DEGC MAX
5 EXTENSION NECK
1 EXTENSION, 200 DEGC MAX

0 304SS
6 HOUSING
1 316SS
A 1/2”NPT CONDUIT
B M20 CONDUIT
7 ELECTRICAL CONNECTION
C PG13.5 CONDUIT
D M12 CONNECTOR
OPTOCOUPLER, OPEN COLLECTOR 120mA/24VDC,
0
4-WIRE
SPST RELAY, NO CONTACT, 5A/24VDC OR 220VAC,
8 OUTPUT 1
4-WIRE
2 WIRELESS, BATTERY OPERATED
3 CONNECTED, 4-WIRE

(*) : Standard codes

`
`Example LEES-F 2 1 B 0 0 A 0 OPTOCOUPLER, OPEN COLLECTOR 120mA/24VDC,
4-WIRE

ELECTRICAL CONNECTION 1/2”NPT CONDUIT


HOUSING 304SS
EXTENSION NECK NONE, 150 DEGC MAX
FLANGE STANDARD JIS 10K
PROCESS CONNECTION FLANGE SIZE 25
PROBE LENGTH 200mm
LEVEL SWITCH TYPE LEVEL SWITCH FOR INDUSTRY
APPLICATIONS, EXTREME CORROSIVE, CONDUCTIVE
AND NON-CONDUCTIVE MEDIA
w w w. d a v i t e q . c o m Level Switch
COMPACT LEVEL SWITCH
PulseCAP20 Level Switch LEEC-H

LEEC-H
1 LEVEL SWITCH TYPE Compact level switch for hygienic application: F&B, Pharmaceutical...,
conductive and non-conductive media

2 PROBE TYPE Hygienic G1/2’’

3 HOUSING 304SS
4 ELECTRICAL CONNECTION M12 connector
5 OUTPUT optocoupler, open collector 120mA/24 VDC, 4 wire

Accessories for HYGIENIC

Cylindrical Cylindrical sleeve Weld-in sleeve Cylindrical sleeve


NAME Weld-in ball
sleeve with tell-tale hole with collar with weld-in ring
LEAM-G1/2-CSH LEAM-G1/2-WS LEAM-G1/2-CSR LEAM-G1/2-WB
ITEM LEAM-G1/2-CS
(for vessels with (for thick-walled (for installation on (for sloped instal-
CODE (for vessels)
leakage detection) vessels) pulled-out pipes) lation)

G1/2’’